Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “value of resilience”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Residential Vehicle-to-Home Backup Power Capabilities: Key Findings from a ComEd Beneficial Electrification R&D Pilot

This report summarizes key findings from a collaborative technical study of residential, non-grid-tied vehicle-to-home (V2H) backup power systems in Commonwealth Edison’s (ComEd’s) service territory. The work integrates (1) a feeder-level technoeconomic analysis (TEA) using historical outage-event data and simulated electric-vehicle (EV) driving/charging profiles to estimate potential reliability and customer interruption-cost impacts under V2H and vehicle-to-grid (V2G) adoption scenarios; (2) controlled laboratory performance testing of a representative V2H backup ecosystem to characterize transfer-to-backup behavior, sustained power delivery, efficiency trends, and repeatable reliability limitations; and (3) a cybersecurity assessment aligned with NIST Cybersecurity Framework (CSF) 2.0 and ISO/SAE 21434 to evaluate interface-level risk drivers and identify program-relevant mitigations. Results indicate that V2H can provide measurable resilience value, but outcomes are strongly context dependent on outage patterns and the share of events that are “V2H-applicable.” Typical transfer-to-backup behavior clustered on the order of minutes, but rare long-delay edge cases were observed (including an event approaching 30 minutes) and should be treated as a reliability risk. High-power testing showed that peak-rated output is not necessarily continuously deliverable; stable operation may require operation below nameplate ratings and attention to thermal and installation constraints. The cybersecurity assessment highlights a broad attack surface spanning commissioning, home networks, embedded services, and cloud/OTA pathways, motivating minimum controls for secure onboarding, signed updates, patch cadence, and coordinated vulnerability response for any scaled deployment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Behind the Meter Solar+Storage: Market data and trends [Slides]

As the distributed solar market evolves toward more dynamic forms of deployment, interest in paired solar-plus-storage applications continues to gain steam, but details on the current state of the market are relatively sparse. To fill that void, Berkeley Lab has released an in-depth analysis of this budding market segment. This report draws on the Lab’s Tracking the Sun dataset to characterize trends in deployment, system sizing and equipment selection, installer-market development, and system pricing. The report also provides indicative analyses of the financial and resilience value that host customers in several key markets presently receive by pairing storage with solar.

14 SOLAR ENERGY↗

Quantifying grid reliability and resilience impacts of energy efficiency: Examples and opportunities

Traditional reliability and emerging resilience metrics may not fully recognize benefits from distributed energy resources (DERs) such as energy efficiency. This technical brief explains how existing planning processes for bulk power and distribution systems capture the impact of energy efficiency on power system reliability and resilience with illustrative examples. We identify limitations in using existing reliability and resilience metrics to quantify efficiency and other DER benefits. The brief concludes with a discussion of opportunities to enhance current planning practices to better capture the reliability and resilience value of energy efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Understand the Costs of an Energy or Water Outage with the Customer Damage Function Calculator

The Customer Damage Function (CDF) Calculator is a free, publicly available web tool that helps users estimate the costs incurred at their site due to an electric grid or water service outage. Developed by the National Renewable Energy Laboratory (NREL) with support from the Federal Energy Management Program (FEMP), the tool is designed to help federal facility owners, building energy managers, and resilience planners understand and quantify the value of resilience to justify investments that would prevent or lessen the impact of a disruption.

CDF Calculator↗

When the lights go out

In the face of more frequent long-duration power outages, utilities are looking to invest in more resilient infrastructure and solutions. This paper explains a new study that shows that residential customers are willing to pay for increased resilience and will spend extra to support their communities and low-income neighbours.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluating Utility Costs Savings and Resilience: A Case Study in Port Arthur, Texas

This study evaluates the techno-economic feasibility of integrating solar photovoltaics (PV), battery energy storage systems (BESS), and generators to enhance both cost savings and resilience in critical community facilities in Port Arthur, Texas. Using NREL's REopt model, we analyze four facilities: the Golden Triangle Empowerment Center (GTEC), Lamar State College (LSC), Port Arthur Independent School District (PAISD), and Port Arthur Transit (PAT). A key aspect of the analysis is the incorporation of the Value of Lost Load (VoLL) and microgrid upgrade costs to assess the hidden value of resilience during grid outages. While standalone PV scenarios show moderate cost reductions and a 10-15% decrease in CO2 emissions, the inclusion of resilience measures with BESS and generators significantly increases system costs. However, the hidden value of resilience - quantified through avoided outage costs - leads to a substantial improvement in financial outcomes, resulting in positive Net Present Value (NPV) at many sites. The study demonstrates that resilient solar and storage systems offer both economic and resilience benefits, particularly for underserved communities, by balancing energy savings and enhanced operational continuity during outages.

