Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Accessibility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

What Were the Cost Drivers for Publicly Accessible Charging Installations?

Publicly accessible EVSE stations in The EV Project are defined as those installed for businesses, institutions, and municipalities to provide charging for any plug-in electric vehicle (PEV). Typically, no formal relationship exists between the charging site host and the PEV driver utilizing the EVSE. Whereas, fleet, workplace, and residential charging stations are intended to serve a restricted population of PEVs with drivers formally related to the charging site host in some manner. Costs for installation of publicly accessible EVSE units were an important consideration of The EV Project, because these costs had an impact on host participation and, subsequently, on the public’s perception of PEV adoption. In an effort to achieve the objective of establishing and studying a rich infrastructure of publicly accessible charging stations, The EV Project intended to make AC Level 2 EVSE free to the host; including installation. This would have reduced the economic influence on the host’s decision to install a station at locations that the EV Micro Climate® planning process identified as desirable. Although The EV Project provided a significant allowance toward the cost of installation, in many cases, actual installation costs exceeded that allowance. Other concerns from prospective charging site hosts included the observation that there were not enough PEVs to create demand for stations, and hosts were being requested to effectively eliminate a customer parking space to be designated for PEV charging.

25 ENERGY STORAGE↗

Engineering Accessible Adsorption Sites in MOFs for CO 2 Capture (Final Report)

The overall goal of this project was to synthesize metal-organic frameworks (MOFs) with improved CO 2 adsorption and selectivity properties for potential application in removing this greenhouse gas from flue gas streams during fossil fuel processing. MOFs are an important class of 2-dimensional (2D) and 3D supramolecular coordination polymer networks that are comprised of organic linkers (ligands) and metal ion-units or clusters. They generally possess very high surface area, porosity, variable thermal stability and tunable chemistry, which make them potentially candidates CO 2 adsorption. The three specific objectives of this project were as follows: 1) To synthesize MOFs with metal ions adsorption sites in more accessible locations within the structures (towards the center of the organic linkers) in order to enhance their CO 2 adsorption characteristics; 2) To investigate the CO 2 adsorption properties of new MOFs containing pyrazine- and other nitrogen containing ligands as possible improved alternatives to known amine-functionalized MOFs; and 3) To investigate the nature of the adsorption sites and mechanism(s) by conducting computational studies on CO 2 adsorption within the MOF structures and compare the results with experimental observations. The main outcomes of this research are as follows. Nitrogen-containing ligands that possesses a diaza-12-crown-4-ether moiety at the center of two phenylcarboxylic acid groups was utilized to synthesize 3D MOFs in which the added transition metal ions (i.e.CO 2 + and Mn2+) were coordinated within the crown moieties. Therefore, the structures had the metal ions in more accessible locations. The new 3D structures, being non-porous however, showed negligible adsorption capacity for CO 2 . The ligand 2,3,5,6,-pyrazinetetracarboxylic acid (PZTC) was successfully used to synthesize four new MOFs, each with one of the following metal ion; Ca2+(1D), Zn2+(2D), Mn2+ (3D) and Gd3+(3D), and with the dimensionality (D) indicated. The Ca-, Zn- and Mn- PZTC-based MOFs had no obvious accessible pores and showed no adsorption capacity for CO 2 . Gd-PZTC structure however, showed promising capacities of 1.0 mmol/g and 0.6 mmol/g at 273K and 298 K respectively. Another nitrogen-containing ligand explored was 2,2’-dinitro- trans-4,4’- stilbenedicarboxylic acid (DNSDC) and in combination with a co-ligand, 2,2’-bipyridine (2,2’-BPY). The combination of DNSDC with CO 2 + and Mn2+ yielded four new thermally stable MOFs that showed significant CO 2 absorption capacities. The experimental CO 2 adsorption capacities varied among the structures, ranging between 1.8 mmol/g at 256 K and 0.8 mmol/g at 298K. The DNSDC-based structures maintained significant stability and capacities over many adsorption cycles at 298K. With 2,2’-diamino- trans-4,4’-stillbene dicarboxylic acid (DASDC) as ligand instead of DNSDC, new 3D MOF structures were also synthesized. The structures however were less stable, and decomposed on activation (exposure to vacuum and or solvents) and therefore showed negligible CO 2 adsorption capacities. The dinitro-stilbene based MOFs showed promising CO 2 adsorption capacities, thermal stabilities and recyclability, and therefore showed potential for application in CO 2 removal from flue gas. The research accomplishments presented herein supports the Department of Energy’s (DOE) Office of Fossil Energy and the National Energy Technology Laboratory (NETL) mission in the area of research that advances the science of coal technologies, specifically carbon capture and storage. The research outcomes can guide rational design/synthesis strategies towards producing advanced materials for CO 2 capture. However, further research is needed in order to develop the materials to meet or exceed capacities and stabilities that are reported for their counterparts.

