Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “voltage magnitude estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Field‐representative evaluation of PID‐polarization in TOPCon PV modules by accelerated stress testing

Abstract Potential‐induced degradation‐polarization (PID‐p) can reduce module power, but how to project the extent to which PID‐p may occur in field conditions considering the factors of system voltage, condensed moisture, temperature, and illumination has not been clarified. Using tunnel oxide passivated contact (TOPCon) modules, this work demonstrates a method to test full‐size crystalline silicon PV modules for PID‐p to provide field‐representative results. In initial screening tests with positive or negative 1000 V electrical bias applied at 60°C for 96 h using Al foil electrodes on the glass surfaces, the module type exhibited reversible PID‐p only on the front face when the cell circuit was in negative voltage potential. No PID was detected on the rear after testing in either polarity. We then evaluated the PID‐p sensitivity on the front side under different UV irradiances while maintaining the glass surface wet to estimate real‐world susceptibility to PID‐p. The magnitude of the observed behavior was fit using a previously developed charge transfer and depletion by light model. Whereas power loss with −1000 V applied to the cell circuit at 60°C for 96 h in the dark was about 30%, testing the module front under 0.051 W·m −2 nm −1 at 340 nm UVA irradiation using fluorescent tubes, the mean degradation was only 3%. When the modules were tested in the dark for PID‐p with in situ dark current–voltage (I‐V) characterization, the thermal activation energy for degradation was 0.71 eV; for recovery in the dark, it was 0.58 eV. Whereas recovery from the degraded state at 60°C in the dark without voltage bias was 5% absolute in 38 h, rapid recovery of about 5% absolute was observed with 1000 W·s/m 2 exposure at 25°C using a flash tester.

14 SOLAR ENERGY↗

Leveraging Structures in Fault Diagnosis for Lithium-Ion Battery Packs

Lithium-ion battery systems consist of a varying number of single cells, designed to meet specific application requirements for output voltage and capacity. Effective fault diagnosis in these battery systems is an essential prerequisite for ensuring their safe and reliable operation. To address this need, we introduce a novel model-based fault diagnosis approach that distinguishes itself by leveraging informative structures inherent in battery systems such as architecture, uniformity among the constituent cells, and sparsity of fault occurrences to enhance its fault diagnosis capabilities. The proposed approach formulates a moving horizon estimation (MHE) problem, incorporating such structural information to estimate different fault signals—specifically, internal short circuits, external short circuits, and voltage and current sensors faults. We conduct various simulations to evaluate the performance of the proposed approach under different fault types and magnitudes. The obtained results validate the proposed approach and promise effective fault diagnosis for battery systems.

Farakhor, Amir↗

Cr(+2) Diffusion Doping in ZnSe

Chromium doped zinc selenides crystals have recently been demonstrated to be a promising material for near-IR room temperature tunable lasers which has an emission range of 2-3 pm. In this study, a new diffusion doping process has been developed for incorporation of Cr(+2) ion into ZnSe wafers. This process has been successfully performed under isothermal conditions, at temperatures above 800 degrees Celsius. Concentrations in excess of 10(exp 19) Cr(+2) ions/cu cm, an order of magnitude larger than previously reported in melt grown ZnSe material, have been obtained. The diffusivity was estimated to be about 10-* sq cm/sec using a classical diffusion model. Resistivity was derived from current-voltage measurements and in the 107-10(exp 16) Ohms-cm and increased as function of Cr concentration.

Journigan, Troy D.↗

Joint Estimation of Topology and Injection Statistics in Distribution Grids with Missing Nodes

Optimal operation of distribution grid resources relies on accurate estimation of its state and topology. Practical estimation of such quantities is complicated by the limited presence of real-time meters. This article discusses a theoretical framework to jointly estimate the operational topology and statistics of injections in radial distribution grids under limited availability of nodal voltage measurements. In particular, we show that our proposed algorithms are able to provably learn the exact grid topology and injection statistics at all unobserved nodes as long as they are not adjacent. The algorithm design is based on novel ordered trends in voltage magnitude fluctuations at node groups, that are independently of interest for radial physical flow networks. The complexity of the designed algorithms is theoretically analyzed and their performance is validated using both linearized and nonlinear ac power flow samples in test distribution grids.

