Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “AMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Certification of Uranium Isotope Amount Ratios in a Suite of Uranium Ore Concentrate Certified Reference Materials

Here, in this study, data from thirteen laboratories from around the world are presented for a successful certification of uranium isotope ratios in uranium ore concentrate (UOC) certified reference materials from the National Research Council Canada. Different mass spectrometric measurement principles (including SF-ICP-MS, quadruple ICP-MS, TIMS, MC-ICP-MS, SIMS and AMS) and measurement procedures were employed. In general, data from all sources exhibit good consistency with TIMS and MC-ICP-MS showing superior performance. The three candidate UOC CRMs (UCLO-1, UCHI-1 and UPER-1) have natural uranium isotope ratios with certified values of 0.5304(7) x 10 -4 , 0.5475(2) x 10 -4 and 0.5361(4) x 10 -4 for n( 234 U)/n( 238 U) and 0.007 2563(13), 0.007 2563(10) and 0.007 2542(11) for n( 235 U)/n( 238 U), respectively, with expanded uncertainty (k = 2) applicable to the last digit of the value given in the parentheses. Information values for n( 236 U)/n( 238 U) in these three CRMs, measured by AMS, are also provided: 10 x 10 -12 , 200 x 10 -12 and 22 x 10 -12 . The uncertainties of the proposed certified values of uranium isotope ratios in UOC CRMs are superior to available reference materials, and the values of n( 234 U)/n( 238 U) and n( 236 U)/n( 238 U) show significant variation among the three CRMs.

58 GEOSCIENCES↗

AMS/NRCan Joint Survey Report: Aerial Campaign

In January 2014 the U.S. Department of Energy (DOE), National Nuclear Security Administration (NNSA) Aerial Measuring System (AMS) and the Natural Resources Canada (NRCan) Nuclear Emergency Response project conducted a series of joint surveys at a number of locations in Nevada including the Nevada National Security Site (NNSS). The goal of this project was to compare the responses of the two agencies’ aerial radiation detection systems and data analysis techniques. This test included varied radioactive surface contamination levels and isotopic composition experienced at the NNSS and the differing data processing techniques utilized by the respective teams. Because both teams used the commercial aerial radiation detection systems from Radiation Solutions, Inc., the main focus of the campaign was to investigate the data acquisition techniques, data analysis, and ground-truth verification. The NRCan system consisted of four 4" × 4" × 16" NaI(Tl) scintillator crystals of which two were externally mounted in a modified commercial cargo basket certified for the Eurocopter AS350; the NNSA AMS system consisted of twelve 2" × 4" × 16" NaI(Tl) crystals in externally mounted dedicated pods. For NRCan, the joint survey provided an opportunity to characterize their system’s response to extended sources of various fission products at the NNSS. Since both systems play an important role in their respective countries’ national framework of radiological emergency response and are subject to multiple mutual cooperation agreements, it was important for each country to obtain more thorough knowledge of how they would employ these important assets and define the roles that they would each play in an actual response.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Transfer of triclocarban from mother to offspring during periods of development

It has been shown that a variety of chemicals are not removed after wastewater treatment, which results in their release back into environment and water supply. These chemicals may act as endocrine disrupting compounds (EDC), which may affect the function of the endocrine system and adversely affect progeny. Studies evaluating the effects of EDC during periods of offspring development are lacking, including quantitative measures of accumulation after exposure. These EDCs have the potential to bioaccumulate and transfer from mother to offspring during periods of development. This includes both gestational and lactational exposure; many EDCs are highly fat soluble therefore, transfer in breastmilk during lactation may be a major route of exposure to offspring. EDC exposure during periods of development has been associated with detrimental effects including changes in neurological development, behavior and reproductive abnormalities, and even obesity. However, the data for many EDCs are limited; chronic exposures, which more accurately mimic the exposure from contaminated drinking water, have not been done. These studies are needed to investigate the potential detrimental effects after exposure. Triclocarban (TCC) is an antimicrobial found in many personal care products including deodorants, antibacterial soaps and toothpaste. Given its widespread use, TCC is found as a contaminant in drinking water with concentrations ranging from pM to nM. Evidence of endocrine disruption after TCC exposure has been shown; when given to rats with 3-trifluoromethyl-4,4’-dichlorocabanilide (TFC) in their chow, their offspring showed a lower testes/body weight ratio. Other studies have shown that TCC can interact with endogenous hormones to potentially affect development of sex organs and interfere with reproduction. In this work, we are investigating the transfer of TCC from mother to offspring during periods of gestation and lactation. The transfer of TCC from mother to offspring was quantified using accelerator mass spectrometry (AMS). The exceptional sensitivity of AMS (pmol-amol) allows for quantification of very small quantities of 14 C- labeled material. In addition to its high sensitivity, the long half-life of 14 C (t 1/2 =5730yrs) allows for long term tracking of material. Taken together, these characteristics allow us to investigate the transfer of environmentally relevant concentrations of TCC from mother to offspring over long periods of time.

