Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “x-ray reflectivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Noncontacting measuring device to indicate deflection of turbopump internal rotating parts

Noncontacting, nondestructive techniques to measure vibrations and deflections of parts in future LOX and LH2 multistage turbopump prototypes are reported. The measurements include shaft vibration, vibration of turbine wheel and blades, blade clearance, vibration of impellers, value component flutter, and vibration of face seal components. Three techniques were selected for development: ultrasonic Doppler devices, flash X-ray, and light-pipe reflectance.

Hamilton, D. B.↗

Particle impact and optical property analysis of the surfaces of Surveyor 3 materials

As part of the investigation of Surveyor 3 materials, a study was conducted to determine the effect of the lunar environment on some of the painted and unpainted exterior surfaces. Examination of the camera parts and tube sections was conducted using three techniques: (1) optical and scanning electron microscopy, (2) energy dispersive X-ray probe analysis, and (3) spectral reflectance measurements.

Anderson, D. L.↗

Design of grazing-incidence X-ray telescopes. I.

The theoretical and practical constraints on designs of grazing-incidence X-ray telescopes are discussed. It is shown that there is a maximum useful diameter for an X-ray telescope. It is further shown that when practical constraints are considered, the maximum reflecting area is not necessarily achieved by utilizing the largest available area within this diameter. Equations are derived that allow rapid calculation of the effective area of an X-ray telescope before one proceeds to detailed studies utilizing Monte Carlo techniques.

Weisskopf, M. C.↗

X-Ray Polarization of Z-Type Neutron Star Low-Mass X-Ray Binaries II. Spectropolarimetric Analysis

IXPE has provided for the first time detailed energy- and time-resolved X-ray polarimetry of Z-type neutron star low-mass X-ray binaries (NS-LMXBs) as they move along their color-color diagrams (CCDs). These sources can reach the highest polarization observed for NS-LXMBs in the 2–8 keV range when they move along the horizontal branch. In a previous paper, we characterized the spectral state of a sample of Z-sources using the CCD and estimated the polarization with model-independent analysis. Here, we present detailed spectropolarimetric analysis for each source on each branch using data from IXPE, NICER, and NuSTAR. The continuum X-ray emission of all the sources is well described with a combination of thermal accretion disk emission plus a harder Comptonized component. In addition, reflection features, in particular the relativistically broadened Fe Kα line, are observed for our sources, except GX 5–1. For most of the sources and branches, the main contribution to the X-ray emission and polarization is due to Comptonization: moving from the horizontal branch (HB) to the normal branch (NB), the polarization degree (PD) in the 2–8 keV band varies from about 6% to 3–4%, while the PD is loosely constrained in the flaring branch (FB), due to the shorter exposures. These PD values are significantly higher than theoretical expectations for typical spreading or boundary layer configurations. The polarization of the disk is generally lower (below 3%) but still higher than predictions for an electron scattering-dominated, plane-parallel atmosphere above the disk observed at the corresponding inclination. Moreover, the polarization angle (PA) of the disk seems to be significantly misaligned and not perpendicular to that of Comptonization. We find no correlation between the polarization signal and the inclination, nor with the contribution of reflected photons throughout the Z-track.

accretion↗

Elastohydrodynamic film thickness formula based on X-ray measurements with a synthetic paraffinic oil

An empirical elastohydrodynamic film thickness formula for heavily loaded contacts based upon X-ray film thickness measurements made with a synthetic paraffinic oil is presented. The deduced relation was found to adequately reflect the high load dependence exhibited by the measured minimum film thickness data at high Hertizian contact stresses, that is, above 1.04 x 10 to the ninth N/sq m (150,000 psi). Comparisons were made with the numerical results from a theoretical isothermal film thickness formula. The effects of changes in contact geometry, material, and lubricant properties on the form of the empirical model are also discussed.

Loewenthal, S. H.↗

Evaluation of nondestructive testing techniques for the space shuttle nonmetallic thermal protection system

A program was conducted to evaluate nondestructive analysis techniques for the detection of defects in rigidized surface insulation (a candidate material for the Space Shuttle thermal protection system). Uncoated, coated, and coated and bonded samples with internal defects (voids, cracks, delaminations, density variations, and moisture content), coating defects (holes, cracks, thickness variations, and loss of adhesion), and bondline defects (voids and unbonds) were inspected by X-ray radiography, acoustic, microwave, high-frequency ultrasonic, beta backscatter, thermal, holographic, and visual techniques. The detectability of each type of defect was determined for each technique (when applicable). A possible relationship between microwave reflection measurements (or X-ray-radiography density measurements) and the tensile strength was established. A possible approach for in-process inspection using a combination of X-ray radiography, acoustic, microwave, and holographic techniques was recommended.

Tiede, D. A.↗

Elastohydrodynamic film thickness model for heavily loaded contacts

An empirical elastohydrodynamic (EHD) film thickness formula for predicting the minimum film thickness occurring within heavily loaded contacts (maximum Hertz stresses above 150,000 psi) was developed. The formula was based upon X-ray film thickness measurements made with synthetic paraffinic, fluorocarbon, Type II ester and polyphenyl ether fluids covering a wide range of test conditions. Comparisons were made between predictions from an isothermal EHD theory and the test data. The deduced relationship was found to adequately reflect the high-load dependence exhibited by the measured data. The effects of contact geometry, material and lubricant properties on the form of the empirical model are also discussed.

