Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “water wire”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Analysis of Hot-Wire Probe Ice Water Content Measurements in High Ice Water Content Conditions

During the 2022 High Ice Water Content (HIWC) Flight Campaign, ice water content (IWC) measurements were made at various locations on the NASA DC-8 Airborne Science Laboratory using the Isokinetic Probe Version 2 (IKP2), Ice Crystal Detectors (ICD), and Robust Probe. Correlations of a wing mounted ICD to IKP2 were made to determine the collision/retention efficiency of the ICD total water content (TWC) element in glaciated conditions. Similarly, correlations of a nose mounted ICD near the pitot probes were made to the IKP2 and to the wing-mounted ICD to estimate the ice concentration factor near the DC-8 pitot probes. Results from the 2022 flight campaign were compared to results from the HIWC RADAR II flight campaign in 2018. There was an apparent reduction in the ICD TWC collision/retention efficiency during the 2022 flight campaign. Although reasons for this discrepancy were explored, more analyses are needed to fully understand the causes. However, it was concluded that an estimated ice concentration factor at the nose of 2.5 was consistent between the two flight campaigns. Additionally, a correlation model was developed to relate measurements from a Nose ICD to freestream IWC as measured by the IKP2 to support IWC measurements from the 2022 Convective Processes Experiment - Cabo Verde (CPEX-CV) flight campaign.

Icing↗

Analysis of Hot-Wire Probe Ice Water Content Measurements in High Ice Water Content Conditions

During the 2022 High Ice Water Content (HIWC) Flight Campaign, ice water content (IWC) measurements were made at various locations on the NASA DC-8 Airborne Science Laboratory using the Isokinetic Probe Version 2 (IKP2), Ice Crystal Detectors (ICD), and Robust Probe. Correlations of a wing mounted ICD to IKP2 were made to determine the collision/retention efficiency of the ICD total water content (TWC) element in glaciated conditions. Similarly, correlations of a nose mounted ICD near the pitot probes were made to the IKP2 and to the wing-mounted ICD to estimate the ice concentration factor near the DC-8 pitot probes. Results from the 2022 flight campaign were compared to results from the HIWC RADAR II flight campaign in 2018. There was an apparent reduction in the ICD TWC collision/retention efficiency during the 2022 flight campaign. Although reasons for this discrepancy were explored, more analyses are needed to fully understand the causes. However, it was concluded that an estimated ice concentration factor at the nose of 2.5 was consistent between the two flight campaigns. Additionally, a correlation model was developed to relate measurements from a Nose ICD to freestream IWC as measured by the IKP2 to support IWC measurements from the 2022 Convective Processes Experiment - Cabo Verde (CPEX-CV) flight campaign.

Icing↗

Boiling from small cylinders.

Heat transfer is observed as a function of temperature on small horizontal wires in water and four organic liquids. When the wire radius is sufficiently small, the hydrodynamic transitions in the boiling curve disappear and the curve becomes monotonic. Three modes of heat removal are identified for the monotonic curve and described analytically: a natural convection mode, a mixed film boiling and natural convection mode, and a pure film boiling mode. Nucleate boiling does not occur on the small wires. The study was motivated by an interest in predicting the behavior of large heaters at low gravity. The application of the present results to such circumstances is therefore discussed. It is proposed that the peak and minimum heat fluxes will vanish at low gravity as well as on small wires.

Bakhru, N.↗

Tidal energy resource characterization measurements at Cook Inlet’s East Foreland: Velocity and turbulence

To characterize tidal current and turbulence at a top tidal energy site off the East Foreland in Cook Inlet, Alaska, United States, three moorings were deployed for two months between July and August 2021, and a transect survey was conducted over the course of two tidal cycles at the end of the deployment period. Measurements of velocity and turbulence were then analyzed to better understand the site's hydrodynamics and power potential. Analysis reveals that swift, north-flowing flood currents peak at 4~m/s, while south-flowing ebb currents reach just over 3~m/s. Turbulence intensity ranges from 23\% at the seafloor to 8\% near the surface, and the presence of the foreland creates more intense turbulence near-shore during ebb tide than flood. Power availability at the site could be as high as 720~MW, or 13~kW/m$^2$, though the energy available to a marine energy device will be smaller than this estimate because of water-to-wire efficiency and wake losses. The results from this measurement campaign will inform the validation of a high-resolution tidal hydrodynamic model, as well as early tidal energy projects that are beginning to move beyond the prototyping and demonstration stages to full-scale deployments.

