Computer program grade 2 for the design and analysis of heat-pipe wicks

This user's manual describes the revised version of the computer program GRADE(1), which designs and analyzes heat pipes with graded porosity fibrous slab wicks. The revisions are: (1) automatic calculation of the minimum condenser-end stress that will not result in an excess-liquid puddle or a liquid slug in the vapor space; (2) numerical solution of the equations describing flow in the circumferential grooves to assess the burnout criterion; (3) calculation of the contribution of excess liquid in fillets and puddles to the heat-transport; (4) calculation of the effect of partial saturation on the wick performance; and (5) calculation of the effect of vapor flow, which includes viscousinertial interactions.

Eninger, J. E.

Improved heat-pipe wick

Fabrication techniques in application with conventional heat pipe-wick technology produces high quality annular wicks with smaller pores, higher density, and greater rigidity.

Arcella, F. G.

Heat transfer during the boiling of liquids in heat pipe wicks

Data in the literature on heat transfer in the case of nucleate boiling of various liquids in the wicks of heat pipes are reviewed. It is shown that none of the known analytical relationships can be used to generalize, with sufficient accuracy, the experimental data found in the literature. It is further shown that the exponent of the specific heat flux in the heat transfer law changes as a function of the liquid and wick properties. A relationship is obtained which generalizes experimental data for heat transfer agents of moderate temperatures (water, acetone, ethanol, and R-11 and R-113 coolants) and ammonia.

Gontarev, Yu. K.

Polymeric heat pipe wick

A wick for use in a capillary loop pump heat pipe is described. The wick material is an essentially uniformly porous, permeable, open-cell, polyethylene thermoplastic foam having an ultrahigh average molecular weight of from approximately 1 to 5 million, and an average pore size of about 10 to 12 microns. A representative material having these characteristics is POREX UF, which has an average molecular weight of about 3 million. This material is fully compatible with the FREONs and anhydrous ammonia and allows for the use of these very efficient working fluids in capillary loops.

Seidenberg, Benjamin

Ceramic heat pipe wick

A wick for use in a capillary loop pump heat pipe is disclosed. The wick material is an essentially uniformly porous, permeable, open-cell, silicon dioxide/aluminum oxide inorganic ceramic foam having a silica fiber ratio, by weight, of about 78 to 22, respectively, a density of 6 lbs/cu ft, and an average pore size of less than 5 microns. A representative material having these characteristics is Lockheed Missile and Space Company, Inc.'s HTP 6-22. This material is fully compatible with the freons and anhydrous ammonia and allows for the use of these very efficient working fluids, and others, in capillary loops.

Seidenberg, Benjamin

Vaporization heat transfer of dielectric liquids on enhanced surfaces covered with screen wicks

Experiments were conducted to investigate the vaporization heat transfer characteristics for the dielectric liquid FC-72 on several wicking surfaces which may be used in flat-plate heat pipes. The wicking materials studied included microstructure enhanced surfaces and coarse surfaces covered with screen meshes. Experimental data for q versus deltaT curves and critical heat fluxes were obtained for the two different operating conditions of a heat pipe, evaporation, and shallow pool boiling. When the liquid level was above the heated surface, the height of the liquid level above the surface was varied from 0 to 10 mm. When the liquid level was below the heated surface, the distance from the liquid level to the edge of the surface was adjusted from 0 to 15 mm. Experimental results revealed that for shallow pool boiling when the heated surface was covered with a wire screen mesh, the heat transfer coefficient increased at lower heat fluxes but the critical heat flux (CHF) decreased for all the surfaces tested. In the case of evaporation, both CHF and the heat transfer coefficient increased as the microstructure surfaces were covered with screen meshes.

Gu, C. B.

Porous Foam Based Wick Structures for Loop Heat Pipes

As part of an effort to identify cost efficient fabrication techniques for Loop Heat Pipe (LHP) construction, NASA Goddard Space Flight Center's Cryogenics and Fluids Branch collaborated with the U.S. Naval Academy s Aerospace Engineering Department in Spring 2012 to investigate the viability of carbon foam as a wick material within LHPs. The carbon foam was manufactured by ERG Aerospace and machined to geometric specifications at the U.S. Naval Academy s Materials, Mechanics and Structures Machine Shop. NASA GSFC s Fractal Loop Heat Pipe (developed under SBIR contract #NAS5-02112) was used as the validation LHP platform. In a horizontal orientation, the FLHP system demonstrated a heat flux of 75 Watts per square centimeter with deionized water as the working fluid. Also, no failed start-ups occurred during the 6 week performance testing period. The success of this study validated that foam can be used as a wick structure. Furthermore, given the COTS status of foam materials this study is one more step towards development of a low cost LHP.

Silk, Eric A.