97 MATHEMATICS AND COMPUTING↗

Magnetically tuned metal-insulator transition in LaAlO 3 /SrTiO 3 nanowire arrays

A wide family of two-dimensional (2D) systems, including stripe-phase superconductors, sliding Luttinger liquids, and anisotropic 2D materials, can be modeled by an array of coupled one-dimensional (1D) electron channels or nanowire arrays. Here we report experiments in arrays of conducting nanowires with gate and field tunable interwire coupling, that are programmed at the LaAlO 3 /SrTiO 3 interface. We find a magnetically tuned metal-to-insulator transition in which the transverse resistance of the nanowire array increases by up to four orders of magnitude, which can be further tuned with a gate voltage. To explain this behavior, we develop a minimal model of a coupled two-wire system where a Wenzel-Kramers-Brillouin-based approach is used to estimate the transverse tunneling conductance. We demonstrate the existence of distinct conductance features and highlight the crucial role played by the field dependence of the interwire potential barrier on transport properties. Since our model makes minimal assumptions, we expect our predictions to hold for a wide class of coupled 1D systems. The nanowire arrays can serve as model systems to understand the origin of exotic behavior in correlated materials via analog quantum simulation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Critical Clearing Time for Droop-Controlled Grid-Forming Inverters With Circular Current Limiting and Virtual Impedance Current Limiting

The critical clearing time is a crucial parameter for assessing the large-signal stability of grid-forming (GFM) inverters. Variations in current limiters can significantly impact an inverter's transient behavior during large disturbances. Here, this letter introduces a method based on the power-angle relationship to evaluate the fault recovery of a droop-controlled GFM inverter under a three-phase bolted fault scenario, considering both the circular current limiter and the virtual impedance method. High-fidelity simulations validate the accuracy of the proposed formulas in estimating the critical clearing time of the GFM inverter.

42 ENGINEERING↗

Aircraft electric field measurements: Calibration and ambient field retrieval

An aircraft locally distorts the ambient thundercloud electric field. In order to determine the field in the absence of the aircraft, an aircraft calibration is required. In this work a matrix inversion method is introduced for calibrating an aircraft equipped with four or more electric field sensors and a high-voltage corona point that is capable of charging the aircraft. An analytic, closed form solution for the estimate of a (3 x 3) aircraft calibration matrix is derived, and an absolute calibration experiment is used to improve the relative magnitudes of the elements of this matrix. To demonstrate the calibration procedure, we analyze actual calibration date derived from a Lear jet 28/29 that was equipped with five shutter-type field mill sensors (each with sensitivities of better than 1 V/m) located on the top, bottom, port, starboard, and aft positions. As a test of the calibration method, we analyze computer-simulated calibration data (derived from known aircraft and ambient fields) and explicitly determine the errors involved in deriving the variety of calibration matrices. We extend our formalism to arrive at an analytic solution for the ambient field, and again carry all errors explicitly.

Koshak, William J.↗

Perturbation-Based Diagnosis of False Data Injection Attack Using Distributed Energy Resources

Modern smart grid relies on various sensor measurements for its operational control. In a successful false data injection attack, the attacker manipulates the measurements from the grid sensors such that undetected errors are introduced into the estimates of the system parameters leading to catastrophic situations. This paper proposes a novel perturbation based false data injection attack detection mechanism that utilizes inverter based distributed energy resources (DERs) to create low magnitude perturbation signal in the distribution system voltage that is inconsequential to the normal grid operation. Two voltage sensitivity analysis based algorithms are designed to identify the optimal set of DERs that can create the voltage perturbation signal of desired magnitude. An analytical method of voltage sensitivity analysis is used to compute the magnitude of voltage perturbation signal at each node in a computationally efficient manner. Then, a detection mechanism is developed that checks for the presence of the perturbation sequence in each sensor measurement. A sensor measurement is deemed authentic if the voltage perturbation signal is present in the data. In case of sensor malfunction or cyber-attack, the perturbation signal will not be present in the measurement data. Performance of the proposed attack detection mechanism is validated via simulation of the IEEE 69 bus test system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Power Dependence of the Electron Mobility Profile in a Hall Thruster

The electron mobility profile is estimated in a 4.5 kW commercial Hall thruster as a function of discharge power. Internal measurements of plasma potential and electron temperature are made in the thruster channel with a high-speed translating probe. These measurements are presented for a range of throttling conditions from 150 - 400 V and 0.6 - 4.5 kW. The fluid-based solver, Hall2De, is used in conjunction with these internal plasma parameters to estimate the anomalous collision frequency profile at fixed voltage, 300 V, and three power levels. It is found that the anomalous collision frequency profile does not change significantly upstream of the location of the magnetic field peak but that the extent and magnitude of the anomalous collision frequency downstream of the magnetic peak does change with thruster power. These results are discussed in the context of developing phenomenological models for how the collision frequency profile depends on thruster operating conditions.