McVey, James R.↗

Computer Simulation Studies of Ion Channel Gating: Characteristics of the M2 Channel of Influenza-A Virus in a Phospholipid Bilayer

The 25 amino acids long, transmembrane fragment of the Influenza virus M2 protein forms a homotetrameric channel that transports protons across lipid bilayers. It has been postulated that high efficiency and selectivity of this process is due to gating by four histidine residues that occlude the channel lumen in the closed state. Two mechanisms of gating have been postulated. In one mechanism, the proton is "shuttled" through the gate by attaching to the delta nitrogen atom on the extracellular side of the imidazole ring, followed by the release of the proton attached to the epsilon nitrogen atom on the opposite side. In the second mechanism, the four histidines move away from each other due to electrostatic repulsion upon protonation, thus opening the gate sufficiently that a wire of water molecules can penetrate the gate. Then, protons are transported by "hopping" along the wire. In this paper, both mechanisms are evaluated in a series of molecular dynamics simulations by investigating stability of different protonation states of the channel that are involved in these mechanisms. For the shuttle mechanism, these are states with all epsilon protonated histidines, one biprotonated residue or one histidine protonated in the delta position. For the gate opening mechanism, this is the state in which all four histidines are biprotonated. In addition, a state with two biprotonated histidines is considered. For each system, composed of the protein channel embedded in phospholipid bilayer located between two water lamellae, a molecular dynamics trajectory of approximately 1.3 ns (after equilibration) was obtained. It is found that the states involved in the shuttle mechanism are stable during the simulations. Furthermore, the orientations and dynamics of water molecules near the gate are conducive to proton transfers involved in the shuttle. In contract, the fully biprotonated state, implicated in the gate opening mechanism, is not stable and the channel looses its structural integrity. If only two histidines are biprotonated the channel deforms but remains intact with the gate mostly closed. In summary, the results of this study lend support to the shuttle mechanism but not to the gate opening mechanism of proton gating in M2.

Schweighofer, Karl J.↗

Simultaneous Ice Water Content Measurements at Multiple Locations on the NASA DC-8 Aircraft during the 2018 HIWC RADAR Flight Campaign

Ice water content measurements were made simultaneously at three locations on the NASA DC-8 in natural, glaciated conditions during the 2018 High Ice Water Content RADAR flight campaign. The purpose of these measurements was to further evaluate efficiency factors of hot-wire total water content probes in glaciated conditions and investigate the enhancement of ice crystal concentrations near fuselage surfaces due to flow field inertial effects, and ice crystals impacting the nose, breaking up, and flowing downstream. The total water content measurements were made using either Science Engineering Associates Ice Crystal Detectors or Robust Probes. Three common sensors were mounted on an underwing canister considered to be in near free-flow conditions, a standoff from a fuselage window, and the nose of the fuselage near the pitot probes. The Ice Crystal Detector total water content sensor and Robust Probe sensor collection and retention efficiencies were evaluated through comparisons with the underwing Ice Crystal Detector and Robust Probe measurements to the IKP2 isokinetic evaporator probe, which provided the reference ice water content measurement. Local ice water content at the nose position was evaluated by comparing ratios of the nose and underwing ice crystal detectors to the IKP2. Local ice water content at the window-standoff location was also evaluated by comparing total water content sensor measurements from the window ice crystal detector to the measurements made with the underwing and nose Ice Crystal Detectors The key findings were: 1) the Ice Crystal Detector total water content sensor ice water content efficiency factor was similar to previous estimates, but reduced with increased ice crystal median mass diameter; 2) the ice water content at the fuselage nose location near the DC-8 pitot probes was approximately 2.5 times the freestream values – although this estimate is affected by a higher probe efficiency factor due to smaller particles in the debris cloud from impacts upstream of the probe; and 3) the ice water content at the 17” standoff from the port window varied from about 50% to 3 times freestream values in a complicated manner. Similar measurement locations are not uncommon on cloud research aircraft, where ice particle measurements may be subject to similar uncertainties.

