Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ASHRAE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

A Methodology to Create Prototypical Building Energy Models for Existing Buildings: A Case Study on U.S. Religious Worship Buildings

Prototypical building energy models are of great significance because they are the starting point in conducting analyses for various applications, such as building energy saving potential analysis, building design, building energy market evaluation, and building energy policy-making. However, current prototypical building energy models only represent limited types of buildings in certain countries. To fill the gap, this paper proposes a methodology to systematically create prototypical building energy models. First, a six-step methodology is introduced: model input identification, data collection, data cleaning, data conversion, model simulation, and model calibration. Then, the methodology is demonstrated by a case study of creating 30 prototypical energy models for U.S. religious worship buildings, representing buildings in 15 climate zones and 2 vintages (pre- and post-1980). Finally, to show the applications of the models, the building energy saving potentials from six efficiency measures are analyzed for pre-1980 U.S. religious worship buildings in three ASHRAE Climate Zones. The results show that the maximum energy saving potentials are approximately 30% for the religious worship buildings in all three climate zones investigated.

prototype building model, building simulation, Bui↗

Prototype energy models for data centers

Data centers in the United States consume about two percent of the nation’s electricity. Because heat gains from IT equipment drive cooling demand, data centers offer unique opportunities for energy savings. However, no prototype energy model for data centers is available in the suite of existing U.S. Department of Energy’s Commercial Prototype Building Models. Here we present the development of two new data center prototype models and their implementation in OpenStudio and EnergyPlus. The small-size data center model represents a computer room in a building served by computer room air conditioners (CRACs); while the large-sized model represents stand-alone data centers served by computer room air handlers (CRAHs) with a central chiller plant. For each data center model, two levels of IT equipment (ITE) load density were considered, to cover the wide range of IT power density of data centers: 40 and 100 W/ft 2 (430 and 1076 W/m 2 ) for the computer room, and 100 and 500 W/ft 2 (1076 and 5382 W/m 2 ) for the stand-alone data center. All other assumptions, such as building envelope, lighting, HVAC efficiencies and schedules, were based on the minimal requirements of ASHRAE Standard 90.1 at various vintages. We introduced a novel concept of supply and return air approach temperatures to capture the essential effects of non-uniform airflow and temperature distribution in data centers. The approach temperatures were pre-computed by computational fluid dynamics (CFD) simulations for various configurations of ITE loads and airflow containment management in data centers. A new feature was developed in EnergyPlus to implement the approach temperature method. A case study was conducted to demonstrate the use of the data center models. The two data center models cover all U.S. climate zones and can be used to evaluate energy saving measures for data centers, as well as to support development of data center energy efficiency codes and standards.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

What are the Impacts on the HVAC System when it Provides Frequency Regulation? – A Comprehensive Case Study with a Multi-Zone Variable Air Volume (VAV) System

Heating, ventilation, and air-conditioning (HVAC) systems in commercial buildings have proven to be a great asset for providing secondary frequency regulation (FR) service to the power grid. However, how the provision of FR service affects the HVAC system Quality of Service (QOS) is still largely unknown. In particular, there exists a controversy regarding the energy efficiency impact. This paper investigates how a HVAC system performance and its associated controls are impacted during and after the FR service. For the assessment, we developed a dynamic Modelica-based medium office building model as a virtual testbed with the Air Handling Unit (AHU) fans providing the FR service. Different regulation capacities (demand levels) and standard test signals under various load profiles in the U.S. are considered. The results show that FR has little or no impact on the HVAC operation and occupant thermal comfort while the building is providing the service if an appropriate regulation capacity is pre-determined. However, if the regulation capacity is overestimated, the quality of the FR service provided by the HVAC system and the HVAC energy efficiency will be affected due to the equipment operating constraints. In addition, the AHU supply air temperature fluctuates, and the controller cannot maintain the desired setpoint as the FR magnitude is increased. After the FR service time, the system takes a certain period to return to normal operation. The recovery period extends with the increase in the FR magnitude. For this case study, there exists a control conflict between the FR control and the existing HVAC control (from ASHRAE Guideline 36-2018) during high load conditions, causing the fan speed to saturate. The fan power consumption could increase significantly; up to 77% increase compared to the baseline was observed. This case study demonstrates that the HVAC system controls need to be enhanced and adapted to minimize the interaction between the FR controller and the indoor environmental controls in order to preserve the HVAC system QOS while (during and after) providing satisfactory FR service.