14 SOLAR ENERGY↗

Case Study of the City of Reno: Resilience Valuation and Planning for Solar and Storage on Critical Infrastructure

This case study report documents the City of Reno's efforts to quantify the value of resilience and the entrepreneurial ways through which the City approached the questions of what role solar and storage could play in their resilience efforts and how to value and pay for solar-plus-storage systems. It documents how and why the City of Reno came to the specific conclusion to integrate solar and storage into their Public Safety Center retrofit project and apply for Federal Emergency Management Agency (FEMA) Building Resilient Infrastructure and Communities (BRIC) funding. This report provides an overview for other local governments to draw inspiration from when considering how to prioritize community values and pursue multi-stakeholder dialogue around resilient energy solutions. The City of Reno's experience can serve as a starting point for other communities interested in valuing the resilience benefits of solar and storage.

14 SOLAR ENERGY↗

Voices of Experience: Microgrids for Resiliency

Modern attitudes around microgrids have evolved, from the idea that microgrids represent "grid defection" to perceiving them as a tool that utilities can use to solve challenges. One such challenge is improving resiliency. Faced with unpredictable, yet intensifying and dynamic weather and cyber risks, the value of resiliency is only growing for utility customers, regulators, and policymakers. Moreover, policymakers and regulators are increasingly asking utilities to accommodate the expansion and enhancement of such resiliency. The purpose of Voices of Experience: Microgrids for Resiliency is to guide discussions around this topic - everything from defining the many types of microgrids, to siting, ownership, control, and value streams. Utilities who participated in this project were generous with their time, insights, and examples of how they are using microgrids to solve one of their most urgent challenges: resiliency.

61 RADIATION PROTECTION AND DOSIMETRY↗

Case Study: Applying the Idaho National Laboratory Resilience Framework to St. Mary’s, Alaska

The Idaho National Laboratory (INL) resilience framework has been developed to broadly apply to EEDS so that all elements of systems that contain distributed wind can be part of the resilience evaluation. The users or audience for this framework can include any stakeholders associated with the EEDS. Not all electrical energy systems have the same stakeholders; customers, owners, and operators are generally present but have different interests. Considering the broad electrical grid, customers, regulators, investors, utility planners, engineers, and operators each have an interest in system resilience driven from different motivating factors. This document focuses on the planning stage of the framework. In this document, each step is explained briefly before demonstrating its application to the St. Mary’s-Mt. Village system. The framework can be used for many types of resilience planning. It can be used to evaluate current overall resilience, or the resilience of certain subsystems. It can be used to explore existing resilience weak points and propose mitigations. It can also be used to evaluate the resilience benefits of a new investment. We use the latter application for this case study. Although the wind turbine in St. Mary’s has already been installed, the resilience benefits that the turbine provided were not well defined. It was installed with the main objective to generate electric power from a renewable resource in an effort to reduce the local dependency on fuel oil as the sole source of electric power generation, which is a resilience goal on its own, but there are other ways in which the turbine can add resilience to the system, as well as scenarios of interest to analyze how resilient the wind turbine itself is against different hazards. In this case study, we analyze the operation of the St. Mary’s power system both with the wind installed and without the wind installed during different resilience hazards of interest. This allows us to compare the performance with wind and without wind and to quantify the resilience benefits provided by wind. Our MIRACL partners at PNNL will then take the resilience benefits and assign value to the resilience provided by wind based on costs and costs avoided in the different scenarios.

17 WIND ENERGY↗

Community Resilience Options: A Menu for Enhancing Local Energy Resilience

This document highlights areas of potential community resilience improvements, especially those that relate to clean energy deployment for communities and municipalities. The National Renewable Energy Laboratory (NREL) defines resilience as "a system's ability to anticipate, prepare for, and adapt to changing conditions and withstand, respond to, and recover rapidly from disruptions through sustainable, adaptable, and holistic planning and technical solutions." This document introduces 10 categories of resilience-enhancing projects at a high level, intended for community members and decision-makers new to the topic to build their understanding of which solutions fit their community best. These categories focus primarily on community-scale measures and different options may be available at larger scales. Full implementation of the measures described here requires in-depth, site-specific considerations that go beyond the scope of this document.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Designing resilient decentralized energy systems: The importance of modeling extreme events and long-duration power outages

Mitigating and adapting to climate change requires decarbonizing electricity while ensuring resilience of supply, since a warming planet will lead to greater extremes in weather and, plausibly, in power outages. Although it is well known that long-duration outages severely impact economies, such outages are usually not well characterized or modeled in grid infrastructure planning tools. Here, we bring together data and modeling techniques and show how they can be used to characterize and model long-duration outages. We illustrate how to integrate outages in planning tools for one promising mode of resilient energy supply—microgrids. Failing to treat these extremes in models can lead to microgrid designs (1) that do not realize their full value of resilience, since models do not see the benefits of protecting against extremes, and (2) that appear reliable on paper yet do not actually protect against extremes. Although utilities record power interruptions, lack of access to that data is hindering research on resilience; making datasets available publicly would substantially aid efforts to improve grid planning tools.