Aircraft Icing↗

Simultaneous Ice Water Content Measurements at Multiple Locations on the NASA DC-8 Aircraft during the 2018 HIWC RADAR Flight Campaign

Ice water content measurements were made simultaneously at three locations on the NASA DC-8 in natural, glaciated conditions during the 2018 High Ice Water Content RADAR flight campaign. The purpose of these measurements was to further evaluate efficiency factors of hot-wire total water content probes in glaciated conditions and investigate the enhancement of ice crystal concentrations near fuselage surfaces due to flow field inertial effects, and ice crystals impacting the nose, breaking up, and flowing downstream. The total water content measurements were made using either Science Engineering Associates Ice Crystal Detectors or Robust Probes. Three common sensors were mounted on an underwing canister considered to be in near free-flow conditions, a standoff from a fuselage window, and the nose of the fuselage near the pitot probes. The Ice Crystal Detector total water content sensor and Robust Probe sensor collection and retention efficiencies were evaluated through comparisons with the underwing Ice Crystal Detector and Robust Probe measurements to the IKP2 isokinetic evaporator probe, which provided the reference ice water content measurement. Local ice water content at the nose position was evaluated by comparing ratios of the nose and underwing ice crystal detectors to the IKP2. Local ice water content at the window-standoff location was also evaluated by comparing total water content sensor measurements from the window ice crystal detector to the measurements made with the underwing and nose Ice Crystal Detectors The key findings were: 1) the Ice Crystal Detector total water content sensor ice water content efficiency factor was similar to previous estimates, but reduced with increased ice crystal median mass diameter; 2) the ice water content at the fuselage nose location near the DC-8 pitot probes was approximately 2.5 times the freestream values – although this estimate is affected by a higher probe efficiency factor due to smaller particles in the debris cloud from impacts upstream of the probe; and 3) the ice water content at the 17” standoff from the port window varied from about 50% to 3 times freestream values in a complicated manner. Similar measurement locations are not uncommon on cloud research aircraft, where ice particle measurements may be subject to similar uncertainties.

o Aircraft Icing↗

Simultaneous Ice Water Content Measurements at Multiple Locations on the NASA DC-8 Aircraft during the 2018 HIWC RADAR Flight Campaign

Ice water content measurements were made simultaneously at three locations on the NASA DC-8 in natural, glaciated conditions during the 2018 High Ice Water Content RADAR flight campaign. The purpose of these measurements was to further evaluate efficiency factors of hot-wire total water content probes in glaciated conditions and investigate the enhancement of ice crystal concentrations near fuselage surfaces due to flow field inertial effects, and ice crystals impacting the nose, breaking up, and flowing downstream. The total water content measurements were made using either Science Engineering Associates Ice Crystal Detectors or Robust Probes. Three common sensors were mounted on an underwing canister considered to be in near free-flow conditions, a standoff from a fuselage window, and the nose of the fuselage near the pitot probes. The Ice Crystal Detector concave total water content sensor and Robust Probe sensor collection and retention efficiencies were evaluated through comparisons with the underwing Ice Crystal Detector and Robust Probe measurements to the Isokinetic Probe version 2 (IKP2), which provided the reference ice water content measurement. Local ice water content at the nose position was evaluated by comparing ratios of the nose and underwing ice crystal detectors to the IKP2. Local ice water content at the window-standoff location was also evaluated by comparing total water content sensor measurements from the window probes to the measurements made with the underwing and nose probes. The key findings were: (1) the Ice Crystal Detector concave water content sensor efficiency factor to glaciated conditions was similar to previous estimates, but reduced with increased ice crystal median mass diameter; (2) the ice water content at the fuselage nose location near the DC-8 pitot probes was approximately 2.5 times the freestream values—although this estimate is affected by a higher probe efficiency factor due to smaller particles in the debris cloud from impacts upstream of the probe; and (3) the ice water content at the 17 in. standoff from the port window varied from about 50 percent to nearly three times freestream values in a complicated manner. Similar measurement locations are not uncommon on cloud research aircraft, where ice particle measurements may be subject to similar uncertainties.