Lu, Xing↗

Methodology to evaluate design modifications intended to eliminate frosting and high discharge temperatures in air-source heat pumps (ASHPs) in cold climates

Air-source heat pumps (ASHPs) operating in cold climates experience problems with frosting and high refrigerant temperatures. These problems increase energy consumption, and their severity depends on the climatic conditions. In the present paper, a methodology for identifying the prevailing problem between frosting and high discharge temperatures is presented. Three performance indices, the frosting index (FI), the discharge index (DI), and the total loss index (TLI), are proposed to quantify the impacts of frosting and high discharge temperatures on the annual performance of ASHPs in different climatic conditions. The FI and DI show which problem (frosting or high discharge temperature) dominates, and the TLI indicates the combined effect of frosting and high discharge temperatures on the performance of an ASHP. A thermodynamic model of an ASHP coupled with the TRNSYS building simulation tool is used to estimate the performance of an ASHP and the proposed loss indices to estimate the impact of both frosting and high discharge temperatures for 45 cities in Canada. The results can be extended to other parts of the world that experience similar climatic conditions The results reveal that in cities in ASHRAE climatic zones 5 and 6 (classified as cold regions) where the ambient air temperatures are predominantly between -15 °C to 6 °C, ASHPs are heavily impacted by frosting. The problem of high discharge temperatures in ASHPs is predominant in cities in climate zones 7 and 8 (classified as very cold and subarctic regions) where the temperatures are frequently below -20 °C in winter. Among the cities considered, St. John, NL has the highest fraction of heating hours experiencing frosting (90 %), where the annual increase in energy consumption due to frosting is 13.5 % of the annual heating energy consumption. The highest annual increase in energy consumption due to high discharge temperatures is in Isachsen, NU (zone 8), where the increase is 30 % of the annual heating energy consumption. Based on the proposed indices, another index called the performance gain index (PGI) is created, which can be used as a first step to assess the energy-saving potential of design modifications applied to ASHPs to solve the problems of frosting and high discharge temperatures. The PGI will aid in developing climate specific ASHPs. One possible design modification is the use of a two-stage ASHP with an economizer. It is observed that the two-stage ASHP with economizer can mitigate high discharge temperatures and improve performance in very cold and subarctic regions (zones 7 and 8). However, it is not as beneficial in zones 5 and 6, where the impact of high discharge temperatures on performance is minimal and frosting dominates. Finally, a case study, using the PGI to evaluate the economic and environmental effectiveness of a two-stage ASHP with economizer is presented for the city of Saskatoon.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy characteristics of multi-chiller load distribution algorithms in a large office building

Here, this study evaluates the energy efficiency of multi-chiller systems in large office buildings, focusing on their optimization across various climate zones as defined by ASHRAE. Using EnergyPlus for simulations, the research examines five different load distribution algorithms in multi-chiller systems that range from one to ten chillers, aiming to understand their effectiveness in 15 distinct climate zones. The primary objectives of the study include identifying the energy efficiency of multi-chiller systems in each climate zone, determining the appropriate number of chillers for each zone, and evaluating the performance of the load distribution algorithms. Based on the U.S. Department of Energy’s commercial building model, the results suggest that multi-chiller systems can significantly reduce cooling energy consumption in various climates. Among the algorithms evaluated, the Sequential Uniform Part Load Ratio (SUPLR) algorithm demonstrates notable efficiency, especially in the 4A climate zone (Baltimore), where it achieves substantial energy savings. Applying the SUPLR algorithm in a multi-chiller setup with four chillers in this zone leads to an estimated 24.5 % reduction in energy usage, equivalent to 183 MW annually. The research indicates that a range of 3 to 5 chillers is typically optimal for most climate zones. In-depth analysis in the 4A climate zone highlights the importance of minimizing operation hours at low Part Load Ratios (PLR) to ensure that chillers operate at a high Coefficient of Performance (COP). This strategy underscores the potential of well-designed multi-chiller systems to reduce cooling energy demand, particularly in climates with transitional seasons. This study provides an overview of the energy-saving potential of multi-chiller systems, applicable across a variety of climatic scenarios.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of hybrid evaporative-vapor compression air conditioners for different global climates

