Engineering PapersSearch

SEARCH · Engineering Papers

Results for “water system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Expedited desalination permitting enables adaptive planning and water system cost reduction

Seawater desalination is a drought-proof water supply for coastal cities, but widespread development of desalination plants in the U.S. has been limited by both cost and the complexity of permitting processes designed to minimize environmental impact . This work estimates the value of accelerating the permitting timeline without changing environmental or social standards. On average, faster permitting reduces the frequency of desalination plant construction and operation, the overall costs of robust water system operation, the environmental impacts of drought-tolerant water supplies due to shorter duration of plant operation. Expedited permitting allows fundamental changes in how water infrastructure is deployed, facilitating a transition from anticipatory construction and continuous operation of seawater desalination capacity as a redundant drought buffer to just-in-time (i.e. adaptive) deployment of seawater desalination capacity when critical drought thresholds are crossed. We demonstrate the value of expedited desalination permitting in enabling adaptive planning and reducing water system costs using a simple case study in Santa Barbara, CA. We discuss additional forms of adaptive water infrastructure planning as enabled by faster permitting and address their challenges and opportunities. Lastly, we identify synergies between innovation in adaptive planning, innovation in expedited permitting practices, and innovation in water technology.

adaptive planning

Sensor assemblies and methods for emulating interaction of entities within water systems

Methods for emulating interaction of entities within water systems are provided. The methods can include introducing a sensor assembly into a water system. The sensor assembly can include: a circuit board supporting processing circuitry components on either or both of opposing component support surfaces of the circuit board; a housing about the circuit board and the components, the housing being circular about the circuit board in at least one cross section; and wherein the support surfaces of the circuit board are substantially parallel with the plane of the housing in the one cross section.

Deng, Z. Daniel

Overview of Potable Water Systems on Spacecraft Vehicles and Applications for the Crew Exploration Vehicle (CEV)

Providing water necessary to maintain life support has been accomplished in spacecraft vehicles for over forty years. This paper will investigate how previous U.S. space vehicles provided potable water. The water source for the spacecraft, biocide used to preserve the water on-orbit, water stowage methodology, materials, pumping mechanisms, on-orbit water requirements, and water temperature requirements will be discussed. Where available, the hardware used to provide the water and the general function of that hardware will also be detailed. The Crew Exploration Vehicle (CEV or Orion) water systems will be generically discussed to provide a glimpse of how similar they are to water systems in previous vehicles. Conclusions on strategies that could be used for CEV based on previous spacecraft water systems will be made in the form of questions and recommendations.

Peterson, Laurie J.

Preliminary design package for solar heating and hot water system

Two prototype solar heating and hot water systems for use in single-family dwellings or commercial buildings were designed. Subsystems included are: collector, storage, transport, hot water, auxiliary energy, and government-furnished site data acquisition. The systems are designed for Yosemite, California, and Pueblo, Colorado. The necessary information to evaluate the preliminary design for these solar heating and hot water systems is presented. Included are a proposed instrumentation plan, a training program, hazard analysis, preliminary design drawings, and other information about the design of the system.

Source record

Design package for solar domestic hot water system

The initial design of a solar domestic hot water system is considered. The system performance specification and detailed design drawings are included. The hot water systems consist of the following subsystems: collector, storage, control, transport, auxiliary energy, and government-furnished site data acquisition. The two systems are installed at Tempe, Arizona, and San Diego, California.

