Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “velocimetry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Photon Doppler velocimetry surface return study for common surface preparations

Photon Doppler velocimetry (PDV) is a ubiquitous diagnostic method in dynamic compression experiments. It typically requires the roughening of the test surface to ensure scattering of the probe light back into the PDV probe at non-normal angles of incidence. Although surface scattering plays an essential role in the quality of PDV data, surface scattering properties for common materials and preparations have not previously been studied with specific relevance to PDV. Here, we present detailed measurements of the bidirectional reflectance distribution function for four different surface preparations (Scotch-Brite hand and drill roughened, ball-rolled, and grit blasted) and four different materials (copper, aluminum, stainless steel, and tantalum). These measurements employ a conventional PDV probe and obtain a diffraction limited angular resolution with 10 pW accuracy and 2.6% repeatability. In addition to scattering data, we employ scattering theory and simulations to accurately emulate the measured data. We also present a straightforward method to derive the average scattering distribution from surface profilometry and observe several qualitative aspects of the scattering data that may help to optimize PDV signals.

42 ENGINEERING↗

Pacific Marine Energy Center Laser Doppler Velocimetry Commissioning

First commissioning data for the new laser doppler velocimetry (LDV) system that will be used at the Tyler Flume at the University of Washington. The LDV system can measure three components of velocity at a point. For this dataset the three components were operated in non-coincident mode and data were acquired at the center of the empty facility. Comparisons of freestream turbulence were made with a Vectrino slightly upstream of the LDV measurement location.

16 TIDAL AND WAVE POWER↗

Velocity Measurements in Channel Gas Flows in the Slip Regime by means of Molecular Tagging Velocimetry

Direct measurements of the slip velocity in rarefied gas flows produced by local thermodynamic non-equilibrium at the wall represent crucial information for the validation of existing theoretical and numerical models. In this work, molecular tagging velocimetry (MTV) by direct phosphorescence is applied to argon and helium flows at low pressures in a 1-mm deep channel. MTV has provided accurate measurements of the molecular displacement of the gas at average pressures of the order of 1 kPa. To the best of our knowledge, this work reports the very first flow visualizations of a gas in a confined domain and in the slip flow regime, with Knudsen numbers up to 0.014. MTV is cross-validated with mass flowrate measurements by the constant volume technique. The two diagnostic methods are applied simultaneously, and the measurements in terms of average velocity at the test section are in good agreement. Moreover, preliminary results of the slip velocity at the wall are computed from the MTV data by means of a reconstruction method

74 ATOMIC AND MOLECULAR PHYSICS↗

A microfluidic study of transient flow states in permeable media using fluorescent particle image velocimetry

Velocity fields in flow in permeable media are of great importance to many subsurface processes such as geologic storage of CO 2 , oil and gas extraction, and geothermal systems. Steady-state flow is characterized by velocity fields that do not change significantly over time. The flow field transitions to a new steady state once it experiences a disturbance such as a change in flow rate or in pressure gradient. This transition is often assumed to be instantaneous, which justifies the expression of constitutive relations as functions of instantaneous phase saturations. This work examines the evolution of velocity fields in a surrogate quasi-2D permeable medium using a microfluidic device, a microscopy system, and a high-speed camera. Tracer particles are injected into the medium along with DI water. The evolution of the velocity field is examined by tracing these particles in the captured images using the standard high-density particle image velocimetry algorithm founded on cross-correlation. The results suggest that the transition between steady states for an incompressible fluid takes a finite and non-negligible amount of time that is independent of the magnitude of the change in pressure gradient. The existence of transient states and the nature of the response during these states are readily interpreted by the principle of least action where flow gradually establishes an optimal configuration such that energy dissipation is 2 minimized. The findings provide evidence against the applicability of the assumption that flowing phases relax instantaneously to their steady states and, hence, against the accuracy of the classical multiphase extension of Darcy's law.

