Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “'Interferometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Observation of Saturation of Fidelity Decay with an Atom Interferometer

We use an atom interferometer to investigate the dynamics of matter waves in a periodically pulsed optical standing wave: an atom optics realization of the quantum kicked rotor that exhibits chaotic classical dynamics. We experimentally show that a measure of the coherence between the interferometer diffraction orders can revive after a quick initial loss, and can approach a finite asymptote as the number of kicks increases. This observation demonstrates that quantum fidelity of a classically chaotic system can survive strong perturbations over long times without decay.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Noise-Immune Conjugate Large-Area Atom Interferometers

We present a pair of simultaneous conjugate Ramsey-Borde atom interferometers using large (20(Planck constant/2pi)k)-momentum transfer beam splitters, where (Planck constant/2pi)k is the photon momentum. Simultaneous operation allows for common-mode rejection of vibrational noise. This allows us to surpass the enclosed space-time area of previous interferometers with a splitting of 20(Planck constant/2pi)k by a factor of 2500. Using a splitting of 10(Planck constant/2pi)k, we demonstrate a 3.4 ppb resolution in the measurement of the fine structure constant. Examples for applications in tests of fundamental laws of physics are given.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Lattice Interferometer for Laser-Cooled Atoms

We demonstrate an atom interferometer in which atoms are laser cooled into a 1D optical lattice, suddenly released, and later subjected to a pulsed optical lattice. For short pulses, a simple analytical theory predicts the signal. We investigate both short and longer pulses where the analytical theory fails. Longer pulses yield higher precision and larger signals, and we observe a coherent signal at times that can differ significantly from the expected echo time. The interferometer has potential for precision measurements of (Planck constant/2pi)/m{sub A}, and can probe the dynamics of atoms in an optical lattice.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Enhancing the Area of a Raman Atom Interferometer Using a Versatile Double-Diffraction Technique

In this Letter, we demonstrate a new scheme for Raman transitions which realize a symmetric momentum-space splitting of 4(Planck constant/2pi)k, deflecting the atomic wave packets into the same internal state. Combining the advantages of Raman and Bragg diffraction, we achieve a three pulse state labeled an interferometer, intrinsically insensitive to the main systematics and applicable to all kinds of atomic sources. This splitting scheme can be extended to 4N(Planck constant/2pi)k momentum transfer by a multipulse sequence and is implemented on a 8(Planck constant/2pi)k interferometer. We demonstrate the area enhancement by measuring inertial forces.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Two-Dimensional X-Ray Grating Interferometer

We report on the design and experimental realization of a 2D x-ray grating interferometer. We describe how this interferometer has been practically implemented, discuss its performance, and present multidirectional scattering (dark-field) maps and quantitative phase images that have been retrieved using this device.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration of the Modulation Transfer Function of Surface Profilometers with Binary Pseudorandom Test Standards: Expanding the Application Range to Fizeau Interferometers and Electron Microscopes

A modulation transfer function (MTF) calibration method based on binary pseudorandom (BPR) gratings and arrays has been proven to be an effective MTF calibration method for interferometric microscopes and a scatterometer. Here we report on a further expansion of the application range of the method. We describe the MTF calibration of a 6 in. phase shifting Fizeau interferometer. Beyond providing a direct measurement of the interferometer's MTF, tests with a BPR array surface have revealed an asymmetry in the instrument's data processing algorithm that fundamentally limits its bandwidth. Moreover, the tests have illustrated the effects of the instrument's detrending and filtering procedures on power spectral density measurements. The details of the development of a BPR test sample suitable for calibration of scanning and transmission electron microscopes are also presented. Such a test sample is realized as a multilayer structure with the layer thicknesses of two materials corresponding to the BPR sequence. The investigations confirm the universal character of the method that makes it applicable to a large variety of metrology instrumentation with spatial wavelength bandwidths from a few nanometers to hundreds of millimeters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High energy x-ray phase contrast CT using glancing-angle grating interferometers