Loewenthal, S. H.↗

Elastohydrodynamic film thickness model for heavily loaded contacts

An empirical elastohydrodynamic (EHD) film thickness formula for predicting the minimum film thickness occurring within heavily loaded contacts (maximum Hertz stresses above 1.04 GN/sq m (150,000 psi)) was developed. The formula was based upon X-ray film thickness measurements made with synthetic paraffinic, fluorocarbon, Type II ester, and polyphenyl ether fluids covering a wide range of test conditions. Comparisons were made between predictions from an isothermal EHD theory and the test data. The deduced relationship was found to adequately reflect the high-load dependence exhibited by the measured data. The effects of contact geometry, material, and lubricant properties on the form of the empirical model are also discussed.

Loewenthal, S. H.↗

X-Ray Polarization From the Atoll 4U 1735−44 Suggests a Low Inclination

X-ray polarimetry is a new tool capable of probing the geometry of accretion onto weakly magnetized neutron stars. Here we present the first X-ray spectro-polarimetric results from coordinated observations of the atoll source 4U 1735−44, conducted with the Imaging X-ray Polarimetry Explorer (IXPE), NICER, and NuSTAR . Over the 2–8 keV energy range, we obtained a marginal detection of polarization with the polarization degree of 1.4% ± 0.7% and polarization angle of −29◦ ± 14◦, corresponding to a 3σ upper limit on the polarization degree of 3.5%. The best-fit model to describe the spectrum comprises a thermal component associated with the accretion disk, a Comptonized black body component, and a relativistic reflection component. From the reflection model, we infer a disk inclination of ∼40◦. The spectroscopic and polarimetric properties of 4U 1735−44 are consistent with those observed in other atoll sources studied by IXPE, with its low polarization likely due to its low inclination

X-rays: binaries↗

A versatile Mossbauer spectrometer and its applications in vibration measurement

A Fe-57 Mossbauer spectrometer, equally efficient in transmission and reflection geometries, is described. The radiation detector consists of a 1.524- by 5.08 by 5.08-cm rectangular NaI(Tl) crystal with a hole 1.524 cm in diameter. The front and back faces of the crystal are covered with beryllium windows 0.0127 cm thick and 3.81 cm in diameter. The energy of the radiation accepted for counting ranges from 6.3 keV conversion X-rays to the 14.4 keV reemitted gamma rays. The spectrometer was used to measure various types of low frequency (10 Hz) and low amplitude (0.254 mm) periodic motion of steel specimens.

Singh, J. J.↗

A focusing collector for long wavelength X-ray astronomy.

Rocket studies of the low-energy X-ray sky conducted so far suffer from serious experimental problems. Therefore, an apparatus was design ed to overcome the outstanding experimental problems. The instrument developed was successfully flown in an Aerobee-170 rocket. The new device utilizes a grazing incidence paraboloid as an energy concentrator and low-pass filter. The effective bandpass of the instrument from 100 to 280 eV is determined by the combination of the counter window transmission and the mirror reflectivity.

Yentis, D. J.↗

Imaging slitless spectrometer for X-ray astronomy

Imaging slitless spectrometer, a combination of an X ray transmission /or reflection/ grating and image-forming X ray telescope, is capable of obtaining simultaneous spatial and spectral information about celestial X ray sources.

Gursky, H.↗

Noncontacting device to indicate deflection of turbopump internal rotating parts

Phase 2 (development) which was concluded for the ultrasonic Doppler device and the light-pipe-reflectance device is reported. An ultrasonic Doppler breadboard system was assembled which accurately measured runout in the J-2 LOX pump impeller during operation. The transducer was mounted on the outside of the pump volute using a C-clamp. Vibration was measured by conducting the ultrasonic wave through the volute housing and through the fluid in the volute to the impeller surface. The impeller vibration was also measured accurately using the light-pipe probe mounted in an elastomeric-gland fitting in the pump case. A special epoxy resin developed for cryogenic applications was forced into the end of the fiber-optic probe to retain the fibers. Subsequently, the probe suffered no damage after simultaneous exposure to 2150 psi and 77 F. Preliminary flash X-radiographs were taken of the turbine wheel and the shaft-bearing-seal assembly, using a 2-megavolt X-ray unit. Reasonable resolution and contrast was obtained. A fast-neutron detector was fabricated and sensitivity was measured. The results demonstrated that the technique is feasible for integrated-time measurements requiring, perhaps, 240 revolutions to obtain sufficient exposure at 35,000 rpm. The experimental verification plans are included.

Hamilton, D. B.↗

A Bragg spectrometer for stellar X-ray astronomy.

Poor energy resolution and the steeply varying continuum spectrum make it impossible to obtain with proportional counters an unambiguous identification of certain emission features of Sco X-1. For this reason a Bragg crystal spectrometer was constructed. The instrument, flown successfully aboard an Aerobee-170 rocket, scanned the spectral range from 2.4 to 2.9 keV. The spectrometer consists of two large reflecting crystals of synthetic graphite. The results obtained during the flight of the instrument clearly indicate that the Bragg method can yield much higher sensitivity to line emission than can proportional counter methods.

Kestenbaum, H.↗