54 ENVIRONMENTAL SCIENCES↗

AMS/DOE Fellowship Recipients

The AMS/DOE graduate fellowships were awarded to three students entering their first year of graduate study. The funds allowed each student to take a full course load during their first of year of graduate study which helps each of them to enter the professional, scientific community at an earlier date. Each recipient is academically outstanding, received glowing references of support and demonstrated their strong desire to perform scientific research. As part of the fellowship, each of the students was invited to attend the AMS Annual Meeting where they got to participate in the AMS student conference, attend scientific sessions and visit the exhibition hall. In addition, a student awards luncheon was held where each of the recipients got to meet their sponsor and receive a certificate.

99 GENERAL AND MISCELLANEOUS↗

Rainier Mesa/Shoshone Mountain Flow and Transport Model Report Nevada National Security Site, Nevada, Revision 1

The purpose of this report is to describe and present the latest CAI analyses for the Rainier Mesa/Shoshone Mountain (RM/SM) CAU and review their role in the broader, historical context of CAI activities at RM/SM. As described in Sections 1.4 and 1.5, the current work was initiated after specific concerns arose during a previous CAI phase, which eventually prompted a revision of the FFACO process and the adoption of an alternative modeling strategy (AMS) for CAI work at RM/SM. The remainder of this report will describe the CAI modeling activities conducted through 2017 under the revised FFACO process and AMS discussed above.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Report of the Peer Review Panel for the Rainier Mesa/Shoshone Mountain Flow and Transport Model, Nevada National Security Site, Nevada, Revision 0

The stated purpose of the peer review is to determine whether the model, results, interpretations, and documentation are consistent with the requirements of the FFACO Alternative Modeling Strategy and Decision Process for closure of the CAU. The Peer Review Panel was asked to explicitly answer six questions that provide an overview to its conclusions and recommendations. These six questions and the panel’s responses are presented in the next section of this review report. The Peer Review Panel was asked to present and summarize its primary findings by answering six key peer review questions. These questions are as follows: 1.Is the implementation of the AMS technically and regulatorily sound and defensible? 2.Have conceptual models and/or alternatives for groundwater flow and radionuclide transport in the RM/SM system, permissible based upon available data and observations, been identified to support analyses of radionuclide migration away from the testing areas toward potential receptors? 3.Based on available data that include “maximum transport” and “minimum transport,” do the forecasts represent a range of plausible scenarios and address assumptions for parameters that are most sensitive for saturated zone flow and transport? 4.Can radionuclide transport forecasts be used as an aid in evaluating potential exposure pathways, as intended by the AMS? 5.Has the extent of contamination been bounded such that a regulatory decision can be made regarding CAU closure that is protective of human health and the environment? 6.Has anything that influences the protection of human health and the environment been missed?

