Large variable conductance heat pipe. Transverse header

The characteristics of gas-loaded, variable conductance heat pipes (VCHP) are discussed. The difficulties involved in developing a large VCHP header are analyzed. The construction of the large capacity VCHP is described. A research project to eliminate some of the problems involved in large capacity VCHP operation is explained.

Edelstein, F.↗

Description and orbit data of variable-conductance heat-pipe system for the communications technology satellite

A variable-conductance heat-pipe system (VCHPS) with methanol as the working fluid and a nitrogen and helium mixture as the control gas was used for the thermal control of a 200 W RF traveling wave tube of the Communication Technology Satellite. Three stainless steel heat pipes (one redundant) and an aluminum radiator were designed to transfer 196 watts for an evaporator temperature of 50 C. The system has operated for three years with no noticeable change in performance. On four occasions the heat pipes apparently deprimed. A short time after reducing the tube power, the heat pipes reprimed and the system continued to operate normally. The description, qualification testing, and orbit data of the VCHPS are presented.

Gedeon, L.↗

Variable conductance heat pipe technology for precise temperature control of the NASA/DDLT transmitter

The application of variable conductance heat pipe technology for achieving precise temperature control to + or - 0.1 C for a space-based laser diode transmitter is described. Heat pipe theory of operation and test data are presented along with a discussion of its applicability for NASA's Direct Detection Laser Transceiver (DDLT) program. This design for the DDLT transmitter features a reduction in space radiator size and up to 42 percent reduction in prime power requirements.

Vanevenhoven, D. E.↗

Variable conductance heat pipes from the laboratory to space

Heat pipes were developed which can be used as (1) a variable conductance link between a heat source and sink which provides temperature stability; (2) a feedback control mechanism that acts to directly maintain the source at a constant temperature; (3) or as a thermal diode that allows heat to be transferred in one direction only. To establish flight level confidence in these basic control techniques, the Ames Heat Pipe Experiment (AHPE) was launched in August 1972 and the Advanced Thermal Control Flight Experiment (ATFE) is scheduled for launch in May 1973. The major efforts of the technology development, initial flight results of the AHPE, and ground test data of the ATFE are discussed.

Kirkpatrick, J. P.↗

Computer Program For Variable-Conductance Heat Pipes

VCHPDA provides accurate mathematical models of transient as well as steady-state performance of variable-conductance heat pipes over wide range of operating conditions. Applies to heat pipes with either cold, wicked or hot, nonwicked gas reservoirs and uses ideal-gas law and "flat-front" (negligible vapor diffusion) gas theory. Calculates length of gas-blocked region and temperature of vapor in active portion of heat pipe by solving set of nonlinear equations for conservation of energy and mass. Written in FORTRAN 77.

Antoniuk, D.↗

Variable Conductance Heat Pipe Cooling of Stirling Convertor and General Purpose Heat Source

In a Stirling Radioisotope Power System (RPS), heat must be continuously removed from the General Purpose Heat Source (GPHS) modules to maintain the modules and surrounding insulation at acceptable temperatures. The Stirling convertor normally provides this cooling. If the Stirling convertor stops in the current system, the insulation is designed to spoil, preventing damage to the GPHS at the cost of an early termination of the mission. An alkali-metal Variable Conductance Heat Pipe (VCHP) can be used to passively allow multiple stops and restarts of the Stirling convertor. In a previous NASA SBIR Program, Advanced Cooling Technologies, Inc. (ACT) developed a series of sodium VCHPs as backup cooling systems for Stirling RPS. The operation of these VCHPs was demonstrated using Stirling heater head simulators and GPHS simulators. In the most recent effort, a sodium VCHP with a stainless steel envelope was designed, fabricated and tested at NASA Glenn Research Center (GRC) with a Stirling convertor for two concepts; one for the Advanced Stirling Radioisotope Generator (ASRG) back up cooling system and one for the Long-lived Venus Lander thermal management system. The VCHP is designed to activate and remove heat from the stopped convertor at a 19 degC temperature increase from the nominal vapor temperature. The 19 degC temperature increase from nominal is low enough to avoid risking standard ASRG operation and spoiling of the Multi-Layer Insulation (MLI). In addition, the same backup cooling system can be applied to the Stirling convertor used for the refrigeration system of the Long-lived Venus Lander. The VCHP will allow the refrigeration system to: 1) rest during transit at a lower temperature than nominal; 2) pre-cool the modules to an even lower temperature before the entry in Venus atmosphere; 3) work at nominal temperature on Venus surface; 4) briefly stop multiple times on the Venus surface to allow scientific measurements. This paper presents the experimental results from integrating the VCHP with an operating Stirling convertor and describes the methodology used to achieve their successful combined operation.

