Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ABLATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Investigation of the 176 Yb Interference Correction during Determination of the 176 Hf/ 177 Hf Ratio by Laser Ablation and Solution Analysis on the Neoma MC-ICP-MS

We utilized the Neoma™, a recently released MC-ICP-MS platform offered by ThermoFisher Scientific, to assess the behavior of the Lu-Yb-Hf system during laser ablation analyses of various zircon standards as well as solution-based analyses of the JMC-475 Hf standard doped with varying quantities of Yb and Lu. The primary goal of this work was to characterize the behavior of the Yb interference correction on the Neoma™ platform since this is one of the biggest issues in the Hf isotope analysis community and because the Neoma™ platform will supplant the Neptune™ series instrument. During laser ablation analysis, we found that the overall data quality scales proportionally with the total Hf signal intensity, with higher signal analyses producing extremely accurate (within 1 ε Hf unit) and precise (sub ε Hf unit within-run standard errors) data. At low Yb signals (<0.1 V 173 Yb), we were not able to produce an accurate internal Yb mass bias factor. However, utilizing an empirical approach allows for the application of session-specific relationships between the Yb and Hf mass bias factors, determined by analysis of standards of varying Yb content, to produce accurate ε Hf values from zircons with higher Yb/Hf ratios even where the total Hf signal intensity is relatively low. Similar behavior was observed in the solution analyses. Lastly, while the behavior of the Yb interference correction on the Neoma™ platform appears comparable to the Neptune™ series MC-ICP-MS, further work will help refine the understanding of the controls on mass bias behavior, oxide formation, session-to-session stability, etc.

36 MATERIALS SCIENCE↗

Ablation of ATJ Graphite at High Temperatures

Results of an extensive experimental program on the ablation of ATJ graphite in air at surface pressures of 0.3 to 4.4 atm and surface temperatures of 2570 to 4030 K are presented. The measured mass-loss rates are correlated with surface temperature, pressure, and effective nose radius. The results are compared with several equilibrium thermochemical ablation theories which differ basically in the chemical species that are considered and in the thermodynamic properties assigned to these species. All the theories predict about the same mass-loss rate in the diffusion-controlled oxidation regime and are in good agreement with the experimental results. At higher temperatures, however, the experimental and theoretical results do not agree. At temperatures above 3700 K, the experimental mass-loss rate becomes independent of pressure and an exponential function of temperature. A comparison of the high-temperature results with the theories indicates that all the theories, except the one based on the thermodynamic properties from the JANAF tables, are invalid because they overpredict the mass-loss rate. On the other hand, the theory based on the JANAF properties underpredicts the measured mass-loss rate by a factor of three at 4000 K. At least a portion of this difference between experiment and theory is attributed to particulate mass loss which is visually observed.

Thermochemical ablation↗

A New Ablative Heat Shield Sensor Suite Project

A new sensor suite is developed to measure performance of ablative thermal protection systems used in planetary entry vehicles for robotic and human exploration. The new sensor suite measures ablation of the thermal protection system under extreme heating encountered during planetary entry. The sensor technology is compatible with a variety of thermal protection materials, and is applicable over a wide range of entry conditions.

Thermal Protection↗

3D Multifunctional Ablative Thermal Protection System

NASA is developing the Orion spacecraft to carry astronauts farther into the solar system than ever before, with human exploration of Mars as its ultimate goal. One of the technologies required to enable this advanced, Apollo-shaped capsule is a 3-dimensional quartz fiber composite for the vehicle's compression pad. During its mission, the compression pad serves first as a structural component and later as an ablative heat shield, partially consumed on Earth re-entry. This presentation will summarize the development of a new 3D quartz cyanate ester composite material, 3-Dimensional Multifunctional Ablative Thermal Protection System (3D-MAT), designed to meet the mission requirements for the Orion compression pad. Manufacturing development, aerothermal (arc-jet) testing, structural performance, and the overall status of material development for the 2018 EM-1 flight test will be discussed.

Composite↗

Conformal Ablative Thermal Protection Systems (CA-TPS) for Venus and Saturn Backshells

This poster provides an overview of the work performed to date on the Conformal Ablative TPS (CA-TPS) element of the TPSM project out of GCDP. Under this element, NASA is developing improved ablative TPS materials based on flexible felt for reinforcement rather than rigid reinforcements. By replacing the reinforcements with felt, the resulting materials have much higher strain-to-failure and are much lower in thermal conductivity than their rigid counterparts. These characteristics should allow for larger tile sizes, direct bonding to aeroshells and even lower weight TPS. The conformal phenolic impregnated carbon felt (C-PICA) is a candidate for backshell TPS for both Venus and Saturn entry vehicles.