Currently, a majority of global residential air-conditioning requirements are met using cooling systems based on the vapor compression cycle (VCC). To meet the future demand for space cooling and to reduce the corresponding environmental impact, there is a need for alternative cooling systems which require less resources and exhibit a higher coefficient of performance (COP). One of proposed alternatives is called the hybrid evaporative-vapor compression (HEVC) cycle, which utilizes adiabatic latent cooling in combination with the VCC. In this paper, we conducted a feasibility analysis of a HEVC system by comparing its performance to that of VCC for various global climates. To accomplish this, we developed and validated models to simulate the performance of residential VCC and HEVC systems. ASHRAE weather data and design conditions were then used to compare the performance of the two systems. In general, HEVC systems are best suited for hot arid climates with energy reduction greater than 20%. Conversely, humid climates are not suitable for HEVC adoption due to degraded performance of evaporative coolers in these climates. In addition to comparing the energy savings from HEVC systems, it is also critical to analyze their water consumption. Generally, climates that benefit the most from HEVC technology tend to also experience water scarcity issues. Thus, both the energy savings and water consumption of HEVC systems must be analyzed to guide the discussion on their adoption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development and application of a statistical methodology to evaluate the predictive accuracy of building energy baseline models

This paper documents the development and application of a general statistical methodology to assess the accuracy of baseline energy models, focusing on its application to Measurement and Verification (M&V) of whole-­building energy savings. The methodology complements the principles addressed in resources such as ASHRAE Guideline 14 and the International Performance Measurement and Verification Protocol. It requires fitting a baseline model to data from a ``training period’’ and using the model to predict total electricity consumption during a subsequent ``prediction period.’’ We illustrate the methodology by evaluating five baseline models using data from 29 buildings. The training period and prediction period were varied, and model predictions of daily, weekly, and monthly energy consumption were compared to meter data to determine model accuracy. Several metrics were used to characterize the accuracy of the predictions, and in some cases the best-­performing model as judged by one metric was not the best performer when judged by another metric.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

How will United States commercial building energy use be impacted by IPCC climate scenarios?

Climate change and anthropogenically-forced shift of weather in the future will impact energy use and resilience of both the built environment and the electric grid. The aim of this analysis is to understand how future climate scenarios will impact electricity and natural gas use of commercial buildings in the United States. Here, this study analyzes this impact for 2030, 2045, and 2100 using Representative Concentration Pathways (RCP) scenarios defined in Intergovernmental Panel on Climate Change (IPCC) Assessment Report 5. The large, gridded simulation of meteorological variables for RCPs 2.6, 4.5, 6.0, and 8.5 are selected and downscaled to make available hourly Future Meteorological Year (FMY) weather files for use and improvement in subsequent studies. High performance computing resources use these FMYs to simulate commercial prototype buildings in every American Society of Heating, Refrigeration, and Air Conditioning Engineers (ASHRAE) climate zone of the United States (US), and results are scaled to nation-wide energy use using conditioned floor area multipliers. The analysis is conducted without speculating the physical and performance traits of future buildings or the grid characteristics. This analysis quantifies the impact of climate change on source electrical and natural gas usage for commercial buildings in the United States over the next 80 years. If US commercial floorspace remained constant, total energy use by 2100 is predicted between an 1.75% decrease under the greatest emission scenario (8.5) and a 1.76% increase under the lowest emission scenario (2.6). When adjusted for anticipated urban growth by 2100, the predicted range is 65% increase (8.5) and 71% increase (2.6). Under a global temperature rise climate scenario, the warmest US climate zones will see a large increases in electricity use derived from space cooling while the coldest US climate zones will see significant decreases in natural gas use caused by the decrease in heating necessary. While climate change may ultimately require adaptations of the built environment to withstand its effects and because the United States is a country that requires more heating than cooling, from a building energy perspective, climate change (average temperature rise) is a net energy saver for the United States.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simulation of effects of direction and air flow speed on temperature distribution in the room covered by various roof materials