Purpose: The authors present initial progress toward a clinically compatible x-ray phase contrast CT system, using glancing-angle x-ray grating interferometry to provide high contrast soft tissue images at estimated by computer simulation dose levels comparable to conventional absorption based CT. Methods: DPC-CT scans of a joint phantom and of soft tissues were performed in order to answer several important questions from a clinical setup point of view. A comparison between high and low fringe visibility systems is presented. The standard phase stepping method was compared with sliding window interlaced scanning. Using estimated dose values obtained with a Monte-Carlo code the authors studied the dependence of the phase image contrast on exposure time and dose. Results: Using a glancing angle interferometer at high x-ray energy (∼45 keV mean value) in combination with a conventional x-ray tube the authors achieved fringe visibility values of nearly 50%, never reported before. High fringe visibility is shown to be an indispensable parameter for a potential clinical scanner. Sliding window interlaced scanning proved to have higher SNRs and CNRs in a region of interest and to also be a crucial part of a low dose CT system. DPC-CT images of a soft tissue phantom at exposures in the range typical for absorption based CT of musculoskeletal extremities were obtained. Assuming a human knee as the CT target, good soft tissue phase contrast could be obtained at an estimated absorbed dose level around 8 mGy, similar to conventional CT. Conclusions: DPC-CT with glancing-angle interferometers provides improved soft tissue contrast over absorption CT even at clinically compatible dose levels (estimated by a Monte-Carlo computer simulation). Further steps in image processing, data reconstruction, and spectral matching could make the technique fully clinically compatible. Nevertheless, due to its increased scan time and complexity the technique should be thought of not as replacing, but as complimentary to conventional CT, to be used in specific applications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of spatial coherence from an extended source in successive rotational shearing interferometers for achromatic stellar coronagraphy

We propose a new scheme of an achromatic nulling interferometer-coronagraph to gain a higher contrast in the star-planet model. Two successive rotational shearing interferometers improve the interference contrast limited by insufficient spatial coherence of a physically extended source, a star. The theory and simulations have been confirmed by an experiment. The theoretical value of the coronagraphic contrast has been improved from 10{sup 4} to 10{sup 10} for an angular size of the extended source of 10{sup -2}{lambda}/D, where {lambda} is the wave-length and D is the telescope's aperture diameter.

79 ASTRONOMY AND ASTROPHYSICS↗

Two-color terahertz interferometer based on the frequency-splitted orthogonal polarization modes of the water vapor laser and designed for measuring the electron density profile in the L-2M stellarator

An upgraded diagnostics for measuring the electron density profile in the L-2M stellarator is proposed. The existing diagnostics employs an interferometer based on an HCN laser with a mechanical frequency shifter and unmagnetized InSb detectors cooled with liquid helium. It is proposed to replace the HCN laser with a water vapor laser operating simultaneously at two wavelengths (220 and 118 {mu}m). Being equipped with an anisotropic exit mirror, the water vapor laser allows the generation of orthogonally polarized, frequency-splitted modes at each of these wavelengths with a frequency difference of several tens of kilohertzs. Such a scheme makes it possible to get rid of the mechanical frequency shifter. Moreover, simultaneous measurements at two wavelengths allow one to reliably separate the phase increments introduced by the plasma electron component and by variations in the lengths of the interferometer arms. To take full advantage of this scheme, specially developed cryogenic receivers consisting of Ge and InSb photodetectors placed one after another will be used. To increase the response of the system near {lambda} = 220 {mu}m, the InSb detector is placed in a Almost-Equal-To 0.55-T magnetic field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement Error of Interferometers with Diffraction Reference Wave

An experimental setup and results on aberration of sources of a reference spherical wave (SRSW) based on a single-mode optical fiber with a subwavelength output aperture obtained with the aid of an optical part of recording system (OPRS) are presented. SRSW and OPRS are developed for referenceless interferometer with diffraction reference wave. Methods for minimization of the measurement error are proposed. The SRSW and OPRS provide subnanometer measurement accuracy for optics. An increase in the measurement accuracy of the interferometer to a picometer level is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Absolute testing of the reference surface of a Fizeau interferometer through even/odd decompositions

Absolute testing of spherical surfaces is a technological necessity because of increased accuracy requirements. In a Fizeau setup, the main part of the interferometer deviations thereby comes from the reference surface. We demonstrate the validity of an absolute testing procedure for the reference surface that has been proposed earlier. The procedure relies on the decomposition of the surface deviations into odd and even parts and could be used in partially coherent illumination. The odd deviations are obtained from a basic and a 180 deg. -rotated position of an auxiliary sphere, and the even deviations can be measured with the help of a cat's eye position in double pass using an opaque half screen in the interferometer aperture.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dual-prism interferometer for collimation testing

