Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “water segmentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

International Space Station USOS Potable Water Dispenser Development

The International Space Station (ISS) Russian Segment currently provides potable water dispensing capability for crewmember food and beverage rehydration. All ISS crewmembers rehydrate Russian and U.S. style food packages from this location. A new United States On-orbit Segment (USOS) Potable Water Dispenser (PWD) is under development. This unit will provide additional potable water dispensing capability to support an onorbit crew of six. The PWD is designed to provide incremental quantities of hot and ambient temperature potable water to U.S. style food packages. It will receive iodinated water from the Fuel Cell Water Bus in the U.S. Laboratory element. The unit will provide potable-quality water, including active removal of biocidal iodine prior to dispensing. A heater assembly contained within the unit will be able to supply up to 2.0 liters of hot water (65 to 93oC) every thirty minutes. This quantity will allow three to four crewmembers to rehydrate their food and beverages from this location during a single meal. The unit is designed to remain functional for up to ten years with replacement of limited life items such as filters. It will be the size of two stacked Shuttle Middeck lockers (approximately the size of two small suitcases) and integrated into a science payload rack in the U.S. Laboratory element. Providing potable-quality water at the proper temperature for food and beverage reconstitution is critical to maintaining crew health and well-being. The numerous engineering challenges as well as human factors and safety considerations during the concept, design, and prototyping are outlined in this paper.

Shaw, Laura A.↗

Daytime Water Detection Based on Color Variation

Robust water detection is a critical perception requirement for unmanned ground vehicle (UGV) autonomous navigation. This is particularly true in wide open areas where water can collect in naturally occurring terrain depressions during periods of heavy precipitation and form large water bodies (such as ponds). At far range, reflections of the sky provide a strong cue for water. But at close range, the color coming out of a water body dominates sky reflections and the water cue from sky reflections is of marginal use. We model this behavior by using water body intensity data from multiple frames of RGB imagery to estimate the total reflection coefficient contribution from surface reflections and the combination of all other factors. Then we describe an algorithm that uses one of the color cameras in a forward- looking, UGV-mounted stereo-vision perception system to detect water bodies in wide open areas. This detector exploits the knowledge that the change in saturation-to-brightness ratio across a water body from the leading to trailing edge is uniform and distinct from other terrain types. In test sequences approaching a pond under clear, overcast, and cloudy sky conditions, the true positive and false negative water detection rates were (95.76%, 96.71%, 98.77%) and (0.45%, 0.60%, 0.62%), respectively. This software has been integrated on an experimental unmanned vehicle and field tested at Ft. Indiantown Gap, PA.

reflection coefficient↗

Overview of the International Space Station’s Water and Cabin Air Quality: A Five-Year Status

Since the beginning of the International Space Station (ISS), water and air quality have been monitored to ensure crew health and verify the performance of the regenerative Environmental Control and Life Support (ECLS) systems. Over the last 25 years, the ISS has evolved greatly with significant changes to operations, crew complement sizes, visiting vehicles, payloads, and upgrades within the regenerative hardware, seen through Technology Demonstration integrations. In particular, better assessment and prevention of volatile organic releases from payloads and crew hygiene products, and implementation of advanced sorbents both on the air and water strings have been successful in reducing contaminant loads. Data on air and water quality for the last five years on ISS will be presented (nominal and contingency air grab samples, in-flight monitoring for air and water quality, and water samples from all segments of the ISS water system), including some notable events. The available data demonstrate the performance of existing ECLS systems and overall status of how the approach to air and water quality have evolved through the new ISS architecture baseline operations.

air quality↗

Impact of Porous Transport Layer In-Plane Conduction on Spatially Resolved Current and EIS Measurements in a Proton Exchange Membrane Water Electrolyzer

