Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “voltage prediction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Nickel cadmium battery performance simulation - A means toward optimum design in satellite applications

It is noted that electrochemically based cell models can advance state-of-the-art battery prediction by allowing variations in the parameters that constitute wear-out and predict end-of-life performance. This modeling method is used as the foundation for the simulation of Ni-Cd battery performance. This simulation tool consists of a comprehensive computer model to be developed which would predict the voltage behavior of a battery under mission conditions.

Clark, K.↗

An Accelerated Life Testing Dataset for Lithium-Ion Batteries With Constant and Variable Loading Conditions

The dataset repository is organized into three main folders, each containing one group of life cycled battery packs. Within each folder individual battery packs own their dedicated csv file for continuous data logging, which are named with their respective battery pack number. The folders are named: - regular_alt_batteries: Containing one csv file for each battery pack cycled at the same load level or load range throughout lifetime - recommissioned_batteries: Containing one csv file for each battery pack cycled at different load levels at varying life stages - second_life_batteries: Containing one csv file for each second life battery pack cycled at constant current througout the second life

Li-ion Battery↗

Arcing rates for High Voltage Solar Arrays - Theory, experiment, and predictions

All solar arrays have biased surfaces that can be exposed to the space environment. It has been observed that when the array bias is less than a few hundred volts negative, then the exposed conductive surfaces may undergo arcing in the space plasma. A theory for arcing is developed on these high voltage solar arrays that ascribes the arcing to electric field runaway at the interface of the plasma, conductor, and solar cell dielectric. Experiments were conducted in the laboratory for the High Voltage Solar Array experiment that will fly on the Japanese Space Flyer Unit (SFU) in 1994. The theory was compared in detail with the experiment and shown to give a reasonable explanation for the data. The combined theory and ground experiments were then used to develop predictions for the SFU flight.

Hastings, Daniel E.↗

The arcing rate for a High Voltage Solar Array - Theory, experiment and predictions

All solar arrays have biased surfaces which can be exposed to the space environment. It has been observed that when the array bias is less than a few hundred volts negative then the exposed conductive surfaces may undergo arcing in the space plasma. A theory for arcing is developed on these high voltage solar arrays which ascribes the arcing to electric field runaway at the interface of the plasma, conductor and solar cell dielectric. Experiments were conducted in the laboratory for the High Voltage Solar Array (HVSA) experiment which will fly on the Japanese Space Flyer Unit (SFU) in 1994. The theory was compared in detail to the experiment and shown to give a reasonable explanation for the data. The combined theory and ground experiments were then used to develop predictions for the SFU flight.

Hastings, Daniel E.↗

Application of engineering codes to the assessment of spacecraft charging induced hazards

One of the major hurdles to developing a better understanding of the environmentally induced interactions in spacecraft systems (spacecraft charging) is the lack of simple tools to analyze the behavior of the spacecraft in a sub-storm environment. The available tool, NASA Charging Analyzer Program (NASCAP), is expensive to use and treats only half of the problem - surface effects only. In response to this need, we have developed, under our IRAD Program, a set of engineering tools that operate on personal computers and addresses both the surface and bulk charging aspects of the interactions. These engineering codes utilize circuit analysis techniques and model simplifications to allow rapid computations. The codes were compared to both NASCAP predictions and to bulk charging data with excellent agreement for both phenomena. The models used in our engineering codes are shown, and in the engineering codes, the models are defined in terms of plates or triangles in an unconfined space. The predictions are based upon current balances to each plate. The code has routines to allow interactions between the plates to simulate 'barrier' effects. The agreement for the predicted differential surface voltages for the model is given. In conducting the comparison of engineering codes to NASCAP predictions, it was found that some inconsistencies existed in the NASCAP code that are not obvious to the user. The use of the grid imposes constraints that voltage gradients exist between the grid points. This allows the existence of voltage gradients in conductors and influences surface resistivity predictions. These points are discussed along with the predictions for treating these inconsistencies properly. The model predictions for a variable intensity substorm is also presented.

