Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “utility rates”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Lithium vanadium oxide (Li 1.1 V 3 O 8 ) thick porous electrodes with high rate capacity: utilization and evolution upon extended cycling elucidated via operando energy dispersive X-ray diffraction and continuum simulation

The phase distribution of lithiated LVO in thick (~500 μm) porous electrodes (TPEs) designed to facilitate both ion and electron transport was determined using synchrotron-based operando energy dispersive X-ray diffraction (EDXRD). Probing 3 positions in the TPE while cycling at a 1C rate revealed a homogeneous phase transition across the thickness of the electrode at the 1st and 95th cycles. Additionally, continuum modelling indicated uniform lithiation across the TPE in agreement with the EDXRD results and ascribed decreasing accessible active material to be the cause of loss in delivered capacity between the 1st and 95th cycles. The model was supported by the observation of significant particle fracture by SEM consistent with loss of electrical contact. Overall, the combination of operando EDXRD, continuum modeling, and ex situ measurements enabled a deeper understanding of lithium vanadium oxide transport properties under high rate extended cycling within a thick highly porous electrode architecture.

25 ENERGY STORAGE↗

Analysis of predicted mean vote-based model predictive control for residential HVAC systems

Model Predictive Control (MPC) is an advanced process control method that has attracted much attention in building heating, ventilation, and air conditioning (HVAC) systems. Here, this paper analyzes the optimal precooling performance in residential buildings using MPC with two different comfort indices, namely, temperature and predicted mean vote (PMV). It first formulates, for each comfort index, an optimization problem that accounts for different factors, such as weather, home thermal condition, prediction horizon, time-of use (TOU) utility rate, and rated cooling capacity. The problem is then solved, resulting in an MPC strategy that determines the HVAC on/off control signal and minimizes energy cost over a receding time horizon while maintaining thermal comfort. The energy performance difference between temperature-based and PMV-based MPC strategies is subsequently investigated, especially in light of the interior wall surface temperature and under different combinations of the factors. Extensive simulation results demonstrated that the proposed MPC strategies are adaptive and their performances depend primarily on weather, home thermal condition, and prediction horizon, while the impact of TOU utility rate and rated cooling capacity is relatively small. Because the PMV-based MPC strategy can take advantage of the lower interior wall surface temperature due to precooling, it resulted in 8–45% cost savings for the scenarios investigated and an average increase of 0.042–0.113 in the absolute value of the PMV index compared to the temperature-based MPC strategy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of precooling optimization for residential buildings

To reduce peak demand and/or energy cost for residential buildings, optimal precooling strategies are becoming important as an alternative to rule-based precooling strategies that are intuitive but may not be optimal. Since precooling optimization is heavily dependent on a variety of factors such as the home thermal properties, HVAC system, weather, thermal comfort criteria, and utility rate structure, the individual and collective impact of these factors on precooling performance needs to be analyzed. In addition, since the indoor air temperature is affected by heat transfer to and from the interior wall surface, performance analysis in view of the interior wall surface temperature is also essential. Therefore, in this paper, an optimal precooling strategy that accounts for the aforementioned factors and utilizes a second-order thermal network model, is proposed. With this strategy, the HVAC on/off control signal that minimizes 24-hour energy cost while maintaining thermal comfort, is determined. Through extensive simulations, it is found that the proposed optimal precooling strategy is able to adapt to changing conditions and that having a sufficiently low interior wall surface temperature during precooling is critical for avoiding expensive on-peak operation. Here, the reason for the latter is that such a temperature indicates that enough “cooling energy” has been stored. It is also found that weather has the most dominant impact on the precooling performance, followed by home thermal condition, with the rated cooling capacity and utility rate structure having the least impact.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The cost savings potential of controlling solar thermal collectors with storage for time-of-use electricity rates

