Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “volumetric analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Origin of Tumor Recurrence After Intensity Modulated Radiation Therapy for Oropharyngeal Squamous Cell Carcinoma

Purpose: To model locoregional recurrences of oropharyngeal squamous cell carcinomas (OSCC) treated with primary intensity modulated radiation therapy (IMRT) in order to find the origins from which recurrences grow and relate their location to original target volume borders. Methods and Materials: This was a retrospective analysis of OSCC treated with primary IMRT between January 2002 and December 2009. Locoregional recurrence volumes were delineated on diagnostic scans and coregistered rigidly with treatment planning computed tomography scans. Each recurrence was analyzed with two methods. First, overlapping volumes of a recurrence and original target were measured ('volumetric approach') and assessed as 'in-field', 'marginal', or 'out-field'. Then, the center of mass (COM) of a recurrence volume was assumed as the origin from where a recurrence expanded, the COM location was compared with original target volume borders and assessed as 'in-field', 'marginal', or 'out-field'. Results: One hundred thirty-one OSCC were assessed. For all patients alive at the end of follow-up, the mean follow-up time was 40 months (range, 12-83 months); 2 patients were lost to follow-up. The locoregional recurrence rate was 27%. Of all recurrences, 51% were local, 23% were regional, and 26% had both local and regional recurrences. Of all recurrences, 74% had imaging available for assessment. Regarding volumetric analysis of local recurrences, 15% were in-field gross tumor volume (GTV), and 65% were in-field clinical tumor volume (CTV). Using the COM approach, we found that 70% of local recurrences were in-field GTV and 90% were in-field CTV. Of the regional recurrences, 25% were volumetrically in-field GTV, and using the COM approach, we found 54% were in-field GTV. The COM of local out-field CTV recurrences were maximally 16 mm outside CTV borders, whereas for regional recurrences, this was 17 mm. Conclusions: The COM model is practical and specific for recurrence assessment. Most recurrences originated in the GTV. This suggests radioresistance in certain tumor parts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hepatotoxic Dose Thresholds by Positron-Emission Tomography After Yttrium-90 Radioembolization of Liver Tumors: A Prospective Single-Arm Observational Study

PurposeTo define a threshold radiation dose to non-tumoral liver from {sup 90}Y radioembolization that results in hepatic toxicity using pair-production PET.Materials and MethodsThis prospective single-arm study enrolled 35 patients undergoing radioembolization. A total of 34 patients (27 with HCC and 7 with liver metastases) were included in the final analysis. Of 27 patients with underlying cirrhosis, 22 and 5 patients were Child–Pugh A and B, respectively. Glass and resin microspheres were used in 32 (94%) and 2 (6%) patients, respectively. Lobar and segmental treatment was done in 26 (76%) and 8 (24%) patients, respectively. Volumetric analysis was performed on post-radioembolization time-of-flight PET imaging to determine non-tumoral parenchymal dose. Hepatic toxicity was evaluated up to 120 days post-treatment, with CTCAE grade ≤ 1 compared to grade ≥ 2.ResultsThe median dose delivered to the non-tumoral liver in the treated lobe was 49 Gy (range 0–133). A total of 15 patients had grade ≤ 1 hepatic toxicity, and 19 patients had grade ≥ 2 toxicity. Patients with a grade ≥ 2 change in composite toxicity (70.7 vs. 43.8 Gy), bilirubin (74.1 vs. 43.3 Gy), albumin (84.2 vs. 43.8 Gy), and AST (94.5 vs. 47.1 Gy) have significantly higher non-tumoral parenchymal doses than those with grade ≤ 1. Liver parenchymal dose and Child–Pugh status predicted grade ≥ 2 toxicity, observed above a dose threshold of 54 Gy.ConclusionIncreasing delivered {sup 90}Y dose to non-tumoral liver measured by internal pair-production PET correlates with post-treatment hepatic toxicity. The likelihood of toxicity exceeds 50% at a dose threshold of 54 Gy.ClinicalTrials.gov identifier: NCT02848638.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The role of nuclear medicine in assessments of cardiac dyssynchrony

