Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “water heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Infant burn injuries related to water heating for powdered infant formula preparation

Guidance for preparing powdered infant formula (PIF) helps to ensure it meets the nutritional needs of infants and is safe to consume. Among safety concerns is Cronobacter sakazakii contamination which can lead to serious infections and death. PIF preparation guidance varies; there is a lack of consensus on whether there is a need to boil water to inactivate potential Cronobacter and for how long to let the water cool before reconstitution. We sought to quantify the burden of burn injuries among infants related to water heating for PIF preparation. Estimating this burden may help inform preparation recommendations. Burn injuries among infants <18 months of age were identified from 2017 to 2019 National Electronic Injury Surveillance System data collected from sampled hospital emergency departments. Injuries were classified as related to PIF water heating, potentially related to PIF water heating but with undetermined causation, related to other infant feeding aspects, or unrelated to infant formula or breast milk feeding. Unweighted case counts for each injury classification were determined. Across sampled emergency departments, 7 PIF water heating injuries were seen among the 44,395 injuries reported for infants <18 months. No reported PIF water heating injuries were fatal, but 3 required hospitalization. Another 238 injuries potentially related to PIF water heating but with undetermined causation were also seen. Preparation guidance should consider both the potential risk for Cronobacter infection and the potential risk for burns.

60 APPLIED LIFE SCIENCES↗

Cold Start of a Radiator Equipped with Titanium-Water Heat Pipes

Radiator panels utilizing titanium-water heat pipes are being considered for lunar applications. A traditional sandwich structure is envisioned where heat pipes are embedded between two high thermal conductivity face sheets. The heat pipe evaporators are to be thermally connected to the heat source through one or more manifolds containing coolant. Initial radiator operation on the lunar surface would likely follow a cold soak where the water in the heat pipes is purposely frozen. To achieve heat pipe operation, it will be necessary to thaw the heat pipes. One option is to allow the sunlight impinging on the surface at sunrise to achieve this goal. Testing was conducted in a thermal vacuum chamber to simulate the lunar sunrise and additional modeling was conducted to identify steady-state and transient response. It was found that sunlight impinging on the radiator surface at sunrise was insufficient to solely achieve the goal of thawing the water in the heat pipes. However, starting from a frozen condition was accomplished successfully by applying power to the evaporators. Start up in this fashion was demonstrated without evaporator dryout. Concern is raised over thawing thermosyphons, vertical heat pipes operating in a gravity field, with no wick in the condenser section. This paper presents the results of the simulated cold start study and identifies future work to support radiator panels equipped with titanium-water heat pipes.

Jaworske, Donald A.↗

Transient characteristics of a grooved water heat pipe with variable heat load

The transient characteristics of a grooved water heat pipe were studied by using variable heat load. First, the effects of the property variations of the working fluid with temperature were investigated by operating the water heat pipe at several different temperatures. The experimental results show that, even for the same heat input profile and heat pipe configuration, the heat pipe transports more heat at higher temperature within the tested temperature range. Adequate liquid return to the evaporator due to decreasing viscosity of the working fluid permits continuous vaporization of water without dry-out. Second, rewetting of the evaporator was studied after the evaporator had experienced dry-out. To rewet the evaporator, the elevation of the condenser end was the most effective way. Without elevating the condenser end, rewetting is not straight-forward even with power turned off unless the heat pipe is kept at isothermal condition for sufficiently long time.

Jang, Jong Hoon↗

Solar-assisted gas-energy water-heating feasibility for apartments

Studies of residential energy use, solar-energy technology for buildings, and the requirements for implementing technology in the housing industry led to a project to develop a solar water heater for apartments. A design study for a specific apartment was used to establish a solar water-heater cost model which is based on plumbing contractor bids and manufacturer estimates. The cost model was used to size the system to minimize the annualized cost of hot water. The annualized cost of solar-assisted gas-energy water heating is found to be less expensive than electric water heating but more expensive than gas water heating. The feasibility of a natural gas utility supplying the auxiliary fuel is evaluated. It is estimated that gas-utilizing companies will find it profitable to offer solar water heating as part of a total energy service option or on a lease basis when the price of new base-load supplies of natural gas reaches $2.50-$3.00 per million Btu.

Davis, E. S.↗

Development of a nonazeotropic heat pump for crew hygiene water heating

A heat pump system is currently under development to produce hot water for crew hygiene on future manned space missions. The heat pump uses waste heat sources and a nonazeotropic working fluid in a highly efficient cycle. The potential benefits include a reduction in peak power draw from 2 to 5 kW for electric cartridge heaters to just more than 100 W for the heat pump. As part of the heat pump development project, a unique high efficiency compressor was developed to maintain lubrication in a zero-gravity environment.

Walker, David H.↗

Intermediate Temperature Water Heat Pipe Tests

Heat pipes are among the most promising technologies for space radiator systems. Water heat pipes are explored in the intermediate temperature range of 400 to above 500 K. The thermodynamic and thermo-physical properties of water are reviewed in this temperature range. Test data are reported for a copper-water heat pipe. The heat pipe was tested under different orientations. Water heat pipes show promise in this temperature range. Fabrication and testing issues are being addressed.