Jorns, Benjamin A.↗

Observation of Electromagnetic Transients in a Nb3Sn 4-layer Dipole Mirror Magnet

During testing of the Stress Managed Cosine-Theta dipole mirror magnet SMCTM1, magnet quenches were observed following large voltage spikes in the half-coil voltage taps which preceded normal quench initiation. Following some recent work at CERN measuring power current converter transients in relation to flux jumps, an additional differential current probe was added to the magnet instrumentation. Measurements of this probe, as well as the half coil voltage taps show a fast and substantial current change preceding the quench, hinting at coil motion. A simple model based on relative shift of the inner and outer layer coils was developed which suggests the magnitude of coil shift events is on the estimated relative coil shift from the magnet constraint conditions. The behavior is shown to be reversible and characteristic of stick-slip.

Krave, Steven [Fermilab] (ORCID:0000000217521457)↗

Chromium Diffusion Doping on ZnSe Crystals

Chromium doped zinc selenide crystal have recently been demonstrated to be a promising material for near-IR room temperature tunable lasers which have an emission range of 2-3 micrometers. In this study a new diffusion doping process has been developed for incorporation of Cr(+2) ion into ZnSe wafers. This process has been successfully performed under isothermal conditions, at temperatures above 800 C. Concentrations in excess of 10(exp 19) Cr(+2) ions/cu cm, an order of magnitude larger than previously reported in melt grown ZnSe material, have been obtained by diffusion doping, as estimated from optical absorption measurements. The diffusivity was estimated to be about 10(exp -8) sq cm/sec using a thin film diffusion model. Resistivity was derived from current-voltage measurements and in the range of 10(exp 13) and 10(exp 16) omega-cm. The emission spectra and temperature dependent lifetime data will also be presented and discussed.

Journigan, Troy D.↗

A slope reversal video processor having amplitude and pulse width discrimination.

A timing discriminator whose output is relatively insensitive to input pulse width and amplitude is described. The video-handling technique is known as slope reversal processing and is based on tapped delay line estimation methods. The concept, design, breadboard construction, and preliminary laboratory test results are reviewed. The processor system features (1) a peak input voltage dynamic range of 80x starting at 100 microvolts; (2) a four stage preamplifier/line-driver having a voltage gain of 2400x; (3) a tapped delay-line estimator implemented for slope reversal triggering by differential comparison; (4) a nominal plus or minus 2.5 nsec shift of the output trigger leading edge over the entire input voltage range, (5) up to 7 dB discrimination against pulse widths less than 35 nsec; and (6) up to one order of magnitude reduction in the false alarm rate compared to a constant fraction system.

Hoge, F. E.↗

Results from an international interlaboratory study on light‐ and elevated temperature‐induced degradation in solar modules

Abstract This paper reports the results of an international interlaboratory comparison study on light‐ and elevated temperature‐induced degradation (LETID) on crystalline silicon photovoltaic (PV) modules. A large global network of PV module manufacturers and PV testing laboratories collaborated to design a protocol for LETID detection and screen a large and diverse set of prototype modules for LETID. Results across labs indicate the reproducibility of LETID testing is likely within ±1% of maximum power (P MP ). In intentionally engineered LETID‐sensitive modules, mean degradation after the prescribed detection stress is roughly 6% P MP . In other module types the LETID sensitivity is smaller, and in some we observe essentially negligible degradation attributable to LETID. In LETID‐sensitive modules, both open‐circuit voltage (V OC ) and short‐circuit current (I SC ) degrade by a roughly similar magnitude. We observe, as do previous studies, that LETID affects each cell in a module differently. An investigation of the potential mismatch losses caused by nonuniform LETID degradation found that mismatch loss is insignificant compared to the estimated loss of cell I SC , which drives loss of module I SC . Overall, this work has helped inform the creation of a forthcoming standard technical specification for LETID testing of PV modules, IEC TS 63342 ED1, and should aid in the interpretation of results from that and other LETID tests.