Radionuclide imaging has an advantage for quantitative analyses of the tracer concentration and its temporal changes. Myocardial perfusion and function have been adapted for synchrony analyses. Extracted parameters have been demonstrated to measure ventricular synchrony and even to predict CRT outcomes. ERNA has the advantages of higher temporal resolution, greater reproducibility, and the volumetric analysis of both ventricles that can be applied for analyses of intraventricular synchrony and interventricular synchrony. Several software packages such as Quantitative Gated SPECT, the Emory Cardiac Toolbox, cardioREPO, and Heart Function View are available to assess the LV dyssynchrony parameters from GSPECT. A count-based method is applied to extract the amplitude and phase from each of the reconstructed GSPECT short-axis datasets throughout the cardiac cycle and then subjected to a Fourier analysis, the results of which are displayed on a polar map and histogram. Some of the parameters such as the bandwidth (expressed as the 95% width of the phase histogram) and the standard deviation of the phase are obtained by the phase histogram to assess the intraventricular synchrony. This review paper focuses on the application of the LV dyssynchrony parameters estimated by cardiac SPECT in patients with a heart disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-284: Dose Plan Optimization When Using Hydrogel Prostate-Rectum Spacer: A Single Institution Experience

Purpose: To describe rectal dose reduction achieved and techniques used to take advantage of the increased peri-rectal spacing provided by injected polyethylene-glycol. Methods: Thirty prostate cancer patents were 2:1 randomized during a clinical trial to evaluate the effectiveness of injected poly-ethylene glycol hydrogel (SpaceOAR System) in creating space between the prostate and the anterior rectal wall. All patients received a baseline CT/MR scan and baseline IMRT treatment plan. Patients were randomized to receive hydrogel injection (n=20) or Control (n=10), followed by another CT/MR scan and treatment plan (single arc VMAT, 6 MV photons, 79.2 Gy, 44 fractions). Additional optimization structures were employed to constrain the dose to the rectum; specifically an avoidance structure to limit V75 <15%, and a control structure to limit the maximum relative dose <105% in the interface region of the anterior rectal wall and the prostate planning target volume. Dose volumetric data was analyzed for rectal volumes receiving 60 through 80 Gy. Results: Rectal dose reduction was observed in all patients who received the hydrogel. Volumetric analysis indicates a median rectal volume and (reduction from baseline plan) following spacer application of 4.9% (8.9%) at V60Gy, 3.8% (8.1%) at V65Gy, 2.5% (7.2%) at V70Gy, 1.6% (5.8%) at V75Gy, and 0.5% (2.5%) at V80Gy. Conclusion: Relative to planning without spacers, rectal dose constraints of 5%, 4%, 3%, 2%, 1% for V60, V65, V70, V75, and V80, should be obtainable when peri-rectal spacers are used. The combined effect of increased peri-rectal space provided by the hydrogel, with strict optimization objectives, resulted in reduced dose to the rectum. To maximize benefit, strict optimization objectives and reduced rectal dose constraints should be employed when creating plans for patients with perirectal spacers. Clinical Trial for SpaceOAR product conducted by Augmenix,Inc. The research site was paid to be a participating site.

60 APPLIED LIFE SCIENCES↗

Radiobiology for eye plaque brachytherapy and evaluation of implant duration and radionuclide choice using an objective function

Purpose: Clinical optimization of Collaborative Ocular Melanoma Study (COMS) eye plaque brachytherapy is currently limited to tumor coverage, consensus prescription dosage, and dose calculations to ocular structures. The biologically effective dose (BED) of temporary brachytherapy treatments is a function of both chosen radionuclide R and implant duration T. This study endeavored to evaluate BED delivered to the tumor volume and surrounding ocular structures as a function of plaque position P, prescription dose, R, and T. Methods: Plaque-heterogeneity-corrected dose distributions were generated with MCNP5 for the range of currently available COMS plaques loaded with sources using three available low-energy radionuclides. These physical dose distributions were imported into the PINNACLE{sup 3} treatment planning system using the TG-43 hybrid technique and used to generate dose volume histograms for a T = 7 day implant within a reference eye geometry including the ciliary body, cornea, eyelid, foveola, lacrimal gland, lens, optic disc, optic nerve, retina, and tumor at eight standard treatment positions. The equation of Dale and Jones was employed to create biologically effective dose volume histograms (BEDVHs), allowing for BED volumetric analysis of all ROIs. Isobiologically effective prescription doses were calculated for T = 5 days down to 0.01 days, with BEDVHs subsequently generated for all ROIs using correspondingly reduced prescription doses. Objective functions were created to evaluate the BEDVHs as a function of R and T. These objective functions are mathematically accessible and sufficiently general to be applied to temporary or permanent brachytherapy implants for a variety of disease sites. Results: Reducing T from 7 to 0.01 days for a 10 mm plaque produced an average BED benefit of 26%, 20%, and 17% for {sup 103}Pd, {sup 125}I, and {sup 131}Cs, respectively, for all P; 16 and 22 mm plaque results were more position-dependent. {sup 103}Pd produced a 16%-35% BED benefit over {sup 125}I, whereas {sup 131}Cs produced a 3%-7% BED detriment, independent of P, T, and plaque size. Additionally, corresponding organ at risk physical doses were lowest using {sup 103}Pd in all circumstances. Conclusions: The results suggest that shorter implant durations may correlate with more favorable outcomes compared to 7 day implants when treating small or medium intraocular lesions. The data also indicate that implant duration may be safely reduced if the prescription physical dose is likewise diminished and that {sup 103}Pd offers a substantial radiobiological benefit over {sup 125}I and {sup 131}Cs irrespective of plaque position, implant duration, and tumor size.