Source record

Hot Water, Cold Reality: Feasibility Assessment of Iodine Removal in Heated Spacecraft Potable Water Systems

The current eXploration Potable Water Dispenser (xPWD) design removes iodine upstream of the heated leg due to concerns with the Activated Carbon and Ion Exchange (ACTEX) functionality in hot water, leaving the downstream volume without residual biocide. The NESC determined that this non-iodinated volume is a concern for microbial growth during exploration missions and proposed 33 biocide architecture options for future missions that could address this concern. The top-ranked architecture out of the report was Option 1: moving the iodine removal media as close to the dispensing needle as possible to minimize the wetted components without biocide in the xPWD. Three main challenges were identified with this proposed configuration. First, the hot water at 175 ± 25 °F is a concern for the potential physical degradation of the ion exchange resin and lowered adsorption capacity in activated carbon. Second, moving the ACTEX or alternative sorption media closer to the dispense needle increases the unheated volume downstream of the heater, challenging the ability for dispensed water to meet temperature requirements. Finally, bubbles evolved from dissolved gas coming out of solution in the heater could clog or reduce the efficiency of the sorption media. To address the first challenge, more thermally robust ion exchange resins were identified and adsorption capacity tests were planned and will be discussed in a companion ICES paper (ICES-2026-5). To address the dispense temperature concerns, allowable bed size and architectural configuration changes are proposed. The value of adding phase separators to remove bubbles and potential implementation schemes are discussed. These findings support the development of potable water systems resilient to microbial risks during long-duration space missions.

Biocide

Hot Water, Cold Reality: Feasibility Assessment of Iodine Removal in Heated Spacecraft Potable Water Systems

The current eXploration Potable Water Dispenser (xPWD) design removes iodine upstream of the heated leg due to concerns with the Activated Carbon and Ion Exchange (ACTEX) functionality in hot water, leaving the downstream volume without residual biocide. The NESC determined that this non-iodinated volume is a concern for microbial growth during exploration missions and proposed 33 biocide architecture options for future missions that could address this concern. The top-ranked architecture out of the report was Option 1: moving the iodine removal media as close to the dispensing needle as possible to minimize the wetted components without biocide in the xPWD. Three main challenges were identified with this proposed configuration. First, the hot water at 175 ± 25 °F is a concern for the potential physical degradation of the ion exchange resin and lowered adsorption capacity in activated carbon. Second, moving the ACTEX or alternative sorption media closer to the dispense needle increases the unheated volume downstream of the heater, challenging the ability for dispensed water to meet temperature requirements. Finally, bubbles evolved from dissolved gas coming out of solution in the heater could clog or reduce the efficiency of the sorption media. To address the first challenge, more thermally robust ion exchange resins were identified and adsorption capacity tests were planned and will be discussed in a companion ICES paper (ICES-2026-5). To address the dispense temperature concerns, allowable bed size and architectural configuration changes are proposed. The value of adding phase separators to remove bubbles and potential implementation schemes are discussed. These findings support the development of potable water systems resilient to microbial risks during long-duration space missions.

PWD

Crew Exploration Vehicle (CEV) Potable Water System Verification Description

The Crew Exploration Vehicle (CEV), also known as Orion, will ferry a crew of up to six astronauts to the International Space Station (ISS), or a crew of up to four astronauts to the moon. The first launch of CEV is scheduled for approximately 2014. A stored water system on the CEV will supply the crew with potable water for various purposes: drinking and food rehydration, hygiene, medical needs, sublimation, and various contingency situations. The current baseline biocide for the stored water system is ionic silver, similar in composition to the biocide used to maintain quality of the water transferred from the Orbiter to the ISS and stored in Contingency Water Containers (CWCs). In the CEV water system, the ionic silver biocide is expected to be depleted from solution due to ionic silver plating onto the surfaces of the materials within the CEV water system, thus negating its effectiveness as a biocide. Since the biocide depletion is expected to occur within a short amount of time after loading the water into the CEV water tanks at the Kennedy Space Center (KSC), an additional microbial

Peterson, Laurie

Material Compatibility Study of Coated Metals to Maintain Biocidal Silver in a Spacecraft Potable Water System