An air-wedge lateral-shear interferometer using two prisms is presented. With a variable shear, the interferometer is suitable for testing collimation of a wide range of beam sizes down to a few millimeters in diameter. No antireflection coatings are necessary. Collimation for a light source with short coherent length is also demonstrated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Automatic null ellipsometry with an interferometer

A new approach to automatic null ellipsometry is described in which the analyzer of a traditional polarizer compensator sample analyzer (PCSA) null ellipsometer is replaced with a heterodyne Michelson interferometer. One arm of this interferometer is modified such that it produces a fixed, linearly polarized reference beam, irrespective of the input polarization state. This beam is recombined interferometrically with the measurement beam and spatially separated into its p and s polarizations. The relative phase of the resulting temporal fringes is a linear function of the polarizer azimuthal angle P, and thus this component can be driven to its null position without iteration. Once at null, the azimuthal angle of the reflected, linearly polarized light is trivially determined from the relative amplitude of the fringes. Measurements made with this instrument on a native oxide film on a silicon wafer were in excellent agreement with those made with a traditional PCSA null ellipsometer.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement of photon indistinguishability to a quantifiable uncertainty using a Hong-Ou-Mandel interferometer

We present a method for using the Hong-Ou-Mandel (HOM) interference technique to quantify photon indistinguishability within an associated uncertainty. The method allows the relative importance of various experimental factors affecting the HOM visibility to be identified, and enables the actual indistinguishability, with an associated uncertainty, to be estimated from experimentally measured quantities. A measurement equation has been derived that accounts for the non-ideal performance of the interferometer. The origin of each term of the equation is explained, along with procedures for their experimental evaluation and uncertainty estimation. These uncertainties are combined to give an overall uncertainty for the derived photon indistinguishability. The analysis was applied to measurements from an interferometer sourced with photon pairs from a parametric downconversion process. The measured photon indistinguishably was found to be 0.954+/-0.036 by using the prescribed method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Testing a Model of Planck-Scale Quantum Geometry With Broadband Correlation of Colocated 40m Interferometers

The Holometer is designed to test for a Planck diffractive-scaling uncertainty in long-baseline position measurements due to an underlying noncommutative geometry normalized to relate Black hole entropy bounds of the Holographic principle to the now-finite number of position states. The experiment overlaps two independent 40 meter optical Michelson interferometers to detect the proposed uncertainty as a common broadband length fluctuation. 150 hours of instrument cross-correlation data are analyzed to test the prediction of a correlated noise magnitude of $7\times10^{−21}$ m/$\sqrt{\rm Hz}$ with an effective bandwidth of 750kHz. The interferometers each have a quantum-limited sensitivity of $2.5\times 10^{−18}$ m/$\sqrt{\rm Hz}$, but their correlation with a time-bandwidth product of $4\times 10^{11}$ digs between the noise floors in search for the covarying geometric jitter. The data presents an exclusion of 5 standard deviations for the tested model. This exclusion is defended through analysis of the calibration methods for the instrument as well as further sub shot noise characterization of the optical systems to limit spurious background-correlations from undermining the signal.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A New Simple Interferometer for Obtaining Quantitatively Evaluable Flow Patterns

The method described in the present report makes it possible to obtain interferometer records with the aid of any one of the available Schlieren optics by the addition of very simple expedients, which fundamentally need not to be inferior to those obtained by other methods, such as the Mach-Zehnder interferometer, for example. The method is based on the fundamental concept of the phase-contrast process developed by Zernike, but which in principle has been enlarged to such an extent that it practically represents an independent interference method for general applications. Moreover, the method offers the possibility, in case of necessity, of superposing any apparent wedge field on the density field to be gauged. The theory is explained on a purely physical basis and illustrated and proved by experimental data. A number of typical cases are cited and some quantitative results reported.

INSTRUMENTS - INTERFEROMETERS↗

Imaging interferometer using dual broadband quantum well infrared photodetectors

The Jet Propulsion Laboratory is developing a new imaging interferometer that has double the efficiency of conventional interferometers and only a fraction of the mass and volume. The project is being funded as part of the Defense Advanced Research Projects Agency (DARPA) Photonic Wavelength And Spatial Signal Processing program (PWASSSP).

IR quantum well interferometer imaging spectromete↗