61 RADIATION PROTECTION AND DOSIMETRY↗

Ultra-low-dose limited renal CT for volumetric stone surveillance: advantages over standard unenhanced CT

Purpose: To describe and validate a novel CT approach using volumetric analysis for renal stone surveillance. Materials and methods: This prospective trial consisted of a standard low-dose non-contrast CT (SLD) of the abdomen and pelvis, immediately followed by an ultra-low-dose non-contrast CT (ULD) with reconstruction limited to the kidneys. A novel dedicated software tool was applied that automates stone volume, density, and maximum linear size. Manual linear stone size was measured by a radiology fellow and urology resident for comparison. CT dose and clinical charges were considered. Results: Twenty-eight stones in 16 patients were analyzed. Mean effective dose of ULD CT was 0.57 mSv, an average 92% lower than the SLD CT dose. For SLD, mean size ± SD (range) (mm) was 7.9 ± 6.2 (2.6–30.5) for Reader 1, 7.3 ± 6 (2.4–30.7) for Reader 2, and 9.3 ± 6.4 (3.7–33.1) for the automated software. For ULD, mean size ± SD (range) (mm) was 7.3 ± 6 (2.5–30.5) for Reader 1, 7.2 ± 6.1 (2.1–30.7) for Reader 2, and 9.1 ± 6.4 (4.2–32.8) for the automated software. Automated stone diameters were larger than manual diameters for 27/28 stones (mean difference, 23%); difference was ≥ 2 mm in 30%. Average variability between manual measurements was 8.6% (SLD) and 7.8% (ULD), but was 0% for the automated technique. Our institutional charge for ULD renal CT is slightly less than renal US, and > 4× less than SLD CT. The Medicare global fee for the ULD renal CT is less than the SLD CT of the abdomen and pelvis. Conclusions: This focused stone surveillance CT protocol is lower cost and lower dose compared to the standard CT approach. Automated assessment of stone burden provides improved reproducibility over manual linear measurement and offers the advantages of 3D measurements and volumetry. We now offer and perform this protocol in routine clinical practice for stone surveillance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Evaluation of Soft Tissue Organ Boundary Visualization on Cone-Beam Computed Tomographic Imaging

Purpose: Cone-beam computed tomographic images (CBCTs) are increasingly used for setup correction, soft tissue targeting, and image-guided adaptive radiotherapy. However, CBCT image quality is limited by low contrast and imaging artifacts. This analysis investigates the detectability of soft tissue boundaries in CBCT by performing a multiple-observer segmentation study. Methods and Materials: In four prostate cancer patients prostate, bladder and rectum were repeatedly delineated by five observers on CBCTs and fan-beam CTs (FBCTs). A volumetric analysis of contouring variations was performed by calculating coefficients of variation (COV: standard deviation/average volume). The topographical distribution of contouring variations was analyzed using an average surface mesh-based method. Results: Observer- and patient-averaged COVs for FBCT/CBCT were 0.09/0.19 for prostate, 0.05/0.08 for bladder, and 0.09/0.08 for rectum. Contouring variations on FBCT were significantly smaller than on CBCT for prostate (p < 0.03) and bladder (p < 0.04), but not for rectum (p < 0.37; intermodality differences). Intraobserver variations from repeated contouring of the same image set were not significant for either FBCT or CBCT (p < 0.05). Average standard deviations of individual observers' contour differences from average surface meshes on FBCT vs. CBCT were 1.5 vs. 2.1 mm for prostate, 0.7 vs. 1.4 mm for bladder, and 1.3 vs. 1.5 mm for rectum. The topographical distribution of contouring variations was similar for FBCT and CBCT. Conclusion: Contouring variations were larger on CBCT than FBCT, except for rectum. Given the well-documented uncertainty in soft tissue contouring in the pelvis, improvement of CBCT image quality and establishment of well-defined soft tissue identification rules are desirable for image-guided radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Space Station maintenance studies using plaid graphics