Saturn↗

Verification of a Finite Element Model for Pyrolyzing Ablative Materials

Ablating thermal protection system (TPS) materials have been used in many reentering spacecraft and in other applications such as rocket nozzle linings, fire protection materials, and as countermeasures for directed energy weapons. The introduction of the finite element model to the analysis of ablation has arguably resulted in improved computational capabilities due the flexibility and extended applicability of the method, especially to complex geometries. Commercial finite element codes often provide enhanced capability compared to custom, specially written programs based on versatility, usability, pre- and post-processing, grid generation, total life-cycle costs, and speed.

ablating materials↗

Ablative Thermal Protection Systems Fundamentals

This is a presentation of the fundamentals of ablative TPS materials for a short course at TFAWS 2017. It gives an overall description of what an ablator is, the equations that define it, and how to model it.

TPS↗

Analysis of Fibrous Felts for Flexible Ablators Using Synchrotron Hard X-Ray Micro-Tomography

We analyzed the material properties of low-density felts that are used as substrates for new-generation flexible and conformal carbon/phenolic ablators, and compared them with those of a rigid carbon fiber preform that is used to manufacture rigid carbon/phenolic ablators. Micro-tomography measurements were obtained using synchrotron X-rays, allowing the characterization of the materials microstructure at the scale of the fibers. Using the tomography voxels as computational grids, we computed tortuosity and room temperature conductivity. In addition we performed micro-scale simulations of the oxidation of carbon fibers using a random walk model for oxygen diffusion and a probability law to model surface reactions.

Ablation↗

Development of Lyocell Based Phenolic Impregnated Carbon Ablators (PICA-D) for Future NASA Missions

Phenolic Impregnated Carbon Ablator (PICA) is a low-density ablator that has been used as the planetary entry heatshield for several NASA missions since 1999. Due to the obsolescence of the input fiber source, new PICA materials were developed using Lyocell, a domestic rayon fiber source. Results are presented from this effort. Manufacturing included fiber conversion, fabrication of tile component and near net shaped heatshield preforms, and conversion to PICA materials. Thermal, mechanical, and representative environment arc-jet testing have been conducted. Initial testing indicates comparable performance with respect to heritage PICA material, and likely "drop-in" replacement for future NASA mission needs.

Thermal Protection↗

Response of Ablative Thermal Protection Materials to Degradation in Low Earth Orbit –Characterization of Specimens from MISSE-13

The environment of low Earth orbit presents unique material interactions due to the presence of atomic oxygen and solar spectrum UV. A variety of degradation mechanisms can occur depending, inlarge part, on the specific material system involved. This talk will review the characterization of two ablative materials, PICA-D and HEEET, as well as relevant adhesive joints and coatings. PICA-D is a variant of the phenolic impregnated carbon ablator (PICA) and is the baseline thermal protection system (TPS) on Dragonfly and the lander for Mars Sample Return (MSR). HEEET is a 3D woven system from which MSR’s Earth entry TPS is derived. The samples for these materials were flown in orbit during the Materials International Space Station Experiment-13 (MISSE-13) which launched on March 6, 2020 and returned to Earth on January 13, 2021. Changes to surface microstructure and reflectivity will be presented along with tomographic analysis. The effect of differential erosion rates on the composites and the impacts of the orbit environment on coating performances will be discussed in the context of TPS performance and mission design aspects.

MISSE↗

Response of Ablative Thermal Protection Materials to Degradation in Low Earth Orbit – Characterization of Specimens from MISSE-13

The environment of low Earth orbit presents unique material interactions due to the presence of atomic oxygen and solar spectrum UV. A variety of degradation mechanisms can occur depending, in large part, on the specific material system involved. This talk will review the characterization of two ablative materials, PICA-D and HEEET, as well as relevant adhesive joints and coatings. PICA-D is a variant of the phenolic impregnated carbon ablator (PICA) and is the baseline thermal protection system (TPS) on Dragonfly and the lander for Mars Sample Return (MSR). HEEET is a 3D woven system from which MSR’s Earth entry TPS is derived. The samples for these materials were flown in orbit during the Materials International Space Station Experiment-13 (MISSE-13) which launched on March 6, 2020 and returned to Earth on January 13, 2021. Changes to surface microstructure and reflectivity will be presented along with tomographic analysis. The effect of differential erosion rates on the composites and the impacts of the orbit environment on coating performances will be discussed in the context of TPS performance and mission design aspects.

