Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ventilation rate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A Time-Varying Model for Predicting Formaldehyde Emission Rates in Homes

Recent studies have succeeded in relating emissions of various volatile organic compounds to material mass diffusion transfer using detailed empirical characteristics of each of the individual emitting materials. While significant, the resulting models are often scenario specific and/or require a host of individual component parameters to estimate emission rates. This study developed an approach to estimate aggregated emissions rates based on a wide number of field measurements. We used a multi-parameter regression model based on previous mass transfer models to predict formaldehyde emission rate for a whole dwelling using field-measured, time-resolved formaldehyde concentrations, air exchange rates, and indoor environmental parameters in 63 California single-family houses built between 2011 and 2017. The resulting model provides time-varying formaldehyde emission rates, normalized by floor area, for each study home, assuming a well-mixed mass balance transport model of the home, and a well-mixed layer transport model of indoor surfaces. The surface layer model asserts an equilibrium concentration within the surface layer of the emitted materials that is a function of temperature and RH; the dwelling ventilation rate serves as a surrogate for indoor concentration. We also developed a more generic emission model that is suitable for broad prediction of emission for a population of buildings. This model is also based on measurements aggregated from 27 homes from the same study. We showed that errors in predicting household formaldehyde concentrations using this approach were substantially less than those using a traditional constant emission rate model, despite requiring less unique building information.

54 ENVIRONMENTAL SCIENCES↗

A physiologically based pharmacokinetic (PBPK) model to align dosimetry of the isobutyl metabolic series in rats and humans

Here, we developed a physiologically based pharmacokinetic (PBPK) model in rats and humans for the isobutyl metabolic series including isobutyl acetate, isobutanol, isobutyraldehyde, and isobutyric acid. Chemical manufactures routinely use these compounds as solvents, for chemical synthesis, as potential biofuels, de-icing fluids, and additives for food and/or fragrance in consumer products. Human exposure to isobutyl compounds can occur through inhalation or oral routes. We previously developed a PBPK model for the propyl metabolic series and utilized it as a framework to create the isobutyl PBPK model due to the chemical similarities between the two series. To support model development, we measured in vitro metabolism of isobutyl acetate in rat and human blood and liver S9 fractions. Compared to rats, humans demonstrated faster isobutyl acetate hydrolysis in liver S9 fractions, while the hydrolysis rates in blood were similar between the two species. We used concentrations of isobutyl compounds measured in air and blood from rats exposed to isobutyl acetate and isobutanol as well as other published data to further parameterize the model. Following exposure to either isobutyl acetate or isobutanol, we observed isobutanol concentrations highest among the isobutyl compounds in the blood of rats. Overall, the model accurately predicts measured time course concentrations of isobutyl acetate, isobutanol, and isobutyric acid in available data in rats and humans. Sensitivity analyses identified alveolar ventilation rates, isobutyl metabolism rates, and cardiac output as the most sensitive parameters affecting concentrations of isobutyl compounds in blood. The isobutyl PBPK model enables comparisons of internal dose metrics across various isobutyl compound exposures and species and allows for calculation of equivalent external exposures that result in the same dose metric. Regulators can employ this PBPK model to predict and align internal dose metrics of isobutyl compounds for risk assessment purposes.

2-methyl-1-propanol↗

Lab Home Testing of Residential Isolation Space Control to Minimize Infectious Disease Transmission in Existing Single-Family Homes

Existing evidence strongly suggests that viral infectious diseases can be transmitted via an airborne route across distances in indoor environments. Accordingly, the risk of airborne transmission within homes should be managed. The public health emergency associated with SARS-CoV-2 makes controlling airborne transmission of respired viruses in indoor environments critical, especially in poorly ventilated indoor environments. The effectiveness of engineering interventions requiring minor efforts that create a negative-pressure isolation zone (IZ) for a contagious person has yet to be tested for existing residential homes. To mitigate the risk of airborne virus transmission and maximize health protection for the population in existing single-family homes, the relative effectiveness of several control strategies are investigated in this report. While very high-efficiency MERV filtration, high ventilation rates, and other controls can help be effective, most occupants are not likely to have the time or means for advanced measures found in hospitals. This project focused on testing relatively simple efforts that utilize existing or easy to acquire materials and simple processes.