The objective of this research is to get a comparison of the distribution of the room temperature by using three materials, namely plastic-rubber composite, clay, and asbestos. The simulation used Ansys Fluent to get the temperature distribution. There were two conditions in this simulations, first the air passing beside the room and second the air passing in front of the room. Each condition will be varied with the air speed of 1 m/s, 2 m/s, 3 m/s, 4 m/s, 5 m/s for each material used. There are three heat transfers in this simulation, namely radiation, convection, and conduction. Based on the ANSI/ ASHRAE Standard 55-2004, the results of the simulation showed that the best temperature distribution was the roof of plastic-rubber composites.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A high-fidelity building performance simulation test bed for the development and evaluation of advanced controls

We present an open-source building performance simulation test bed, the Advanced Controls Test Bed (ACTB), that interfaces high-fidelity Spawn of EnergyPlus building models, with advanced controllers implemented in Python. Additionally, the ACTB leverages the Building Optimization Testing and Alfalfa platforms for managing simulations, providing an external clock, a representational state transfer (REST) application programming interface (API), and key performance indicators for evaluating the effectiveness of control strategies. The REST API allows the development of external controllers programmed in languages such as Python, which provides flexibility and a rich choice of scientific libraries for designing control sequences. We present three test cases based on the U.S. Department of Energy's Reference Small Office Building to demonstrate the ACTB's capabilities: (a) rule-based controls compliant with ASHRAE Guideline 36 control sequences; (b) an economic model predictive control implemented using do-mpc; and (c) a deep Q-network reinforcement learning agent implemented using OpenAI Gym.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling of transient conduction in building envelope assemblies: A review

As buildings age, retrofits are becoming an increasingly important topic for the ever-growing and aging existing building stock. To compare designs or evaluate in-service building envelopes, thermal modeling is utilized to evaluate the thermal performance of envelope assemblies; however, it can be difficult to model the thermal performance of as-built assemblies due to degradation or missing documentation. To address this issue, inverse modeling can be applied to infer the properties of as-built envelope assemblies. This paper presents a review of the literature and published methods to model and infer the transient conductive performance of building envelopes. This review serves as a survey of existing transient conduction algorithms to evaluate performance, computational speed, and relevance for inverse modeling applications. In addition to the literature review, this work also evaluates the computational performance of the most prevalent transient conduction algorithms against the ASHRAE 1052RP toolkit to assess inverse modeling potential. This methodology serves as a foundation for future research to characterize the transient thermal performance of as-built building envelope assemblies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

On-policy learning-based deep reinforcement learning assessment for building control efficiency and stability

Artificial intelligence technologies have emerged as a game changer not only in specific applications such as image recognition and machine translation but also in many scientific domains. In particular, as deep reinforcement learning (DRL) has shown great success in complex control problems, DRL-based control has been considered as a potential solution to efficiently control and manage building systems. However, broad assessment of DRL-based building control is still required to characterize their pros and cons in comparison with conventional building control methods (e.g., rule-based feedback controls). In this paper, we assessed DRL-based controls with on-policy learning-based algorithms and continuous control actions for cooling control of large office buildings in the summer season to minimize whole-building energy use and occupant discomfort. We compared DRL-based control methods with two baseline control methods: (1) a pre-determined schedule with supply temperature and static pressure setpoints, and (2) advanced reset method that adjusts setpoints based on heuristic rules, i.e., ASHRAE Guideline 36. We also tested the DRL algorithms to evaluate their performances in multiple climate locations. We found that DRL-based control methods outperformed the baseline control methods in terms of energy savings while maintaining a thermal comfort. DRL reduced energy use between ~4%–22% on average compared to the baseline methods, depending on climate location. We also evaluated DRL-based control in terms of control stability and showed that DRL-based methods should address the span of hardware lifetimes in practical operations.