Development of a Hybrid Single/Two-Phase Capillary-Based Micro-Cooler Using Copper Inverse Opals Wick with Silicon 3D Manifold for High-Heat-Flux Cooling Application: Preprint

Previously, two-phase capillary-based cooling from narrow (200-1,000 micrometer) heater-bridge copper inverse opal (CIO) wicks with heat flux levels exceeding 1,400 watts per square cm with a low superheat of approximately 10 degrees C was demonstrated. Here, we demonstrate the area scaling of the proposed technology to large-area micro-cooler for the high-heat-flux cooling of microprocessors and power electronics. We developed a hybrid single/two-phase micro-cooler that relies on capillary wicking in 25-micrometer-thick CIOs with an open channel silicon 3D-manifold for liquid delivery and vapor extraction, to achieve a high heat flux of approximately 400 watts per square cm over a heated area of 1 square cm. For the range of inlet water (21 degrees C water temperature) flowrates from 5 to 60 mL per min, we achieved total thermal resistances and vapor qualities of 0.68-0.2 square cm Kelvin per watt and 0.55-0.12, respectively. The high heat flux levels are achieved with flowrates that are 10 times smaller than conventional single- or two-phase microchannel cooling technology. The corresponding two-phase thermal resistances are in the range of 0.05 to 0.02 square cm Kelvin per watt with temperature superheat of 8 to 6 degrees C. While the overall performance of the large-area (10 by 10 square millimeter) capillary-based micro-cooler degraded compared to previous demonstration of the technology for a heated area of 5 by 5 square millimeter, preliminary computational fluid dynamics (CFD) modeling indicates that an improved manifold design will be able to achieve comparable performance.

capillary flow

NSF-NASA Extreme Design & Wicked Problems Workshop

To learn how we might solve some important and challenging problems that require us to step into extreme or “wicked problem” domains. Where systems-level engineering and design are required to integrate with other domains. Connect with the external community to cross-pollinate on best methods, processes, and tools.

Innovation

Experimental Demonstration and Characterization of a Ceramic Sintered Wick Heat Pipe Evaporator

As electrified aircraft propulsion (EAP) matures and power electronics, electric machines, and batteries achieve higher power density, the thermal management of these devices becomes ever more critical. In this paper, a heat pipe made from a dielectric ceramic material is proposed, which enables its use in the thermal management of a high frequency filter inductor for an EAP power electronics application. The manufacturing process for the sintered powder wick was developed and its performance characterized. The heat pipe is further experimentally demonstrated via an open evaporator test and shown to behave analogous to a constant conductance heat pipe.

Thermal Management

Experimental Demonstration and Characterization of a Ceramic Sintered Wick Heat Pipe Evaporator

As electrified aircraft propulsion (EAP) matures and power electronics, electric machines, and batteries achieve higher power density, the thermal management of these devices becomes ever more critical. In this paper, a heat pipe made from a dielectric ceramic material is proposed, which enables its use in the thermal management of a high frequency filter inductor for an EAP power electronics application. The manufacturing process for the sintered powder wick was developed and its performance characterized. The heat pipe is further experimentally demonstrated via an open evaporator test and shown to behave analogous to a constant conductance heat pipe.

Thermal management

Capillary-Enhanced Two-Phase Micro-Cooler Using Copper-Inverse-Opal Wick with Silicon Microchannel Manifold for High-Heat-Flux Cooling Application

In this work, we demonstrate a two-phase capillary-fed boiling micro-cooler that consists of a ~ 25-..mu..m-thick copper inverse opal (CIO) porous wicking structure for high-heat-flux boiling and a silicon 3D-manifold for distributed liquid delivery and vapor extraction across a 0.5 cm x 0.5 cm heated area. At low inlet water mass flow rates of 1.5 to 1.9 g(min)-1, the micro-cooler displays nearly two-phase boiling with exit vapor quality ~ 1 and a high critical heat flux (CHF) of 253 to 320 W cm-2 with low superheat of ~ 10 degrees C resulting in a thermal resistance of boiling ~ 0.025 cm2 degrees C W-1 or heat transfer coefficient of 0.4 MW m-2 degrees C-1. For higher flow rates of 5, 10, and 15 g(min)-1, the micro-cooler exhibits a hybrid single-phase and two-phase cooling regime where the contribution of the sensible heat (single-phase) cooling is linearly added to that of the two-phase cooling. For the highest flow rate of 15 g(min)-1, the CHF is increased to ~ 500 W cm-2 resulting in an overall thermal resistance of ~ 0.18 cm2 degrees C W-1. However, the two-phase heat transfer effectiveness, which estimates the utilization level of the inlet mass flow rate for two-phase boiling, is reduced to ~ 0.11. To achieve the best cooling system performances, the micro-cooler must operate entirely within the two-phase boiling regime (exit vapor quality or two-phase heat transfer effectiveness ~ 1). Ideally, the "coolant" should be delivered near its saturation temperature (~ 100 degrees C for water), which provides significant advantages for the energy-efficient operation of data centers and power electronics. We present detailed analysis with Infrared and high speed camera images at various inlet flow rates and heat fluxes to understand complex heat transfer in the micro-cooler. Furthermore, a conjugate thermofluidic simulation model, which incorporates the physics of capillary-fed boiling in a porous copper layer, agrees well with the experimental data.

capillary-enhanced boiling