The Graphics Analysis Facility (GRAF) has been used frequently to study extravehicular activity (EVA) maintenance scenarios on Space Station Freedom. The ability to use 3-dimensional visualization gives one a more accurate estimate of the Space Station environment. Moreover, human EVA and robotic kinematics can be accurately simulated for columetric reach and collision detection analysis. An animation of this kind was developed for a research group at JSC to study and discover problem areas involved with doing external Space Station maintenance tasks. On the EVA side, it was discovered that items such as handholds and temporary restraint mechanisms should more effectively facilitate EVA movement about the Space Station structure for the suited personnel. Issues concerning CETA cart configuration, PWP storage locations, and locations of EVA storage areas were also identified by use of the animation. In the area of EVA versus robotics, it was found that there is a strong desire to make EVA and robotics interfaces compatible on items such as replacement units and unpressurized logistics carriers. The animation also showed that the use of robotics within an EVA task increases the difficulty and duration of the task setup, leaving less time available for the maintenance task itself. Graphics animation provides a mechanism to simultaneously analyze several mission parameters (i.e., EVA reach, volumetric analysis, and task timelines), and thus, it has proven to be an effective method for mission evaluation.

Helm, Mary E.↗

3D MRI in Musculoskeletal Imaging: Current and Future Applications

Purpose of Review: This article addresses current clinical applications, recent literature, and potential future applications of 3-dimensional magnetic resonance imaging (3D MRI) for musculoskeletal (MSK) applications. Recent Findings: The main advantage of 3D MRI over standard 2-dimensional MRI is its ability to reduce partial volume averaging artifacts and create multiplanar reconstruction (MPRs) in any plane with any slice thickness from a single high-resolution isotropic acquisition. 3D MRI acquisitions are particularly useful for the evaluation of articular cartilage, which is prone to volume averaging artifacts, and for the assessment of longitudinally coursing structures such as peripheral nerves and tendons, which are better visualized with non-orthogonal MPRs. 3D MRI is also useful for surface and volumetric analysis of bone and cartilage for preoperative and longitudinal assessments. Current research is focused on decreasing acquisition times and automating segmentation through machine learning, thus overcoming some of the current limitations of 3D MRI and providing new applications for this technique. Summary: 3D MRI is widely used in MSK imaging today, and its use is likely to continue to increase in the future, with recent advancements focused on accelerated acquisition techniques and quantitative imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Patterns of Recurrence in Electively Irradiated Lymph Node Regions After Definitive Accelerated Intensity Modulated Radiation Therapy for Head and Neck Squamous Cell Carcinoma

Purpose: To provide a comprehensive risk assessment on the patterns of recurrence in electively irradiated lymph node regions after definitive radiation therapy for head and neck cancer. Methods and Materials: Two hundred sixty-four patients with stage cT2-4N0-2M0 squamous cell carcinoma of the oropharynx, larynx, or hypopharynx treated with accelerated intensity modulated radiation therapy between 2008 and 2012 were included. On the radiation therapy planning computed tomography (CT) scans from all patients, 1166 lymph nodes (short-axis diameter ≥5 mm) localized in the elective volume were identified and delineated. The exact sites of regional recurrences were reconstructed and projected on the initial radiation therapy planning CT scan by performing coregistration with diagnostic imaging of the recurrence. Results: The actuarial rate of recurrence in electively irradiated lymph node regions at 2 years was 5.1% (95% confidence interval 2.4%-7.8%). Volumetric analysis showed an increased risk of recurrence with increasing nodal volume. Receiver operating characteristic analysis demonstrated that the summed long- and short-axis diameter is a good alternative for laborious volume calculations, using ≥17 mm as cut-off (hazard ratio 17.8; 95% confidence interval 5.7-55.1; P<.001). Conclusions: An important risk factor was identified that can help clinicians in the pretreatment risk assessment of borderline-sized lymph nodes. Not overtly pathologic nodes with a summed diameter ≥17 mm may require a higher than elective radiation therapy dose. For low-risk elective regions (all nodes <17 mm), the safety of dose de-escalation below the traditional 45 to 50 Gy should be investigated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evidence for lack of direct causality between pain and affective disturbances in a rat peripheral neuropathy model