Stevens, N. J.↗

Space Life Sciences Directorate's Position on the Physiological Effects of Exposing the Crewmemeber to Low-Voltage Electrical Hazards During Extravehicular Activity

The models predict that, for low voltage exposures in the space suit, physiologically active current could be conducted across the crew member causing catastrophic hazards. Future work with Naval Health Research Center Detachment Directed Energy Bio-effects Laboratory is being proposed to analyze additional current paths across the human torso and upper limbs. These models may need to be verified with human studies.

Hamilton, Douglas↗

Evaluation of high-energy lithium thionyl chloride primary cells

An advanced commercial primary lithium cell (LiSoCl2) was evaluated in order to establish baseline data for improved lithium batteries for aerospace applications. The cell tested had nominal capacity of 6 Ah. Maximum energy density at low rates (less than C/30, where C is the cell capacity in amp-hrs and 30 corresponds to a 30 hr discharge time) was found to be near 300 Wh/kg. An equation which predicts the operating voltage of these cells as a function of current and state of charge is presented. Heat generation rates of these cells were determined as a function of current in a calorimeter. It was found that heat rates could be theoretically predicted with some degree of accuracy at currents less than 1 amp or the C/6 rate. No explosions were observed in the cells during the condition of overdischarge or reversal nor during high rate discharge. It was found, however, that the cells can vent when overdischarge currents are greater than C/30 and when discharge rates are greater than 1.5C.

Frank, H. A.↗

SCATHA SSPM charging response: NASCAP predictions compared with data

Models for the satellite surface potential monitor (SSPM) units constructed in the NASCAP code and the results of comparing predictions to surface voltage and baseplate current data are reported. Several peculiarities in the test data are noted. Preliminary results from space simulations of a SCATHA model with environments representative of the day 87, 1979, eclipse injection event are presented, and their implications for predicting space response are discussed.

Purvis, C. K.↗

Off-Nominal Performance of the International Space Station Solar Array Wings Under Orbital Eclipse Lighting Scenarios

This paper documents testing and analyses to quantify International Space Station (ISS) Solar Array Wing (SAW) string electrical performance under highly off-nominal, low-temperature-low-intensity (LILT) operating conditions with nonsolar light sources. This work is relevant for assessing feasibility and risks associated with a Sequential Shunt Unit (SSU) remove and replace (R&R) Extravehicular Activity (EVA). During eclipse, SAW strings can be energized by moonlight, EVA suit helmet lights or video camera lights. To quantify SAW performance under these off-nominal conditions, solar cell performance testing was performed using full moon, solar simulator and Video Camera Luminaire (VCL) light sources. Test conditions included 25 to 110 C temperatures and 1- to 0.0001-Sun illumination intensities. Electrical performance data and calculated eclipse lighting intensities were combined to predict SAW current-voltage output for comparison with electrical hazard thresholds. Worst case predictions show there is no connector pin molten metal hazard but crew shock hazard limits are exceeded due to VCL illumination. Assessment uncertainties and limitations are discussed along with operational solutions to mitigate SAW electrical hazards from VCL illumination. Results from a preliminary assessment of SAW arcing are also discussed. The authors recommend further analyses once SSU, R&R, and EVA procedures are better defined.

Kerslake, Thomas W.↗

Comparison of currents predicted by NASCAP/LEO model simulations with elementary Langmuir-type bare probe models for an insulated cable containing a single pinhole

The behavior of a defect in the insulation of a short biased section of cable in a Low Earth Orbit (LEO) space environment was examined. Such studies are of the utmost importance for large space power systems where great quantities of cabling will be deployed. An insulated probe containing a pinhole was placed into a hypothetical high speed LEO plasma. The NASA Charging Analyzer Program (NASCAP/LEO) was used to explore sheath growth about the probe as a function of applied voltage and to predict I-V behavior. A set of independent current calculations using Langmuir's formulations for concentric spheres and coaxial cylinders were also performed. The case of concentric spheres was here extended to include the case of concentric hemispheres. Several simple Langmuir-type models were then constructed to bracket the current collected by the cable. The space-charge sheath radius and impact parameters were used to determine the proper current regime. I-V curves were plotted for the models and comparisons were made with NASCAP/LEO results. Finally, NASCAP/LEO potential contours and surface cell potential plots were examined to explain interesting features in the NASCAP/LEO I-V curve.

