At least 37 records · Page 2

Fabrication of a composite anion exchange membrane with aligned ion channels for a high-performance non-aqueous vanadium redox flow battery

Fabrication of high-conductivity ion exchange membranes (IEMs) is crucial to improve the performance of non-aqueous vanadium redox flow batteries (NAVRFBs). In the present work, anion exchange membranes with high-conductivity were fabricated by aligning ion channels of the polymer electrolyte impregnated in porous polytetrafluoroethylene (PTFE) under electric fields. It was observed that the ion channels of the polymer electrolyte were uniformly orientated in the atomic-force microscopy image. Its morphological change could minimize detouring of the transport of BF 4 - ions. The results showed through-plane conductivity was improved from 12.7 to 33.1 mS cm -1 . The dimensional properties of the fabricated membranes were also enhanced compared with its cast membrane owing to the reinforcing effect of the substrate. Especially, the NAVRFB assembled with the optimized membrane showed increased capacities, with a 97% coulombic efficiency and 70% energy efficiency at 80 mA cm -2 . Furthermore, the optimized membrane made it possible to operate the NAVRFB at 120 mA cm -2 . Its operating current density was 120 times higher than that of a frequently used AHA membrane for RFBs.

25 ENERGY STORAGE↗

Novel artificial neural network model for instantaneous power losses and operational efficiency mapping of MW-scale vanadium redox flow battery for improved technoeconomic analysis

A novel data-driven, machine-learning-based method for modeling the instantaneous power losses of a distribution-sited 2 MW/8MWh vanadium redox flow battery (VRFB), a grid-scale electrochemical storage technology, is introduced and compared against benchmark empirical modeling approaches, including symmetric and asymmetric models, as well as a recent convex hull modeling approach. The novel loss modeling method introduces several advantages over the benchmark models and over simplistic efficiency estimates, the most significant of which is that the model can accurately reflect the stepwise and non-linear parasitic losses associated with the duty cycles of mechanical auxiliary systems like pump motor drives and blower fans. Residuals of the models are compared; the proposed data driven model features significantly improved accuracy over the benchmark models. The model's coefficient of determination is also improved relative to that of the benchmark models. Furthermore, a novel method for visualization of operational efficiency of the grid-scale storage technology is introduced. To demonstrate the benefits of the novel data-driven method for modeling the VRFB, the benchmark models and the proposed models are embedded into an Open DSS distribution network model to study two applications of the grid-scale electrical storage system: load leveling for grid support and energy arbitrage. This article demonstrates that the accuracy of the instantaneous power loss model significantly impacts the understanding of the state of charge of the VRFB. In turn, the accuracy of the efficiency modeling of the VRFB impacts the understanding of the potential economic value and technical benefits to the distribution network operators. In conclusion, the presented power loss modeling approach is, therefore, highly relevant for utility-stakeholders, battery asset owners, system engineers, system designers, and financial planners interested in evaluating or optimizing the operation of grid-scale VRFBs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Proton Selective Nanoporous Atomically Thin Graphene Membranes for Vanadium Redox Flow Batteries

Angstrom-scale proton-selective pores in atomically thin 2D materials present fundamentally new opportunities for advancing proton exchange membranes (PEMs). Vanadium Redox Flow Batteries (VRFBs) for grid-scale energy storage require PEMs with high areal proton conductance (>1 S cm −2 ) and minimal vanadium ion (VO 2+ ) crossover. However, state-of-the-art Nafion 212 membranes (N212 ≈50 µm thick), suffer from persistent VO 2+ crossover reducing performance and efficiency. Here, a layered PEM is demonstrated, comprising monolayer CVD graphene with Angstrom-scale proton-selective pores introduced via Ar plasma, integrated with an ultra-thin ≈300 nm polybenzimidazole (PBI) layer and sandwiched between two Nafion 211 (25 µm thick) layers. The layered architecture facilitates scalable membrane fabrication by mitigating defects while processing and facile stacking of graphene layers allows stochastic non-selective defect isolation enabling exceptionally low VO 2+ crossover (selectivity (H + areal conductance / VO 2+ permeability) ≈6709 × 10 6 S min cm −4 ), with proton conductance >8 S cm −2 . Systematic transport experiments supported by resistance-based transport modelling elucidate the role of defect size, defect isolation, and sealing, as well as layering/stacking, to enable orders of magnitude (>671× over N212) improvements in selectivity, along with areal proton conductance >8 S cm −2 . This work highlights the potential of atomic-scale proton-selective defect engineering in 2D materials, in conjunction with facile stacking and layering of materials as strategies for scalable, high-performance advances in PEMs for energy, electrochemical, and separation applications beyond VRFBs.