control stability↗

Chemical stability investigation of haloolefin refrigerants and their blends with lubricants

This paper examines the findings of highly accelerated life tests (HALT), conducted according to ASHRAE Standard 97 sealed glass tube methodology for R-123 like, R-134a like and R-410A/R-404A like lower global warming potential (GWP) alternatives. Additionally, possible chemical breakdown pathways are reviewed for the new haloolefin refrigerants. Note, compositions for the following blends are shown as percent by weight. For R-123 like refrigerants, R-1336mzz(Z), R-1336mzz(E), R-514A (74.7% R-1336mzz(Z)/25.3% R-1130(E)), R-1233zd(E), and R-1224yd(Z) were examined with and without lubricants. R-1233zd(E) and R-1224yd(Z) were evaluated with mineral oil and the rest were evaluated with polyalkylene glycol (PAG), polyolester (POE) and polyvinyl ether (PVE) lubricants. For R-134a like refrigerants, R-1234ze(E), R-450A (42% R-134a/58% R-1234ze(E)), R-515B (91.1% R-1234ze(E)/8.9% R-227ea), R-1234yf, R-513A (56% R-1234yf/44% R-134a), and R-516A (77.5% R-1234yf/8.5% R-134a/14.0% R-152a) were examined with and without PAG, POE, and PVE lubricants. For R-410A/R-404A like, R-454B (68.9% R-32/31.1% R-1234yf), R-454C (21.5% R-32/78.5% R-1234yf), R-455A (3.0% R-744/21.5% R-32/75.5% R-1234yf), and R-468A (3.5% R-1132a/21.5% R-32/75.0% R-1234yf) were also examined with PAG, POE and PVE lubricants. R-466A (49% R-32/11.5% R-125/39.5% CF 3 I) was part of this study but will not be covered since it does not contain a haloolefin component.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Model-based data center cooling controls comparative co-design

This article presents a comparative simulation-based control logic design process. It uses the Control Description Language (CDL) and the ASHRAE Guideline 36 high-performing building control sequences with the Modelica Buildings Library (MBL) to demonstrate a comparative analysis of two control designs for a data center chilled water plant. Details include a description of the closed-loop plant and control design methodology, including sizing and parameterization, base and alternative (Guideline 36) control logic with software implementation structure, and outline of the simulation experimentation process. The selected control designs are paired with comparable chilled water plant configurations. The models include a chiller, a water-side economizer, and an evaporative cooling tower. The plant provides cooling at 27ºC zone supply air temperature to a data center in Sacramento, CA. The comparative simulation results examined the impacts of a selected control logic detail, and present an example model-based design application. Overall, the simulation results showed a 25% annual and a 18% summer energy use reduction for alternative controls. This shows that simulation-based control logic design performance evaluation can improve energy efficiency and resilience aspects of system controls at large.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Tau energy loss and ultrahigh energy skimming tau neutrinos

For this paper, we consider propagation of high-energy earth-skimming taus produced in interactions of astrophysical tau neutrinos. For astrophysical tau neutrinos, we take generic power-law flux, E -2 and the cosmogenic flux initiated by the protons. We calculate tau energy loss in several approaches, such as dipole models and the phenomenological approach in which parametrization of the F 2 is used. We evaluate the tau neutrino charged-current cross section using the same approaches for consistency. We find that uncertainty in the neutrino cross section and in the tau energy loss partially compensate giving very small theoretical uncertainty in the emerging tau flux for distances ranging from 2 to 100 km and for the energy range between 10 6 and 10 11 GeV , focusing on energies above 10 8 GeV . When we consider uncertainties in the neutrino cross section, inelasticity in neutrino interactions and the tau energy loss, which are not correlated, i.e. they are not all calculated in the same approach, theoretical uncertainty ranges from about 30% and 60% at 10 8 GeV to about factors of 3.3 and 3.8 at 10 11 GeV for the E -2 flux and the cosmogenic flux, respectively, for the distance of 10 km rock. The spread in predictions significantly increases for much larger distances, e.g., ~ 1,000 km . Most of the uncertainty comes from the treatment of photonuclear interactions of the tau in transit through large distances. We also consider Monte Carlo calculation of the tau propagation and we find that the result for the emerging tau flux is in agreement with the result obtained using analytic approach. Our results are relevant to several experiments that are looking for skimming astrophysical taus, such as the Pierre Auger Observatory, HAWC and Ashra. We evaluate the aperture for the Auger and discuss briefly application to the other two experiments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A NUMERICAL STUDY OF REFRIGERANT LEAKAGE FROM A PROPANE-BASED REFRIGERATION SYSTEM