Stirling Radioisotope Power System↗

CTS-type variable conductance heat pipes for SEP FM/PPU

The development effort for, and the fabrication and testing of, six CTS-type variable conductance heat pipes is described. The heat pipes are constructed of stainless steel, use methanol as a working fluid, and a nitrogen/helium mixture as the control gas. The wicking structure consists of interior wall grooves, a metal-felt diametral slab wick, and two wire-mesh arteries. The heat pipes are used to cool two Functional Model/Power Processing Units in a Solar Electric Propulsion prototype BIMOD thruster subsystem assembly. The Power Processing Units convert the electric power from a spacecraft solar array system to the voltages required to operate the electric thrusters which are part of the BIMOD assembly.

Antoniuk, D.↗

Development of a high capacity variable conductance heat pipe.

The high-capacity, pressure-primed, tunnel-artery wick concept was used in a gas-controlled variable conductance heat pipe. A variety of techniques were employed to control the size of gas/vapor bubbles trapped within the artery. Successful operation was attained with a nominal 6-foot long, 1-inch diameter cold reservoir VCHP using ammonia working fluid and nitrogen control gas. The pipe contained a heat exchanger to subcool the liquid in the artery. Maximum transport capacity with a 46-inch effective length was 1200 watts level (more than 50,000 watt-inches) and 800 watts at 0.5-inch adverse tilt.

Kosson, R.↗

Flight data analysis and further development of variable-conductance heat pipes

Continuing efforts in large gains in heat-pipe performance are reported. It was found that gas-controlled variable-conductance heat pipes can perform reliably for long periods in space and effectively provide temperature stabilization for spacecraft electronics. A solution was formulated that allows the control gas to vent through arterial heat-pipe walls, thus eliminating the problem of arterial failure under load, due to trace impurities of noncondensable gas trapped in an arterial bubble during priming. This solution functions well in zero gravity. Another solution was found that allows priming at a much lower fluid charge. A heat pipe with high capacity, with close temperature control of the heat source and independent of large variations in sink temperature was fabricated.

Enginer, J. E.↗

Application of axial grooves to cryogenic variable conductance heat pipe technology

Tests results obtained with an ATS axial groove aluminum extrusion adapted for use as a cryogenic thermal diode and/or a variable conductance heat pipe are presented. Ethane at a nominal operating temperature of 185 C was used as working fluid. In addition to both active and passive gas control, diode designs utilizing gas blockage or liquid trap were investigated. Specific requirements and performance parameters such as transient behavior, reservoir sizes, shutdown energy, etc., were evaluated. Results are also presented for tests where the liquid trap was used as a secondary heat pipe to demonstrate thermal switching with simultaneous heat pipe operation and diode shutdown.

Brennan, P. J.↗

Design and evaluation of a rotating variable conductance heat pipe system

Analysis of the Dynamics Explorer high orbiter spacecraft showed that the proposed louver system, along with existing radiator heat rejection areas on the S/C surface were insufficient to safely control the S/C's thermal excursions caused by highly varying internal power levels and solar input angles. A variable conductance heat pipe system in conjunction with a conventional radial heat pipe system was designed, built, tested, and shown to resolve this problem. The conventional pipes, radial, spinning at 10 rpm were required to carry 35 watts each after experiencing despin from 80 rpm. The VCHPs attached to the radial pipes at the S/C perimeter distributed the excess energy via a finned radiator attached around the S/C's center.

Marshburn, J. P.↗

A variable conductance gas switch for intermediate temperature operation of liquid He/liquid N2 cryostats

A technique for establishing a stable intermediate temperature stage in liquid He/liquid N2 double vessel cryostats is described. The tertiary cold stage, which can be tuned to any temperature between 10 and 60 K, is ideal for cooling IR sensors for use in astronomy and physics applications. The device is called a variable-conductance gas switch. It is essentially a small chamber, located between the cold stage and liquid helium cold-face, whose thermal conductance may be controlled by varying the pressure of helium gas within the chamber. A key feature of this device is the large range of temperature control achieved with a very small (less than 10 mW) heat input from the cryogenic temperature control switch.

Rayner, J. T.↗

Vapor-modulated heat pipe report. Flight data analysis and further development of variable-conductance heat pipes

The design and testing of a heat pipe for spacecraft application is presented. The application in mind calls for heat loads up to 20 watts, a set-point temperature of 294K, and a sink that varies from -220K to nearly as high as the set-point. The overall heat pipe length is 137 cm. Two basically different mechanisms of achieving variable conductance in the pipe by vapor-flow throttling were studied. In one, the thermal resistance between the heat source and sink is due to a saturation-temperature drop corresponding to the vapor-pressure drop developed across the valve. In the other, the pressure difference across the valve induces capillary groove and wick dry out in an evaporation region, and thus results in an increased thermal resistance. This mechanism was selected for fabrication and testing. The pipe is a stainless-steel/methanol two-heat-pipe system. Results are presented and discussed. Engineering drawings and specifications of the pipe are shown.