Chaturvedi, Pavan [Vanderbilt Univ., Nashville, TN↗

Real-time Simulation Model of a Vanadium Redox Flow Battery Energy Storage System with Power Electronics Integration

This paper presents a real-time (RT) model of a 20 kW multi-stack vanadium redox flow battery (VRFB) system including power electronics converters in a single real-time framework. Implemented on a Typhoon HIL 604 device, this model is designed to simulate the operation of the flow battery with system-level controls. To provide a realistic overview of a VRFB system, the model incorporates a closed-loop control system for managing the speeds of two centrifugal pumps and an electro-thermal model of the battery stacks, enabling realtime temperature estimation. Furthermore, a two-stage power electronics topology and associated control solution are presented, operating with distinct strategies for interfacing the battery model with the main grid and a local load. Results from simulations demonstrate that the VRFB model is well suited for RT environment, and system can manage power during both charging and discharging cycles, while a SCADA monitor is used to display critical variables for safe, efficient, and reliable operation of the VRFB systems.

Rezende Da Costa Reis Kimpara, Renata [ORNL] (ORCI↗

Enhanced physics-constrained deep neural networks for modeling vanadium redox flow battery

Numerical simulation has become indispensable in advancing cost-effective process optimization and control of flow batteries. We propose an enhanced version of the physics-constrained deep neural network (PCDNN) approach to provide high-accuracy voltage predictions in the vanadium redox flow batteries (VRFBs). The purpose of the PCDNN approach is to enforce the physics-based zero-dimensional (0D) VRFB model in a neural network to assure model generalization for various battery operation conditions. However, limited by the simplifications of the 0D model, the PCDNN cannot capture sharp voltage changes in the extreme SOC regions. To improve the accuracy of voltage prediction at extreme ranges, we introduce a second (enhanced) DNN to mitigate the prediction errors carried from the 0D model itself and call the resulting approach enhanced PCDNN (ePCDNN). By comparing with experimental data, we demonstrate that the ePCDNN approach can accurately capture the voltage response throughout the charge–discharge cycle, including the tail region of the voltage discharge curve. The loss function for training the ePCDNN is designed to be flexible by adjusting the weights of the physics-constrained DNN and the enhanced DNN. In conclusion, this allows the ePCDNN framework to be transferable to battery systems with variable physical model fidelity.

25 ENERGY STORAGE↗

Direct Measurement of Crossover and Interfacial Resistance of Ion-Exchange Membranes in All-Vanadium Redox Flow Batteries

Among various components commonly used in redox flow batteries (RFBs), the separator plays a significant role, influencing resistance to current as well as capacity decay via unintended crossover. It is well-established that the ohmic overpotential is dominated by the membrane and interfacial resistance in most aqueous RFBs. The ultimate goal of engineering membranes is to improve the ionic conductivity while keeping crossover at a minimum. One of the major issues yet to be addressed is the contribution of interfacial phenomena in the influence of ionic and water transport through the membrane. In this work, we have utilized a novel experimental system capable of measuring the ionic crossover in real-time to quantify the permeability of ionic species. Specifically, we have focused on quantifying the contributions from the interfacial resistance to ionic crossover. The trade-off between the mass and ionic transport impedance caused by the interface of the membranes has been addressed. The MacMullin number has been quantified for a series of electrolyte configurations and a correlation between the ionic conductivity of the contacting electrolyte and the Nafion® membrane has been established. The performance of individual ion-exchange membranes along with a stack of various separators have been explored. We have found that utilizing a stack of membranes is significantly beneficial in reducing the electroactive species crossover in redox flow batteries compared to a single membrane of the same fold thickness. For example, we have demonstrated that the utilization of five layers of Nafion ® 211 membrane reduces the crossover by 37% while only increasing the area-specific resistance (ASR) by 15% compared to a single layer Nafion ® 115 membrane. Therefore, the influence of interfacial impedance in reducing the vanadium ion crossover is substantially higher compared to a corresponding increase in ASR, indicating that mass and ohmic interfacial resistances are dissimilar. We have expanded our analysis to a combination of commercially available ion-exchange membranes and provided a design chart for membrane selection based on the application of interest (short duration/high-performance vs. long-term durability). The results of this study provide a deeper insight into the optimization of all-vanadium redox flow batteries (VRFBs).

