Effect of argon gas flow rate on properties of film electrodes prepared by thermal vacuum evaporation from synthesized Cu{sub 2}SnSe{sub 3} source

This work describes a new technique to enhance photoresponse of metal chalcogenide-based semiconductor film electrodes deposited by thermal vacuum evaporation under argon gas flow from synthesized Cu{sub 2}SnSe{sub 3} sources. SnSe formation with Cu-doped was obtained under higher argon gas flow rate (V{sub A} = 25 cm{sup 3}/min). Higher value of photoresponse was observed for films deposited under V{sub A} = 25 cm{sup 3}/min which was 9.1%. This finding indicates that Cu atoms inside the SnSe film were important to increase carrier concentrations that promote higher photoresponse.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ultrahigh vacuum gauge having two collector electrodes

A gauge for measuring ultrahigh vacuums with great accuracy is described. It provides a means for ionizing the gas whose pressure is being measured, and consists of a collector electrode, a suppressor, radiation shielding, and a second collector.

Torney, F. L., Jr.↗

Vacuum-free laminated top electrode with conductive tapes for scalable manufacturing of efficient perovskite solar cells

The efficiency of organometal trihalide perovskites (OTP) solar cells have reached that parity of single crystal silicon, and its nature abundant raw material and solution-process capability promise a bright future for commercialization. However, the vacuum based techniques for metal electrode deposition and additional encapsulation layer increase the cost of the perovskite solar cells dramatically and impede their commercialization process. Here, we report a vacuum-free low temperature lamination technique to fabricate the top electrode by commercial conductive tapes (C-tape). The simple fabrication method yields good quality contact and high efficiency device of 12.7%. The C-tapes also encapsulated the devices effectively, resulting in greatly improved device stability. As a result, the combination of lamination of electrodes and encapsulation layers into a single step significantly reduce the cost of device fabrication.

14 SOLAR ENERGY↗

Comparison of pitting fatigue life of ausforged and standard forged AISI M-50 and AISI 9310 spur gears

Standard forged and ausforged spur gears made of vacuum-induction-melted, consumable-electrode, vacuum-arc-remelted AISI M-50 steel were tested under conditions that produced fatigue pitting. The gears were 8.89 cm (3.5 in.) in pitch diameter and had tip relief. The M-50 standard forged and ausforged test results were compared with each other. They were then compared with results for machined vacuum-arc-remelted AISI 9310 gears tested under identical conditions. Both types of M-50 gears had lives approximately five times that of the 9310 gears. The life at which 10 percent of the M-50 ausforged gears failed was slightly less than that at which the M-50 standard forged gears failed. The ausforged gears had a slightly greater tendency to fail by tooth fracture than did the standard forged gears, most likely because of the better forging and grain flow pattern of standard forged gears.

Townsend, D. P.↗

Transparency of graphene for low-energy electrons measured in a vacuum-triode setup

Graphene, being an atomically thin conducting sheet, is a candidate material for gate electrodes in vacuum electronic devices, as it may be traversed by low-energy electrons. The transparency of graphene to electrons with energies between 2 and 40 eV has been measured by using an optimized vacuum-triode setup. The measured graphene transparency equals ∼60% in most of this energy range. Based on these results, nano-patterned sheets of graphene or of related two-dimensional materials are proposed as gate electrodes for ambipolar vacuum devices.

36 MATERIALS SCIENCE↗

Enhanced vacuum arc vapor deposition electrode

A process for forming a thin metal coating on a substrate wherein a gas stream heated by an electrical current impinges on a metallic target in a vacuum chamber to form a molten pool of the metal and then vaporize a portion of the pool, with the source of the heated gas stream being on one side of the target and the substrate being on the other side of the target such that most of the metallic vapor from the target is directed at the substrate.