30 DIRECT ENERGY CONVERSION↗

Lab Home Testing of Residential Isolation Space Control to Minimize Infectious Disease Transmission in Existing Single-Family Homes

Existing evidence strongly suggests that viral infectious diseases can be transmitted via an airborne route across distances in indoor environments. Accordingly, the risk of airborne transmission within homes should be managed. The public health emergency associated with SARS-CoV-2 makes controlling airborne transmission of respired viruses in indoor environments critical, especially in poorly ventilated indoor environments. The effectiveness of engineering interventions requiring minor efforts that create a negative-pressure isolation zone (IZ) for a contagious person has yet to be tested for existing residential homes. To mitigate the risk of airborne virus transmission and maximize health protection for the population in existing single-family homes, the relative effectiveness of several control strategies are investigated in this report. While very high-efficiency MERV filtration, high ventilation rates, and other controls can help be effective, most occupants are not likely to have the time or means for advanced measures found in hospitals. This project focused on testing relatively simple efforts that utilize existing or easy to acquire materials and simple processes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Review of Variables Impacting the Indoor Inhalation Radon Equilibrium Factor (FEQ)

With radon and its daughter products estimated as the second leading cause of lung cancer in the United States, it is imperative to understand their relative equilibrium inside commercial, community, and residential dwellings. The radon indoor inhalation fractional equilibrium factor (F eq ) quantifies the disequilibrium between radon and its progeny in indoor air, and recent advances have shown how air exchange rates (ACH) influence F eq . These numerically derived ACH-dependent F eq values are incorporated into the U.S. EPA's Radon Vapor Intrusion Screening Level (RVISL) calculator, which assists risk assessors in evaluating radon exposure. To advance the risk assessment science of actinon (Rn-219), thoron (Rn-220), and radon (Rn-222), the impact of variables such as indoor aerosol concentration and composition, outdoor air quality, household-specific characteristics, and environmental/meteorological conditions on the F eq must be examined. The primary objective of this research is to analyze these additional variables to determine the usefulness of incorporating such adjustment factors into the RVISL calculator and to identify areas of future research. Studies regarding the influence of these parameters are presented along with recommendations regarding the adjustment of the numerically derived F eq value. For example, elevated indoor aerosol concentrations, such as those originating from outdoor PM 2.5 or cigarette smoke, increase the abundance of accumulation- mode particles indoors, which in turn raises F eq values by facilitating the attachment of radon progeny to these aerosols. Smoking increases both the bronchial dose and F eq , while regions with high smog levels demonstrate the impact of regional air quality on F eq . In contrast, air cleaning systems and purifiers have been shown to reduce the F eq , suggesting that these systems could help mitigate radon exposure. Additionally, higher F eq values are typically observed during winter when ventilation rates are lower. This paper presents adjustment factors that may be applied to the RVISL F eq , emphasizing the need for further research to refine these variables and ensure accurate risk assessments in diverse environments. Applying these adjustment factors will minimize calculator over- and underestimations, providing a more accurate representation of the real-world risk associated with radon.

54 ENVIRONMENTAL SCIENCES↗

Ventilation in Residential Care Environments

The purpose of this study was to evaluate the effect of ventilation rate, directional airflow (e.g. pressure relationships) and airflow barriers on bioaerosol concentration and movement within assisted-living and residential care environments. Included within this report is a comprehensive literature review, field data collection test plan and, an evaluation of commercially available mitigation technologies related to the transmission of COVID-19 in LTC environments. Additionally, this report includes aerosol testing in an actual LTC facility using the test plan developed herein. Nearly 1.5 million people live in 16,000 nursing homes in the U.S. As of December 20, 2020 the Centers for Medicare and Medicaid Services (CMS) identified a total of 662,549 confirmed and suspected COVID-19 cases in these and other long-term care (LTC) facilities resulting in 92,373 deaths. At this time, COVID-19 cases in LTC facilities accounted for only 3% of the U.S. total of 21M confirmed cases yet nearly a third of the 350,000 total U.S. deaths. Preliminary studies have found little correlation between the quality of care and transmission of COVID-19 in these facilities, suggesting that even the best infection control practices may not be effective in containing the spread of this potentially airborne disease. As a result, many LTC facilities have implemented quarantine procedures and other measures to isolate infectious residents from the general population. Unfortunately, most LTC facilities were not designed for airborne infection control and guidance for retrofitting existing LTC spaces for airborne isolation is limited.

