Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “voltage estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Predictive and Cooperative Voltage Control with Probabilistic Load and Solar Generation Forecasting

This paper proposes predictive cooperative voltage control method in a power system with high penetration of photovoltaic (PV) units. Cooperative distributed control of the reactive power output of PV inverters is coordinated with operation of voltage regulators (VRs) to maintain system voltages within an appropriate bandwidth. Probabilistic forecasting of the solar power generation and the loads is applied to estimate voltage changes which, in turn, are used to set the VR tap positions for preventing large voltage fluctuations with the lowest risk considering the voltage distribution estimation. The fine tuning of voltage adjustment is achieved by cooperative control of PV inverters to maintain a uniform voltage profile across the system. The proposed method is tested on the modified IEEE 123-node test feeder with high PV penetration using real insolation data and with constant loads replaced by several different load profiles. Simulation results demonstrate the effectiveness of the coordinated approach for voltage control with cooperative PV and predictive VR controls taking into account probabilistic load and solar power forecasts.

Cooperative Control↗

PNNL DSSE Docker Image

This is the docker image for Pacific Northwest National Laboratory's DSSE (distribution system state estimator) used for the demo of OEDI-SI platform. To support the operation of modern distribution systems, operators require real-time visibility into system states. Due to a lack of measurements and unbalanced operation, the state estimation in distribution systems is challenging. This submission is related to an OEDI-SI use case which demonstrates the application of an extended Kalman filter-based state estimator on an IEEE-123 bus system. The state estimator uses the measurements to generate voltage estimates for the system.

Array↗

Matrix Completion for Improved Observability in Low-Voltage Distribution Grids

This paper considers the problem of recovering missing entries in a partially observed matrix from relatively few measurements (i.e., the so-called matrix completion problem) with the aim of increasing the presently limited observability of low-voltage distribution grids. To this end, the partially observed matrix is formed using scarce voltage magnitude measurements while accounting for their spatial information. Voltage readings are assumed to be collected from distribution utility sensors and/or geographically-distributed cable television network sensors located in immediate proximity to distribution grid nodes. A matrix completion approach built on the parameter-less singular value shrinkage technique is used to estimate voltage magnitudes at otherwise non-observable low-voltage nodes using a small number of single- or multiple-snapshot data. The effectiveness of the proposed approach is demonstrated using a U.S.-style distribution test system from the synthetic SMART- DS data set under very low- to moderate-observability conditions.

low-rank matrix completion↗

Time-domain simulation of the crab cavity/beam interaction

The Electron-Ion Collider (EIC) will employ crab cavities to maximize luminosity. A time-domain simulation is developed to study the interaction between the particle beam and the crab cavities in the EIC, including the Low-Level RF (LLRF) feedback loops. The simulation is validated through power and induced voltage estimates. We then use the simulation tool to study the beam loading effects on the crabbing voltage and thus on the beam transverse position and tilt. We also study the crabbing voltage regulation and transmitter power transients as a function of the LLRF design.

43 PARTICLE ACCELERATORS↗

Enhancement of Distribution System State Estimation Using Pruned Physics-Aware Neural Networks

Realizing complete observability in the three-phase distribution system remains a challenge that hinders the implementation of classic state estimation algorithms. In this paper, a new method, called the pruned physics-aware neural network (P2N2), is developed to improve the voltage estimation accuracy in the distribution system. The method relies on the physical grid topology, which is used to design the connections between different hidden layers of a neural network model. To verify the proposed method, a numerical simulation based on one- year smart meter data of load consumptions for three-phase power flow is developed to generate the measurement and voltage state data. The IEEE 123-node system is selected as the test network to benchmark the proposed algorithm against the classic weighted least squares (WLS). Numerical results show that P2N2 outperforms WLS in terms of data redundancy and estimation accuracy.

distribution system state estimation↗

Enhancement of Distribution System State Estimation Using Pruned Physics-Aware Neural Networks: Preprint