An XY segmented cell was developed for low temperature PEM water electrolysis (PEMWE). The system can assess the local performance by enabling in situ measurements of spatial currents and impedances. In this work, we show through experiments, as well as through modelling work, that the porous transport layer (PTL) must be segmented to eliminate crosstalk. Accurate measurements are only possible when crosstalk is fully eliminated. The XY segmented cell is applied to a case study characterizing the impact of a PTL platinum coating void on spatial performance. The localized performance impact of the coating void is found to be orientation specific: coating voids facing the catalyst layer reduce performance significantly more than coating voids facing the flow field. The results suggest that the tolerances for PTL coating uniformity can be lower at the side facing the flow field. The work showcases the feasibility of the XY segmented cell for impact assessment studies. The presented XY segmented cell enables the characterization of spatial phenomena in PEMWE devices and is envisioned to support modeling efforts and the investigation of manufacturing related tolerances for mass produced PEMWE devices.

08 HYDROGEN↗

Combining Distributed Electrochemical Measurements with a Semi-Empirical Model to Identify Local Variations in Overpotentials for PEM Water Electrolyzers

Abstract A segmented cell and PCB approach was used to demonstrate an advanced technique for measuring and understanding the electrochemical behavior of PEM water electrolyzers. By employing a semi-empirical model, discrete modes of overpotential and their spatial distributions were identified in an operating cell. Distributed area-specific resistance (DASR measurements indicate that local dehydration of the polymer electrolyte membrane is the primary driver of increased polarization, behaving similarly to mass transport-limited currents at low flow rates due to ineffective gas-phase bubble removal. To improve quantification, the overall ohmic overpotential is divided into background (η Ohm,b ) and mass transport-coupled (η Ohm,mt ) components. Two types of anode diffusion media, a baseline PTL and a thin foil liquid/gas diffusion layer (LGDL), were examined. The results show significant variations in η Ohm,b and highlight that ineffective bubble removal leads to pronounced local dehydration. The effect of cell temperature on various overpotentials was also examined. Negligible differences in diffusion overpotential were observed when comparing PEWE performance using the PTL and LGDL, despite major differences in two-phase fluid transport within each diffusion media. This underscores the critical role of the catalyst layer's micro-porous structure in diffusion processes. The study highlights the complex nature and intricacies of mass transport limitations within PEWEs.

Roy, Anirban (ORCID:0000000163803386)↗

The discrimination of sea ice types using SAR backscatter statistics

X-band (HH) synthetic aperture radar (SAR) data of sea ice collected during the Marginal Ice Zone Experiment in March and April of 1987 was statistically analyzed with respect to discriminating open water, first-year ice, multiyear ice, and Odden. Odden are large expanses of nilas ice that rapidly form in the Greenland Sea and transform into pancake ice. A first-order statistical analysis indicated that mean versus variance can segment out open water and first-year ice, and skewness versus modified skewness can segment the Odden and multilayer categories. In additions to first-order statistics, a model has been generated for the distribution function of the SAR ice data. Segmentation of ice types was also attempted using textural measurements. In this case, the general co-occurency matrix was evaluated. The textural method did not generate better results than the first-order statistical approach.

Shuchman, Robert A.↗

Water impact test of aft skirt end ring, and mid ring segments of the Space Shuttle Solid Rocket Booster

The results of water impact loads tests using aft skirt end ring, and mid ring segments of the Space Shuttle Solid Rocket Booster (SRB) are examined. Dynamic structural response data is developed and an evaluation of the model in various configurations is presented. Impact velocities are determined for the SRB with the larger main chute system. Various failure modes are also investigated.

Source record↗

Characterization of Electrochemically Generated Silver

Silver biocide offers a potential advantage over iodine, the current state of the art in US spacecraft disinfection technology, in that silver can be safely consumed by the crew. Low concentrations of silver (<500 ppb) have been shown to kill bacteria in water systems and keep it safe for potability. Silver does not require hardware to remove it from a water system, and therefore can provide a simpler means for disinfecting water. The Russian segment of the International Space Station has utilized an electrochemically generated silver solution, which is colloidal in nature. To be able to reliably provide a silver biocide to drinking water by electrochemical means would reduce mass required for removing another biocide such as iodine from the water. This would also aid in crew time required to replace iodine removal cartridges. Future long term missions would benefit from electrochemically produced silver as the biocide could be produced on demand and requires only a small concentration to be effective. Since it can also be consumed safely, there is less mass in removal hardware and little consumables required for production. The goal of this project initially is to understand the nature of the electrochemically produced silver, the particle sizes produced by the electrochemical cell and the effect that voltage adjustment has on the particle size. In literature, it has been documented that dissolved oxygen and pH have an effect on the ionization of the electrochemical silver so those parameters would be measured and possibly adjusted to understand their effect on the silver.