MISSE↗

Study of Graphite Ablation at Arc-Jet Conditions using Finite-Rate and Equilibrium Chemistry Models

Moving at hypersonic speeds through the atmosphere generates immense amount of heat that triggers thermo-chemical non-equilibrium effects in the flow approaching the vehicle and leads to surface chemical reactions that cause ablation and consume the material mass. This complex behavior and interaction of the aerothermal environment with a graphite surface is com- putationally modeled in the present work using a fully-coupled simulation between flow solver CHAMPS NBS-Cart and material response solver KATS-MR. In this study, we account for the thermo-chemical non-equilibrium effects occurring in the flow and use an 11-species air-carbon re- action model to simulate the ablation of the material. The reactions at the surface such oxidation, nitridation and recombination are modeled with a newly developed air-carbon reaction model. The coupled simulation is applied to study two experimental cases performed at IHF arc-jet facility at NASA Ames research center. The obtained results are compared against the measured data of surface recession, as well as surface and in-depth temperatures. Additionally, uncoupled sim- ulations, performed with equilibrium chemistry at the wall, point out the substantial differences between the coupled and uncoupled solutions, leading to higher deviation of the predicted temper- atures. Overall, we show excellent agreement between the coupled simulation predictions and the experimental data in all measured quantities.

EDL↗

Simulations of Coupled Shoulder Ablation of A Conceptual Aeroshell

The current study explores coupled numerical simulations of flow dynamics and material response affect ablation of the shoulder region of an entry capsule used in space missions like the Mars Sample Return (MSR) project. A new computational tool named Ares, developed at NASA Ames Research Center, is applied to carry out the coupled simulations by interconnecting well-established US3D (flow solver) and Icarus (material response solver), and the material considered is three-dimensional mid-density carbon phenolic (3MDCP). Particularly, this work extends the uncoupled analysis of Shrestha et al. 2022 by incorporating the coupling mechanism across the ablating surface between fluid and the capsule geometry. For simplicity, an axisymmetric geometry of the entry system is considered. A few mission-relevant parametric studies such as angles of orientation of the material layers with respect to the streamwise direction, backshell boundary conditions, and alternation of convective heat-transfer coefficients are investigated to essentially explore Ares capability with the primary focus on shoulder location.

Coupled Ablation Modeling↗

Development of Advanced Ablative Carbon Phenolic TPS for Future NASA Missions and Commercial Space

Phenolic Impregnated Carbon Ablator (PICA) is a low-density carbon phenolic ablator that has been used as the planetary entry heatshield for several NASA missions since the late 90’s. Its low density and efficient performance characteristics have proven effective for use from Discovery to Flagship class missions, from Sample Return missions such as Stardust, OSIRIS-REx to large Mars lander missions such as MSL and Mars 2020. Continued development of a mass efficient, compliant version of PICA that use a carbon felt as the substrate will be presented. The felt based versions of PICA known as Conformal PICA (C-PICA) is comparable in terms of peak heat-flux capabilities compared to standard PICA. Additionally, a novel all felt PICA-Flex offers further reductions in density, with higher thermal protection efficiency resulting in additional mass savings beyond C-PICA. Furthermore, the compliant nature of these materials allows for application without Strain Isolation Pad to a wide variety of substrates, making attractive for commercial low earth orbit missions as well as NASA’s aerocapture missions to Ice Giants. NASA is currently working with several commercial partners (Varda and Inversion Space) to Technology Transfer C/S-PICA variants for commercial LEO missions. Preliminary thermal and mechanical tests have been conducted comparing the performance of Conformal and Soft-PICA and PICA-Flex materials.

