Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ANIMALS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Software Validation via Model Animation

This paper explores a new approach to validating software implementations that have been produced from formally-verified algorithms. Although visual inspection gives some confidence that the implementations faithfully reflect the formal models, it does not provide complete assurance that the software is correct. The proposed approach, which is based on animation of formal specifications, compares the outputs computed by the software implementations on a given suite of input values to the outputs computed by the formal models on the same inputs, and determines if they are equal up to a given tolerance. The approach is illustrated on a prototype air traffic management system that computes simple kinematic trajectories for aircraft. Proofs for the mathematical models of the system's algorithms are carried out in the Prototype Verification System (PVS). The animation tool PVSio is used to evaluate the formal models on a set of randomly generated test cases. Output values computed by PVSio are compared against output values computed by the actual software. This comparison improves the assurance that the translation from formal models to code is faithful and that, for example, floating point errors do not greatly affect correctness and safety properties.

Dutle, Aaron M.↗

High-precision Method for Cyclic Loading of Small-Animal Vertebrae to Assess Bone Quality

One potentially important bone quality characteristic is the response of bone to cyclic (repetitive) mechanical loading. In small animals, such as in rats and mice, cyclic loading experiments are particularly challenging to perform in a precise manner due to the small size of the bones and difficult-to-eliminate machine compliance. Addressing this issue, we developed a precise method for ex vivo cyclic compressive loading of isolated mouse vertebral bodies. The method has three key characteristics: 3D-printed support jigs for machining plano-parallel surfaces of the tiny vertebrae; pivotable loading platens to ensure uniform contact and loading of specimen surfaces; and specimen-specific micro-CT-based finite element analysis to measure stiffness to prescribe force levels that produce the same specified level of strain for all test specimens. To demonstrate utility, we measured fatigue life for three groups (n = 5-6 per group) of L5 vertebrae of C57BL/6J male mice, comparing our new method against two methods commonly used in the literature. We found reduced scatter of the mechanical behavior for this new method compared to the literature methods. In particular, for a controlled level of strain, the standard deviation of the measured fatigue life was up to 5-fold lower for the new method (F-ratio = 4.9; p < 0.01). The improved precision for this new method for biomechanical testing of small-animal vertebrae may help elucidate aspects of bone quality.

Bone quality↗

Translational Cell & Animal Research in Space 1965-2011

Translational Cell and Animal Research (TCAR). For nearly 50 years, the NASA Space Biology Program has funded, and Ames Research Center (ARC) has managed, a robust program of fundamental research including studies using a wide range of animal cells, tissues and organisms. Much of this research was conducted on spacecraft in microgravity environments including diverse platforms such as: Gemini Spacecraft, US Biosatellites, Apollo Command Modules, Skylabs, Russian Biosatellites, NASA Space Shuttles, NASA/Mir, and most recently, the International Space Station (ISS). During the Space Shuttle Era (1981–2011), the science of space biology took an enormous step forward with 45 missions that afforded researchers with new opportunities to conduct systematic and complex experiments aimed at a deeper understanding of how life adapts to the space environment. Beginning in the 1990s, the products of these experiments, comprised of research summaries and rare, unused biospecimens, were collected and catalogued within the ARC Life Sciences Data Archiving Office, a branch of NASA’s Life Sciences Data Archive (LSDA) managed from the NASA Johnson Spaceflight Center.

Ronca, April E.↗

NASA GeneLab Platform Utilized for Biological Response to Space Radiation in Animal Models

Ionizing radiation from Galactic Cosmic Rays (GCR) is one of the major risk factors that will impact the health of astronauts on extended missions outside the protective effects of Earth’s magnetic field. The NASA GeneLab project has detailed information on radiation exposure using animal models with curated dosimetry information for spaceflight experiments. We analyzed multiple GeneLab omics datasets associated with both ground-based and spaceflight radiation studies that included in vivo and in vitro approaches. A range of ions from protons to iron particles with doses from 0.1 Gy to 1.0 Gy for ground studies and samples flown in Low Earth Orbit (LEO) with total doses of 1.0 mGy to 30 mGy were utilized From this analysis we were able to identify distinct biological signatures associating specific ions with specific biological responses due to radiation exposure in space. For example, we discovered changes in mitochondrial function, ribosomal assembly, and immune pathways as a function of dose. We provided a summary of how the GeneLab’s rich database of omics experiments with animal models can be used to generate novel hypotheses to better understand human health risks from GCR exposures.