Adam, Niklas↗

Development of the Underwater Disc Saw Used to Segment the Internals of Taiwan Research Reactor - 20038

Taiwan Research Reactor will be dismantled in the period of 2022 to 2027 according to the approved dismantling plan. Based on the sampling and analyzing results, some internals of Taiwan Research Reactor must be segmented under the water because of their higher radiation, and the calandria is one of them. To dismantle this calandria, Institute of Nuclear Energy Research develops an underwater disc saw that is driven by a hydraulic pump and will be used to segment the shell of the calandria. In this article, Taiwan Research Reactor and the structure of the calandria are briefly depicted, and the segmentation processes of this calandria and the design of this disc saw are also included. Besides, the trial of cutting the shell of the simplified full size calandria mockup is briefly demonstrated in this article. Further tests will be performed in the near future to figure out which parts or functions of this disc saw need to be modified to get better cutting performance. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Segmentation Of Multifrequency Complex-Amplitude SAR Data

Several mathematical models and associated algorithms implement method of segmenting multifrequency, highly speckled, high-resolution, complex-amplitude (amplitude and phase) synthetic-aperture-radar (SAR) digitized image into regions, within each of which radar backscattering characteristics are similar or homogeneous from place to place. Typically, each region represents different type of terrain or other surface; e.g., forest, agricultural land, sea ice, or water. Method of segmentation of SAR scene into regions is product of generalization, to multifrequency case, of single-frequency method described in "Algorithms for Segmentation of Complex-Amplitude SAR Data" (NPO-18524).

Rignot, Eric J.↗

Evaluation of the Biocidal Efficacy of Different Forms of Silver Against Cupriavidus (formerly Wautersia) Species Bacteria

Contingency Water Containers (CWCs) are used to store potable and technical water that is transferred to the International Space Station (ISS) from the Shuttle orbiter vehicles. When CWCs are filled, water from the orbiter galley is passed through an ion exchange/activated carbon cartridge that removes the residual iodine biocide used on Shuttle before silver biocide is added. Removal of iodine and addition of silver is necessary to inhibit microbial growth inside CWCs and maintain compatibility with the water systems in the Russian segment of ISS. As part of nominal water transfer activities, crewmembers collect samples from several CWCs for postflight analysis. Results from the analysis of water transfer samples collected during the docked phases of STS-118/13A.1 and STS-120/10A showed that several of the CWCs contained up to 10(exp 4) CFU/mL of bacteria despite the fact that the silver concentrations in the CWCs were within acceptable limits. The samples contained pure cultures of a single bacteria, a Cupriavidus (formerly Wautersia) species that has been shown to be resistant to metallic biocides. As part of the investigation into the cause and remediation of the bacterial contamination in these CWCs, ground studies were initiated to evaluate the resistance of the Cupriavidus species to the silver biocides used on ISS and to determine the minimum effective concentration for the different forms of silver present in the biocides. The initial findings from those experiments are discussed herein.

Gazda, Daniel B.↗

Late day measurement of excised branches results in uncertainty in the estimation of two stomatal parameters derived from response curves in Populus deltoides Bartr. x Populus nigra L.