Realizing complete observability in the three-phase distribution system remains a challenge that hinders the implementation of classical state estimation algorithms. In this paper, a new method so-called pruned physics-aware neural network (P2N2) is developed to improve the voltage estimation accuracy in the distribution system. The method relies on the physical grid topology, which is used to design the connections between different hidden layers of a neural network model. To verify the proposed method, a numerical simulation based on one-year smart meter data of load consumptions for threephase power flow is developed to generate the measurement and voltage state data. The IEEE 123 node system is selected as the test network to benchmark the proposed algorithm against the classical weighted least squares (WLS). Numerical results show that P2N2 outperforms WLS, in terms of data redundancy and estimation accuracy.

distribution systems state estimation↗

Data-Efficient Strategies for Probabilistic Voltage Envelopes under Network Contingencies

This work presents an efficient data-driven method to construct probabilistic voltage envelopes (PVE) using power flow learning in grids with network contingencies. First, a network-aware Gaussian process (GP) termed Vertex-Degree Kernel (VDK-GP), developed in prior work, is used to estimate voltage–power functions for a few network configurations. The paper introduces a novel multi-task vertex degree kernel (MT-VDK) that amalgamates the learned VDK-GPs to determine power flows for unseen networks, with a significant reduction in the computational complexity and hyperparameter requirements compared to alternate approaches. Simulations on the IEEE 30-Bus network demonstrate the retention and transfer of power flow knowledge in both N-1 and N-2 contingency scenarios. The MT-VDK-GP approach achieves over 50 % reduction in mean prediction error for novel N-1 contingency network configurations in low training data regimes (50–250 samples) over VDK-GP. Additionally, MT-VDK-GP outperforms a hyper-parameter based transfer learning approach in over 75 % of N-2 contingency network structures, even without historical N-2 outage data. Furthermore, the proposed method demonstrates the ability to achieve PVEs using sixteen times fewer power flow solutions compared to Monte-Carlo sampling-based methods.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Matrix Completion Using Alternating Minimization for Distribution System State Estimation

This paper examines the problem of state estimation in power distribution systems under low-observability conditions. The recently proposed constrained matrix completion method which combines the standard matrix completion method and power flow constraints has been shown to be effective in estimating voltage phasors under low-observability conditions using single-snapshot information. However, the method requires solving a semidefinite programming (SDP) problem, which becomes computationally infeasible for large systems and if multiple-snapshot (time-series) information is used. This paper proposes an efficient algorithm to solve the constrained matrix completion problem with time-series data. This algorithm is based on reformulating the matrix completion problem as a bilinear (non-convex) optimization problem, and applying the alternating minimization algorithm to solve this problem. This paper proves the summable convergence of the proposed algorithm, and demonstrates its efficacy and scalability via IEEE 123-bus system and a real utility feeder system. This paper also explores the value of adding more data from the history in terms of computation time and estimation accuracy.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Matrix Completion Using Alternating Minimization for Distribution System State Estimation: Preprint

This paper examines the problem of state estimation in power distribution systems under low-observability conditions. The recently proposed constrained matrix completion method which combines the standard matrix completion method and power flow constraints has been shown to be effective in estimating voltage phasors under low-observability conditions using single-snapshot information. However, the method requires solving a semidefinite programming (SDP) problem, which becomes computationally infeasible for large systems and if multiple-snapshot (time-series) information is used. This paper proposes an efficient algorithm to solve the constrained matrix completion problem with time-series data. This algorithm is based on reformulating the matrix completion problem as a bilinear (non-convex) optimization problem, and applying the alternating minimization algorithm to solve this problem. This paper proves the summable convergence of the proposed algorithm, and demonstrates its efficacy and scalability via IEEE 123-bus system and a real utility feeder system. This paper also explores the value of adding more data from the history in terms of computation time and estimation accuracy.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Towards Improved Decision Making for the Smarter Grid: Geomagnetic Disturbance Implicit Modeling Uncertainty Quantification