Galofaro, Joel T.↗

Empirical testing of an analytical model predicting electrical isolation of photovoltaic models

A major design requirement for photovoltaic modules is that the encapsulation system be capable of withstanding large DC potentials without electrical breakdown. Presented is a simple analytical model which can be used to estimate material thickness to meet this requirement for a candidate encapsulation system or to predict the breakdown voltage of an existing module design. A series of electrical tests to verify the model are described in detail. The results of these verification tests confirmed the utility of the analytical model for preliminary design of photovoltaic modules.

Garcia, A., III↗

AXAF-I Low Intensity-Low Temperature (LILT) Testing of the Development Verification Test (DVT) Solar Panel

The planned orbit of the AXAF-I spacecraft will subject the spacecraft to both short, less than 30 minutes for solar and less than 2 hours for lunar, and long earth eclipses and lunar eclipses with combined conjunctive duration of up to 3 to 4 hours. Lack of proper Electrical Power System (EPS) conditioning prior to eclipse may cause loss of mission. To avoid this problem, for short eclipses, it is necessary to off-point the solar array prior to or at the beginning of the eclipse to reduce the battery state of charge (SOC). This yields less overcharge during the high charge currents at sun entry. For long lunar eclipses, solar array pointing and load scheduling must be tailored for the profile of the eclipse. The battery SOC, loads, and solar array current-voltage (I-V) must be known or predictable to maintain the bus voltage within acceptable range. To address engineering concerns about the electrical performance of the AXAF-I solar array under Low Intensity and Low Temperature (LILT) conditions, Marshall Space Flight Center (MSFC) engineers undertook special testing of the AXAF-I Development Verification Test (DVT) solar panel in September-November 1997. In the test the DVT test panel was installed in a thermal vacuum chamber with a large view window with a mechanical "flapper door". The DVT test panel was "flash" tested with a Large Area Pulse Solar Simulator (LAPSS) at various fractional sun intensities and panel (solar cell) temperatures. The testing was unique with regards to the large size of the test article and type of testing performed. The test setup, results, and lessons learned from the testing will be presented.

Alexander, Doug↗

Solar wind control of the polar-cap voltage

The results of using various models to predict polar-cap potentials are reviewed. Quantitative predictions of merging rate, and hence of polar-cap voltage, based on subsolar merging models are reviewed, and tests of dayside merging models and their results are reexamined. Predictions and tests of cusp merging models are discussed. Two new empirical formulas for the dependence of the asymptotic polar-cap potential on the IMF are presented, and predictions of the dependence of dayside and lobe merging voltages on the IMF are derived from the antiparallel merging hypothesis.

Reiff, Patricia H.↗

The STD/MHD codes - Comparison of analyses with experiments at AEDC/HPDE, Reynolds Metal Co., and Hercules, Inc

Data from sufficiently well-instrumented, short-duration experiments at AEDC/HPDE, Reynolds Metal Co., and Hercules, Inc., are compared to analyses with multidimensional and time-dependent simulations with the STD/MHD computer codes. These analyses reveal detailed features of major transient events, severe loss mechanisms, and anomalous MHD behavior. In particular, these analyses predicted higher-than-design voltage drops, Hall voltage overshoots, and asymmetric voltage drops before the experimental data were available. The predictions obtained with these analyses are in excellent agreement with the experimental data and the failure predictions are consistent with the experiments. The design of large, high-interaction or advanced MHD experiments will require application of sophisticated, detailed and comprehensive computational procedures in order to account for the critical mechanisms which led to the observed behavior in these experiments.