Eninger, J. E.↗

Variable Conductance Heat Pipes for Radioisotope Stirling Systems

In a Stirling radioisotope system, heat must continually be removed from the GPHS modules, to maintain the GPHS modules and surrounding insulation at acceptable temperatures. Normally, the Stirling convertor provides this cooling. If the Stirling engine stops in the current system, the insulation is designed to spoil, preventing damage to the GPHS, but also ending the mission. An alkali-metal Variable Conductance Heat Pipe (VCHP) was designed to allow multiple stops and restarts of the Stirling engine. A VCHP turns on with a delta T of 30 C, which is high enough to not risk standard ASRG operation but low enough to save most heater head life. This VCHP has a low mass, and low thermal losses for normal operation. In addition to the design, a proof-of-concept NaK VCHP was fabricated and tested. While NaK is normally not used in heat pipes, it has an advantage in that it is liquid at the reservoir operating temperature, while Na or K alone would freeze. The VCHP had two condensers, one simulating the heater head, and the other simulating the radiator. The experiments successfully demonstrated operation with the simulated heater head condenser off and on, while allowing the reservoir temperature to vary over 40 to 120 C, the maximum range expected. In agreement with previous NaK heat pipe tests, the evaporator delta T was roughly 70 C, due to distillation of the NaK in the evaporator.

Anderson, William G.↗

High Temperature Variable Conductance Heat Pipes for Radioisotope Stirling Systems

In a Stirling radioisotope system, heat must continually be removed from the GPHS modules, to maintain the GPHS modules and surrounding insulation at acceptable temperatures. Normally, the Stirling convertor provides this cooling. If the Stirling convertor stops in the current system, the insulation is designed to spoil, preventing damage to the GPHS, but also ending the mission. An alkali-metal Variable Conductance Heat Pipe (VCHP) is under development to allow multiple stops and restarts of the Stirling convertor. The status of the ongoing effort in developing this technology is presented in this paper. An earlier, preliminary design had a radiator outside the Advanced Stirling Radioisotope Generator (ASRG) casing, used NaK as the working fluid, and had the reservoir located on the cold side adapter flange. The revised design has an internal radiator inside the casing, with the reservoir embedded inside the insulation. A large set of advantages are offered by this new design. In addition to reducing the overall size and mass of the VCHP, simplicity, compactness and easiness in assembling the VCHP with the ASRG are significantly enhanced. Also, the permanently elevated temperatures of the entire VCHP allows the change of the working fluid from a binary compound (NaK) to single compound (Na). The latter, by its properties, allows higher performance and further mass reduction of the system. Preliminary design and analysis shows an acceptable peak temperature of the ASRG case of 140 C while the heat losses caused by the addition of the VCHP are 1.8 W.

Tarau, Calin↗

Sodium Variable Conductance Heat Pipe for Radioisotope Stirling Systems

In a Stirling radioisotope system, heat must continually be removed from the General Purpose Heat Source (GPHS) modules to maintain the modules and surrounding insulation at acceptable temperatures. Normally, the Stirling convertor provides this cooling. If the converter stops in the current system, the insulation is designed to spoil, preventing damage to the GPHS, and also ending the mission. An alkali-metal Variable Conductance Heat Pipe (VCHP) has been designed to allow multiple stops and restarts of the Stirling convertor in an Advanced Stirling Radioisotope Generator (ASRG). When the Stirling convertor is turned off, the VCHP will activate when the temperatures rises 30 C above the setpoint temperature. A prototype VCHP with sodium as the working fluid was fabricated and tested in both gravity aided and against gravity conditions for a nominal heater head temperature of 790 C. The results show very good agreement with the predictions and validate the model. The gas front was located at the exit of the reservoir when heater head temperature was 790 C while cooling was ON, simulating an operating Advanced Stirling Converter (ASC). When cooling stopped, the temperature increased by 30 C, allowing the gas front to move past the radiator, which transferred the heat to the case. After resuming the cooling flow, the front returned at the initial location turning OFF the VCHP. The against gravity working conditions showed a colder reservoir and faster transients.

Tarau, Calin↗

A variable conductance heat pipe/radiator for the lunar surface magnetometer.

The device was developed to supplement the existing cooling system of the Apollo 16 Lunar Surface Magnetometer (LSM). Analysis and tests showed that two such devices, inserted by an astronaut into receptacles on opposite sides of the electronics package, would reduce the diurnal temperature variation by about 40% and thereby would considerably increase the reliability of 50,000 welded connections. The LSM design constraints, selection of a variable conductance technique, heat pipe/radiator design features, and thermal performance are discussed.

Kirkpatrick, J. P.↗