Low Global Warming Potential (GWP) refrigerants, e.g. Propane (R290) (GWP = 3) and R1234yf (GWP = 4), are becoming a popular choice among refrigeration and HVAC systems, such as vending machines and air conditioning. However, most of Low GWP refrigerants are flammable (ASHRAE class A2 or A3), so safety is a very important consideration when designing and deploying low GWP refrigerants-based equipment in buildings. In the event of a refrigerant leak, the flammability of low GWP refrigerants depends on the local concentration of the refrigerant within the vicinity of the leak. In addition, the low GWP refrigerants concentration is affected by the indoor air environment, such as air flow rate and temperature. In the present study, a computational fluid dynamics (CFD) model is developed to model the flow and temperature of air surrounding a propane-based refrigeration system, as well as the concentration of leaked low GWP refrigerants surrounding the refrigeration system. The model results reveal the concentration distribution of low GWP refrigerants within the building, and as a result, the flammable regions within the building can be identified. Moreover, different ventilation layouts will be tested using the model to improve the design of ventilation. The numerical model can assist in the design of ventilation systems to minimize flammable regions within buildings due to leakage of flammable refrigerants.

Zhang, Mingkan↗

Ontologies at Work: Analyzing Information Requirements for Model Predictive Control in Buildings

Model Predictive Control (MPC) has shown significant potential for improving energy efficiency, indoor air quality and occupant comfort of buildings. MPC-based control algorithms have also shown the ability to shift loads and optimize for multiple objectives, including but not limited to reducing the green-house gas emissions, energy costs and peak demand. However, one of the main implementation challenges of these control algorithms is the integration and configuration effort needed to deploy a supervisory MPC controller in a building. By assigning standardized references to information sources and control points in buildings, existing studies have shown that semantic ontologies and corresponding queries have the potential to ease the deployment of such controllers. Yet, the use of semantic information to ease the deployment processes of MPC controllers is still limited. In this paper, we review three MPC experiments and synthesize the information requirements of these optimization problems. We then turn to existing and upcoming semantic ontologies such as Brick, SAREF and ASHRAE Standard 223 to represent these requirements, evaluating their potential to support the implementation of an MPC controller. This investigation concludes with a discussion of existing opportunities and open questions that the community should explore to support more streamlined MPC implementations.

Prakash, Anand Krishnan↗

I Can’t Read All That! Improving the Usability of Semantic Models Using Concise, Ontology-Agnostic, Building-Specific Schemas

Semantic ontologies have enabled the creation of formalized, machine-readable descriptions of heterogenous building systems by providing dictionaries of well defined concepts that can be applied to model them. Within a semantic model of a particular building, a subset of an ontology's concepts may be applied in different ways to represent a particular perspective of the building's systems. How the concepts were applied can only be understood by examining the large amount of instance data within a semantic model, which leads to usability challenges. We propose a concise, ontology-agnostic method for defining building-specific schema (b-schema) graphs that summarize the structure and content of a semantic model. This approach provides a queryable and concise representation of the model's contents, separate from the instance data within a model, that can mitigate the challenges posed by the size and complexity of semantic models in processes such as visualization, querying, validation, and the use of large language models (LLMs). We validate our approach on semantic models based on the Brick and ASHRAE S223 ontologies. Results demonstrate that b-schemas significantly reduce the complexity of visual interpretation, accelerate SPARQL queries and SHACL validation, and improve LLM-based knowledge graph question answering.

Paul, Lazlo [Lawrence Berkeley National Laboratory↗