Afshin Beheshti↗

MAGIK Animation of Robotic Operations for Flight SpaceX-22 to ISS

The MAGIK Robotic analysis team provides kinematic feasibility assessments for the ISS and has produced an animation to evaluate Extravehicular Robotics (EVR) activities for the SpaceX (SpX)-22 flight. The animation also displays the current ISS configuration at the time of the flight. Flight SpX-22 includes a SpaceX Cargo Dragon vehicle docked to Node 2 Zenith (N2Z) International Docking Adapter (IDA) and consists of the delivery of the ISS Power Augmentation (IPA) Carrier. Robotic operations shown include the Space Station Remote Manipulator System (SSRMS) Trunk extraction of the IPA Carrier and maneuvering to the install position on the Payload ORU (Orbital Replacement Unit) Accommodation (POA). There is no disposal payload for this flight.

Alexander Radford Fryer↗

SpaceX-26 Animation - Operations from MAGIK AI-4177: SpX-26 (Launch-6)

The MAGIK Robotic analysis team provides kinematic feasibility assessments for the ISS and has produced an animation to evaluate Extravehicular Robotics (EVR) activities for the SpaceX (SpX)-26 flight. The animation also displays the current ISS configuration at the time of the flight. Flight SpX-26 includes a SpaceX Cargo Dragon vehicle docked to Node 2 Zenith (N2Z) International Docking Adapter (IDA) and consists of the delivery of the ISS Roll Out Solar Array (IROSA) mounted to an ISS Power Augmentation (IPA) Carrier. Robotic operations shown include the Space Station Remote Manipulator System (SSRMS) Trunk extraction of the IPA Carrier and maneuvering to the install position on the Payload ORU (Orbital Replacement Unit) Accommodation (POA). There is no disposal payload for this flight.

ISS↗

Magik Animation of Robotic Operations for Flight SpaceX-29 to ISS

The MAGIK Robotic analysis team provides kinematic feasibility assessments for the ISS and has produced an animation to evaluate Extravehicular Robotics (EVR) activities for the SpaceX (SpX)-29 flight. The animation also displays the current ISS configuration at the time of the flight. Flight SpX-29 includes a SpaceX Cargo Dragon vehicle docked to Node 2 Forward (N2F) International Docking Adapter (IDA) and consists of the delivery of AWE (Atmospheric Waves Experiment) and Integrated LCRD LEO User Modem Amplifier optical communications Terminal (ILLUMA-T). Robotic operations shown include the Special Purpose Dexterous Manipulator (SPDM) Trunk extraction of ILLUMA-T and maneuvering to the JEM RMS Handoff position, the SPDM Trunk extraction of AWE, maneuvering to Express Logistics Carrier (ELC) 1 Site 3 to remove Space Test Program - Houston 5 (STP-H5), and the installation of AWE to ELC-1 Site 3. There is no disposal payload for this flight.

EVR↗

MAGIK Animation of Robotic Operations for Flight SpaceX-30 to ISS

The MAGIK Robotic analysis team provides kinematic feasibility assessments for the ISS and has produced an animation to evaluate Extravehicular Robotics (EVR) activities for the SpaceX (SpX)-30 flight. Shown EVR activities are preliminary and final operations will be developed by Flight Operations Directorate (FOD) Robotics (ROBO). The animation also displays the current ISS configuration at the time of the flight. Flight SpX-30 includes a SpaceX Cargo Dragon vehicle docked to Node 2 Zenith (N2Z) International Docking Adapter (IDA) and consists of the delivery of the Pump Module (PM) Integrated Assembly (IA). Robotic operations shown include the Special Purpose Dexterous Manipulator (SPDM) based on the Space Station Remote Manipulator System (SSRMS) for Trunk extraction of the PM IA, maneuvering to the External Stowage Platform 3 (ESP-3), temporary removal of the Control Moment Gyro (CMG) from ESP-3 Site 4, install of the PM IA at ESP-3 Site 3 and re-install of the CMG to ESP-3 Site4. There is no disposal payload for this flight.