Flexible Ablative TPS↗

Hollow fiber mid-ID spectrometer with UV laser ablation sampling for fine spatial reoslution of isotope ratios in solids

We describe a system that combines isotope ratio analysis via mid-infrared (Mid-IR) laser absorption spectroscopy with fine spatial resolution sampling using a UV pulsed laser. The UV laser ablates a pit in a solid on the order of 10 microns in diameter. The sample-derived particulates resulting from laser ablation pass through a micro-combustor, and the resulting gas is analyzed using Mid-IR laser absorption spectroscopy in a capillary absorption spectrometer (CAS). The CAS uses a hollow fiber optic waveguide with a reflective inner coating and a small internal volume on the order of 1ml. The hollow fiber both guides the laser light from source to detector and contains the gas sample at reduced pressure. Near unity overlap between the laser beam and sample enables sensitive analysis with ultra-small sample size. A prototype system has been demonstrated to enable stable carbon isotopic analysis (d13C) with 1 per mil precision using <1 picomole of carbon and is currently being used to study nutrient exchange in soil/root/microbial rhizosphere studies. The smaller sample size of this system is enabling fine spatial resolution analysis (on the order of 10 microns), which is roughly an order of magnitude smaller than was possible with an isotope ratio mass spectrometer (IRMS). In addition to rhizosphere studies, the system can provide a useful tool for fine scale isotope analysis with applications in biological, forensic, and environmental science.

capillary absorption spectroscopy, laser ablation,↗

Modelling and Experimental Validation of Improved Performance of Lithium-Ion Batteries Having Thick Electrodes with Laser-Ablated Micro-Structures

For widespread adoption of electric vehicles, lithium-ion batteries (LiBs) need to achieve energy densities of >275 Wh/kg, cost less than $100/Wh, and charge to more than 80% capacity within 15 minutes. Increasing the battery electrode thicknesses is one way to increase cell energy densities while also saving on cell manufacturing cost by increasing the ratio of electrode active material to inactive material within each cell. However, increased electrode loading is often accompanied by decreased Li+-ion diffusion across the full thick electrodes. This leads to significant cell polarization that prevents full capacity utilization and accelerates cell degradation, especially at fast charging/discharging rates. The introduction of secondary pore networks in thick battery electrodes alleviates some of the trade-offs between energy and power performance. These microstructures provide low tortuosity pathways for facile Li+-ion diffusion deep into the thick electrodes, diminishing detrimental concentration gradients within the cell. Ultrafast-pulsed laser ablation is a promising method to introduce micro pores or channels in thick battery electrodes as it allows for precise control of pattern geometries, results in minimal damage to the electrode and can be introduced into existing roll-to-roll electrode manufacturing lines. Herein, the limitations of thick planer electrodes and the advanced predictive models to identify optimal electrode patterns for improved cycling performance will be presented. The impact of electrode laser patterning to create secondary pore networks also will be discussed. Materials characterization techniques (SEM-EDS, XRD) were used to explore the affect ultrafast laser ablation had on the electrode materials’ morphology and structure. The improvements in the patterned electrodes’ electrochemical cycling performances and degrees of wetting will be compared to a pristine baseline case. Finally, the discrepancies between experimentally obtained data and model predictions will be explained.

DIRECT ENERGY CONVERSION,ENERGY STORAGE↗

Absolute quantitation of propranolol from 200-μm regions of mouse brain and liver thin tissues using laser ablation-dropletProbe-mass spectrometry

Rationale: The ability to quantify drugs and metabolites in tissue with sub-mm resolution is a challenging but much needed capability in pharmaceutical research. To fill this void, a novel surface sampling approach combining laser ablation with the commercial dropletProbe automated liquid surface sampling system (LA-dropletProbe) was developed and presented here.Methods: Parylene C-coated 200 × 200 μm tissue regions of mouse brain and kidney thin tissue sections were analyzed for propranolol by laser ablation of tissue directly into a preformed liquid junction. Propranolol was detected by high performance liquid chromatography with positive ion mode electrospray ionization tandem mass spectrometry. Quantitation was achieved via application of a stable isotope-labeled internal standard and an external calibration curve.Results: Absolute concentration of propranolol determined from 200 × 200 µm tissue regions were compared to propranolol concentrations obtained from 2.3-mm-diameter tissue punches of adjacent, non-coated sections using standard bulk tissue extraction protocols followed by regular HPLC-MS/MS analysis. Average concentration of propranolol in both organs determined by the two employed methods agreed within ±12%. Furthermore, the relative abundance of phase II hydroxypropranolol glucuronide metabolites were recorded and found to be consistent with previous results.Conclusions: This work illustrates that depositing a thin parylene C layer onto thin tissue prior to analysis, which seals the surface and prevents direct liquid extraction of the drug from the tissue, coupled to the novel LA-dropletProbe surface sampling system is a viable approach for sub-mm resolution quantitative drug distribution analysis.

59 BASIC BIOLOGICAL SCIENCES↗