Homes and commercial buildings account for roughly 40% of U.S. energy consumption. A significant portion of this energy consumption, and therefore utility cost, comes from domestic hot-water use. Solar collectors such as flat plate collectors, evacuated tubes, and combined photovoltaic/thermal panels, are renewable options that collect thermal energy and could help reduce utility costs. Hot water is generated by pumping a working fluid through the solar collector, where the fluid captures thermal energy via absorbed solar radiation incident on the collector surface. The collection of heat coincides with the availability of solar radiation, but the best time to use this thermal energy depends on the utility rate at a given time, which often changes throughout the day. In this work, we implement and simulate a control strategy using Transient System Simulation Tool (TRNSYS) that reduces utility costs by controlling when the system stores and uses thermal energy based on solar availability and time-of-use electricity rates. Our modeled results show that the control strategy can reduce utility costs associated with using hot water between 3% and 30%. Here, we also show how the on-peak utility rates, the size and type of the solar collectors, and the location's climate impact the results.

14 SOLAR ENERGY↗

Fast Charging Infrastructure for Electrifying Road Trips to and from National Parks in the Western United States

National parks in the Western United States draw over 80 million visitors every year, and most visitors rely on personal cars for their road trips (or long-distance travels). Travel to national parks represents distinct travel demand, as they are typically located in remote areas necessitating long-distance trips. This study investigates the quantity and locations of on-route fast charging infrastructure needed by 2030 to enable seamless travel to/from national parks using electric vehicles in seven target states in the region, employing unprecedented high-resolution spatial and temporal analysis. We find that the required number of fast charging ports for on-route charging infrastructure ranges from 1,200 to 22,000, depending on different assumptions of key input parameters - vehicle electrification rate, charging behavior, average gap between charging stations, port utilization rate, and towing trailers. Our analysis also indicates that electrical load for on-route fast charging infrastructure would peak in the afternoon, in the range of 70-400 MW, varying with the key input parameters. This study illustrates how different input parameters result in different degrees of impact on various aspects of charging infrastructure. We also examine the characteristics of projected charging infrastructure in terms of land use type, relationship with traffic volume, size of stations, and other variables.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Rapid estimation of photosynthetic leaf traits of tropical plants in diverse environmental conditions using reflectance spectroscopy

Tropical forests are one of the main carbon sinks on Earth, but the magnitude of CO 2 absorbed by tropical vegetation remains uncertain. Terrestrial biosphere models (TBMs) are commonly used to estimate the CO 2 absorbed by forests, but their performance is highly sensitive to the parameterization of processes that control leaf-level CO 2 exchange. Direct measurements of leaf respiratory and photosynthetic traits that determine vegetation CO 2 fluxes are critical, but traditional approaches are time-consuming. Reflectance spectroscopy can be a viable alternative for the estimation of these traits and, because data collection is markedly quicker than traditional gas exchange, the approach can enable the rapid assembly of large datasets. However, the application of spectroscopy to estimate photosynthetic traits across a wide range of tropical species, leaf ages and light environments has not been extensively studied. Here, we used leaf reflectance spectroscopy together with partial least-squares regression (PLSR) modeling to estimate leaf respiration ( R dark25 ), the maximum rate of carboxylation by the enzyme Rubisco ( V cmax25 ), the maximum rate of electron transport ( J max25 ), and the triose phosphate utilization rate ( T p25 ), all normalized to 25°C. We collected data from three tropical forest sites and included leaves from fifty-three species sampled at different leaf phenological stages and different leaf light environments. Our resulting spectra-trait models validated on randomly sampled data showed good predictive performance for V cmax25 , J max25 , T p25 and R dark25 (RMSE of 13, 20, 1.5 and 0.3 μmol m -2 s -1 , and R 2 of 0.74, 0.73, 0.64 and 0.58, respectively). The models showed similar performance when applied to leaves of species not included in the training dataset, illustrating that the approach is robust for capturing the main axes of trait variation in tropical species. We discuss the utility of the spectra-trait and traditional gas exchange approaches for enhancing tropical plant trait studies and improving the parameterization of TBMs.