20 FOSSIL-FUELED POWER PLANTS↗

Engineering Accessible Adsorption Sites in MOFs for CO 2 Capture

The overall goal of this project was to synthesize metal-organic frameworks (MOFs) with improved CO 2 adsorption and selectivity properties for potential application in removing this greenhouse gas from flue gas streams during fossil fuel processing. MOFs are an important class of 2-dimensional (2D) and 3D supramolecular coordination polymer networks that are comprised of organic linkers (ligands) and metal ion-units or clusters. They generally possess very high surface area, porosity, variable thermal stability and tunable chemistry, which make them potential candidates for CO 2 adsorption. The three specific objectives of this project were as follows: 1) To synthesize MOFs with metal ion adsorption sites in more accessible locations within the structures (towards the center of the organic linkers) in order to enhance their CO 2 adsorption characteristics; 2) To investigate the CO 2 adsorption properties of new MOFs containing pyrazine- and other nitrogen containing ligands as possible improved alternatives to known amine-functionalized MOFs; and 3) To investigate the nature of the adsorption sites and mechanism(s) by conducting computational studies on CO 2 adsorption within the MOF structures and compare the results with experimental observations. The main outcomes of this research are as follows: Nitrogen-containing ligands that possess a diaza-12-crown-4-ether moiety at the center of two phenylcarboxylic acid groups were utilized to synthesize 3D MOFs in which the added transition metal ions (i.e. Co 2+ and Mn 2+ ) were coordinated within the crown moieties. Therefore, the structures had the metal ions in more accessible locations. The new 3D structures, being non-porous however, showed negligible adsorption capacity for CO 2 . The ligand 2,3,5,6,-pyrazinetetracarboxylic acid (PZTC) was successfully used to synthesize four new MOFs, each with one of the following metal ions; Ca 2+ (1D), Zn 2+ (2D), Mn 2+ (3D) and Gd 3+ (3D), and with the dimensionality (D) indicated. The Ca-, Zn- and Mn- PZTC-based MOFs had no obvious accessible pores and showed no adsorption capacity for CO 2 . Gd-PZTC structure however, showed promising capacities of 1.0 mmol/g and 0.6 mmol/g at 273K and 298 K respectively. Another nitrogen-containing ligand explored was 2,2’-dinitro- trans-4,4’- stilbenedicarboxylic acid (DNSDC) and in combination with a co-ligand, 2,2’-bipyridine (2,2’-BPY). The combination of DNSDC with Co 2+ and Mn 2+ yielded four new thermally stable MOFs that showed significant CO 2 absorption capacities. The experimental CO 2 adsorption capacities varied among the structures, ranging between 1.8 mmol/g at 256 K and 0.8 mmol/g at 298K. The DNSDC-based structures maintained significant stability and capacities over many adsorption cycles at 298K. With 2,2’-diamino- trans-4,4’-stillbene dicarboxylic acid (DASDC) as ligand instead of DNSDC, new 3D MOF structures were also synthesized. The structures, however, were less stable, and decomposed on activation (exposure to vacuum and or solvents) and therefore showed negligible CO 2 adsorption capacities. The dinitro-stilbene based MOFs showed promising CO 2 adsorption capacities, thermal stabilities and recyclability, and therefore showed potential for application in CO 2 removal from flue gas. The research accomplishments presented herein support the Department of Energy’s (DOE) Office of Fossil Energy and the National Energy Technology Laboratory (NETL) mission in the area of research that advances the science of coal technologies, specifically carbon capture and storage. The research outcomes can guide rational design/synthesis strategies towards producing advanced materials for CO 2 capture. However, further research is needed in order to develop the materials to meet or exceed capacities and stabilities that are reported for their counterparts.