Chronic pain is frequently accompanied by the manifestation of emotional disturbances and cognitive deficits. While a causality relation between pain and emotional/cognitive disturbances is generally assumed, several observations suggest a temporal dissociation and independent mechanisms. We therefore studied Sprague‐Dawley rats that presented a natural resistance to pain manifestation in a neuropathy model (spared nerve injury [SNI]) and compared their performance in a battery of behavioral paradigms—anxiety, depression and fear memory—with animals that presented a pain phenotype. Afterward, we performed an extensive volumetric analysis across prefrontal, orbitofrontal and insular cortical areas. The majority of SNI animals manifested mechanical allodynia (low threshold [LT]), but 13% were similar to Sham controls (high threshold [HT]). Readouts of spontaneous hypersensivity (paw flinches) were also significantly reduced in HT and correlated with allodynia. To increase the specificity of our findings, we segregated the SNI animals in those with left (SNI‐L) and right (SNI‐R) lesions and the lack of association between pain and behavior still remains. Left‐lesioned animals, independent of the LT or HT phenotype, presented increased anxiety‐like behaviors and decreased well‐being. In contrast, we found that the insular cortex (agranular division) was significantly smaller in HT than in LT. To conclude, pain and emotional disturbances observed following nerve injury are to some extent segregated phenomena. Also, HT and LT SNI presented differences in insular volumes, an area vastly implicated in pain perception, suggesting a supraspinal involvement in the manifestation of these phenotypes.

Guimarães, Marco R.↗

Geologic Assessment of the Carbon Sequestration Potential of Paleozoic Shale Gas Reservoirs in Alabama (Final Report)

Organic-rich shale formations are an increasingly important source of natural gas in the United States and have further been recognized to have large capacity for the geologic storage of carbon dioxide. Shale gas plays are active in Cambrian through Mississippian strata of the Appalachian thrust belt and Black Warrior basin of Alabama and are presently being evaluated for their resource and production potential. Gas shales are complex reservoirs and can hold gas both within matrix porosity and fractures, as well as adsorbed on organic matter and other mineral particles. Because of their unique storage duality, they have the ability to hold large volumes of gas, and thus are potentially valuable sinks for CO 2 . Using specific data on CO 2 storage, this study investigates the storage capacity of shale units in Alabama through isotherm and volumetric analysis and is part of research conducted under the Southeastern Regional Carbon Sequestration Partnership (SECARB) Phase III program. Previously, the only assessments of shale gas storage in the SECARB region were those based primarily on formation volume. The SECARB region is defined as the eleven southeastern states of Alabama, Arkansas, Florida, Georgia, Louisiana, Mississippi, North Carolina, South Carolina, Tennessee, Texas, and Virginia. Specifically, this study considers three potential shale sinks in Alabama. The Cambrian Conasauga Formation of the Appalachian thrust belt is geologically the oldest gas shale play in the world and is host to thousands of feet of deformed shale. Preliminary work by Koperna and others first suggested the massive storage potential of this unit. The Devonian Chattanooga Shale is widespread in much of the Black Warrior basin and vicinity and is also found along the margins of the thrust belt. Both of these areas have been sites of exploration and production. An additional thick, unnamed Silurian-Devonian shale exists within the interior of the thrust belt and was grouped with the Chattanooga Shale when calculating storage estimates. The Neal interval of the Mississippian Floyd Shale is found within the southern half of the Black Warrior basin and the southwestern part of the Appalachian thrust belt within facies-related carbonate and sandstone units, but has had limited production success.