Vetter, A. A.↗

South Atlantic Anomaly Entry and Exit as Measured by the X-Ray Timing Explorer

The Rossi X-ray Timing Explorer (RXTE) carries instruments that must switch off high voltages (HV) when passing through the South Atlantic Anomaly (SAA). The High Energy X-ray Timing Experiment (HEXTE) contains a particle monitor that detects the increased particle flux associated with the SAA and autonomously reduces its voltage. The Proportional Counter Array (PCA) relies on uplinked predictions of SAA entry/exit times based on ephemeris data provided by the Flight Dynamics Facility. A third instrument, the All-Sky Monitor (ASM) also uses a predicted SAA model to reduce voltage when passing through the SAA. Data collected from the HEXTE particle monitor, as well as other instrument readings near the times of SAA entry/exit offer the potential for refining models of the boundaries of the SAA. The SAA has an increased particle flux which causes high rates of detection in the RXTE instruments designed to observe x-rays. The high counting rates could degrade the PCA if HV is not reduced during SAA passages. On the other hand, PCA downtime can be minimized and the science return can be optimized by having the best possible model of the SAA boundary. Thus, the PCA team planned an extensive effort during in-orbit checkout to utilize both the HEXTE particle monitor data and instrument counting rates to refine the model of the SAA boundary. The times of SAA entry and exit are compared with the definitive epemeris to determine the precise location (latitude and longitude) of the SAA boundary. Over time, the SAA and its perimeter were mapped. The RXTE Science Operations Center is continuously working to feed back the results of this effort into the science scheduling process, improving the SAA model as it affects the RXTE instruments, thus obtaining more accurate estimates of the SAA entry/exit times.

Smith, Evan↗

Modelling and design of high performance indium phosphide solar cells

A first principles pn junction device model has predicted new designs for high voltage, high efficiency InP solar cells. Measured InP material properties were applied and device parameters (thicknesses and doping) were adjusted to obtain optimal performance designs. Results indicate that p/n InP designs will provide higher voltages and higher energy conversion efficiencies than n/p structures. Improvements to n/p structures for increased efficiency are predicted. These new designs exploit the high absorption capabilities, relatively long diffusion lengths, and modest surface recombination velocities characteristic of InP. Predictions of performance indicate achievable open-circuit voltage values as high as 943 mV for InP and a practical maximum AM0 efficiency of 22.5 percent at 1 sun and 27 C. The details of the model, the optimal InP structure and the effect of individual parameter variations on device performance are presented.

Rhoads, Sandra L.↗

Effects of high doping levels silicon solar cell performance

The significance of the heavy doping effects (HDE) on the open-circuit voltage of silicon solar cells is assessed. Voltage calculations based on diffusion theory are modified to include the first order features of the HDE. Comparisions of the open-circuit voltage measured for cells of various base resistivities are made with those calculated using the diffusion model with and without the HDE. Results indicate that the observed variation of voltage with base resistivity is predicted by these effects. A maximum efficiency of 19% (AM0) and a voltage of 0.7 volts are calculated for 0.1 omega-cm cells assuming an optimum diffused layer impurity profile.

Godlewski, M. P.↗

Effects of high doping levels on silicon solar cell performance

Open-circuit voltages measured in silicon solar cells made from 0.01 ohm-cm material are 150 mV lower than voltages calculated from simple diffusion theory and cannot be explained by poor diffusion lengths or surface leakage currents. An analytical study was made to determine whether high doping effects, which increase the intrinsic carrier concentration, could account for the low observed voltages and to determine the limits on voltage and efficiency imposed by high doping effects. The results indicate that the observed variation of voltage with base resistivity is predicted by these effects. A maximum efficiency of 19% (AMO) and a voltage of 0.7 volts were calculated for 0.1 ohm-cm cells assuming an optimum diffused layer impurity profile.

Godlewski, M. P.↗