42 ENGINEERING↗

High-fidelity Experiments of Turbulent Buoyant Jets from Simultaneous Particle Image Velocimetry and Laser Induced Fluorescence

Accurate models of turbulent buoyant flows are essential for the design of nuclear reactors thermal hydraulics and passive safety systems. However, available models fail to fully capture the physics of turbulent mixing when buoyancy becomes predominant with respect to momentum. Therefore, high-fidelity experiments of well-controlled fundamental flows are needed to develop and validate more accurate models. We performed experiments of positive and negative turbulent buoyant jets, both in uniform and stratified environments, with the aim of understanding the thermal hydraulics of turbulent mixing with variable density and providing high-fidelity data for the development and validation of turbulence models. Non-intrusive, simultaneous Particle Image Velocimetry and Laser Induced Fluorescence measurements were carried out to acquire instantaneous velocity and concentration fields on a vertical section parallel to the axis of a jet in the self-similar region. The Refractive Index Matching method was applied to measure high-resolution buoyant jets with up to 8.6% density difference. These data are free of the typical errors that characterize optical measurements of buoyancy driven flows (e.g., natural and mixed convection) where the refractive index of the fluid is inhomogeneous throughout the measurement domain. Turbulent statistics and entrainment of buoyant jets in uniform and stratified environments are presented. These data are compared with non-buoyant jets in uniform environment, as a reference to investigate the effects of buoyancy and stratification on turbulent mixing. The results will be used for the assessment of current turbulence models and as basis for the development of a new one that captures turbulent mixing.

42 ENGINEERING↗

Tomographic X-ray particle tracking velocimetry

We investigate the feasibility of in-laboratory tomographic X-ray particle tracking velocimetry (TXPTV) and consider creeping flows with nearly density matched flow tracers. Specifically, in these proof-of-concept experiments we examined a Poiseuille flow, flow through porous media and a multiphase flow with a Taylor bubble. For a full 360° computed tomography (CT) scan we show that the specially selected 60 micron tracer particles could be imaged in less than 3 seconds with a signal-to-noise ratio between the tracers and the fluid of 2.5, sufficient to achieve proper volumetric segmentation at each time step. In the pipe flow, continuous Lagrangian particle trajectories were obtained, after which all the standard techniques used for PTV or PIV (taken at visible wave lengths) could also be employed for TXPTV data. And, with TXPTV we can examine flows inaccessible with visible wave lengths due to opaque media or numerous refractive interfaces. In the case of opaque porous media we were able to observe material accumulation and pore clogging, and for flow with Taylor bubble we can trace the particles and hence obtain velocities in the liquid film between the wall and bubble, with thickness of liquid film itself also simultaneously obtained from the volumetric reconstruction after segmentation. While improvements in scan speed are anticipated due to continuing improvements in CT system components, we show that for the flows examined even the presently available CT systems could yield quantitative flow data with the primary limitation being the quality of available flow tracers.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Time-resolved particle image velocimetry measurements of the turbulent Richtmyer–Meshkov instability

Experiments are presented on the Richtmyer–Meshkov instability (RMI) with a three-dimensional, multi-mode initial perturbation. The experiments use a vertical shock tube, where a stably stratified interface is formed between air and sulphur hexafluoride (SF 6 ) via counterflow. A perturbation is imposed at the interface by vertical oscillation of the gas column, forming Faraday waves. The interface is accelerated by a Mach 1.17 (in air) shock wave, and the development of the mixing region between the gases is investigated using particle image velocimetry. Following shock acceleration, a reflected shock wave from the bottom of the shock tube interacts with the mixing layer a second time (reshock). The experiment is initialized with both high and low amplitude perturbations to examine the effect of the perturbation amplitude on measured quantities. The instability growth exponent (θ) is determined from the kinetic energy field using the width of the mixing layer and the decay of kinetic energy, which are found to be in agreement when the flow is most strongly excited. A growth exponent of θ ≈ 0.5 is found for all cases except the high-amplitude reshocked regime (where θ ≈ 0.33). High-amplitude experiments exhibit the transitional outer Reynolds number (Re ≡ hh˙/ν >10 4 ) required for mixing transition following the incident shock, and both experiments are elevated well above this threshold following reshock. However, neither set of experiments meet the more stringent requirements proposed by Zhou et al. (Phys. Rev.E, vol. 67, issue 5, 2003) which include the time dependent aspect of the RMI, an observation which is also made when examining the spectra.