20 FOSSIL-FUELED POWER PLANTS↗

Understanding Data Structures by Extracting Memory Access Graphs

Understanding the data structures employed by a program is important for reverse engineering activities and can improve the results of automated software analysis techniques. In a compiled binary, access to data structure fields and array indices defined in the source program are replaced by raw pointer arithmetic. We present a representation for capturing the essential details of how a program accesses memory regions, which we call a Memory Access Graph (MAG), and a static analysis for automatically extracting this information from a program binary. The static analysis to extract the MAGs from the program is straightforward and does not require sophisticated integer or pointer analysis. The MAGs are readily understood by reverse engineers; they are generally able to perceive the data structure definition corresponding to a MAG. We briefly discuss automatic extraction of structure definitions outlining some of the difficulties in doing so.

97 MATHEMATICS AND COMPUTING↗

There's No Place Like Home: Residential Parking, Electrical Access, and Implications for the Future of Electric Vehicle Charging Infrastructure

In March 2021, the cumulative sale of plug-in electric vehicles (PEVs), including plug-in hybrid electric vehicles (PHEV) and battery electric vehicles (BEV), reached 1.8 million in the United States (Argonne National Laboratory 2021). However, PEV adoption is still in its infancy; its market share has just reached around 3% of new light-duty vehicle (LDV) sales by the end of 2020 (Alliance for Automotive Innovation 2021). Current trends suggest that PEV market share in the United States is increasing. The U.S. Energy Information Administration's (EIA's) 2020 Annual Energy Outlook forecasts PEV registrations to exceed 8 million vehicles by 2030 (AEO 2020). PEV adoption is expected to be led by states that are regulating the sale of zero emission vehicles (ZEVs) (California Air Resources Board). California continues to push for more aggressive ZEV regulations; the state recently issued an executive order aimed at 100% of LDV sales being ZEVs by 2035 (Office of Governor Newsom). At the federal level, the Biden administration has shown great ambition in encouraging broader electric vehicle (EV) adoption, including setting the goal of installing 500,000 new chargers nationwide (The White House 2021). Access to charging infrastructure is consistently cited as one of the primary barriers to the increased sale of PHEVs and BEVs (Carley et al. 2019). In the United States, PEV charging options are often described using a pyramid structure, with residential charging as the foundation, workplace charging in the middle, and public charging on top (Figure 1). The existing electricity system, which generates, transmits, and distributes electric fuel to residential households, has helped PEVs partially overcome the "chicken and egg" conundrum that has haunted other alternative fuels. Viable home access to electric charging is also an important equity issue, because non-residential PEV charging options (e.g., workplace or public charging stations) are generally more expensive. Households without residential charging access may experience higher total cost of PEV ownership if non-residential charging options are more costly.

33 ADVANCED PROPULSION SYSTEMS↗

AOI-2, A Novel Access Control Blockchain Paradigm for Cybersecure Sensor Infrastructure in Fossil Power Generation Systems

Fossil power generation systems are increasingly vulnerable to attack from both cybercriminals as well as internal threats. These vulnerabilities demand that emerging technologies such as blockchains be utilized to secure the data involved in the information flows within the Supervisory Control and Data Acquisition (SCADA) systems of the fossil power generation plants. The publicly accessible blockchain protocols, although secure, are visible to everyone. Even private blockchains currently are unable to support different levels of access to different participants, which is a critical requirement for the existing SCADA systems running the power plants. In light of the above, novel blockchain protocols that are specifically adapted to fossil power generation environments need to be developed in order to achieve the goal of cybersecure sensor networks. In this work, we address this question by creating a novel blockchain technology, namely smart private ledger, for cybersecure communication within the fossil power generation systems. A lab-scale sensor network consisting of strain and temperature sensors is constructed to develop the ledger. The technology has hierarchical access control which is compatible with the existing SCADA systems in fossil power plants. The sensor data is used with cryptographic digital signatures and secret sharing protocols within the nodes of the blockchain technology. The research results will lead to cybersecurity for machine-to-machine interactions, infrastructure for secure data logging for sensors, decentralized data storage, and second-layer technologies for high volume machine-to-machine interactions in the power plants. The work aims to largely address the concerns for the security of distributed sensor networks in such systems that can be compromised by insider threats and by cybercriminals. The research has led to the training of the next generation of engineers and scientists in the important areas of sensor engineering and blockchain technology.