Devarakonda, Angirasa↗

Intermediate Temperature Water Heat Pipe Tests

Heat pipes are among the most promising technologies for space radiator systems. Water heat pipes are explored in the intermediate temperature range of 400 to above 500 K. The thermodynamic and thermo-physical properties of water are reviewed in this temperature range. Test Data are reported for a copper-water heat pipe. The heat pipe was tested under different orientations. Water heat pipes show promise in this temperature range.Fabrication and testing issues are being addressed.

Devarakonda, Angirasa↗

Optimal Energy Scheduling and Sensitivity Analysis for Integrated Power-Water-Heat Systems

The conventionally independent power, water, and heating networks are becoming more tightly connected, which motivates their joint optimal energy scheduling to improve the overall efficiency of an integrated energy system. However, such a joint optimization is known as a challenging problem with complex network constraints and couplings of electric, hydraulic, and thermal models that are nonlinear and nonconvex. We formulate an optimal power-water-heat flow (OPWHF) problem and develop a computationally efficient heuristic to solve it. The proposed heuristic decomposes OPWHF into subproblems, which are iteratively solved via convex relaxation and convex-concave procedure. Simulation results validate that the proposed framework can improve operational flexibility and social welfare of the integrated system, wherein the water and heating networks respond as virtual energy storage to time-varying energy prices and solar photovoltaic generation. Moreover, we perform sensitivity analysis to compare two modes of heating network control: by flow rate and by temperature. Our results reveal that the latter is more effective for heating networks with a wider space of pipeline parameters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Preliminary design package for Sunspot Domestic Hot Water Heating System

The design review includes a drawing list, auto-control logic, measurement definitions, and other document pertaining to the solar heated prototype hot water systems and two heat exchangers. The hot water systems consist of the following subsystems: collector, storage, control transport, auxiliary energy, and site data acquisition.

Source record↗

Water heating energy use reductions from EPA WaterSense lavatory plumbing fittings

Hot water savings from water-efficient lavatory fittings lead to reductions in water heating energy consumption, and ultimately to decreases in carbon emissions. This paper characterizes existing and proposed approaches used to estimate hot water savings and carbon emissions reductions stemming from the U.S. Environmental Protection Agency's WaterSense program. Also described are refinements that improve the accuracy of residential hot water use percentage estimates of lavatory fittings. The authors conclude that (1) hot water percentages for showers and faucets calculated using up-to-date, publicly available national data are consistent with those found by regional studies and household-level models of water use; (2) the accuracy of heating energy savings estimates attributable to WaterSense-labeled lavatory products, as well as associated emissions reductions, can be refined by modifying the existing energy factor/uniform energy factor (EF/UEF)-based estimation approach with available data. The refined approach accounts for more nuanced conditions than the EF/UED-based approach but depends on data not always available; and (3) the approaches described and intermediate outputs can be generalized for other water conservation programs or estimating purposes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Analysis of Combi Heat Pump System Configurations for Space Conditioning and Domestic Hot Water Heating in Residential Buildings

Combi heat pump systems, also referred to multifunctional variable refrigerant flow heat recovery (MF-VRFHR) systems, are specifically designed for residential applications to manage both space conditioning and domestic hot water (DHW). They have attracted attention due to their potential for energy conservation through heat recovery. The incorporation of a hot water tank introduces various system configurations, each characterized by distinct pros and cons related to energy efficiency, system stability, and maintenance. Despite this, a critical gap exists as the specific energy performance remains unquantified under diverse operational modes (e.g., heating mode and heat recovery mode). This paper aims to bridge this gap by conducting a comprehensive comparative analysis of two prevalent system configurations while considering feasible proposed control logics. Configuration 1 integrates a separate hot water tank and a refrigerant-to-water heat exchanger (HEX), also known as a Hydro Kit while Configuration 2 incorporates a refrigerant-wrapped hot water tank. To facilitate this analysis, we developed high-fidelity system models for both configurations in Modelica, capturing system dynamics and detailed control sequences effectively. These system models were built upon the TIL library for HVAC equipment components and the Buildings library for residential building thermal load calculations. The validation of the simulation testbed utilized data from experiments conducted in the PNNL lab home for Configuration 1. To establish the simulation testbed for Configuration 2, we extended the modeling setup derived from Configuration 1. This extension specifically involved substituting the separate hot water tank and Hydro Kit with a refrigerant-wrapped hot water tank of similar sizing sourced from an actual product. The simulation analysis of heating-only and heat recovery modes reveals that Configuration 2 not only saves energy and maintains warmer tank temperatures but also demonstrates faster water heating capabilities. This is attributed to decreased energy loss and improved heat transfer. The study encompasses a wide range of scenarios, considering diverse thermal loads and water usage patterns across heating and heat recovery modes. Overall, the comprehensive results indicate that Configuration 2 achieves energy savings ranging from 3.5% to 12.2% compared to Configuration 1, depending on factors such as water usage patterns, thermal loads, and operational modes.