54 ENVIRONMENTAL SCIENCES↗

Lunar and Planetary Science Conference, 13th, Houston, TX, March 15-19, 1982, Proceedings. Part 1

The present conference on planetary and lunar science considers theoretical models for the composition of the Venus crust, the lunar crust, the prediction of phase relationships in planetary mantles, the volumetric analysis of complex lunar craters, grazing impacts on Mars, the determination of lunar structure by means of electrical conductivity and seismic experiments, results of studies on the Apollo 16 site rocks, as well as Apollo 14, 15 and 17 lunar glasses and regoliths, and carbon components and isotopic compositions of chondritic meteorites. Also discussed are iron meteorites, interplanetary dust and tektites, and such theoretical and experimental issues as refractory condensates and chondrules from solar furnace experiments, molecular synthesis through the irradiation of silicates, and the adsorption of excess fission Xe.

Boynton, W. V.↗

Lunar and Planetary Science XXXVI, Part 1

Contents include the following: Observations with Near Infrared Spectrometer for Hayabusa Mission in the Cruising Phase. First Results of Quadrantid Meteor Spectrum. Compositional Investigation of Binary Near-Earth Asteroid 66063 (1998 RO1): A Potentially Undifferentiated Assemblage. Impact-induced Hydrothermal Activity on Early Mars. HRTEM and EFTEM Studies of Phyllosilicate-Organic Matter Associations in Matrix and Dark Inclusions in the EET92042 CR2 Carbonaceous Chondrite. Volumetric Analysis of Martian Rampart Craters. High Pressure Melting of H-Chondrite: A Match for the Martian Basalt Source Mantle. MERView: A New Computer Program for Easy Display of MER-acquired M ssbauer Data. Distribution, Exchange, and Topographic Control of Subsurface Ice on Mars. Shock-induced Damage Beneath Normal and Oblique Impact Craters. Amphitrites Patera Studied from the Mars Express HRSC Data. Oxygen Isotope Microanalysis of Enveloping Compound Chondrules in CV3 and LL3 Chondrites. Gamma-Ray Irradiation in the Early Solar System and the Conundrum of the Lu-176 Decay Constant. Magnesium Isotope Mapping of Silica-rich Grains Having. Extreme Oxygen Isotope Anomalies Extreme Oxygen Isotopic Anomalies from Irradiation in the Early Solar System, Re-Examining the Role of Chondrules in Producing the Elemental Fractionations in Chondrites. Meteorite Data on the Solar Modulation of Galactic Cosmic Rays and an Inference on the Solar Activity Influence on Climate of the Earth. Volatiles Enrichments and Composition of Jupiter. Thinking Like a Wildcatter Prospecting for Methane in Arabia Terra, Mars. Size Distribution of Genesis Solar Wind Array Collector Fragments. Initial Subdivision of Genesis Early Science Polished Aluminum Collector. Presolar Graphite and Its Noble Gases. Young Pb-Isotopic Ages of Chondrules in CB Carbonaceous Chondrites. Fe Isotopic Composition of Martian Meteorites. Petrology and Geochemistry of Nakhlite MIL 03346: A New Martian Meteorite from Antarctica.