54 ENVIRONMENTAL SCIENCES↗

Tolerance of engineered Rhodosporidium toruloides to sorghum hydrolysates during batch and fed-batch lipid production

Abstract Background Oleaginous yeasts are a promising candidate for the sustainable conversion of lignocellulosic feedstocks into fuels and chemicals, but their growth on these substrates can be inhibited as a result of upstream pretreatment and enzymatic hydrolysis conditions. Previous studies indicate a high citrate buffer concentration during hydrolysis inhibits downstream cell growth and ethanol fermentation in Saccharomyces cerevisiae . In this study, an engineered Rhodosporidium toruloides strain with enhanced lipid accumulation was grown on sorghum hydrolysate with high and low citrate buffer concentrations. Results Both hydrolysis conditions resulted in similar sugar recovery rates and concentrations. No significant differences in cell growth, sugar utilization rates, or lipid production rates were observed between the two citrate buffer conditions during batch fermentation of R. toruloides . Under fed-batch growth on low-citrate hydrolysate a lipid titer of 16.7 g/L was obtained. Conclusions Citrate buffer was not found to inhibit growth or lipid production in this engineered R. toruloides strain, nor did reducing the citrate buffer concentration negatively affect sugar yields in the hydrolysate. As this process is scaled-up, $131 per ton of hydrothermally pretreated biomass can be saved by use of the lower citrate buffer concentration during enzymatic hydrolysis. Graphical Abstract

09 BIOMASS FUELS↗

Data for Tolerance of Engineered Rhodosporidium toruloides to Sorghum Hydrolysates During Batch and Fed-Batch Lipid Production

Oleaginous yeasts are a promising candidate for the sustainable conversion of lignocellulosic feedstocks into fuels and chemicals, but their growth on these substrates can be inhibited as a result of upstream pretreatment and enzymatic hydrolysis conditions. Previous studies indicate a high citrate buffer concentration during hydrolysis inhibits downstream cell growth and ethanol fermentation in Saccharomyces cerevisiae . In this study, an engineered Rhodosporidium toruloides strain with enhanced lipid accumulation was grown on sorghum hydrolysate with high and low citrate buffer concentrations. Both hydrolysis conditions resulted in similar sugar recovery rates and concentrations. No significant differences in cell growth, sugar utilization rates, or lipid production rates were observed between the two citrate buffer conditions during batch fermentation of R. toruloides . Under fed-batch growth on low-citrate hydrolysate a lipid titer of 16.7 g/L was obtained. Citrate buffer was not found to inhibit growth or lipid production in this engineered R. toruloides strain, nor did reducing the citrate buffer concentration negatively affect sugar yields in the hydrolysate. As this process is scaled-up, $131 per ton of hydrothermally pretreated biomass can be saved by use of the lower citrate buffer concentration during enzymatic hydrolysis.

Conversion↗

Application of thermal energy storage with electrified heating and cooling in a cold climate

Ground source heat pumps (GSHPs) have been shown to be an effective means of decarbonizing building heating and cooling, but the operation of these systems at scale presents challenges to sites and the grid due to increases in peak demand. Here, in this study, we investigate how the use of Thermal Energy Storage (TES), in the form of stratified water storage, could reduce the peak daily demand associated with GSHP systems and thus improve their cost effectiveness. This system was compared to a Combined Heat and Power (CHP) plant, to investigate the potential cost and emissions impacts of electrification on large energy users transitioning from high efficiency fossil fuel equipment. This study builds on previous research by using a significant campus area, and investigating the various impacts of an electrified system versus a state of the art fossil fuel system. An established method of TRNSYS modeling is used for the heat pumps and borehole heat exchangers (BHEs), along with the TES. The GSHP system with TES is modeled to follow industry standards and sized to provide an optimal balance of capital and operating costs. Costs were investigated for a unique large energy user rate structure, as well as for a more common generalized rate structure. The results show that the addition of TES to the GSHP system could reduce operating costs by 4.5%, but still incurs a 5.64% cost increase from the baseline CHP system. It is also shown, however, that a tactical integration of heat pumps into the CHP system is the most cost effective solution, only increasing the operating costs by 4.71%. Likewise, the impacts of different rate structures are highlighted, with the TES only resulting in 0.75% cost savings under the generalized utility rate. Furthermore, it is shown that thermal storage has great potential for demand reduction, with the addition of storage incurring a decrease of 7–22% in annual peak demand kW, dependent on the rate structure.

