Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “volume determination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Determination of volume fraction in multiphase systems using incomplete pole figures

The determination of the volume fraction of a second phase in a multiphase sample by X-ray diffraction becomes more difficult if the diffracting planes have a preferred orientation. Lopata and Kula have described a method of treating this problem using complete pole figures for each of the phases. With some samples, it is not always possible or convenient to obtain data over the full hemisphere. Equations and an example are given which require X-ray data over a limited range of approximately 0 to 75 deg. This can be obtained by reflection without a specially cut sample or transmission data. A series of Legendre polynomials are fitted to data collected while spinning the sample about its normal. An extrapolation is made possible by introducing two conditions on the end points which must be satisfied if the extrapolation functions are to be valid.

Houska, C. R.↗

A dilatometer for volume-temperature determinations of liquids.

An instrument is described for the continuous volume measurement of small (3.7 ml) samples of liquids as a function of temperature. The sample is sealed in a stainless steel bellows chamber. Volume changes are measured with a linear variable differential transformer while temperature is measured by means of a thermistor and associated circuitry. Volume changes can be determined to better than .1 microliter ml over a temperature range of 10-60 C. The maximum sample volume change is 7%.

Rothman, J. E.↗

Method and system for determining a volume of an object from two-dimensional images

The invention provides a method and a computer program stored in a tangible medium for automatically determining a volume of three-dimensional objects represented in two-dimensional images, by acquiring at two least two-dimensional digitized images, by analyzing the two-dimensional images to identify reference points and geometric patterns, by determining distances between the reference points and the component objects utilizing reference data provided for the three-dimensional object, and by calculating a volume for the three-dimensional object.

Abercrombie, Robert K↗

Determination of volume fractions in two-phase flows from sound speed measurement

Accurate measurement of the composition of oil-water emulsions within the process environment is a challenging problem in the oil industry. Ultrasonic techniques are promising because they are non-invasive and can penetrate optically opaque mixtures. This paper presents a method of determining the volume fractions of two immiscible fluids in a homogenized two-phase flow by measuring the speed of sound through the composite fluid along with the instantaneous temperature. Two separate algorithms are developed by representing the composite density as (i) a linear combination of the two densities, and (ii) a non-linear fractional formulation. Both methods lead to a quadratic equation with temperature dependent coefficients, the root of which yields the volume fraction. The densities and sound speeds are calibrated at various temperatures for each fluid component, and the fitted polynomial is used in the final algorithm. We present results when the new algorithm is applied to mixtures of crude oil and process water from two different oil fields, and a comparison of our results with a Coriolis meter; the difference between mean values is less than 1%. Analytical and numerical studies of sensitivity of the calculated volume fraction to temperature changes and calibration errors are also presented.

02 PETROLEUM↗

What determines the volume of the oceans?

The volume of earth's oceans may be determined by a dynamic mechanism involving exchange of water between the crust and the mantle. Fast-spreading mid-ocean ridges are currently submerged to a depth at which the pressure is close to the critical pressure for seawater. This ensures optimal convective heat transport and, hence, maximal penetration of hydrothermal circulation along the ridge axes. The oceanic crust is hydrated to a depth of a kilometer or more and can therefore carry a substantial flux of water to the upper mantle when it is subducted. The current ingassing rate of water by this process is probably at least sufficient to balance the outgassing rate. If the oceans were shallower, as they may have been in the distant past, convective heat transport would be reduced and the depth of hydrothermal penetration and crustal hydration would decrease. Outgassing would exceed ingassing and ocean volume would increase. The system is self-stabilizing as long as the depth of the oceans does not exceed its present value. This mechanism could explain why continental freeboard has remained approximately constant since the Archean despite probable increases in continental area.

Kasting, James F.↗

Advanced application flight experiments precision attitude determination system. Volume 2: System tests

The performance capability of each of two precision attitude determination systems (PADS), one using a strapdown star tracker, and the other using a single-axis gimbal star tracker was measured in the laboratory under simulated orbit conditions. The primary focus of the evaluation was on the contribution to the total system accuracy by the star trackers, and the effectiveness of the software algorithms in functioning with actual sensor signals. A brief description of PADS, the laboratory test configuration and the test facility, is given along with a discussion of the data handling and display, laboratory computer programs, PADS performance evaluation programs, and the strapdown and gimbal system tests. Results are presented and discussed.

Source record↗

Pulmonary function evaluation during the Skylab and Apollo-Soyuz missions

Previous experience during Apollo postflight exercise testing indicated no major changes in pulmonary function. Pulmonary function has been studied in detail following exposure to hypoxic and hyperoxic normal gravity environments, but no previous study has reported on men exposed to an environment that was both normoxic at 258 torr total pressure and at null gravity as encountered in Skylab. Forced vital capacity (FVC) was measured during the preflight and postflight periods of the Skylab 2 mission. Inflight measurements of vital capacity (VC) were obtained during the last 2 weeks of the second manned mission (Skylab 3). More detailed pulmonary function screening was accomplished during the Skylab 4 mission. The primary measurements made during Skylab 4 testing included residual volume determination (RV), closing volume (CV), VC, FVC and its derivatives. In addition, VC was measured in flight at regular intervals during the Skylab 4 mission. Vital capacity was decreased slightly (-10%) in flight in all Skylab 4 crewmen. No major preflight-to-postflight changes were observed. The Apollo-Soyuz Test Project (ASTP) crewmen were studied using equipment and procedures similar to those employed during Skylab 4. Postflight evaluation of the ASTP crewmen was complicated by their inadvertent exposure to nitrogen tetroxide gas fumes upon reentry.