42 ENGINEERING↗

Indoor air quality in new and renovated low-income apartments with mechanical ventilation and natural gas cooking in California

This work presents pollutant concentrations and performance data for code-required mechanical ventilation equipment in 23 low-income apartments at 4 properties constructed or renovated 2013-2017. All apartments had natural gas cooking burners. Occupants pledged to not use windows for ventilation during the study but several did. Measured airflows of range hoods and bathroom exhaust fans were lower than product specifications. Only eight apartments operationally met all ventilation code requirements. Pollutants measured over one week in each apartment included time-resolved fine particulate matter (PM 2.5 ), nitrogen dioxide (NO 2 ), formaldehyde and carbon dioxide (CO 2 ) and time-integrated formaldehyde, NO 2 and nitrogen oxides (NO X ). Compared to a recent study of California houses with code-compliant ventilation, apartments were smaller, had fewer occupants, higher densities, and higher mechanical ventilation rates. Mean PM 2.5 , formaldehyde, NO 2 , and CO 2 were 7.7 µg/m 3 , 14.1 ppb, 18.8 ppb, and 741 ppm in apartments; these are 4% lower, 25% lower, 165% higher, and 18% higher compared to houses with similar cooking frequency. Four apartments had weekly PM 2.5 above the California annual outdoor standard of 12 µg/m 3 and also discrete days above the World Health Organization 24-h guideline of 25 µg/m 3 . Two apartments had weekly NO 2 above the California annual outdoor standard of 30 ppb.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Safety Codes and Standards Review and Gap Analysis for Applicability to Hydrogen Rail Refueling, Defueling, Maintenance, and Storage

Hydrogen-powered locomotives may present an alternative to diesel for achieving transportation-related decarbonization, energy security, and resilience goals. As an emerging technology, hydrogen locomotives may not have adequate representation in current safety codes and standards. NFPA 2 and other appropriate codes and standards were reviewed to identify technical gaps in the code for hydrogen rail defueling, refueling, maintenance, and storage. Several technical gaps pertaining to setback distances, allowable quantities, ventilation rates, and grounding have been identified. Fueling requirements can be informed by road vehicle standards but may need to be revised for larger quantity hydrogen locomotive systems. Since there are no hydrogen-specific locomotive design and safety standards, some aspects of diesel-based locomotive standards may apply. CGA G- 5.5 currently provides the most guidance on height, placement, orientation, and design of vent systems, while other standards emphasize the importance of shielding vent stacks and provide requirements for orientation of their discharge.

08 HYDROGEN↗

Control of thermal balance by a liquid circulating garment based on a mathematical representation of the human thermoregulatory system

Test data and a mathematical model of the human thermoregulatory system were used to investigate control of thermal balance by means of a liquid circulating garment (LCG). The test data were derived from five series of experiments in which environmental and metabolic conditions were varied parametrically as a function of several independent variables, including LCG flowrate, LCG inlet temperature, net environmental heat exchange, surrounding gas ventilation rate, ambient pressure, metabolic rate, and subjective/obligatory cooling control. The resultant data were used to relate skin temperature to LCG water temperature and flowrate, to assess a thermal comfort band, to demonstrate the relationship between metabolic rate and LCG heat dissipation, and so forth. The usefulness of the mathematical model as a tool for data interpretation and for generation of trends and relationships among the various physiological parameters was also investigated and verified.

Kuznetz, L. H.↗

Metabolic and cardiovascular adaptation, monkey. NASA SMD 3, project 76, experiment 44 conducted at NASA/JSC, 14-25 May 1977

The biomedical results from an experiment on a monkey subjected to space flight conditions are reported. A background history of the development and testing of an experiment system designed to permit measurement of physiological parameters in subhuman primates during continuous, comfortable, couch restraint for periods of up to 30 days is reviewed. Of major importance in the experimental design of the system was the use of a fiberglass pod, which could be sealed and subdivided into upper and lower parts, to monitor and control the physiological responses for various parts of the animal's body. The experiment was conducted within the Spacelab Simulator for a period of 11 days. Data recorded includes: Spacelab Simulator cabin temperature; ventilation rate; pod internal temperature; fraction percent oxygen; fraction percent carbon dioxide; oxygen consumption rate; carbon dioxide production rate; respiratory quotient; intrathoracic temperature; heart rate; mean aortic pressure; mean ventricular pressure; diurnal variation of parameters measured; comparison of mean preflight, flight, and postflight values of the parameters measured; and correlation matrix for the parameters measured.