Source record↗

Development of Human System Integration at NASA

Human Systems Integration seeks to design systems around the capabilities and limitations of the humans which use and interact with the system, ensuring greater efficiency of use, reduced error rates, and less rework in the design, manufacturing and operational deployment of hardware and software. One of the primary goals of HSI is to get the human factors practitioner involved early in the design process. In doing so, the aim is to reduce future budget costs and resources in redesign and training. By the preliminary design phase of a project nearly 80% of the total cost of the project is locked in. Potential design changes recommended by evaluations past this point will have little effect due to lack of funding or a huge cost in terms of resources to make changes. Three key concepts define an effective HSI program. First, systems are comprised of hardware, software, and the human, all of which operate within an environment. Too often, engineers and developers fail to consider the human capacity or requirements as part of the system. This leads to poor task allocation within the system. To promote ideal task allocation, it is critical that the human element be considered early in system development. Poor design, or designs that do not adequately consider the human component, could negatively affect physical or mental performance, as well as, social behavior. Second, successful HSI depends upon integration and collaboration of all the domains that represent acquisition efforts. Too often, these domains exist as independent disciplines due to the location of expertise within the service structure. Proper implementation of HSI through participation would help to integrate these domains and disciplines to leverage and apply their interdependencies to attain an optimal design. Via this process domain interests can be integrated to perform effective HSI through trade-offs and collaboration. This provides a common basis upon which to make knowledgeable decisions. Finally, HSI must be considered early in the requirements development phase of system design and acquisition. This will provide the best opportunity to maximize return on investment (ROI) and system performance. HSI requirements must be developed in conjunction with capability ]based requirements generation through functional. HSI requirements will drive HSI metrics and embed HSI issues within the system design. After a system is designed, implementation of HSI oversights can be very expensive. An HSI program should be included as an integral part of a total system approach to vehicle and habitat development. This would include, but not limited to, workstation design, D&C development, volumetric analysis, training, operations, and human -robotic interaction. HSI is a necessary process for Human Space Flight programs to meet the Agency Human ]System standards and thus mitigate human risks to acceptable levels. NASA has been involved in HSI planning, procedures development, process, and implementation for many years, and has been building several internal and publicly accessible products to facilitate HSI fs inclusion in the NASA Systems Engineering Lifecycle. Some of these products include: NASA STD 3001 Volumes 1 and 2, Human Integration Design Handbook, NASA HSI Implementation Plan, NASA HSI Implementation Plan Templates, NASA HSI Implementation Handbook, and a 2 ]hour short course on HSI delivered as part of the NASA Space and Life Sciences Directorate Academy. These products have been created leveraging industry best practices and lessons learned from other Federal Government agencies.

Whitmore, Mihriban↗

Adaptive Scalpel Scanning Probe Microscopy for Enhanced Volumetric Sensing in Tomographic Analysis

Controlling nanoscale tip‐induced material removal is crucial for achieving atomic‐level precision in tomographic sensing with atomic force microscopy (AFM). While advances have enabled volumetric probing of conductive features with nanometer accuracy in solid‐state devices, materials, and photovoltaics, limitations in spatial resolution and volumetric sensitivity persist. This work identifies and addresses in‐plane and vertical tip‐sample junction leakage as sources of parasitic contrast in tomographic AFM, hindering real‐space 3D reconstructions. Novel strategies are proposed to overcome these limitations. First, the contrast mechanisms analyzing nanosized conductive features are explored when confining current collection purely to in‐plane transport, thus allowing reconstruction with a reduction in the overestimation of the lateral dimensions. Furthermore, an adaptive tip‐sample biasing scheme is demonstrated for the mitigation of a class of artefacts induced by the high electric field inside the thin oxide when volumetrically reduced. This significantly enhances vertical sensitivity by approaching the intrinsic limits set by quantum tunneling processes, allowing detailed depth analysis in thin dielectrics. The effectiveness of these methods is showcased in tomographic reconstructions of conductive filaments in valence change memory, highlighting the potential for application in nanoelectronics devices and bulk materials and unlocking new limits for tomographic AFM.

36 MATERIALS SCIENCE↗

Influence of Air and Ethanol Dehydration on Structure, Behavior, and Function of Type I Collagen Scaffolds

Ethanol dehydration is a common step in both scaffold manufacturing and tissue processing, yet the influence of ethanol on collagen is not well understood. This study examined the effects of dehydration, via ethanol treatment and air drying, on collagen structure, behavior, mechanics, and rehydration capacity. Multiple material characterization methods were used including Fourier Transform infrared spectroscopy (FTIR), Raman spectroscopy, scanning electron microscopy, thermogravimetric analysis, small/medium angle x‐ray scattering, volumetric swelling analysis, and tensile testing. Ethanol dehydration removed bulk water from scaffolds, making them stronger and stiffer, but also showed loss of molecular water. This molecular water appears to act as a collagen stabilizer, resulting in less thermally stable scaffolds. The loss of molecular water is also evident in the molecular d‐spacing. Secondary structure of scaffolds was also altered by ethanol, resulting in significantly enhanced rehydration capacity. Bulk water, both before and after rehydration, largely determined mechanical properties, which did not correlate with other structural measures such as FTIR. While rehydration largely returned collagen spacing to pre‐ethanol treated state, structural alterations seen in FTIR cannot be recovered. These results have implications for not only collagen scaffolds, but in many tissue engineering and processing applications.

77 NANOSCIENCE AND NANOTECHNOLOGY↗