Sawin, C. F.↗

Comparison of Tumor Volumes as Determined by Pathologic Examination and FDG-PET/CT Images of Non-Small-Cell Lung Cancer: A Pilot Study

Purpose: To determine the cut-off standardized uptake value (SUV) on {sup 18}F fluoro-2-deoxy-glucose (FDG) positron emission tomography/computed tomography (FDG-PET/CT) images that generates the best volumetric match to pathologic gross tumor volume (GTV{sub path}) for non-small-cell lung cancer (NSCLC). Methods and Materials: Fifteen patients with NSCLC who underwent FDG-PET/CT scans followed by lobectomy were enrolled. The surgical specimen was dissected into 5-7-mum sections at approximately 4-mm intervals and stained with hematoxylin and eosin. The tumor-containing area was outlined slice by slice and the GTV{sub path} determined by summing over all the slices, taking into account the interslice thickness and fixation-induced volume reduction. The gross tumor volume from the PET images, GTV{sub PET}, was determined as a function of cut-off SUV. The optimal threshold or optimal absolute SUV was defined as the value at which the GTV{sub PET} was the same as the GTV{sub path}. Results: The fixation process induced a volumetric reduction to 82% +- 10% (range, 62-100%) of the original. The maximal SUV was 10.1 +- 3.6 (range, 4.2-18.7). The optimal threshold and absolute SUV were 31% +- 11% and 3.0 +- 1.6, respectively. The optimal threshold was inversely correlated with GTV{sub path} and tumor diameter (p < 0.05), but the optimal absolute SUV had no significant correlation with GTV{sub path} or tumor diameter (p > 0.05). Conclusion: This study evaluated the use of GTV{sub path} as a criterion for determining the optimal cut-off SUV for NSCLC target volume delineation. Confirmatory studies including more cases are being performed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Determination of fiber volume in graphite/epoxy materials using computer image analysis

The fiber volume of graphite/epoxy specimens was determined by analyzing optical images of cross sectioned specimens using image analysis software. Test specimens were mounted and polished using standard metallographic techniques and examined at 1000 times magnification. Fiber volume determined using the optical imaging agreed well with values determined using the standard acid digestion technique. The results were found to agree within 5 percent over a fiber volume range of 45 to 70 percent. The error observed is believed to arise from fiber volume variations within the graphite/epoxy panels themselves. The determination of ply orientation using image analysis techniques is also addressed.

Viens, Michael J.↗

Volume fraction determination of the annular three-phase flow of gas-oil-water using adaptive neuro-fuzzy inference system

The use of adaptive neuro-fuzzy inference system (ANFIS) has been reported for predicting the volume fractions in a gas–oil–water multiphase system. In fact, the volume fractions in the annular three-phase flow are measured based on a dual energy metering system consisting of {sup 152}Eu and {sup 137}Cs and one NaI detector using ANFIS. Since the summation of volume fractions is constant, therefore ANFIS must predict only two volume fractions. In this study, three ANFIS networks are applied. The first is utilized to predict the gas and water volume fractions. The next one is applied to predict the gas and oil, and the last one is used to predict the water and oil volume fractions. In the next step, ANFIS networks must be trained based on numerically obtained data from MCNP-X code. Then, the average testing errors of these three networks are computed and compared. The network with the least error has been selected as the best predictor model.

07 ISOTOPE AND RADIATION SOURCES↗

Ultrasonic measurement of porosity in casts and welds

The development of a quantitative nondestructive method which involves ultrasonic attenuation measurements in frequency domain to determine volume fraction of porosity in aluminum cast is discussed. The aluminum alloy A357 casting samples were produced at the Ohio State University Foundry with controlled porosity contents ranging from 0% to 6%. A computer controlled system was used to direct ultrasonic beam to a test sample to different places to conduct ultrasonic attenuation measurements. The plot of attenuation coefficients as a function of frequency was then evaluated based on existing theories to determine volume fraction of porosity and pore size.

Adler, L.↗

Estimation of Error in Maximal Intensity Projection-Based Internal Target Volume of Lung Tumors: A Simulation and Comparison Study Using Dynamic Magnetic Resonance Imaging

Purpose: To evaluate the error in four-dimensional computed tomography (4D-CT) maximal intensity projection (MIP)-based lung tumor internal target volume determination using a simulation method based on dynamic magnetic resonance imaging (dMRI). Methods and Materials: Eight healthy volunteers and six lung tumor patients underwent a 5-min MRI scan in the sagittal plane to acquire dynamic images of lung motion. A MATLAB program was written to generate re-sorted dMRI using 4D-CT acquisition methods (RedCAM) by segmenting and rebinning the MRI scans. The maximal intensity projection images were generated from RedCAM and dMRI, and the errors in the MIP-based internal target area (ITA) from RedCAM ({epsilon}), compared with those from dMRI, were determined and correlated with the subjects' respiratory variability ({nu}). Results: Maximal intensity projection-based ITAs from RedCAM were comparatively smaller than those from dMRI in both phantom studies ({epsilon} = -21.64% {+-} 8.23%) and lung tumor patient studies ({epsilon} = -20.31% {+-} 11.36%). The errors in MIP-based ITA from RedCAM correlated linearly ({epsilon} = -5.13{nu} - 6.71, r{sup 2} = 0.76) with the subjects' respiratory variability. Conclusions: Because of the low temporal resolution and retrospective re-sorting, 4D-CT might not accurately depict the excursion of a moving tumor. Using a 4D-CT MIP image to define the internal target volume might therefore cause underdosing and an increased risk of subsequent treatment failure. Patient-specific respiratory variability might also be a useful predictor of the 4D-CT-induced error in MIP-based internal target volume determination.

62 RADIOLOGY AND NUCLEAR MEDICINE↗