Many terrestrial biosphere models depend on an understanding of the relationship between stomatal conductance and photosynthesis. However, unlike the measurement of photosynthetic parameters, such as the maximum carboxylation capacity, where standard methods (e.g., CO 2 response or ACi curves) are widely accepted, a consensus method for empirically measuring parameters representing stomatal response has not yet emerged. Most models of stomatal response to environment represent stomatal conductance as being bounded by a lower intercept parameter (g 0 ), and linearly scaled based on a multivariate term described by the stomatal slope parameter (g 1 ). Here we employ the widely used Unified Stomatal Optimization model, to test whether g 1 and g 0 parameters are impacted by the choice of measurement method, either on an intact branch, or a cut branch segment stored in water. We measured paired stomatal response curves on intact and excised branches of a hybrid poplar clone (Populus deltoides Bartr. x Populus nigra L. OP367), measured twice over a diurnal period. We found that predawn branch excision did not significantly affect measured g 0 and g 1 when measured within 4 h of excision. Measurement in the afternoon resulted in significantly higher values of g 1 and lower values of g0, with values changing by 55% and 56% respectively. Excision combined with afternoon measurement resulted in a marked effect on parameter estimates, with g1 increasing 89% from morning to afternoon and a 25% lower g 1 for cut branches than those measured in situ. We also show that in hybrid poplar the differences in parameter estimates obtained from plants measured under different conditions can directly impact models of canopy function, reducing modeled transpiration by 18% over a simulated 12.5-hour period. While these findings are only for a single isohydric woody species, our findings suggest that stomatal optimality parameters may not remain constant throughout the day.

54 ENVIRONMENTAL SCIENCES↗

History, Current Operations and Management of Water Systems on the International Space Station

In November 2000, the Expedition 1 crew to the International Space Station (ISS) arrived onboard, thus beginning a 19+ year need to provide potable water to the crew, as well as water to key life support systems. For the first 8 years of ISS operations, the water systems' operations were relatively simple. It consisted of manifesting water via cargo ships or generated via the Space Shuttle fuel cells and stored on ISS to supplement the water processing systems on the Russian segment of the ISS. In 2008, the Water Processor Assembly (WPA), Urine Processor Assembly (UPA), along with a U.S. provided toilet arrived onboard, supplementing the Oxygen Generator Assembly (OGA). This new equipment, known as Regen ECLSS (Regenerative Environmental Control and Life Support Systems), provided a significant capability in recycling fluid within the ISS and minimized manifestation needs. Early in the operations of the Regen ECLSS system, it became clear that the tank capacities were under sized. This led to excessive use of costly crew time to perform water operations. In 2012, a group of ISS flight controllers and engineers proposed and developed a new system that would provide integrated water tanks that could be fully operated from Mission Control on the ground to move water around within the systems. This system has very recently been installed on the ISS and commissioning operations have occurred. This paper will provide a general history of water operations on the ISS, as new systems arrived, and new operations were required. Challenges with water balance, to both avoid overfilling the system as well as avoid running out of water, will be discussed, along with touching on the convoluted steps the Flight Control team had to perform daily to predict future water needs. Finally, the new water storage system will be discussed and the benefits it brings to ISS water operations.

Christopher A Brown↗

International Space Station USOS Potable Water Dispenser On-Orbit Functionality vs Design

The International Space Station (ISS) currently provides potable water dispensing for rehydrating crewmembers food and drinking packages with one system located in the United States On-orbit Segment (USOS) and one system in the Russian Segment. The USOS Potable Water Dispenser (PWD) was delivered to ISS on ULF2, Shuttle Mission STS-126, and was subsequently activated in November 2008. The PWD activation on ISS is capable of supporting an ISS crew of six but nominally supplies only half the crew. The PWD is designed to provide incremental quantities of hot and ambient temperature potable water to US style food packages. PWD receives iodinated water from the US Laboratory Fuel Cell Water Bus, which is fed from the Water Processing Assembly (WPA). The PWD removes the biocidal iodine to make the water potable prior to dispensing. A heater assembly contained within the unit supplies up to 2.0 liters of hot water (65 to 93oC) every thirty minutes. This quantity supports three to four crewmembers to rehydrate their food and beverages from this location during a single meal. The unit is designed to remain functional for up to ten years with replacement of limited life items such as filters. To date, the PWD on-orbit performance has been acceptable. Since activation of the PWD, there have been several differences between on-orbit functionality and expected performance of hardware design. The comparison of on-orbit functionality to performance of hardware design is outlined for the following key areas: microbiology, PWD to food package water leakage, no-dispense scenarios, under-dispense scenarios, and crewmember feedback on actual on-orbit use.