Ionic silver-based biocide is an option of strong interest for future exploration and has been baselined for several emerging spacecraft potable water systems. A challenge for the use of silver biocide remains the depletion of ionic silver on wetted materials of construction. Consequently, the design and/or selection of materials that can be used as the wetted system components need specific consideration. As part of the strategy to address this issue, a multitiered approach is being investigated that looks at combinations of conventional and non-conventional spacecraft treatment processes and materials. In this study, eleven chemically-resistant polymer coatings were applied as surface treatments onto coupons that were cut out from three types of conventional spacecraft-grade metals (Titanium Grade 2, Inconel 718, and 316L Stainless Steel). The coated metals were immersed in a static 400 parts per billion silver biocide solution at a surface-area-to-volume ratio of 2.0 cm^-1 and left to soak for predefined periods of time. The concentration of the solution in contact with the coated samples were then analyzed via inductively coupled plasma mass spectrometry, and the data used to determine the extent to which the coatings provided a barrier to silver loss. This paper summarizes the coating selection process, the configuration of the test, and the performance of each coating-metal combination as a mitigation to silver depletion. The preliminary results demonstrate that select coatings are proving effective at maintaining biocidal silver concentrations. The knowledge acquired through this investigation will be used to assess the feasibility of using these coatings as a robust strategy for maintaining biocidal silver in the water systems. Future studies are planned to assess the specific use of these coatings and to better understand the implications of utilizing this material approach in the future spacecraft potable water system designs.

coatings

Material Compatibility Study of Coated Metals to Maintain Biocidal Silver in a Spacecraft Potable Water System

Ionic silver-based biocide is an option of strong interest for future exploration and has been baselined for several emerging spacecraft potable water systems. A challenge for the use of silver biocide remains the depletion of ionic silver on wetted materials of construction. Consequently, the design and/or selection of materials that can be used as the wetted system components need specific consideration. As part of the strategy to address this issue, a multitiered approach is being investigated that looks at combinations of conventional and non-conventional spacecraft treatment processes and materials. In this study, eleven chemically-resistant polymer coatings were applied as surface treatments onto coupons that were cut out from three types of conventional spacecraft-grade metals (Titanium Grade 2, Inconel 718, and 316L Stainless Steel). The coated metals were immersed in a static 400 parts per billion silver biocide solution at a surface-area-to-volume ratio of 2.0 cm^-1 and left to soak for predefined periods of time. The concentration of the solution in contact with the coated samples were then analyzed via inductively coupled plasma mass spectrometry, and the data used to determine the extent to which the coatings provided a barrier to silver loss. This paper summarizes the coating selection process, the configuration of the test, and the performance of each coating-metal combination as a mitigation to silver depletion. The preliminary results demonstrate that select coatings are proving effective at maintaining biocidal silver concentrations. The knowledge acquired through this investigation will be used to assess the feasibility of using these coatings as a robust strategy for maintaining biocidal silver in the water systems. Future studies are planned to assess the specific use of these coatings and to better understand the implications of utilizing this material approach in the future spacecraft potable water system designs.

coatings

Biofilm formation and control in a simulated spacecraft water system - Three year results

Two simulated spacecraft water systems are being used to evaluate the effectiveness of iodine for controlling microbial contamination within such systems. An iodine concentration of about 2.0 mg/L is maintained in one system by passing ultrapure water through an iodinated ion exchange resin. Stainless steel coupons with electropolished and mechanically-polished sides are being used to monitor biofilm formation. Results after three years of operation show a single episode of significant bacterial growth in the iodinated system when the iodine level dropped to 1.9 mg/L. This growth was apparently controlled by replacing the iodinated ion exchange resin, thereby increasing the iodine level. The second batch of resin has remained effective in controlling microbial growth down to an iodine level of 1.0 mg/L. SEM indicates that the iodine has impeded but may have not completely eliminated the formation of biofilm. Metals analyses reveal some corrosion in the iodinated system after 3 years of continuous exposure. Significant microbial contamination has been present continuously in a parallel noniodinated system since the third week of operation.

Schultz, John R.