54 ENVIRONMENTAL SCIENCES↗

Prototype Stilbene Neutron Collar II

A neutron collar using stilbene organic scintillator cells for fast neutron counting is described for the assay of fresh low enriched uranium (LEU) fuel assemblies. The prototype stilbene collar has a form factor similar to standard He-3 based collars and uses an AmLi interrogation neutron source. This report describes the simulation, using a custom LLNL developed MCNPX, of list mode neutron correlation data on various fuel assemblies. Some of these fuel assemblies have neutron absorbers (burnable Gd poisons) and partial defect s (DU, Fe, Pb pins). Calibration curves (doubles vs 235 U linear mass density) are presented for fast (with Cd lining) mode of operation. The modeling incorporates LLNL developed neutron crosstalk correction algorithms and stilbene light output detector response quench function. Pileup issues are addressed using the LLNL code GamGen / RadSrc to estimate the flux of alpha decay gammas from the fuel assemblies on the stilbene cells with and without Pb shielding. One panel of the prototype collar using 10 high-efficiency 4”x2” stilbene cells from Inrad Optics, using LLNL developed technology, has been constructed and calibrated for optimal PSD and data acquisition electronics. Several sources (AmLi, AmBe, Cf, DD, and DT) have been measured with the single panel and the measured data is consistent with the modeling. A novel part of our work was to determine the light output (LO) quench function for the Inrad 4” x 2” stilbene crystals through a LLNL-MCNPX simulation based optimized fitting of the measured LO data.

42 ENGINEERING↗

An Evaluation of a Neutron Time Correlated Interrogation Method for Measurement of Fissile Content in Research Reactor Spent Fuel Assemblies

There are many research reactors worldwide that have been, or are being converted from the use of high enrichment uranium (HEU) to low enrichment uranium (LEU, < 20% enriched). The verification of fissile content and initial enrichment of the spent fuel is needed for the effective safeguards of the fuel. The advanced experimental fuel counter (AEFC) was developed for the measurement of spent fuel rods and assemblies from research reactors for safeguards verification. This measurement system contains components for active neutron interrogation, passive neutron totals counting, neutron coincidence counting, and gross gamma-ray counting. This report presents the first application of the time correlated interrogation technique for the measurement of the 235 U content in research reactor spent fuel assemblies. The technique, called time correlated induced fission (TCIF), uses a 252 Cf neutron source to irradiate the fuel assembly, and the subsequent induced fission events in the fissile material are measured by coincidence counting. The doubles rates are enhanced by having the neutron trigger events from both the 252 Cf source and the induced fission neutrons in the same time gate in the coincidence analysis. The average neutrons per fission of the 252 Cf source is 3.76 and the induced fission neutrons for 235 U is 2.44, so the number of neutrons that are produced is higher than for random neutron interrogation. This high effective neutron number increases the multiplicity counting rates and reduces the statistical error. The background coincidence counts from the 252 Cf are reduced by the water in the sample cavity and the polyethylene surrounding the 3 He detector tubes. This method of active neutron interrogation has been applied to the measurement of spent research reactor (IRT) fuel assemblies. The advanced experimental fuel counter (AEFC) was used to compare the TCIF method with the typically used AmLi neutron interrogation source that emits neutrons that are random in time. The statistical uncertainty for the use of the random neutron source (AmLi) and the time correlated source ( 252 Cf) for spent fuel interrogations was evaluated.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

National User Resource for Biological Accelerator Mass Spectrometry (Annual Report)

The National User Resource for Biological Accelerator Mass Spectrometry (User Resource) will provide isotopic analysis (primarily radiocarbon or 14C) by accelerator mass spectrometry (AMS) for NIH- funded researchers across the United States and will be the only User Resource of its type in the United States. The User Resource will provide measurement capability and expertise to a research community that requires highly sensitive, quantitative isotope analyses. Since commissioning a new accelerator mass spectrometer in June 2014, we have measured over 4000 samples a year for collaborators and service users. The User Resource will enable us to continue to meet these research needs, as well as provide for new users whose research programs would benefit from AMS as a measurement tool.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

National User Resource for Biological Accelerator Mass Spectrometry Annual Report

The National User Resource for Biological Accelerator Mass Spectrometry (User Resource) will provide isotopic analysis (primarily radiocarbon or 14C) by accelerator mass spectrometry (AMS) for NIH-funded researchers across the United States and will be the only User Resource of its type in the United States. The User Resource will provide measurement capability and expertise to a research community that requires highly sensitive, quantitative isotope analyses. Since commissioning a new accelerator mass spectrometer in June 2014, we have measured over 4000 samples a year for collaborators and service users. The User Resource will enable us to continue to meet these research needs, as well as provide for new users whose research programs would benefit from AMS as a measurement tool.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Using Separation-Enhanced Isotope Ratio Mass Spectrometry

Stable isotope ratio measurements using IRMS have been shown by LANL to be effective for tracking co-processed biogenic carbon, with results approaching that of AMS. The lower cost of an IRMS may enable deployment to refineries improving access and analysis turnaround times (≤ 2-hours), and by extension data that can allow process optimization to maximize renewable carbon in desired refinery products. This work will apply chemical separation approaches as part of the IRMS analyses, enabling biogenic carbon tracking in fuel product streams by boiling point range, by chemical class, or even by compound. This work will show IRMS to be at a minimum as reliable and comparable to AMS, by using separations to improve sensitivity at low blend ratios and enable refinery process optimization through onsite analysis.