42 ENGINEERING↗

Photonic Doppler velocimetry of ohmically exploded aluminum surfaces

Photonic Doppler Velocimetry (PDV) was used to measure the exploding surface of coated metal driven by lineal current density increasing at 3 × 10 15 A/m/s. Here, aluminum-6061 rods were coated with three thicknesses (5, 17, and 41 μm) of Parylene-N and driven to 850 kA in approximately 100 ns, with the metal thicker than the skin depth. According to PDV, the metal surface melts at 85 ± 13 T and expands with a constant acceleration. Then, at surface magnetic field 140-180 T, the metal acceleration begins to increase in time. Later, plasma forms on, and is correlated with PDV signal loss from, uncoated aluminum rods, 5-μm-coated rods, and 17-μm-coated rods, while no evidence suggests plasma forms on 41-μm-coated metal.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Extreme measurements with Photonic Doppler Velocimetry (PDV)

Photonic Doppler Velocimetry (PDV) is a fiber-based diagnostic for the extreme conditions created by high-speed impact, explosive detonation, electrical pulsed power, and intense laser ablation. PDV is a conceptually simple application of the optical Doppler effect, but measurements above 1 km/s only became practical at the beginning of the twenty-first century. In this work, I discuss the evolution of PDV, its operational details, practical analysis, and outstanding challenges.

47 OTHER INSTRUMENTATION↗

Effects and mitigation of pulsed power radiation on optical fiber velocimetry

We report optical fiber diagnostics are extensively used in pulsed power experiments, such as the Sandia Z machine. However, radiation produced in a pulsed power environment can significantly affect these measurements. Catastrophic fiber darkening may be mitigated with shielding, but no flexible material can stop all radiation produced by the machine and/or target. Radiation-induced refractive index modulations are particularly challenging for optical interferometry. Several approaches for radiation-tolerant photonic Doppler velocimetry are discussed here.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Simultaneous measurement of surface velocity and plasma density with interferometric velocimetry

The apparent velocity measured by an interferometric surface velocimeter is a function of both the surface velocity and the time derivative of the refractive index along the measurement path. We employed this dual sensitivity to simultaneously measure km/s surface velocities and 10 18 cm -3 average plasma densities with combined VISAR (velocity interferometer system for any reflector) and PDV (photonic Doppler velocimetry) measurements in experiments performed on the Z Pulsed Power Facility. We detail the governing equations, associated assumptions, and analysis specifics and show that the surface velocity can be extracted without knowledge of the specific plasma density profile.

47 OTHER INSTRUMENTATION↗

A Bayesian approach to time-domain photonic Doppler velocimetry analysis

Photonic Doppler velocimetry (PDV) is an established technique for measuring the velocities of fast-moving surfaces in high-energy-density experiments. In the standard approach to PDV analysis, the short-time Fourier transform (STFT) is used to generate a spectrogram from which the velocity history of the target is inferred. The user chooses the form, duration, and separation of the window function. Here, in this study, we present a Bayesian approach to infer the velocity directly from the PDV oscilloscope trace, without using the spectrogram for analysis. This is clearly a difficult inference problem due to the highly periodic nature of the data, but we find that with carefully chosen prior distributions for the model parameters, we can accurately recover the injected velocity from synthetic data. We validate this method using PDV data collected at the STAR two-stage light gas gun at Sandia National Laboratories, recovering shock-front velocities in quartz that are consistent with those inferred using the STFT-based approach and are interpolated across regions of low signal-to-noise data. Although this method does not rely on the same user choices as the STFT, we caution that it can be prone to misspecification if the chosen model is not sufficient to capture the velocity behavior. Analysis using posterior predictive checks can be used to establish whether a better model is required, although more complex models come with additional computational cost, often taking more than several hours to converge when sampling the Bayesian posterior. We, therefore, recommend it be viewed as a complementary method to that of the STFT-based approach.