01 COAL, LIGNITE, AND PEAT↗

LA100 Equity Strategies. Chapter 6: Universal Access to Safe and Comfortable Home Temperatures

The LA100 Equity Strategies project integrates community guidance with robust research, modeling, and analysis to identify strategy options that can increase equitable outcomes in Los Angeles' clean energy transition. This chapter focuses on housing weatherization and cooling technologies as means to increase access to safe and comfortable home temperatures. Lack of cooling access and use can have severe health impacts on building occupants during heat waves. Specifically, NREL developed and used a residential building stock model to simulate the energy use of 50,000 dwellings representing the diversity of housing types, appliances, climate zones, and household incomes across Los Angeles. We compared a baseline scenario with seven upgrade scenarios. Five scenarios cooled the entire household and featured cooling systems at varying efficiency levels with various improvements to the envelope, roof, and shading, and two scenarios cooled a single room in a household with no prior cooling using either a room air-conditioning or a heat pump system. For each scenario, we evaluated impacts on utility bills, payback periods, and changes in energy burdens, as well as ability to achieve safe and comfortable temperatures. We also examined the effects of building types (multifamily vs. single-family) on indoor air temperatures. Based on the results of modeling, analysis, and community guidance, we identified six short-term and two long-term strategies for improving access to building envelope upgrades and cooling strategies that could save lives and maintain safe home temperatures for Los Angeles' low-income households during heat waves. Research was guided by input from the community engagement process, and associated equity strategies are presented in alignment with that guidance.

air conditioning↗

Precursor Analysis Report: Remote Access Attack on Oldsmar Water Treatment Facility 2021

The Remote Access Attack on Oldsmar Water Treatment Facility 2021 Precursor Analysis Report leverages publicly available information about the Oldsmar cyber attack and catalogs anomalous observables for each technique employed in the attack. This analysis is based upon the methodology of the Cybersecurity for the Operational Technology Environment (CyOTE) program. On 5 February 2021, an adversary gained unauthorized remote access to Bruce T. Haddock Water Treatment Plant in Oldsmar, Florida, which provides treated water to 15,000 customers. The adversary accessed the facility’s Supervisory Control and Data Acquisition (SCADA) workstation and human machine interface (HMI) to change the chemical concentration of sodium hydroxide, commonly referred to as lye and used to regulate acidity levels, from 100 parts per million (PPM) to 11,100 PPM. The chemical was raised to lethal levels that if ingested could lead to serious soft tissue damage, burns, or even death. The facility, however, had redundancies and alarms in place to alert personnel of dangerous chemical levels, and facility officials stated it would have taken 24 to 36 hours for the chemical changes to affect the water supply. Researchers and analysts identified six unique techniques utilized during the attack with a total of 23 observables using MITRE ATT&CK® for Industrial Control Systems. The CyOTE program assesses observables accompanying techniques used prior to the triggering event to identify opportunities to detect malicious activity. If observables accompanying the attack techniques are perceived and investigated prior to the triggering event, earlier comprehension of malicious activity can take place. Four of the identified techniques used during the Oldsmar cyber attack were precursors to the triggering event. Analysis identified 21 observables associated with these precursor techniques, 20 of which were assessed to have an increased likelihood of being perceived in the minutes preceding the triggering event. The response and comprehension time could have been reduced if the observables had been identified earlier. The information gathered in this report contributes to a library of observables tied to a repository of artifacts, data sources, and technique detection references for practitioners and developers to support the comprehension of indicators of attack. Asset owners and operators can use these products if they experience similar observables or to prepare for comparable scenarios.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Evaluating the Curtailment Risk of Non-Firm Utility-Scale Solar Photovoltaic Plants under a Novel Last-In First-Out Principle of Access Interconnection Agreement

With the increasing share of distributed energy resources on the electric grid, utility companies are facing significant decisions about infrastructure upgrades. An alternative to extensive and capital-intensive upgrades is to offer non-firm interconnection opportunities to distributed generators, via a coordinated operation of utility scale resources. This paper introduces a novel flexible interconnection option based on the last-in, first-out principles of access aimed at minimizing the unnecessary non-firm generation energy curtailment by balancing access rights and contribution to thermal overloads. Although we focus on solar photovoltaic (PV) plants in this work, the introduced flexible interconnection option applies to any distributed generation technology. The curtailment risk of individual non-firm PV units is evaluated across a range of PV penetration levels in a yearlong quasi-static time-series simulation on a real-world feeder. The results show the importance of the size of the curtailment zone in the curtailment risk distribution among flexible generation units as well as that of the “access right” defined by the order in which PV units connect to the grid. Case study results reveal that, with a proper selection of curtailment radius, utilities can reduce the total curtailment of flexible PV resources by up to more than 45%. Findings show that non-firm PV generators can effectively avoid all thermal limit-related upgrade costs.