ISS↗

A Simultaneous PET and Fluorescence Optical Tomography Imaging System for Small Animals

For 3D FOT imaging, we have developed an innovative system geometry using a truncated conical mirror, thereby allowing simultaneous viewing of the entire surface of the animal by an EMCCD camera . This geometry, and the small size of the conical mirror (outside diameter 152 mm, total length of 62.5 mm) makes it feasible to insert the conical mirror inside the gantry of our existing microPET II scanner for simultaneous PET and 3D FOT imaging. The first-generation conical mirror was made of aluminum and coated with silver. The outside diameter of the conical mirror is 15.2 cm in diameter, which is 1 mm smaller than the open aperture diameter of microPET II. The axial length of the mirror is 6.25 cm with an axial field of view (FOV) of 6 cm. Shown is a side view schematic and photographs of the imaging system. A 650 laser with a collimation lens at the end of its pigtail fiber was used to excite the fluorescence dye. A bandpass filter following the laser removed light at other wavelengths. Another lens focused the beam into a small 1 mm diameter spot at the mouse surface. Two motorized mirrors scanned the laser beam across the mouse surface. A transparent plastic bed was placed in the center of the conical mirror. Bandpass filters, placed inside a filter wheel, were used to select emission wavelengths. In the front of the filter wheel, a long pass filter was used to remove excitation laser spillover into the measurements at the emission wavelengths. An EMCCD was used to collect the emission photons. Three line pattern lasers on a linear stage were used to extract mouse surface geometry were scanned axially along the mouse to extract the surface geometry. The bottom surface was assumed to be a flat plane based on the geometry of the imaging platform on which the object or animal was placed. To minimize ambient light effects on FOT imaging, the open aperture of the conical mirror and the gap between the FOT enclosure and PET gantry were covered with black cloth.

47 OTHER INSTRUMENTATION↗

Electrical signature analysis to quantify human and animal performance on fitness and therapy equipment such as a treadmill

The invention is a human and animal performance data acquisition, analysis, and diagnostic system for fitness and therapy devices having an interface box removably disposed on incoming power wiring to a fitness and therapy device, at least one current transducer removably disposed on said interface box for sensing current signals to said fitness and therapy device, and a means for analyzing, displaying, and reporting said current signals to determine human and animal performance on said device using measurable parameters.

47 OTHER INSTRUMENTATION↗

Electrical signal analysis to assess the physical condition of a human or animal

The invention is a human and animal performance data acquisition, analysis, and diagnostic system for fitness and therapy devices having an interface box removably disposed on incoming power wiring to a fitness and therapy device, at least one current transducer removably disposed on said interface box for sensing current signals to said fitness and therapy device, and a means for analyzing, displaying, and reporting said current signals to determine human and animal performance on said device using measurable parameters.

47 OTHER INSTRUMENTATION↗

Awake Animal Imaging Motion Tracking Software

The Awake Animal Motion Tracking Software code calculates the 3D movement of the head motion of a live, awake animal during a medical imaging scan. In conjunction with markers attached to the head, images acquired from multiple cameras are processed and marker locations precisely determined. Using off-line camera calibration data, the 3D positions of the markers are calculated along with a 6 degree of freedom position and orientation (pose) relative to a fixed initial position. This calculation is performed in real time at frame rates up to 30 frames per second. A time stamp with microsecond accuracy from a time base source is attached to each pose measurement.

Goddard, James↗

Signal transmitter and methods for transmitting signals from animals

Injectable transmitters are provided that can include a body with the body housing a power source and an oscillator, the injectable transmitter also including an antenna extending from the body, the body and antenna being of sufficient size to be injected through a 9 gauge needle. Radio frequency transmitters are provided that can include a body extending from a nose to a tail with the body housing a power source and RF signal generator components. The power source of the transmitter can define at least a portion of the nose of the body. The transmitters can have an antenna extending from the tail. Methods for attaching a radio frequency (RF) transmitter to an animal are provided. The methods can include providing an RF transmitter and providing an injection device having a needle of gauge of 9 or smaller; providing the RF transmitter into the injection device; and providing the RF transmitter through the 9 gauge or smaller needle and into the animal.