Geomagnetic disturbances can greatly disrupt the power grid operation. This is caused by low-frequency changes in the earth’s magnetic field, which upon interaction with the deep earth conductivity induces a changing electric field at the earth’s surface. This in turn induces quasi-direct currents which have the potential to cause protective devices to operate, widespread damage to high-voltage transformers, or voltage collapse due to induced reactive power losses. While these impacts have been known since the 1940s, only recently have standards for GMD response been implemented. Because these standards are heavily based on models, it is important to understand when it is appropriate to make certain modeling assumptions. In this work, implicit modeling uncertainty is quantified for the purpose of enhanced decision making for disturbance impact mitigation. Considering electromagnetic models, modeling assumptions of non-uniform grounding, imbalanced operation, transformer saturation, and geomagnetically induced currents, voltage estimation values are analyzed. Statistical characteristics of modeling uncertainty are obtained by analysis of synthetically generated data. Results statistically characterize geomagnetic disturbances modeling uncertainty, providing an important tool for impact mitigation.

grid analysis↗

Online Monitoring Applications Enabled by Phasor Measurement Units: Technical Assistance to the Power Sectors of Southeast Asia

In this report, an overview of several online applications enabled by PMU measurements is provided. Besides a brief technical background for each application, the report also discusses control room displays and alarming methodologies used by North American organizations, and applicable standards set by the North American Electric Reliability Corporation (NERC). The five applications discussed herein are inertia monitoring, linear state estimation, voltage stability monitoring, small-signal stability monitoring, and forced oscillation monitoring.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Single-Phase to Split-Phase Inverters with Advanced Grid Support Functions for Grid-Interactive Applications

This work presents a cost-effective single-phase to split-phase inverter with a reduced switch count, achieving grid interactive performance while maintaining operational efficiency. The proposed system integrates an Andronov-Hopf oscillator based secondary controller, which inherently embeds a nonlinear resistive droop architecture, ensuring rapid dynamic response. A Lyapunov energy function-based primary control enhances transient stability and regulation, while an internal model-based point of common coupling voltage estimation enables cost optimization without additional sensors. Equipped with advanced grid support functionalities, the inverter facilitates seamless distribution system operation with enhanced robustness. The effectiveness of the proposed architecture and control strategy is validated through MATLAB/Simulink and PLECS simulations, demonstrating its feasibility for high-performance grid-supportive applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A sensitive image intensifier which uses inert gas

High gain optical image intensifier utilizes inert gas cavity with copper electrodes to form electron avalanches without excessive pulse voltages. Estimated optical gain for device is two times 10 to the power of seven.

Kerns, Q. A.↗

Neumann Series Based Voltage Sensitivity Analysis for Three Phase Distribution System

In this letter, a simplified voltage sensitivity analysis technique that can provide accurate estimates of voltage change across the network for a given change in bus power injections in a three-phase unbalanced distribution network is proposed. This technique is derived from the first-order approximation of the Neumann series, which allows maintaining the accuracy of the solution while the computational effort is reduced. Here, the proposed technique is tested on a 559-bus unbalanced distribution system with multiple distributed generation resources. The results show that the average error in the voltage estimates with the proposed method is not more than 0.3% with the execution time of similar order relative to the state-of-the-art sensitivity analysis methods.