Weeks, Jack L.↗

A Life Study of Ausforged, Standard Forged and Standard Machined AISI M-50 Spur Gears

Tests were conducted at 350 K (170 F) with three groups of 8.9 cm (3.5 in.) pitch diameter spur gears made of vacuum induction melted (VIM) consumable-electrode vacuum-arc melted (VAR), AISI M-50 steel and one group of vacuum-arc remelted (VAR) AISI 9310 steel. The pitting fatigue life of the standard forged and ausforged gears was approximately five times that of the VAR AISI 9310 gears and ten times that of the bending fatigue life of the standard machined VIM-VAR AISI M-50 gears run under identical conditions. There was a slight decrease in the 10-percent life of the ausforged gears from that for the standard forged gears, but the difference is not statistically significant. The standard machined gears failed primarily by gear tooth fracture while the forged and ausforged VIM-VAR AISI M-50 and the VAR AISI 9310 gears failed primarily by surface pitting fatigue. The ausforged gears had a slightly greater tendency to fail by tooth fracture than the standard forged gears.

Townsend, D. P.↗

Inverted Geometry Ceramic Insulators in High Voltage DC Electron Guns for Accelerators

A direct current (dc) high voltage photo-emission electron gun operating at 130 kV is utilized at the Jefferson Lab (JLab) Continuous Electron Beam Accelerator Facility to generate spin-polarized electrons for nuclear physics experiments. Over the past decade, JLab has tested and implemented inverted-geometry ceramic insulators in photoguns, connecting the cathode electrode in vacuum to the high voltage power supply using commercial high voltage cables. This contribution reports on tests performed up to 375 kV dc, implementation of inverted insulators in a 300 kV dc photogun generating magnetized electron beams, and describes plans to develop a reliable insulator-cable connector for applying 500 kV dc to a future polarized beam photogun operating reliably and without field emission at 350 kV.

Hernandez-Garcia, C.↗

Sheath expansion and plasma dynamics in the presence of electrode evaporation: Application to a vacuum circuit breaker

During the postarc dielectric recovery phase in a vacuum circuit breaker, a cathode sheath forms and expels the plasma from the electrode gap. The success or failure of current breaking depends on how efficiently the plasma is expelled from the electrode gap. The sheath expansion in the postarc phase can be compared to sheath expansion in plasma immersion ion implantation except that collisions between charged particles and atoms generated by electrode evaporation may become important in a vacuum circuit breaker. In this paper, we show that electrode evaporation plays a significant role in the dynamics of the sheath expansion in this context not only because charged particle transport is no longer collisionless but also because the neutral flow due to evaporation and temperature gradients may push the plasma toward one of the electrodes. Using a hybrid model of the nonequilibrium postarc plasma and cathode sheath coupled with a direct simulation Monte Carlo method to describe collisions between heavy species, we present a parametric study of the sheath and plasma dynamics and of the time needed for the sheath to expel the plasma from the gap for different values of plasma density and electrode temperatures at the beginning of the postarc phase. This work constitutes a preliminary step toward understanding and quantifying the risk of current breaking failure of a vacuum arc.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Vacuum Arc Vapor Deposition Method and Apparatus for Applying Identification Symbols to Substrates

An apparatus for applying permanent markings onto products using a Vacuum Arc Vapor Deposition (VAVD) marker by accelerating atoms or molecules from a vaporization source onto a substrate to form human and/or machine-readable part identification marking that can be detected optically or via a sensing device like x-ray, thermal imaging, ultrasound, magneto-optic, micro-power impulse radar, capacitance, or other similar sensing means. The apparatus includes a housing with a nozzle having a marking end. A chamber having an electrode, a vacuum port and a charge is located within the housing. The charge is activated by the electrode in a vacuum environment and deposited onto a substrate at the marking end of the nozzle. The apparatus may be a hand-held device or be disconnected from the handle and mounted to a robot or fixed station.