14 SOLAR ENERGY↗

Duration test of an annular colloid thruster.

An annular colloid thruster was continuously operated for 1023 hours. Performance was stable with no sparking and negligible drain currents observed. An average thrust of 25.1 micropounds and an average specific impulse of 1160 seconds were obtained at an accelerating voltage of 15 k he thruster exhaust beam was continuously neutralized using electrons and electrostatic vectoring was demonstrated periodically. The only clear trend with time was an increase in specific impulse during the last third of the test period. From these results the thruster lifetime was estimated to be over an order of magnitude greater than the test duration.

Perel, J.↗

Results From Mars Show Electrostatic Charging of the Mars Pathfinder Sojourner Rover

Indirect evidence (dust accumulation) has been obtained indicating that the Mars Pathfinder rover, Sojourner, experienced electrostatic charging on Mars. Lander camera images of the Sojourner rover provide distinctive evidence of dust accumulation on rover wheels during traverses, turns, and crabbing maneuvers. The sol 22 (22nd Martian "day" after Pathfinder landed) end-of-day image clearly shows fine red dust concentrated around the wheel edges with additional accumulation in the wheel hubs. A sol 41 image of the rover near the rock "Wedge" (see the next image) shows a more uniform coating of dust on the wheel drive surfaces with accumulation in the hubs similar to that in the previous image. In the sol 41 image, note particularly the loss of black-white contrast on the Wheel Abrasion Experiment strips (center wheel). This loss of contrast was also seen when dust accumulated on test wheels in the laboratory. We believe that this accumulation occurred because the Martian surface dust consists of clay-sized particles, similar to those detected by Viking, which have become electrically charged. By adhering to the wheels, the charged dust carries a net nonzero charge to the rover, raising its electrical potential relative to its surroundings. Similar charging behavior was routinely observed in an experimental facility at the NASA Lewis Research Center, where a Sojourner wheel was driven in a simulated Martian surface environment. There, as the wheel moved and accumulated dust (see the following image), electrical potentials in excess of 100 V (relative to the chamber ground) were detected by a capacitively coupled electrostatic probe located 4 mm from the wheel surface. The measured wheel capacitance was approximately 80 picofarads (pF), and the calculated charge, 8 x 10(exp -9) coulombs (C). Voltage differences of 100 V and greater are believed sufficient to produce Paschen electrical discharge in the Martian atmosphere. With an accumulated net charge of 8 x 10(exp -9) C, and average arc time of 1 msec, arcs can also occur with estimated arc currents approaching 10 milliamperes (mA). Discharges of this magnitude could interfere with the operation of sensitive electrical or electronic elements and logic circuits. Sojourner rover wheel tested in laboratory before launch to Mars. Before launch, we believed that the dust would become triboelectrically charged as it was moved about and compacted by the rover wheels. In all cases observed in the laboratory, the test wheel charged positively, and the wheel tracks charged negatively. Dust samples removed from the laboratory wheel averaged a few ones to tens of micrometers in size (clay size). Coarser grains were left behind in the wheel track. On Mars, grain size estimates of 2 to 10 mm were derived for the Martian surface materials from the Viking Gas Exchange Experiment. These size estimates approximately match the laboratory samples. Our tentative conclusion for the Sojourner observations is that fine clay-sized particles acquired an electrostatic charge during rover traverses and adhered to the rover wheels, carrying electrical charge to the rover. Since the Sojourner rover carried no instruments to measure this mission's onboard electrical charge, confirmatory measurements from future rover missions on Mars are desirable so that the physical and electrical properties of the Martian surface dust can be characterized. Sojourner was protected by discharge points, and Faraday cages were placed around sensitive electronics. But larger systems than Sojourner are being contemplated for missions to the Martian surface in the foreseeable future. The design of such systems will require a detailed knowledge of how they will interact with their environment. Validated environmental interaction models and guidelines for the Martian surface must be developed so that design engineers can test new ideas prior to cutting hardware. These models and guidelines cannot be validated without actual flighata. Electrical charging of vehicles and, one day, astronauts moving across the Martian surface may have moderate to severe consequences if large potential differences develop. The observations from Sojourner point to just such a possibility. It is desirable to quantify these results. The various lander/rover missions being planned for the upcoming decade provide the means for doing so. They should, therefore, carry instruments that will not only measure vehicle charging but characterize all the natural and induced electrical phenomena occurring in the environment and assess their impact on future missions.