14 SOLAR ENERGY↗

EPA GHG certification of medium- and heavy-duty vehicles: Development of road grade profiles representative of US controlled access highways

In collaboration with the U.S. Environmental Protection Agency and the U.S. Department of Energy, the National Renewable Energy Laboratory has conducted a national analysis of road grade characteristics experienced by U.S. medium- and heavy-duty trucks on controlled access highways. These characteristics have been developed using TomTom's commercially available street map and road grade database. Using the TomTom national road grade database, national statistics on road grade and hill distances were generated for the U.S. network of controlled access highways. These statistical distributions were then weighted using data provided by the U.S. Environmental Protection Agency for activity of medium- and heavy-duty trucks on controlled access highways. Here, the national activity-weighted road grade and hill distance distributions were then used as targets for development of a handful of sample grade profiles potentially to be used in the U.S. Environmental Protection Agency's Greenhouse Gas Emissions Model certification tool as well as in dynamometer testing of medium- and heavy-duty vehicles and their powertrains.

30 DIRECT ENERGY CONVERSION↗

The impact of changing the land surface scheme in ACCESS(v1.0/1.1) on the surface climatology

The Community Atmosphere Biosphere Land Exchange (CABLE) model has been coupled to the UK Met Office Unified Model (UM) within the existing framework of the Australian Community Climate and Earth System Simulator (ACCESS), replacing the Met Office Surface Exchange Scheme (MOSES). Here we investigate how features of the CABLE model impact on present-day surface climate using ACCESS atmosphere-only simulations. The main differences attributed to CABLE include a warmer winter and a cooler summer in the Northern Hemisphere (NH), earlier NH spring runoff from snowmelt, and smaller seasonal and diurnal temperature ranges. The cooler NH summer temperatures in canopy-covered regions are more consistent with observations and are attributed to two factors. Firstly, CABLE accounts for aerodynamic and radiative interactions between the canopy and the ground below; this placement of the canopy above the ground eliminates the need for a separate bare ground tile in canopy-covered areas. Secondly, CABLE simulates larger evapotranspiration fluxes and a slightly larger daytime cloud cover fraction. Warmer NH winter temperatures result from the parameterization of cold climate processes in CABLE in snow-covered areas. In particular, prognostic snow density increases through the winter and lowers the diurnally resolved snow albedo; variable snow thermal conductivity prevents early winter heat loss but allows more heat to enter the ground as the snow season progresses; liquid precipitation freezing within the snowpack delays the building of the snowpack in autumn and accelerates snow melting in spring. Altogether we find that the ACCESS simulation of surface air temperature benefits from the specific representation of the turbulent transport within and just above the canopy in the roughness sublayer as well as the more complex snow scheme in CABLE relative to MOSES.

54 ENVIRONMENTAL SCIENCES↗

Access to pedestal pressure relevant to burning plasmas on the high magnetic field tokamak Alcator C-Mod

Experiments on the Alcator C-Mod tokamak have utilized reactor-relevant magnetic fields to sustain substantially higher pedestal pressure than in other devices and allow close approach to the ITER H-mode baseline target pedestal pressure of 90 kPa. The EPED model, which couples the physics of transport driven by kinetic ballooning modes and MHD instabilities arising from peeling-ballooning modes, predicts the pressure profile at the onset of edge-localized modes (ELMs), and yields to lowest order a critical-βN like behavior for the pedestal: p∝Bt×Bp ( ∝Bt^2 for fixed edge q). C-Mod routinely accesses edge plasma pressure in excess of 30 kPa, often by using a high-density (ne>3×10^20 m^-3) approach to high confinement, taking advantage of a regime known as enhanced D-alpha (EDA) H-mode. In the EDA H-mode, plasma transport regulates both the pedestal profiles and the core impurity content, thus holding the pedestal stationary at just below the peeling-ballooning stability boundary. This stationary ELM-suppressed regime has approached the maximum pedestal predicted by EPED at these densities: 60 kPa. This in turn gives rise to volume-averaged core plasma pressure in excess of 0.2MPa, a world record value for a magnetic fusion device. Another approach to achieving high pressure utilizes a pedestal limited by current-driven modes at low collisionality, in which pressure increases with density and which allows access to a higher EPED solution, termed “super-H”. C-Mod experiments at reduced density (ne<2×10^20 m^-3) and strong plasma shaping (δ>0.5) accessed this regime, producing pedestals with pressures up to 80kPa (approximately 90% of the ITER target) and temperatures of nearly 2 keV. In a number of these hot H-modes, we observe strong edge instabilities at low toroidal mode number (n=1) when pedestal pressure approaches predicted values from EPED, showing that current-driven MHD modes can serve as a limit on the pedestal in a metal-walled tokamak at high pressure and low collisionality.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Proposed preliminary criteria for space shuttle access equipment at the operational site