Pace, N.↗

Evaluation of exercise-respiratory system modifications and preliminary respiratory-circulatory system integration scheme

The respiratory control system, functioning as an independent system, is presented with modifications of the exercise subroutine. These modifications illustrate an improved control of ventilation rates and arterial and compartmental gas tensions. A very elementary approach to describing the interactions of the respiratory and circulatory system is presented.

Gallagher, R. R.↗

Evaluation of exercise-respiratory system modifications and integration schemes for physiological systems

Exercise subroutine modifications are implemented in an exercise-respiratory system model yielding improvement of system response to exercise forcings. A more physiologically desirable respiratory ventilation rate in addition to an improved regulation of arterial gas tensions and cerebral blood flow is observed. A respiratory frequency expression is proposed which would be appropriate as an interfacing element of the respiratory-pulsatile cardiovascular system. Presentation of a circulatory-respiratory system integration scheme along with its computer program listing is given. The integrated system responds to exercise stimulation for both nonstressed and stressed physiological states. Other integration possibilities are discussed with respect to the respiratory, pulsatile cardiovascular, thermoregulatory, and the long-term circulatory systems.

Gallagher, R. R.↗

Reduced bleed air extraction for DC-10 cabin air conditioning

It is noted that a significant fuel savings can be achieved by reducing bleed air used for cabin air conditioning. Air in the cabin can be recirculated to maintain comfortable ventilation rates but the quality of the air tends to decrease due to entrainment of smoke and odors. Attention is given to a development system designed and fabricated under the NASA Engine Component Improvement Program to define the recirculation limit for the DC-10. It is shown that with the system, a wide range of bleed air reductions and recirculation rates is possible. A goal of 0.8% fuel savings has been achieved which results from a 50% reduction in bleed extraction from the engine.

Newman, W. H.↗

Space bio-technology in housing

Gas chromatography and mass spectrometry data obtained from monitoring atmospheric pollutants in Skylab spurred studies of indoor pollutants in terrestrial buildings. Subsequent studies of techniques for removing the pollutants from space habitats have led to building concepts which achieve the same purpose on earth. The Skylab data indicated that the synthesized organic materials used in many modern buildings, furnishings, personal clothing and aerosols add significant amounts of chemicals to the indoor atmosphere. Lowered circulation and ventilation rates to conserve energy have caused trapping of these substances in buildings. Studies of methods for space modules which will use plants and microbes to absorb airborne and wastewater pollutants have defined biotechnology designs which can be applied to remove pollutants from air and wastewater organically. Plant roots trap pollutants from wastewater and leaves readily absorb air pollutants, as well as improve the overall energy efficiency of buildings. Several designs which incorporate biotechnology to enhance both the aesthetics and efficiency of homes and office buildings are illustrated.

Wolverton, B. C.↗

Human Physiological Responses to Cycle Ergometer Leg Exercise During +Gz Acceleration

Spaceflight and bed-rest deconditioning decrease maximal oxygen uptake (aerobic power), strength, endurance capacity, and orthostatic tolerance. In addition to extensive use of muscular exercise conditioning as a countermeasure for the reduction in aerobic power (VO(sub 2max)), stimuli from some form of +Gz acceleration conditioning may be necessary to attenuate the orthostatic intolerance component of this deconditioning. Hypothesis: There will be no significant difference in the physiological responses (oxygen uptake, heart rate, ventilation, or respiratory exchange ratio) during supine exercise with moderate +Gz acceleration.