Machine Learning–Based Condition Monitoring of a Circulating Water System of a Canadian Nuclear Plant

With the need to maintain long-term reliable energy using nuclear power plants, there is an underlying demand to ensure that the maintenance of plant components and systems is also done in an efficient and cost-effective manner. One way to achieve this is by moving from time-based maintenance to condition-based maintenance. The research presented in this paper focuses on applying statistical and machine-learning-based methods to capture anomalies within data for fault detection to further develop into condition monitoring. This paper focuses on system data for a circulating water system (CWS) of a pressurized heavy-water reactor for detecting anomalies. The different methodologies used for detecting and capturing anomalies in the CWS data are matrix profile, density-based spatial clustering of applications with noise (DBSCAN), and support vector machines (SVMs). Matrix profile and DBSCAN are used to distinguish between normal data and anomalous data. This paper presents a hybrid method using DBSCAN and SVM when a portion of the data is used for DBSCAN to generate clusters. This portion of data is then used to train the SVM along with the clusters generated by DBSCAN as output. SVM is then tested on unseen data as a predictive tool, which can work in real time to categorize data points as either normal or anomalous. This paper presents results that show the high accuracies of DBSCAN and SVM in capturing anomalies within the data for a CWS for fault detection. Thus, the maintenance plan would be focused on component condition rather than a time-based schedule by switching to an automated system to identify and predict faults within a CWS.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS

Disinfection of Spacecraft Potable Water Systems by Passivation with Ionic Silver

Microbial growth is common on wetted surfaces in spacecraft environmental control and life support systems despite the use of chemical and physical disinfection methods. Advanced control technologies are needed to limit microorganisms and increase the reliability of life support systems required for long-duration human missions. Silver ions and compounds are widely used as antimicrobial agents for medical applications and continue to be used as a residual biocide in some spacecraft water systems. The National Aeronautics and Space Administration (NASA) has identified silver fluoride for use in the potable water system on the next generation spacecraft. Due to ionic interactions between silver fluoride in solution and wetted metallic surfaces, ionic silver is rapidly depleted from solution and loses its antimicrobial efficacy over time. This report describes research to prolong the antimicrobial efficacy of ionic silver by maintaining its solubility. Three types of metal coupons (lnconel 718, Stainless Steel 316, and Titanium 6AI-4V) used in spacecraft potable water systems were exposed to either a continuous flow of water amended with 0.4 mg/L ionic silver fluoride or to a static, pre-treatment passivation in 50 mg/L ionic silver fluoride with or without a surface oxidation pre-treatment. Coupons were then challenged in a high-shear, CDC bioreactor (BioSurface Technologies) by exposure to six bacteria previously isolated from spacecraft potable water systems. Continuous exposure to 0.4 mg/L ionic silver over the course of 24 hours during the flow phase resulted in a >7-log reduction. The residual effect of a 24-hour passivation treatment in 50 mg/L of ionic silver resulted in a >3-log reduction, whereas a two-week treatment resulted in a >4-log reduction. Results indicate that 0.4 mg/L ionic silver is an effective biocide against many bacteria and that a prepassivation of metal surfaces with silver can provide additional microbial control.

Birmele, Michele N.

To Biocide or not to Biocide? Exploring the "No Biocide" Option in Spacecraft Potable Water Systems

Residual biocide has been used to protect against microbial growth in spacecraft potable water systems since the Gemini program. Iodine, the biocide currently used on the International Space Station (ISS) has a long history of use but presents a few challenges for exploration: it must be removed using a consumable absorbent before crew consumption and is known to lose its biocidal concentration due to interactions with wetted components, especially during periods of dormancy. Biocidal silver is being considered for exploration missions as it is safe for crew consumption, but it too has challenges with proper material design to maintain sufficient disinfection residuals. An idea proposed by some in the Environmental Control and Life Support System (ECLSS) community has been that the biocide does not provide a true barrier against microbial growth, and therefore, perhaps the challenges of maintaining a residual biocide in the system could be best overcome by removing the biocide altogether. In this argument, they point to the regenerative water treatment system on the ISS which produces high purity water that theoretically meets the microbiological requirements before the iodine is added. Exploration water processing systems are expected to have similar water processing capabilities. This paper will discuss the role that residual biocide may play in controlling microbial growth and presents perspectives on the potential risks associated with removing it from exploration water systems.