Allison, James R. [First Light Fusion Ltd., Yarnto↗

Phase-based velocity extraction method for photonic Doppler velocimetry with potential higher time resolution

We present an extension of the [Takeda et al., J. Opt. Soc. Am. 72, 156 (1982)] phase extraction method to heterodyne photonic Doppler velocimetry applications. The method yields results equivalent to those obtained by the short-time Fourier transform (STFT), while offering potential improvements in time resolution. Unlike STFT, which relies on window functions, such as the Hamming window, that emphasize central data points and diminish the influence of edges, the extended Takeda method utilizes all data uniformly. This uniform treatment allows for the derivation of empirical equations that directly relate velocity error to the actual time resolution rather than to the local analysis duration. The established equation provides a useful metric for both optimizing hardware configuration and guiding data analysis. Simulation and experimental results confirm that, for a given dataset, specifying a target time resolution yields consistent velocity errors for both methods. These findings underscore the Takeda method’s advantages, particularly its potential higher time resolution and reduced computational burden, making it a valuable tool for high-throughput applications such as laser dynamic compression experiments.

Computer simulation↗

Artificial intelligence velocimetry and microaneurysm-on-a-chip for three-dimensional analysis of blood flow in physiology and disease

Significance Microfluidics is an important in vitro platform to gain insights into mechanics of blood flow and mechanisms of pathophysiology of human diseases. Extraction of 3D fields in microfluidics with dense cell suspensions remains a formidable challenge. We present artificial-intelligence velocimetry (AIV) as a general platform to determine 3D flow fields and a microaneurysm-on-a-chip to simulate blood flow in microaneurysms in patients with diabetic retinopathy. AIV is built on physics-informed neural networks that integrate seamlessly 2D images from microfluidic experiments or in vivo observations with physical laws to estimate full 3D velocity and stress fields. AIV could be integrated into imaging technologies to automatically infer key hemodynamic metrics from in vivo and in vitro biomedical images.

42 ENGINEERING↗

Windowed Fourier transform and cross-correlation algorithms for molecular tagging velocimetry

In this study, simulated and experimental molecular tagging velocimetry (MTV) images have been analyzed with a technique commonly used to process grid images on surfaces, the windowed Fourier transform with local spectrum analysis (WFT-LSA). A systematic synthetic image study of the modulation transfer function (MTF) and error tendencies of the WFT-LSA was performed and compared with a PIV-style cross-correlation algorithm to see if advanced strategies such as iterative image deformation can improve analysis of gridded images with high noise levels. Testing of single-pass algorithms showed that in typical MTV images, the WFT-LSA yields significantly lower bias errors than cross-correlation (CC) at displacements greater than 1 pixel but slightly higher random error at all displacements and image conditions. Analysis of the MTF shows that CC provided better resolution of spatial fluctuations than the WFT-LSA in many combinations of grid size and interrogation window. Tests of image deformation algorithms showed that the gap in performance between CC and WFT-LSA is maintained even as both methods improve. Additionally, WFT-LSA and CC methods are applied to real MTV experiments in high-speed gas jet flows. A preliminary analysis of phosphorescence lifetime provided by acetone vapor excited at 266 nm is used for assessing the required gas speeds for making MTV application feasible. The application of WFT-LSA to real MTV images demonstrates the ability of the algorithm to handle further real-world effects that could not be considered in the synthetic image analysis, like reduced signal-to-noise ratio and non-uniform intensity of the tagging grid across the image introduced by the actual laser beam energy distribution. With experimental images, CC is more accurate with shear flows but less robust to high noise levels than WFT-LSA, as predicted by the synthetic image analysis.