Toon, Katherine P.↗

Regenerative (Regen) ECLSS Operations Water Balance

In November 2008, the Water Regenerative System racks were launched aboard Space Shuttle flight, STS-126 (ULF2) and installed and activated on the International Space Station (ISS). These racks, consisting of the Water Processor Assembly (WPA) and Urine Processor Assembly (UPA), completed the installation of the Regenerative (Regen) ECLSS systems which includes the Oxygen Generator Assembly (OGA) that was launched 2 years prior. With the onset of active water management on the US segment of the ISS, a new operational concept was required, that of "water balance." Even more recently, in 2010 the Sabatier system came online which converts H2 and CO2 into water and methane. The Regen ECLSS systems accept condensation from the atmosphere, urine from crew, and processes that fluid via various means into potable water which is used for crew drinking, building up skip-cycle water inventory, and water for electrolysis to produce oxygen. Specification rates of crew urine output, condensate output, O2 requirements, toilet flush water and drinking needs are well documented and used as a general plan when Regen ECLSS came online. Spec rates are useful in long term planning, however, daily or weekly rates are dependent on a number of variables. The constantly changing rates created a new challenge for the ECLSS flight controllers, who are responsible for operating the ECLSS systems onboard ISS. This paper will review the various inputs to rate changes and inputs to planning events, including but not limited to; crew personnel makeup, Regen ECLSS system operability, vehicle traffic, water containment availability, and Carbon Dioxide Removal Assembly (CDRA) capability. Along with the inputs that change the various rates, the paper will review the different systems, their constraints and finally the operational means by which flight controllers manage this new challenge of "water balance."

Tobias, Barry↗

International Space Station Water Balance Operations

In November 2008, the Water Regenerative System racks were launched aboard Space Shuttle flight, STS-126 (ULF2) and installed and activated on the International Space Station (ISS). These racks, consisting of the Water Processor Assembly (WPA) and Urine Processor Assembly (UPA), completed the installation of the Regenerative (Regen) Environmental Control and Life Support Systems (ECLSS), which includes the Oxygen Generation Assembly (OGA) that was launched 2 years prior. With the onset of active water management on the US segment of the ISS, a new operational concept was required, that of water balance . In November of 2010, the Sabatier system, which converts H2 and CO2 into water and methane, was brought on line. The Regen ECLSS systems accept condensation from the atmosphere, urine from crew, and processes that fluid via various means into potable water, which is used for crew drinking, building up skip-cycle water inventory, and water for electrolysis to produce oxygen. Specification (spec) rates of crew urine output, condensate output, O2 requirements, toilet flush water, and drinking needs are well documented and used as the best guess planning rates when Regen ECLSS came online. Spec rates are useful in long term planning, however, daily or weekly rates are dependent upon a number of variables. The constantly changing rates created a new challenge for the ECLSS flight controllers, who are responsible for operating the ECLSS systems onboard ISS from Mission Control in Houston. This paper reviews the various inputs to water planning, rate changes, and dynamic events, including but not limited to: crew personnel makeup, Regen ECLSS system operability, vehicle traffic, water storage availability, and Carbon Dioxide Removal Assembly (CDRA), Sabatier, and OGA capability. Along with the inputs that change the various rates, the paper will review the different systems, their constraints, and finally the operational challenges and means by which flight controllers manage this new concept of "water balance."

Tobias, Barry↗

Market trends

A very large segment of the over water, long haul passenger market, 31% of the passengers who provide 42% of the passenger revenue, offers a significant market for an advanced supersonic transport. This is for both the first class and full-fare economy passenger markets. The supersonic transport may be more competitive here in spite of lower costs of subsonic transports, as passenger preference is a more powerful variable than DOC. This latter fact was amply demonstrated in the late fifties when the jets completely replaced the reciprocating engine transports on most world routes, in spite of slightly higher fares.

Fitzsimmons, R. D.↗