36 MATERIALS SCIENCE↗

Project Fringe, Testing and Validation on Metal Additive Manufacturing

Oak Ridge National Laboratory (ORNL) worked with Additive Monitoring Systems (AMS) to demonstrate the real-time inspection of additive manufacturing (AM) binder jet fusion 3D printing (BJF). Test coupons on the ExOne Innovent were printed and monitored using AMS’s Project Fringe structured light system. Anomalies were detected automatically and classified post build as recoater powder layer non-uniformities, binder powder interaction, depressions, and sub optimal print area. These anomalies were not apparent in the visual spectrum, which suggests that the structured light system has advanced the monitoring techniques state-of-the-art for BJF.

36 MATERIALS SCIENCE↗

TRACER Carbonaceous Aerosols Thrust – University of California, Davis Field Campaign Report

The broader U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s TRacking Aerosol Convection interactions ExpeRiment (TRACER) campaign aims to increase our understanding of convective cloud life cycles and aerosol-convection interactions. Our TRACER Carbonaceous Aerosols Thrust-University of California, Davis (TRACER-CAT-UCDavis) study complemented these broader aims by characterizing and quantifying the optical properties and composition of carbonaceous aerosols during part of the TRACER intensive sampling period (July 1- July 31, 2022) at the first ARM Mobile Facility (AMF1) main site (M1) in La Porte, Texas. Our measurements complemented the suite of instrumentation already provided by the AMF1, expanding the capabilities through deployment of unique, state-of-the-science instrumentation. The instrumentation included: (i) two cavity-attenuated phase shift spectroscopy single-scatter albedo (CAPS-SSA) instruments operating at 530 nm and 630 nm, and that were modified to characterize particle light absorption, extinction, and scattering at elevated humidities; (ii) the UC Davis dual-wavelength cavity ringdown-photoacoustic spectrometer (CRD-PAS), which characterizes dry particle extinction and absorption at 405 nm and 532 nm; (iii) a soot particle aerosol mass spectrometer (SP-AMS) that operated in “laser only” mode that characterized the size-dependent compositions of black carbon (BC)-containing particles; (v) a thermal denuder, to remove coatings on particles; and (vi) a scanning electrical mobility sizer (SEMS), to characterize particle mobility diameters from 10-1300 nm. Our measurements occurred alongside complementary observations made by Los Alamos National Laboratory (LANL) during the TRACER-CAT-LANL study, including a humidified CAPS-SSA instrument operating at 450 nm. Our primary scientific interest is in understanding the relationship between particle composition and light absorption, with a particular focus on the influence of water uptake. While it is known that coatings on BC can enhance absorption, the extent to which this occurs in the atmosphere and the specific role that water plays as a coating remain unclear. The TRACER-CAT-UCDavis measurements were made with near-complete coverage for the CRD-PAS, SP-AMS, and SEMS throughout the intensive period. The UC Davis humidified CAPS-SSA instruments had significant challenges with operation owing to the demanding conditions (large temperature fluctuations, high humidity), exacerbated by supply chain issues that delayed resolution of these challenges. However, the humidified CAPS-SSA instrument operated by LANL operated throughout the intensive period with near-complete coverage. The dry light extinction measurements from the CRD-PAS measurements and the LANL CAPS-SSA exhibited a good correlation, although the CAPS-SSA systematically measured greater extinction values than expected. While all instruments, with the exception of an aerodynamic particle sizer (APS), measured behind a common particulate matter (PM)2.5 μm cyclone, the greater extinction measured by the LANL CAPS-SSA compared to the CRD-PAS may have resulted from different losses of larger particles in the sampling lines from the cyclone to the instruments; the tubing length was shorter from the cyclone to the LANL CAPS-SSA, consistent with this idea. A summary of the TRACER-CAT-UCDavis measurements, along with some of the TRACER-CAT-LANL measurements, are shown in the figure below. Notably, there were periods when the contributions of presumed dust were substantial and even dominated the observed light extinction and absorption. Also, there was a clear shift in the behavior of submicron particles from before July 16, 2022 to after, with the prior period exhibiting regular episodes of new particle formation and the latter period exhibiting rapid variations in the concentrations of small particles.