Aircraft Icing↗

Lessons learned from the design and operation of a small-scale cross-flow tidal turbine

In 2023, a first-generation prototype of a small-scale marine current turbine was operated in Sequim Bay, Washington (USA) for 141 days. The system, referred to as the Turbine Lander, was the product of a laboratory-to-field effort to develop a system that enables enhanced ocean sensing or vehicle recharge in remote, energetic settings. The turbine consists of a vertical-axis, cantilevered rotor (1.19 m x 0.85 m) with four foils installed on a gravity foundation. A broader range of constraints including the deployment strategy, site characteristics, and estimated loads, drove the system’s design. This work presents the design, characterization, operation, and post-recovery engineering assessment of the Turbine Lander. Pre-deployment characterization efforts yielded a peak power coefficient of approximately 0.3 for the rotor, although system losses resulted in much lower water-to-wire efficiencies under most operating conditions. The results demonstrate the importance of co-design among key components of the powertrain and control systems to achieve acceptable system efficiency across operating conditions.

Co-design↗

Icing Sensor Probe

Aircraft icing is a serious safety problem for the general aviation and some commuter transport airplanes. There has been tremendous growth in the commuter aviation industry in the last few years, Since these type of aircraft generally operate at lower altitudes they consequently spend a far greater proportion of their time operating in icing conditions. For the past thirty years airborne and ground based facilities have relied primarily on two types of cloud physics instrumentation to measure the characteristics of icing clouds: hot wire liquid water content probes and laser based particle sizing probes for the measurement of water droplet size. The instrumentation is severely limited by the technology that was developed during the 1970's and is quite large in size. The goal of this research is to develop one instrument with a wide bandwidth, better response time, higher resolution, user selectability, and small and lightweight. NASA Glenn Research Center, Droplet Measurement Technology, and Meteorology Society of Canada have developed a collaborative effort to develop such an instrument. This paper describes the development and test results of the prototype Icing Sensor Probe.

Emery, Edward↗

Ice Particle Impact on Cloud Water Content Instrumentation

Determining the total amount of water contained in an icing cloud necessitates the measurement of both the liquid droplets and ice particles. One commonly accepted method for measuring cloud water content utilizes a hot wire sensing element, which is maintained at a constant temperature. In this approach, the cloud water content is equated with the power required to keep the sense element at a constant temperature. This method inherently assumes that impinging cloud particles remain on the sensing element surface long enough to be evaporated. In the case of ice particles, this assumption requires that the particles do not bounce off the surface after impact. Recent tests aimed at characterizing ice particle impact on a thermally heated wing section, have raised questions about the validity of this assumption. Ice particles were observed to bounce off the heated wing section a very high percentage of the time. This result could have implications for Total Water Content sensors which are designed to capture ice particles, and thus do not account for bouncing or breakup of ice particles. Based on these results, a test was conducted to investigate ice particle impact on the sensing elements of the following hot-wire cloud water content probes: (1) Nevzorov Total Water Content (TWC)/Liquid Water Content (LWC) probe, (2) Science Engineering Associates TWC probe, and (3) Particle Measuring Systems King probe. Close-up video imaging was used to study ice particle impact on the sensing element of each probe. The measured water content from each probe was also determined for each cloud condition. This paper will present results from this investigation and attempt to evaluate the significance of ice particle impact on hot-wire cloud water content measurements.

Emery, Edward F.↗

Properties of cirrus generating cells.