24 POWER TRANSMISSION AND DISTRIBUTION↗

FY2021 Isolated Grids and Grid-Connected Turbine Reference Systems

For individuals, businesses, and communities focused on building resilient electrical grid infrastructure, wind energy can provide an affordable, accessible, and compatible distributed energy resource option that also enhances the capabilities of local grid operations. However, there are technical barriers to realizing the market value and resilience benefits of distributed wind, and there is little to no ability to quantify those benefits so that stakeholders can compare grid investment options. The central aims of this report are: (1) to drive technology transfer of the methods and technologies developed under the Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL) project and (2) increase the number of referenceable case studies available to stakeholders interested in additional value-added capabilities of wind systems beyond bulk energy supply. We achieve this aim by applying three major methods developed under MIRACL to two real-world distributed wind reference systems. The two real-world distributed wind reference systems are the isolated grid of St. Mary’s, Alaska, and the two 10.5-megawatt (MW) front-of-the-meter wind turbine deployments owned and operated by Iowa Lakes Electric Cooperative (ILEC).

17 WIND ENERGY↗

Advancing Federal Infrastructure Through Innovation: Customer Damage Function Calculator

Provides an overview of the National Renewable Energy Laboratory (NREL) Customer Damage Function (CDF) Calculator web tool, developed with funding and support from the Federal Energy Management Program (FEMP). The CDF Calculator is a screening tool that provides justification to site and/or headquarters leadership for resilience investments. It generates monetary values to justify investments in resilience solutions to prevent or lessen the impact of a grid outage at a facility.

CDF calculator↗

Power Distribution Designing For Resilience Application

The number of power outages have been on the rise as extreme weather patterns have been occurring more frequently due to climate change. These outages have an economic impact in the billions of dollar. The modernization of the power grid and adoption of high penetration of distributed generation such as wind and solar have the potential to reduce the number and length of time of these power outages. However, planners and operators need a way to value the resilience the distributed assets provide to the grid. PowDDeR is a tool that allows them to evaluate the resilience each asset provides as well as how they provide resilience over the connected network.

Phillips, TylerB↗

Understanding the Value of Energy Storage for Power System Reliability and Resilience Applications

Abstract Purpose of Review The need for energy storage in the electrical grid has grown in recent years in response to a reduced reliance on fossil fuel baseload power, added intermittent renewable investment, and expanded adoption of distributed energy resources. While the methods and models for valuing storage use cases have advanced significantly in recent years, the value of enhanced resilience remains an open research question. Recent Findings The findings of the recent research indicate that energy storage provides significant value to the grid, with median benefit values for specific use cases ranging from under $10/kW-year for voltage support to roughly $100/kW-year for capacity and frequency regulation services. While the value of lost load is used widely to estimate the benefits of mitigating short-duration outages, reaching as high as $719/kilowatt-year, there is no consensus when it comes to monetizing the value of improving grid resilience. Summary This paper presents a use case taxonomy for energy storage and uses the taxonomy to conduct a meta-analysis of an extensive set of energy storage valuation studies. It reviews several approaches for monetizing reliability and resiliency services and presents a proposed approach for valuing resiliency for energy storage investments.

25 ENERGY STORAGE↗

The Role of Innovation in the Circularity of EV Lithium-Ion Batteries

This case study analysis highlights the role of innovations in EV battery design (cells, modules, and packs), reverse supply chain, and recycling processes in yielding value for the economics of recycling (and have the largest impact on the circularity of LIBs). Part of the assessment of value will be a semi-quantitative evaluation of the value of resilience in the rapidly evolving LIB market – i.e., there are a variety of risks that recyclers would face in making a financial commitment to a recycling facility including; the possibility that batteries would not be collected in sufficient quantities, the market for key constituents (e.g., cobalt) might decrease because of changes in battery chemistry, battery manufacturers may not be willing to pay as much for recycled material, etc. The analysis would be semi-quantitative in that two simple models would be used to assess 1. material flows using a previously developed excel-based reverse supply chain flows model, and 2. A LIB recycling process material and energy balance cost model that will be used to qualitatively assess the cost impacts of process innovations and changes in feed streams. Both sets of models are highly speculative in that they rely on a multitude of assumptions and input values (e.g., EV adoption rates) that vary widely in the literature. Additionally, the initial process flow diagrams and equipment lists for the recycling cost model are based on the Argonne EverBatt model, which is still under development. However, in combination with a critical review of the literature, economic modeling can yield valuable insights into the role of innovation in the circularity of LIBs and high-technology (“energy relevant”) products in general.

28 EE - Advanced Manufacturing Office (EE-5A)↗