42 ENGINEERING↗

Gas Composition Sensing Using Carbon Nanotube Arrays

This innovation is a lightweight, small sensor for inert gases that consumes a relatively small amount of power and provides measurements that are as accurate as conventional approaches. The sensing approach is based on generating an electrical discharge and measuring the specific gas breakdown voltage associated with each gas present in a sample. An array of carbon nanotubes (CNTs) in a substrate is connected to a variable-pulse voltage source. The CNT tips are spaced appropriately from the second electrode maintained at a constant voltage. A sequence of voltage pulses is applied and a pulse discharge breakdown threshold voltage is estimated for one or more gas components, from an analysis of the current-voltage characteristics. Each estimated pulse discharge breakdown threshold voltage is compared with known threshold voltages for candidate gas components to estimate whether at least one candidate gas component is present in the gas. The procedure can be repeated at higher pulse voltages to estimate a pulse discharge breakdown threshold voltage for a second component present in the gas. The CNTs in the gas sensor have a sharp (low radius of curvature) tip; they are preferably multi-wall carbon nanotubes (MWCNTs) or carbon nanofibers (CNFs), to generate high-strength electrical fields adjacent to the tips for breakdown of the gas components with lower voltage application and generation of high current. The sensor system can provide a high-sensitivity, low-power-consumption tool that is very specific for identification of one or more gas components. The sensor can be multiplexed to measure current from multiple CNT arrays for simultaneous detection of several gas components.

Li, Jing↗

Local Power-Voltage Sensitivity and Thevenin Impedance Estimation from Phasor Measurements

This paper describes how to use voltage phasor measurements to produce a sensitivity matrix that describes how real and reactive power injections at a node on a distribution network affect the local voltage magnitude and angle. Rather than estimating the sensitivity directly, the voltage phasor measurements and power commands/measurements are used to estimate the unbalanced, three-phase Thevenin impedance. The Thevenin impedance estimation is conducted using recursive least squares on temporal difference measurements. The Thevenin impedance and voltage phasor measurement are then used to build the local power-voltage sensitivity matrix with the closed form expression for the Jacobian of the power flow manifold. Hardware-in-the-loop simulations with phasor measurement units providing real phasor measurements are used to evaluate the recursive temporal difference Thevenin impedance estimation and Thevenin-based power-voltage sensitivity methods.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Gas composition sensing using carbon nanotube arrays

A method and system for estimating one, two or more unknown components in a gas. A first array of spaced apart carbon nanotubes (''CNTs'') is connected to a variable pulse voltage source at a first end of at least one of the CNTs. A second end of the at least one CNT is provided with a relatively sharp tip and is located at a distance within a selected range of a constant voltage plate. A sequence of voltage pulses {V(t.sub.n)}.sub.n at times t=t.sub.n (n=1, . . . , N1; N1.gtoreq.3) is applied to the at least one CNT, and a pulse discharge breakdown threshold voltage is estimated for one or more gas components, from an analysis of a curve I(t.sub.n) for current or a curve e(t.sub.n) for electric charge transported from the at least one CNT to the constant voltage plate. Each estimated pulse discharge breakdown threshold voltage is compared with known threshold voltages for candidate gas components to estimate whether at least one candidate gas component is present in the gas. The procedure can be repeated at higher pulse voltages to estimate a pulse discharge breakdown threshold voltage for a second component present in the gas.

Li, Jing↗

Robust Medium-Voltage Distribution System State Estimation using Multi-Source Data

Due to the lack of sufficient online measurements for distribution system observability, pseudo-measurements from short-term load or distributed renewable energy resources (DERs) forecasting are used. However, the accuracy of them is low and thus significantly limits the performance of distribution system state estimation (DSSE). In this paper, a robust DSSE that integrates multi-source measurement data is proposed. Specifically, the historical low-voltage (LV) side smart meters are used to forecast load and DERs injections via the support vector machine (SVM) with optimally tuned parameters. By contrast, the online smart meters at LV side are utilized to derive equivalent power injections at the MV/LV transformers, yielding more accurate pseudo-measurements compared to the forecasted injections. Furthermore, to deal with bad data caused by communication loss, instrumental errors and cyber attacks, robust DSSE that relies on generalized maximum-likelihood (GM)-estimation criterion is developed. The projection statistics are developed to adjust the weights of each measurement, leading to better balance between pseudo- and real-time measurements. Numerical results conducted on modified IEEE 33-bus system with DG integration demonstrate the effectiveness and robustness of the proposed method.

distribution system state estimation↗