Kolecki, Joseph C.↗

Volume and Mass Estimation of Three-Phase High Power Transformers for Space Applications

Spacecraft historically have had sub-1kW(sub e), electrical requirements for GN&C, science, and communications: Galileo at 600W(sub e), and Cassini at 900W(sub e), for example. Because most missions have had the same order of magnitude power requirements, the Power Distribution Systems (PDS) use existing, space-qualified technology and are DC. As science payload and mission duration requirements increase, however, the required electrical power increases. Subsequently, this requires a change from a passive energy conversion (solar arrays and batteries) to dynamic (alternator, solar dynamic, etc.), because dynamic conversion has higher thermal and conversion efficiencies, has higher power densities, and scales more readily to higher power levels. Furthermore, increased power requirements and physical distribution lengths are best served with high-voltage, multi-phase AC to maintain distribution efficiency and minimize voltage drops. The generated AC-voltage must be stepped-up (or down) to interface with various subsystems or electrical hardware. Part of the trade-space design for AC distribution systems is volume and mass estimation of high-power transformers. The volume and mass are functions of the power rating, operating frequency, the ambient and allowable temperature rise, the types and amount of heat transfer available, the core material and shape, the required flux density in a core, the maximum current density, etc. McLyman has tabulated the performance of a number of transformers cores and derived a "cookbook" methodology to determine the volume of transformers, whereas Schawrze had derived an empirical method to estimate the mass of single-phase transformers. Based on the work of McLyman and Schwarze, it is the intent herein to derive an empirical solution to the volume and mass estimation of three-phase, laminated EI-core power transformers, having radiated and conducted heat transfer mechanisms available. Estimation of the mounting hardware, connectors, etc. is not included.

Kimnach, Greg L.↗

A quick accurate model of nozzle backflow

Backflow from nozzles is a major source of contamination on spacecraft. If the craft contains any exposed high voltages, the neutral density produced by the nozzles in the vicinity of the craft needs to be known in order to assess the possibility of Paschen breakdown or the probability of sheath ionization around a region of the craft that collects electrons for the plasma. A model for backflow has been developed for incorporation into the Environment-Power System Analysis Tool (EPSAT) which quickly estimates both the magnitude of the backflow and the species makeup of the flow. By combining the backflow model with the Simons (1972) model for continuum flow it is possible to quickly estimate the density of each species from a nozzle at any position in space. The model requires only a few physical parameters of the nozzle and the gas as inputs and is therefore ideal for engineering applications.

Kuharski, R. A.↗

Assessments of Hollow Cathode Wear in the Xenon Ion Propulsion System (XIPs(c)) by Numerical Analyses and Wear Tests

The standard approach presently followed by NASA to qualify electric propulsion for the required mission throughput has been based largely on life tests, which can be costly and time consuming. Revised electric propulsion lifequalification approaches are being formulated that combine analytical and/or computational methods with (shorter-duration) wear tests. As a model case, a wear test is being performed at JPL to assess the lifetime of the discharge hollow cathode in the Xenon Ion Propulsion System (XIPS(c)), a 25-cm ion engine developed by L-3 Communications Electron Technologies, Inc. for commercial applications. Wear and plasma data accumulated throughout this life-assessment program are being used to validate the existing 2-D hollow cathode code OrCa2D. We find that the OrCa2D steady-state solution predicts very well the time-averaged plasma data and the keeper voltage after 5500 hrs of operation in high-power mode. When the wave motion that occurs naturally in these devices is accounted for, based on an estimate of the maximum wave amplitude, the molybdenum-keeper erosion profile observed in the XIPS(c) discharge cathode is also reproduced within a factor of two of the observation. When the same model is applied to predict the erosion of a tantalum keeper we find that erosion is reduced by more than two orders of magnitude compared to the molybdenum keeper due the significantly lower sputtering yield of tantalum. A tantalum keeper would therefore allow keeper lifetimes that greatly exceed the present requirements for deep-space robotic missions considered by NASA. Moreover, such large reduction of the erosion renders the largest uncertainties in the models, which are associated with the wave amplitude estimates and the electron transport model, negligible.

plasma simulations↗