Chou, J. L.↗

Relationships Between the Planetary Boundary Layer Height and Surface Pollutants Derived from Lidar Observations over China: Regional Pattern and Influencing Factors

The frequent occurrence of severe air pollution episodes in China has been a great concern and thus the focus of intensive studies. Planetary boundary layer height (PBLH) is a key factor in the vertical mixing and dilution of near-surface pollutants. However, the relationship between PBLH and surface pollutants, especially particulate matter (PM) concentration across China, is not yet well understood. We investigate this issue at 1600 surface stations using PBLH derived from space-borne and ground-based lidar, and discuss the influence of topography and meteorological variables on the PBLH–PM relationship. Albeit the PBLH–PM correlations are roughly negative for most cases, their magnitude, significance, and even sign vary considerably with location, season, and meteorological conditions. Weak or even uncorrelated PBLH–PM relationships are found over clean regions (e.g., Pearl River Delta), whereas nonlinearly negative responses of PM to PBLH evolution are found over polluted regions (e.g., North China Plain). Relatively strong PBLH–PM interactions are found when the PBLH is shallow and PM concentration is high, which typically corresponds to wintertime cases. Correlations are much weaker over the highlands than the plains regions, which may be associated with lighter pollution loading at higher elevations and contributions from mountain breezes. The influence of horizontal transport on surface PM is considered as well, manifested as a negative correlation between surface PM and wind speed over the whole nation. Strong wind with clean upwind air plays a dominant role in removing pollutants, and leads to obscure PBLH–PM relationships. A ventilation rate is used to jointly consider horizontal and vertical dispersion, which has the largest impact on surface pollutant accumulation over the North China Plain. As such, this study contributes to improved understanding of aerosol–planetary boundary layer (PBL) interactions and thus our ability to forecast surface air pollution.

Su, Tianning↗

Harvesting the low-hanging fruit of high energy savings -- Virtual Occupancy using Wi-Fi Data

Approximately 20% of primary energy consumed in the U.S. is attributed to HVAC use. Ideally, HVAC operation would be driven by actual building occupancy, but lack of reliable occupancy information often results in the use of conservative static schedules. This disparity is even more pronounced in a college campus, where the function of each space differs by building (classrooms, offices, libraries) and the class schedules change frequently -- every semester, day of week, and hour. While several research papers propose the use of counts of the Wi-Fi connections (e.g., phones, computers) as a proxy for occupancy, few real-world implementations exist. This paper describes the development and deployment of an open-source Wi-Fi-to-Occupancy software library in 65 buildings of a college campus, and the planned integration with the building energy management and control system at the building scale. Over a year of Wi-Fi data was gathered into distinct academic periods, including fall and spring semester, academic breaks, and summer sessions. Patterns such as students moving between classrooms, closing laptops before exams, etc., can be visualized from the data. Approximating occupancy from Wi-Fi data presents challenges which we address in this project -- for example, identifying static devices, or estimating the ratio of devices per person. Utilizing real-time occupancy data to inform optimal HVAC schedules and ventilation rates creates the potential to identify and reduce energy waste. Other potential applications include forecasting occupancy, and using Wi-Fi data to predict peak demands. Finally, the paper discusses how to easily scale these tools to other buildings.

Pritoni, Marco↗

COVID-19 Exposure Assessment Tool (CEAT): Exposure quantification based on ventilation, infection prevalence, group characteristics, and behavior

The coronavirus disease 2019 (COVID-19) Exposure Assessment Tool (CEAT) allows users to compare respiratory relative risk to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) for various scenarios, providing understanding of how combinations of protective measures affect risk. CEAT incorporates mechanistic, stochastic, and epidemiological factors including the (i) emission rate of virus, (ii) viral aerosol degradation and removal, (iii) duration of activity/exposure, (iv) inhalation rates, (v) ventilation rates (indoors/outdoors), (vi) volume of indoor space, (vii) filtration, (viii) mask use and effectiveness, (ix) distance between people (taking into account both near-field and far-field effects of proximity), (x) group size, (xi) current infection rates by variant, (xii) prevalence of infection and immunity in the community, (xiii) vaccination rates, and (xiv) implementation of COVID-19 testing procedures. CEAT applied to published studies of COVID-19 transmission events demonstrates the model’s accuracy. We also show how health and safety professionals at NASA Ames Research Center used CEAT to manage potential risks posed by SARS-CoV-2 exposures.

60 APPLIED LIFE SCIENCES↗