25 ENERGY STORAGE↗

Large-scale simulation-based parametric analysis of an optimal precooling strategy for demand flexibility in a commercial office building

Achieving success with grid-interactive efficient buildings (GEBs) is closely tied to the utilization of flexible loads. A valuable strategy involves the implementation of precooling techniques before high-demand events, such as peak hours, by adjusting zone air temperature setpoints. This leads to a reduction in thermal loads and peak electricity demand during these times, as the building’s thermal mass stores and subsequently releases thermal energy. However, the effectiveness of the pre-cooling optimization is highly contingent on specific conditions such as building thermal properties, weather conditions, utility rate structure, HVAC equipment sizing, etc. Therefore, investigating the impacts of these condition-specific factors is crucial, especially when considering precooling strategies that utilize thermal mass in commercial buildings. In this paper, we first devised a novel heuristic control approach that incorporates parameterized optimal precooling thermostat schedules to enhance demand flexibility in a commercial office building. Subsequently, we conducted a thorough performance evaluation of this control strategy. Here, the optimal thermostat schedule was parameterized using three optimization variables: the precooling start time, the precooling end time, and the precooling temperature setpoint. Utilizing the DOE medium-sized office building as the virtual testbed, we showed that the parameterized schedule effectively approximates model predictive control and requires drastically reduced computational overhead. In addition, we investigated the impact of different influencing factors on the optimal precooling strategy. These factors include building thermal mass, outdoor air conditions, and energy price profiles. Using high-performance computing, we simulated a total of 225 scenarios, consisting of three levels of thermal mass, five typical outdoor air temperature profiles, and fifteen time-of-use price plans. The results demonstrate that optimal thermostat scheduling could save substantial energy cost in medium-sized office buildings with heavy thermal mass but with some energy penalty. Although the potential for cost savings is lower in buildings with low and medium thermal mass, the energy penalty remains consistent in all three thermal mass scenarios. The study also highlights the need to account for zone diversity and recognize that a one-size-fits-all-zone setpoint schedule may not be suitable for all zones and can lead to unnecessary energy wastage. Furthermore, the results highlight that while outdoor air conditions play a role in cost and energy performance, the cooling load exerts a more immediate and substantial influence on cost savings in precooling strategies. Although cost savings are comparable under certain conditions with the same cooling load, observed deviations in energy penalty indicate potential disparities in the efficiency of the HVAC system during the load-shifting process. In addition, the duration of peak pricing and the ratio between peak and off-peak times exhibit clear correlations with cost savings and energy consumption, aligning with intuitive expectations. These findings offer valuable insights for optimizing precooling strategies in office buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Revenue-Maximizing Shared Parking and Electric Vehicle Charging Management in Multi-Unit Dwellings