Configuration, Comparison, Multi-functional, Resid↗

Residential Water Heating Demand Side Management (DSM) - South Africa

The electricity crisis in South Africa has deteriorated significantly, with the country experiencing frequent and prolonged rolling blackouts. These outages have severe economic repercussions, leading to decreased growth and productivity. Demand Side Management (DSM), particularly focusing on electric water heaters due to their significant energy consumption and peak demand contribution, is identified as a key strategy. The study aims to assess opportunities for DSM programs targeting water heating to reduce energy consumption and peak demand. It entails developing a bottom-up simulation model to establish a baseline scenario of water heating electricity load demand in 2023 and 2033, identifying technologies for energy reduction, estimating the impacts of a selected number of measures and providing recommendations to inform policy makers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling Assessment of Residential Air-to-Water Heat Pumps Coupled with Cooling Thermal Storage

This study explored the performance and operating cost viability of air-to-water heat pumps (AWHPs) coupled with thermal energy storage (TES) in efficient new residential construction. AWHPs are an emerging technology in this country, but offer promise in terms of high efficiency, fully contained and factory charged outdoor refrigeration system, and hydronic delivery capabilities, which facilitates zoning, ducts in conditioned space, and TES integration for summer load-shifting. Although this AWHP+TES strategy is not yet mainstream, the authors feel that in ten years as decarbonization efforts proceed and TOU rates become more common, strategies such as this will be more accessible. Validated EnergyPlus simulation models were developed based on detailed monitoring data collected over several years at Pacific Gas and Electric's CVRH laboratory test homes located in Stockton, California. One of the CVRH test homes (1,962 ft 2 two-story) had been testing various AWHP systems and configurations over the past six years. The validated model was then updated with high efficiency IECC ZERH envelope and component requirements for climate zones 1-5, including ducts in conditioned space thermal distribution. Simulations were completed for the 1,962 ft 2 home in each climate zone for a minimum efficiency ASHP, an AWHP coupled with a fan coil, and an AWHP coupled with TES sized to eliminate summer on-peak compressor operation. To maintain consistency in reporting energy use estimates, all cases were run with a similar indoor thermostat control strategy to pre-cool the house below the nominal 76 degrees Fahrenheit set point prior to the on-peak period and float slightly above the set point during the peak period. The AWHP+TES configuration was controlled to alternately condition the indoor space or to charge the TES tanks prior to the beginning of the on-peak. Three composite TOU rates were developed based on existing TOU rates across the U.S. to provide differing economic scenarios to evaluate customer bill impacts throughout the summer. Two of the TOU rates had short three-hour peak periods, while the third rate had a longer seven-hour duration peak period. AWHP modeling projections were based on the observed field performance of the Chiltrix CX34 variable speed unit. Other products on the market or entering the market in the near term would likely perform differently.

25 ENERGY STORAGE↗

Hydrogen evolution in nickel-water heat pipes.

A study was made of the evolution of hydrogen gas in nickel-water heat pipes for the purpose of investigating methods of accelerated life testing. The data were analyzed in terms of a phenomenological corrosion model of heat pipe degradation which incorporates corrosion and oxidation theory and contains parameters which can be determined by experiment. The gas was evolved with a linear time dependence and an exponential temperature dependence with an activation energy of 1.03 x 10 to the minus 19th joules. A flow-rate dependence of the gas evolution was found in the form of a threshold. The results were used to predict usable lifetimes of heat pipes operated at normal operating conditions from results taken under accelerated operating conditions.

Anderson, W. T.↗

Thermal performance of an absorption-assisted two-stage ejector air-to-water heat pump

In this work, a gas-fired air-to-water ejector heat pump (EHP) for domestic hot water production is proposed and analyzed thermodynamically. The COP of the EHP is improved by using binary fluids (HFE7500 and water), and the high backpressure in the primary ejector (first-stage) is actively controlled by either a second-stage ejector and/or a LiBr-H 2 O absorption subsystem. A thermodynamic model is established for analysis and performance evaluation. A case study shows the backpressure of the first-stage ejector is reduced by 53.5%, and the backpressure control using the second-stage ejector increases the system COP by 21.0% compared with that using LiBr-H 2 O absorption. Parametric studies are conducted to investigate the roles of the first-stage ejector, the second-stage ejector, and the LiBr-H 2 O absorption subsystem. The first-stage ejector plays a dominant role in the EHP system performance. The EHP’s heating COP can reach 2.0 with an entrainment ratio of 0.12 in the first-stage ejector. EHP performance can be improved with a high entrainment ratio and a low-temperature primary working fluid in the first-stage and second-stage ejectors, a low condensation temperature in the first-stage ejector, and a high generating temperature and a low concentration of the LiBr-H 2 O solution.

30 DIRECT ENERGY CONVERSION↗