42 ENGINEERING↗

Meta-uncertainty for particle image velocimetry

Uncertainty quantification for Particle Image Velocimetry (PIV) is critical for comparing experimentally measured flow fields with Computational Fluid Dynamics (CFD) results, and model design and validation. However, PIV features a complex measurement chain with coupled, non-linear error sources, and quantifying the uncertainty is challenging. Multiple assessments show that none of the current methods can reliably measure the actual uncertainty across a wide range of experiments, and estimates can vary. Because the current methods differ in assumptions regarding the measurement process and calculation procedures, it is not clear which method is best to use for an experiment where the error distribution is unknown. To address this issue, we propose a method to estimate an uncertainty method's sensitivity and reliability, termed the Meta-Uncertainty. The novel approach is automated, local, and instantaneous, and based on perturbation of the recorded particle images. We developed an image perturbation scheme based on adding random unmatched particles to the interrogation window pair considering the signal-to-noise (SNR) of the correlation plane. Each uncertainty scheme's response to several trials of random particle addition is used to estimate a reliability metric, defined as the rate of change of the inter-quartile range (IQR) of the uncertainties with increasing levels of particle addition. We also propose applying the meta-uncertainty as a weighting metric to combine uncertainty estimates from individual schemes, based on ideas from the consensus forecasting literature. We use planar and stereo PIV measurements across a range of canonical flows to assess the performance of the uncertainty schemes. Further, a novel method is introduced to assess an uncertainty scheme's performance based on a quantile comparison of the error and uncertainty distributions, generalizing the current method of comparing the RMS of the two distributions. Here, the results show that the combined uncertainty method outperforms the individual methods, and this work establishes the meta-uncertainty as a useful reliability assessment tool for PIV uncertainty quantification.

47 OTHER INSTRUMENTATION↗

Particle image velocimetry analysis with simultaneous uncertainty quantification using Bayesian neural networks

Particle image velocimetry (PIV) is an effective tool in experimental fluid mechanics for extracting flow fields from images. Recently, convolutional neural networks (CNNs) have been used to perform PIV analysis with accuracy on par with classical methods. Here we extend the use of CNNs to analyze PIV data while providing simultaneous uncertainty quantification on the inferred flow field. The method we apply in this paper is a Bayesian convolutional neural network (BCNN) which learns distributions of the CNN weights through variational Bayes. In order to demonstrate the utility of BCNNs for the PIV task, we compare the performance of three distinct BCNN models with simple architectures. The first network estimates flow velocity from image interrogation regions only. Our second model learns to infer velocity from both the image interrogation regions and interrogation region cross-correlation maps. Finally, our best performing network infers velocities from interrogation region cross-correlation maps only. We find that BCNNs using interrogation region cross-correlation maps as inputs perform better than those using interrogation windows only as inputs and discuss reasons why this may be the case. Additionally, we test the best performing BCNN on a full synthetic test image pair and a real image pair from the 1st International PIV Challenge. We show that ~98% of true particle displacements from the full synthetic image pair can be captured within the BCNN's 95% confidence intervals, and that the BCNN's performance on the real image pair is quantitatively similar to that of algorithms tested in the 1st International PIV Challenge. Finally, we show that BCNNs can be generalized to be used with multi-pass PIV algorithms with a moderate loss in accuracy, which may be overcome by future work on finetuning and training schemes. So to our knowledge, this is the first use of Bayesian neural networks to perform PIV.

47 OTHER INSTRUMENTATION↗

Time-resolved particle image velocimetry

Time-resolved particle image velocimetry (TR-PIV) has become widespread in fluid dynamics. Essentially a velocity field movie, the dynamic content provides temporal as well as spatial information, in contrast to conventional PIV offering only statistical ensembles of flow quantities. From these time series arise further analyses such as accelerometry, space-time correlations, frequency spectra of turbulence including spatial variability, and derivation of pressure fields and forces. The historical development of TR-PIV is chronicled, culminating in an assessment of the current state of technology in high-repetition-rate lasers and high-speed cameras. Commercialization of pulse-burst lasers has expanded TR-PIV into more flows, including the compressible regime, and has achieved MHz rates. Particle response times and peak locking during image interrogation require attention but generally are not impediments to success. Accuracy considerations are discussed, including the risks of noise and aliasing in spectral content. Oversampled TR-PIV measurements allow use of multi-frame image interrogation methods, which improve the precision of the correlation and raise the velocity dynamic range of PIV. In combination with volumetric methods and data assimilation, a full four-dimensional description of a flow is not only achievable but becoming standardized. Lastly, a survey of exemplary applications is followed by a few predictions concerning the future of TR-PIV.

47 OTHER INSTRUMENTATION↗