54 ENVIRONMENTAL SCIENCES↗

Conceptual Design of Passive Neutron Albedo Reactivity and Active Neutron Albedo Reactivity Instruments for Various Arrangements of Pebble Bed Reactor Pebbles

MCNP6 simulations were performed to assess the anticipated capability of the Passive Neutron Albedo Reactivity technique for nuclear safeguards measurements of irradiated pebble/pebbles. Two physical setups were examined. One with a single pebble of three different burnups and one with 27 pebbles in a cube. For all cases the sensitivity to removing all the fissile material was examined. For both of the physical setups, 4 assay cases were examined: (a) singles count rates for which the only source neutrons were the inherent neutrons in the fuel, (b) singles count rates again except this time two relatively weak AmLi sources were placed above and below the top central pebble and the combined effect of both neutron source terms were examined, (c) doubles count rates for which the only source neutrons were the inherent neutrons in the fuel, and (d) doubles count rates again except this time two relatively weak AmLi sources were placed above and below the top central pebble and the combined effect of both neutron source terms were examined. Finally, a few parameters such as Cd near the 3 He tubes were perturbed to see if the results could be improved.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Second ARM Aerosol Chemical Speciation Monitor Users’ Meeting Report

The aerosol chemical speciation monitor (ACSM) was developed to adapt the technology of the aerosol mass spectrometer (AMS) to routine, long-term, standalone monitoring. The calculation of particulate mass concentration from ACSM data requires the measurement of the response of the instrument to aerosol of specific size and composition as well as assumptions about the instrument response based on laboratory measurements and field experience acquired over more than two decades of operation of AMS and a decade of operation of the ACSM. Three parameters in the concentration calculations that are particularly important are the NO3 response factor (RFNO3), relative ionization efficiency (RIE), and the collection efficiency (CE). The values of RFNO3 and RIEs are determined from calibration, however the jump calibration method previously used in calibration can result in errors in the RIE for sulfate. This has been corrected by implementing a continuous calibration method. The default collection efficiency is 0.5. This has been shown to result in mass loadings that do not agree with mass determinations from other instruments because of effects of composition on the vaporization of the particles. The previous work of investigators addressing this issue is discussed. After preliminary work on ACSM and scanning mobility particle sizer (SMPS) data from the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility Southern Great Plains (SGP) observatory collected in late 2016 and 2017 produced a parameterization of composition dependent collection efficiency very different from the results of previous studies, SMPS data were examined and we determined that there was significant mass that the instrument did not capture because the particles with diameters larger than 465 nm are not counted by this instrument. Data for the ultra-high-sensitivity aerosol spectrometer (UHSAS), SMPS, and ACSM are available for nearly all of 2019. The data from UHSAS and SMPS collected in 2019 were compared. We found that the UHSAS data has particle counts and total volumes significantly less than measured by the condensation particle counter (CPC) and SMPS. The SMPS data were extended by fitting the average volume distribution with a log normal curve and using this relationship to estimate a mass value for the SMPS over extended diameter range. The extended SMPS mass values result in a CDCE parameterization that is in better agreement with the results of other investigators, but is still different from other formulations. The working group recommends that the ACSM data be processed with a collective efficiency (CE)=1, that this be documented clearly in the metadata, and the use of the default CE of 0.5 or a formulation of composition-dependent collection efficiencies (CDCE) chosen by the user should be implemented based on the ammonium nitrate mass fraction. This is clearly necessary for the wintertime SGP ACSM data because of the high nitrate concentrations.