Particle size spectra were measured during 20 hr of sampling in cirrus generating cells (uncinus, stratus, spissatus, thunderstorm anvil) and the particle concentration, mean crystal length, ice water content, reflectivity factor, and precipitation rate were calculated from these spectra. Average values of the physical properties in the generating cells were obtained. Growth was found to be downward, reaching a maximum ice water content just below the base of the generating cell. The maximum ice water contents (not including the thunderstorm anvil) were found in cirrus uncinus. Liquid water was not found throughout the cirrus sampling by measurement with the Johnson-Williams hot-wire liquid-water meter; however, it is believed that liquid water is present as a transient phase.

Heymsfield, A. J.↗

Miniature Instrumentation for SIPR (Subsurface Ice PRobe)

Ice coring has proved to be a valuable scientific tool for determining climate history on Earth. The goal of the SIPR project is to develop a simple extraterrestrial ice sampling method of comparable value to coring. The SIPR probe works by melting its way through glacial ice, pumping the melt water to the surface for analysis as it descends hundreds of meters. The specific geometry of the probe, along with size and power constraints, requires creative diagnostic instrumentation. A thin, vertically strung heated filament will provide continuous-level monitoring of water in down-hole containers. The filament has an appreciable temperature coefficient to resistance (TCR), so as water cools the wire, its resistance decreases. At a constant electrical current, the voltage across the filament varies linearly with water level.

Ostmo, Karl P.↗

Multi frame radiography of supersonic water jets interacting with a foil target

Pulsed-power-driven underwater electrical explosion of cylindrical or conical wire arrays produces supersonic water jets that emerge from a bath, propagating through the air above it. Interaction of these jets with solid targets may represent a new platform for attaining materials at high pressure (>1010 Pa) conditions in a university-scale laboratory. However, measurements of the internal structure of such jets and how they interact with targets are difficult optically due to large densities and density contrasts involved. We utilized multi-frame x-ray radiographic imaging capabilities of the ID19 beamline at the European Synchrotron Radiation Facility to explore the water jet and its interaction with a 50 μm thick copper foil placed a few mm from the surface of water. The jet was generated with a ∼130 kA-amplitude current pulse of ∼450 ns rise time applied to a conical wire array. X-ray imaging revealed a droplet-type structure of the jet with an average density of <400 kg/m3 propagating with a velocity of ∼1400 m/s. Measurements of deformation and subsequent perforation of the target by the jet suggested pressures at the jet–target interface of ∼5 × 109 Pa. The results were compared to hydrodynamic simulations for better understanding of the jet parameters and their interaction with the foil target. These results can be used in future research to optimize the platform, and extend it to larger jet velocities in the case of higher driving currents supplied to the wire array.

Physics↗

The Harp probe - An in situ Bragg scattering sensor

A wave sensor, consisting of parallel, evenly spaced capacitance wires, whose output is the sum of the water surface deflections at the wires, has been built and tested in a wave tank. The probe output simulates Bragg scattering of electromagnetic waves from a water surface with waves; it can be used to simulate electromagnetic probing of the sea surface by radar. The study establishes that the wave probe, called the 'Harp' for short, will simulate Bragg scattering and that it can also be used to study nonlinear wave processes.

Mollo-Christensen, E.↗

Variation of the drag coefficient and its dependence on sea state

Using a Gill propeller vane anemometer and resistance wave wires over a water column depth of 15 m, simultaneous measurements of the momentum flux and sea surface wave spectra were acquired from the Pisa mast, 28 km offshore in the German Bight during autumn and winter 1979. These data were analyzed to identify the relationship between wind stress and surface waves. It was found that wind stresses for wind speeds above 15 m/s were regularly higher than open ocean wind stresses as reported by Smith (1980) and by Large and Pond (1981) for the same mean wind speed. These results, when described in terms of the drag coefficient, compared closely with the results of Sheppard et al. (1972), who collected surface layer statistics over Lough Neagh, Northern Ireland. After modeling the surface waves of the North Sea as a function of wave saturation (or wave age), it became evident that variations in the magnitude of the drag coefficient could be explained by coincident variations in the surface wave energy spectrum. By applying the wave dependent roughness length model described by Kitaigorodskii (1973), the North Sea drag coefficient was predicted to be larger than drag coefficients reported from the open sea.

Geernaert, G. L.↗