UV/Vis spectroscopy↗

A hybrid analytical and numerical model for cross-over and performance decay in a unit cell vanadium redox flow battery

Developing an accurate and efficient model for cross-over is critical for improving the long-term performance of redox flow batteries (RFBs). Here, this work presents a hybrid analytical and numerical model that combines a two-dimensional analytical solution to the active species, a one-dimensional analytical model for cross-over mechanisms, and a zero-dimensional numerical model for outlet concentrations of reactants. By comparing with experiment over 41 cycles (ca. 144 h), the model reported a mean voltage difference of 0.0089 V, mean time difference of 14 s per cycle (of 3.5 h), maximum relative difference for capacity and energy of 1.34% and 1.63%, respectively. The predicted mean concentrations for V 2+ , V 3+ , and VO$_{2}^{+}$ in membrane are 65%~77% of measured values from the literature. Upon validation, the model reproduced behaviors in electrolyte imbalance similar to those observed in experiments and numerical models, and revealed the control of cross-over, self-discharge, stoichiometry of side reactions, and Coulombic efficiency on electrolyte imbalance. The model also demonstrates excellent computational efficiency for simulating 41 cycles (around 37,000 points) within 3~4 s. The demonstrated efficiency and accuracy for predicting cross-over and its impacts on voltage, capacity&energy decay, membrane concentrations, and electrolyte imbalance makes it a reliable tool for optimizing RFBs’ long-term performance.

25 ENERGY STORAGE↗

In Situ Reliability Investigation of All-Vanadium Redox Flow Batteries by a Stable Reference Electrode

Redox flow batteries (RFBs) have been studied over the past several decades as a promising candidate for stationary energy storage applications. It is therefore important to understand the reliability of RFBs and the mechanisms that cause degradation with time. Contributions from individual electrodes (cathode or anode) are difficult to separate especially for long-term cycle testing, due to the lack of a stable reference electrode. In our work, the reliability and degradation mechanisms of an all-vanadium RFB were investigated by a stable reference electrode based on the dynamic hydrogen electrode (DHE). With factor exploration and design optimization, the newly developed DHE reference electrode demonstrated high accuracy and long-term stability that enables in-situ monitoring of individual electrode signals (potentials and impedances) over hundreds of cycles in a vanadium RFB. This approach enables the full cell degradation to be separated and the degradation attributed to contributions from the cathode and anode. The cathode and anode were found to play quite different roles in the increase in overpotential of the vanadium RFB during long-term cycling. The anode reaction limited both the charge and discharge capacity over 100 cycles. In addition, the negative side also appeared to be the rate limiting factor throughout cycling as determined by EIS measurement. The cathode contributed to the performance degradation as cycling exceeded 50 cycles.

Huang, Qian↗

Long-Term Structural and Chemical Stability of Carbon Electrodes in Vanadium Redox Flow Battery

Predicting the performance decay in carbon electrodes is critical to maximizing the longevity of redox flow battery (RFB) systems. This study investigates the effect of long-term cycling (over 8000 cycles) on the structural and chemical evolution of carbon electrodes. We find that the microstructural aspects such as graphitic stacking order and interlayer spacing along with overall morphological construct remains largely unchanged even after the prolonged cycling process. Conversely, significant changes in surface chemistry such as evolution of functional groups and point defects are evident from our combined multimodal spectroscopic and computational analysis. The XPS and FTIR analysis reveals chemical absorption of chloride counter anions at point defects within graphitic surface. Additionally, our results suggest that vanadium cation plays an important role in counter anion-carbon surface interaction and subsequently the surface chemistry evolutions. Our findings provide insights about surface chemical evolution that is critical for predicting electrode performance and longevity of RFB.

Modachur Sivakumar, Bhuvaneswari↗