A comparison was made between the methods of access utilized, or proposed, by the military, commercial airlines, and the space shuttle Phase B contractors. The methodology was subjected to consideration for space shuttle use and similarity to current space shuttle access concepts. The Phase B contractor concepts were in turn examined for degree of use of the state-of-the-art and progressive extension of new cost-effective ideas. This comparison disclosed a need for better definition of the criteria/requirements for space shuttle access equipment. Preliminary criteria, needed prior to initiation of the detail design (Phase C/D effort) of ground hardware for the operational site, are presented.

Beck, P. E.↗

Magnetospheric access of solar particles and the configuration of the distant geomagnetic field, volume 1

The access of 1.2 to 40 MeV protons and 0.4 to 1.0 MeV electrons from interplanetary space to the polar cap regions was investigated with an experiment on board a low altitude, polar-orbiting satellite (0G0 4). A total of 333 quiet time observations of the electron polar cap boundary give a mapping of the boundary between open and closed geomagnetic field lines. Observations of events associated with co-rotating regions of enhanced proton flux in interplanetary space were used to establish the characteristics of the 1.2 to 40 MeV proton access windows. The results were compared to particle access predictions of the distant geomagnetic tail configurations. The role played by interplanetary anisotropies in the observation of persistent polar cap features is discussed. Special emphasis is given to the problem of nonadiabatic particle entry through regions where the magnetic field is changing direction.

Evans, L. C.↗

Acceptance test report (MI-74067-009-00). SVWS access arm (Serial number AA-09-03) (drawing 75M08129-13)

Acceptance tests were conducted at Kennedy Space Center of the Saturn Vehicle Workshop Spacecraft Access Arm and related equipment. The tests were conducted to prove complete system capability to operate satisfactorily under conditions required to support spacecraft operations and activities. The SVWS Access Arm, serial number AA-09-03, is a Command Module Service Arm, S/A 9, which was removed from the mobile launcher and modified to support the SVWS operations. The C/M environmental chamber was removed and a completely new chamber was installed. The retract system was redesigned to remove the automatic/remote control capability and replaced with a local manual control. The SVWS Access Arm System was successfully tested and supported spacecraft processing without major problems.

Hagood, J. T.↗

Random-access technique for modular bathymetry data storage in a continental shelf wave refraction program

A study was conducted of an alternate method for storage and use of bathymetry data in the Langley Research Center and Virginia Institute of Marine Science mid-Atlantic continental-shelf wave-refraction computer program. The regional bathymetry array was divided into 105 indexed modules which can be read individually into memory in a nonsequential manner from a peripheral file using special random-access subroutines. In running a sample refraction case, a 75-percent decrease in program field length was achieved by using the random-access storage method in comparison with the conventional method of total regional array storage. This field-length decrease was accompanied by a comparative 5-percent increase in central processing time and a 477-percent increase in the number of operating-system calls. A comparative Langley Research Center computer system cost savings of 68 percent was achieved by using the random-access storage method.

Poole, L. R.↗

Components of the airport access system

The organizations and agencies which make up or influence the airport access system are examined. These include the airport, the airline industry, the public and private transit agencies which provide ground access to the airport, and the regulatory agencies which affect all of these organizations and their actions. Each component, with the exception of the regulatory agencies is described in terms of its legal status, its sources of funds, and the nature of its relationship with the other components. Conclusions regarding the system components' effects on airport access and recommendations for changes which appear practical are presented.

Source record↗

Role of helicopters in airport access

The paper briefly reviews the role of helicopter systems in the provision of airport access services and evaluates the potential for the future development of such services in major metropolitan areas in the United States. The evaluation is based on a computer simulation of potential helicopter system proposed for 20 metropolitan areas. The simulation provides two indicators that are used to gage the extent of the feasibility of developing successful systems in these areas: (1) the cost per seat mile, and (2) the break-even number of passengers, expressed as a percentage of total air travelers. It is found that a few metropolitan areas presently have the potential of marginally supporting intra-urban helicopter airport access service. The access systems offer a viable alternative for air passengers placing a high value on their time, and provides the opportunity for better integrating the air transportation service of multiple airports in a given urban region.

Dajani, J. S.↗