47 OTHER INSTRUMENTATION↗

Proteomic Signatures of Antimicrobial Resistance in Yersinia pestis and Francisella tularensis

Antimicrobial resistance (AMR) is a well-recognized, widespread, and growing issue of concern. With increasing incidence of AMR, the ability to respond quickly to infection with or exposure to an AMR pathogen is critical. Approaches that could accurately and more quickly identify whether a pathogen is AMR also are needed to more rapidly respond to existing and emerging biological threats. We examined proteins associated with paired AMR and antimicrobial susceptible (AMS) strains of Yersinia pestis and Francisella tularensis, causative agents of the diseases plague and tularemia, respectively, to identify whether potential existed to use proteins as signatures of AMR. We found that protein expression was significantly impacted by AMR status. Antimicrobial resistance-conferring proteins were expressed even in the absence of antibiotics in growth media, and the abundance of 10–20% of cellular proteins beyond those that directly confer AMR also were significantly changed in both Y. pestis and F. tularensis. Most strikingly, the abundance of proteins involved in specific metabolic pathways and biological functions was altered in all AMR strains examined, independent of species, resistance mechanism, and affected cellular antimicrobial target. We have identified features that distinguish between AMR and AMS strains, including a subset of features shared across species with different resistance mechanisms, which suggest shared biological signatures of resistance. These features could form the basis of novel approaches to identify AMR phenotypes in unknown strains.

59 BASIC BIOLOGICAL SCIENCES↗

14 C-Cobalamin Absorption from Endogenously Labeled Chicken Eggs Assessed in Humans Using Accelerator Mass Spectrometry

Traditionally, the bioavailability of vitamin B-12 (B12) from in vivo labeled foods was determined by labeling the vitamin with radiocobalt ( 57 Co, 58 Co or 60 Co). This required use of penetrating radioactivity and sometimes used higher doses of B12 than the physiological limit of B12 absorption. The aim of this study was to determine the bioavailability and absorbed B12 from chicken eggs endogenously labeled with 14 C-B12 using accelerator mass spectrometry (AMS). 14C-B12 was injected intramuscularly into hens to produce eggs enriched in vivo with the 14 C labeled vitamin. The eggs, which provided 1.4 to 2.6 μg of B12 (~1.1 kBq) per serving, were scrambled, cooked and fed to 10 human volunteers. Baseline and post-ingestion blood, urine and stool samples were collected over a one-week period and assessed for 14 C-B12 content using AMS. Bioavailability ranged from 13.2 to 57.7% (mean 30.2 ± 16.4%). Difference among subjects was explained by dose of B12, with percent bioavailability from 2.6 μg only half that from 1.4 μg. The total amount of B12 absorbed was limited to 0.5–0.8 μg (mean 0.55 ± 0.19 μg B12) and was relatively unaffected by the amount consumed. The use of 14 C-B12 offers the only currently available method for quantifying B12 absorption in humans, including food cobalamin absorption. An egg is confirmed as a good source of B12, supplying approximately 20% of the average adult daily requirement (RDA for adults = 2.4 μg/day).

60 APPLIED LIFE SCIENCES↗

MEASUREMENTS OF COSMIC-RAY PROTON AND HELIUM SPECTRA FROM THE BESS-POLAR LONG-DURATION BALLOON FLIGHTS OVER ANTARCTICA

The BESS-Polar Collaboration measured the energy spectra of cosmic-ray protons and helium during two long-duration balloon flights over Antarctica in 2004 December and 2007 December at substantially different levels of solar modulation. Proton and helium spectra probe the origin and propagation history of cosmic rays in the galaxy, and are essential to calculations of the expected spectra of cosmic-ray antiprotons, positrons, and electrons from interactions of primary cosmic-ray nuclei with the interstellar gas, and to calculations of atmospheric muons and neutrinos. We report absolute spectra at the top of the atmosphere for cosmic-ray protons in the kinetic energy range 0.2–160 GeV and helium nuclei in the range 0.15–80 GeV/nucleon. The corresponding magnetic-rigidity ranges are 0.6–160 GV for protons and 1.1–160 GV for helium. These spectra are compared to measurements from previous BESS flights and from ATIC-2, PAMELA, and AMS-02. We also report the ratio of the proton and helium fluxes from 1.1 to 160 GV and compare this to the ratios from PAMELA and AMS-02.

79 ASTRONOMY AND ASTROPHYSICS↗