Harry F Schramm↗

Visual and Electrical Evidence Supporting a Two-Plasma Mechanism of Vacuum Breakdown Initiation

The energy available during vacuum breakdown between copper electrodes at high vacuum was limited using resistors in series with the vacuum gap and arresting diodes. Surviving features observed with SEM in postmortem samples were tentatively correlated with electrical signals captured during breakdown using a Rogowski coil and a high-voltage probe. The visual and electrical evidence is consistent with the qualitative model of vacuum breakdown by unipolar arc formation by Schwirzke [1, 2]. The evidence paints a picture of two plasmas of different composition and scale being created during vacuum breakdown: an initial plasma made of degassed material from the metal surface, ignites a plasma made up of the electrode material.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Influence of the electrode system on the emission characteristics of a vacuum spark

The influence of the electrode system on the emission characteristics of a high-current low-inductance vacuum spark is investigated. It is shown that the structure and composition of the spark plasma radiating in the X-ray spectral range depend substantially on the geometry and relative position of the electrodes. A mechanism related to the effect of the initial distribution of the electric field in the electrode gap is proposed to explain such a dependence. The conditions in which the radiating plasma forms from the erosion products of one or both electrodes are determined.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Transition voltages of vacuum-spaced and molecular junctions with Ag and Pt electrodes

The transition voltage of vacuum-spaced and molecular junctions constructed with Ag and Pt electrodes is investigated by non-equilibrium Green's function formalism combined with density functional theory. Our calculations show that, similarly to the case of Au-vacuum-Au previously studied, the transition voltages of Ag and Pt metal-vacuum-metal junctions with atomic protrusions on the electrode surface are determined by the local density of states of the p-type atomic orbitals of the protrusion. Since the energy position of the Pt 6p atomic orbitals is higher than that of the 5p/6p of Ag and Au, the transition voltage of Pt-vacuum-Pt junctions is larger than that of both Ag-vacuum-Ag and Au-vacuum-Au junctions. When one moves to analyzing asymmetric molecular junctions constructed with biphenyl thiol as central molecule, then the transition voltage is found to depend on the specific bonding site for the sulfur atom in the thiol group. In particular agreement with experiments, where the largest transition voltage is found for Ag and the smallest for Pt, is obtained when one assumes S binding at the hollow-bridge site on the Ag/Au(111) surface and at the adatom site on the Pt(111) one. This demonstrates the critical role played by the linker-electrode binding geometry in determining the transition voltage of devices made of conjugated thiol molecules.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Study of the contributions of the electrode materials to the plasma of a high-current vacuum spark

The contribution of the electrode material to the formation of the plasma of a low-inductive high-current vacuum spark and its influence on the process of discharge micropinching were studied using X-ray spectroscopy and laser diagnostics. Electrode system configurations are determined in which the contributions of the materials of both electrodes to the plasma emitting X-rays are comparable and in which the contribution of one electrode is dominating. It is found that discharge pinching occurs primarily in the vapor of the pointed electrode independently of its polarity. The experimental results indicate the formation of a suprathermal electron beam in the micropinch region.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of Si Content in Electrode and SiO2 Additions to the Slag during Electroslag Remelting

Evolution of Si concentration in 316 stainless steel electrodes was observed during a melting campaign consisting of recycling electroslag remelted (ESR) ingots to make new electrodes using vacuum induction melting (VIM). This campaign consisted of iterations of VIM + ESR operations to optimize melting parameters. The effect of Si content on the melt parameters and ingot quality was further evaluated and additions of SiO2 to the slag chemistry were studied using research-scale experiments, x-ray diffraction (XRF), combustion analysis, visual inspections, and computational tools. The Si concentration was found to decrease by approximately 600 ppm following ESR of 150 lb. research-scale electrodes. Eventually, this led to failure of the slag skin and direct ingot/crucible contact. Additions of SiO2 to the slag at levels matching the original calculated Si concentration in the electrode did not eliminate the slag skin failure and the current during steady state increased to maintain a constant melt rate. In this investigation, we propose a mechanism of slag skin failure consisting of local concentration of current density due to absence, or breakage, of the SiO2 layer around the molten metal drop during ESR. This theory was reinforced by additional experiments in which Nb was added to the electrode to change the structure of the oxide layer around the drops.

Jablonski, Paul↗