Deng, Z. Daniel↗

Methods for attaching transmitters to animals

Methods for attaching a radio frequency (RF) transmitter to an animal are provided. The methods can include providing an RF transmitter and providing an injection device having a needle of gauge of 9 or smaller; providing the RF transmitter into the injection device; and providing the RF transmitter through the 9 gauge or smaller needle and into the animal.

Deng, Z. Daniel↗

Methods for attaching transmitters to animals

Methods for attaching a radio frequency (RF) transmitter to an animal are provided. The methods can include providing an RF transmitter and providing an injection device having a needle of gauge of 9 or smaller; providing the RF transmitter into the injection device; and providing the RF transmitter through the 9 gauge or smaller needle and into the animal.

59 BASIC BIOLOGICAL SCIENCES↗

Twin Valve Caval Stent for Functional Replacement of Incompetent Tricuspid Valve: A Feasibility Animal Study

Objective: To evaluate feasibility of a twin valve caval stent (TVCS) for functional replacement of an incompetent tricuspid valve (TV) in an acute animal study. Methods: One swine and three sheep were used in the study. TVCS placement was tested in a swine with a normal TV. TVCS function was tested in three sheep with TV regurgitation created by papillary muscle avulsion. Cardiac angiograms and pressure measurements were used to evaluate TVCS function. Two sheep were studied after fluid overload. Results: TVCS was percutaneously placed properly at the central portions of the superior vena cava (SVC) and inferior vena cava (IVC) in the swine. Papillary muscle avulsion in three sheep caused significant tricuspid regurgitation with massive reflux into the right atrium (RA) and partial reflux into the SVC and IVC. TVCS placement eliminated reflux into the SVC and IVC. After fluid overload, there was enlargement of the right ventricle and RA and significant increase in right ventricle, RA, SVC, and IVC pressures, but no reflux into the IVC and SVC. Conclusion: The results of this feasibility study justify detailed evaluation of TVCS insertion for functional chronic replacement of incompetent TV.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mortality of atomic bomb survivors predicted from laboratory animals

Exposure, pathology and mortality data for mice, dogs and humans were examined to determine whether accurate interspecies predictions of radiation-induced mortality could be achieved. The analyses revealed that (1) days of life lost per unit dose can be estimated for a species even without information on radiation effects in that species, and (2) accurate predictions of age-specific radiation-induced mortality in beagles and the atomic bomb survivors can be obtained from a dose-response model for comparably exposed mice. These findings illustrate the value of comparative mortality analyses and the relevance of animal data to the study of human health effects.

NASA Discipline Radiation Health↗

Pulmonary venous flow determinants of left atrial pressure under different loading conditions in a chronic animal model with mitral regurgitation

BACKGROUND: The aim of our study was to quantitatively compare the changes and correlations between pulmonary venous flow variables and mean left atrial pressure (mLAP) under different loading conditions in animals with chronic mitral regurgitation (MR) and without MR. METHODS: A total of 85 hemodynamic conditions were studied in 22 sheep, 12 without MR as control (NO-MR group) and 10 with MR (MR group). We obtained pulmonary venous flow systolic velocity (Sv) and diastolic velocity (Dv), Sv and Dv time integrals, their ratios (Sv/Dv and Sv/Dv time integral), mLAP, left ventricular end-diastolic pressure, and MR stroke volume. We also measured left atrial a, x, v, and y pressures and calculated the difference between v and y pressures. RESULTS: Average MR stroke volume was 10.6 +/- 4.3 mL/beat. There were good correlations between Sv (r = -0.64 and r = -0.59, P <.01), Sv/Dv (r = -0.62 and r = -0.74, P <.01), and mLAP in the MR and NO-MR groups, respectively. Correlations were also observed between Dv time integral (r = 0.61 and r = 0.57, P <.01) and left ventricular end-diastolic pressure in the MR and NO-MR groups. In velocity variables, Sv (r = -0.79, P <.001) was the best predictor of mLAP in both groups. The sensitivity and specificity of Sv = 0 in predicting mLAP 15 mm Hg or greater were 86% and 85%, respectively. CONCLUSION: Pulmonary venous flow variables correlated well with mLAP under altered loading conditions in the MR and NO-MR groups. They may be applied clinically as substitutes for invasively acquired indexes of mLAP to assess left atrial and left ventricular functional status.

Pulmonary Veins/physiopathology↗