biocide

To Biocide or not to Biocide? Exploring the "No Biocide" Option in Spacecraft Potable Water Systems

Residual biocide has been used to protect against microbial growth in spacecraft potable water systems since the Gemini program. Iodine, the biocide currently used on the International Space Station (ISS) has a long history of use but presents a few challenges for exploration: it must be removed using a consumable absorbent before crew consumption and is known to lose its biocidal concentration due to interactions with wetted components, especially during periods of dormancy. Biocidal silver is being considered for exploration missions as it is safe for crew consumption, but it too has challenges with proper material design to maintain sufficient disinfection residuals. An idea proposed by some in the Environmental Control and Life Support System (ECLSS) community has been that the biocide does not provide a true barrier against microbial growth, and therefore, perhaps the challenges of maintaining a residual biocide in the system could be best overcome by removing the biocide altogether. In this argument, they point to the regenerative water treatment system on the ISS which produces high purity water that theoretically meets the microbiological requirements before the iodine is added. Exploration water processing systems are expected to have similar water processing capabilities. This paper will discuss the role that residual biocide may play in controlling microbial growth and presents perspectives on the potential risks associated with removing it from exploration water systems.

biocide

To Biocide or Not to Biocide? Exploring the "No Biocide" Option in Spacecraft Potable Water Systems

Residual biocide has been used to protect against microbial growth in spacecraft potable water systems since the Gemini program. Iodine, the biocide currently used on the International Space Station (ISS) has a long history of use but presents a few challenges for exploration: it must be removed using a consumable absorbent before crew consumption and is known to lose its biocidal concentration due to interactions with wetted components, especially during periods of dormancy. Biocidal silver is being considered for exploration missions as it is safe for crew consumption, but it too has challenges with proper material design to maintain sufficient disinfection residuals. An idea proposed by some in the Environmental Control and Life Support System (ECLSS) community has been that the biocide does not provide a true barrier against microbial growth, and therefore, perhaps the challenges of maintaining a residual biocide in the system could be best overcome by removing the biocide altogether. In this argument, they point to the regenerative water treatment system on the ISS which produces high purity water that theoretically meets the microbiological requirements before the iodine is added. Exploration water processing systems are expected to have similar water processing capabilities. This paper will discuss the role that residual biocide may play in controlling microbial growth and presents perspectives on the potential risks associated with removing it from exploration water systems.

biocide

To Biocide or Not to Biocide? Exploring the "No Biocide" Option in Spacecraft Potable Water Systems

Residual biocide has been used to protect against microbial growth in spacecraft potable water systems since the Gemini program. Iodine, the biocide currently used on the International Space Station (ISS) has a long history of use but presents a few challenges for exploration: it must be removed using a consumable absorbent before crew consumption and is known to lose its biocidal concentration due to interactions with wetted components, especially during periods of dormancy. Biocidal silver is being considered for exploration missions as it is safe for crew consumption, but it too has challenges with proper material design to maintain sufficient disinfection residuals. An idea proposed by some in the Environmental Control and Life Support System (ECLSS) community has been that the biocide does not provide a true barrier against microbial growth, and therefore, perhaps the challenges of maintaining a residual biocide in the system could be best overcome by removing the biocide altogether. In this argument, they point to the regenerative water treatment system on the ISS which produces high purity water that theoretically meets the microbiological requirements before the iodine is added. Exploration water processing systems are expected to have similar water processing capabilities. This paper will discuss the role that residual biocide may play in controlling microbial growth and presents perspectives on the potential risks associated with removing it from exploration water systems.

biocide