In urban areas, searching for parking and electric vehicle (EV) charging can result in cruising, congestion, and environmental externalities. Recognizing the business opportunity of offering private parking and charging infrastructure access within multi-unit dwellings (MUDs) during daytime, we model a shared parking and EV charging management system. We maximize the revenue of MUD charging hubs in mixed land use, catering to public demand. Our approach accounts for the objectives of the two stakeholders involved: a demand model is fitted on the choices of EV charging users, and the supply model optimizes the allocation of parking and charging requests in an MUD parking lot. A binary integer linear programming model for the allocation of parking and charging spaces with a rolling horizon is integrated with matching rules that handle both parking and charging requests. In our numerical experiments in a neighborhood of Chicago, Illinois, we estimate the performance of the MUD parking and charging system with metrics that include revenue, number of matchings, and utilization rates. At any given time, MUDs with lower prices attract more charging requests, particularly those of longer duration, resulting in higher revenue and greater charging utilization. Dynamic pricing facilitates a more equitable distribution of requests; as MUD parking lots reach capacity and their fees increase, other MUDs become more competitive, attracting additional requests. Comparing our method against first-come-first-served and optimal-solution benchmarks, we demonstrate our model’s effectiveness in dynamically managing mixed parking and charging demand in MUD charging hubs.

electric vehicle, multi-unit dwelling, charging in↗

Techno-Economic Analysis for the Addition of a Thermal Energy Storage System to a Central Plant

Increasing energy demand and rising peak loads present significant challenges for energy management in commercial and institutional settings. As climate change drives greater cooling needs, central plants must navigate the complex tradeoffs between operational efficiency, cost control, and grid stability. Thermal energy storage (TES) systems offer a viable solution by shifting energy consumption from peak to off-peak periods, thereby reducing peak demand, lowering utility expenses, and improving grid resilience. However, the success of TES implementation hinges on appropriate system sizing, effective control strategies, and alignment with local utility rate structures. This article presents a techno-economic analysis of integrating a chilled water TES system into the central plant at California State University, Dominguez Hills. Drawing on historical load profiles and utility tariffs, we assess three TES sizing approaches and their corresponding control strategies from both energy and economic perspectives. This article utilizes a model-based approach to assess the impact of TES sizing and control strategies on the techno-economic feasibility of integrating TES into an existing central plant. The models employed for this analysis were calibrated using 4 years of historical data. Here, the results demonstrated that utility tariffs and the campus's operational profiles dictate the most feasible sizing and control methods. The findings offer valuable insights for institutions and commercial building managers exploring sustainable energy solutions. By demonstrating how optimized TES strategies can improve operational efficiency while achieving financial savings, this study highlights the potential for TES to align performance with cost effectiveness in real-world applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Probabilistic and maximum entropy modeling of chemical reaction systems: Characteristics and comparisons to mass action kinetic models

We demonstrate and characterize a first-principles approach to modeling the mass action dynamics of metabolism. Starting from a basic definition of entropy expressed as a multinomial probability density using Boltzmann probabilities with standard chemical potentials, we derive and compare the free energy dissipation and the entropy production rates. We express the relation between entropy production and the chemical master equation for modeling metabolism, which unifies chemical kinetics and chemical thermodynamics. Because prediction uncertainty with respect to parameter variability is frequently a concern with mass action models utilizing rate constants, we compare and contrast the maximum entropy model, which has its own set of rate parameters, to a population of standard mass action models in which the rate constants are randomly chosen. We show that a maximum entropy model is characterized by a high probability of free energy dissipation rate and likewise entropy production rate, relative to other models. We then characterize the variability of the maximum entropy model predictions with respect to uncertainties in parameters (standard free energies of formation) and with respect to ionic strengths typically found in a cell.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis of Second Target Station Target Removal Dose Rates

The Second Target Station (STS) project at Oak Ridge National Laboratory’s spallation neutron source is a crucial initiative for maintaining U.S. leadership in neutron sciences. The STS aims to create the world’s brightest pulsed cold neutron source, enabling cutting-edge research across various scientific disciplines. To ensure safe and efficient maintenance operations, understanding the effects of shutdown dose rates from activated components within the STS target systems is essential. This study establishes a computational framework for calculating decay gamma sources and subsequent shutdown dose rates utilizing advanced methods to account for all activation channels, including high-energy interactions down to thermal neutron capture. This study describes a novel integration of multiple tools and provides an effective means of analyzing activation and shutdown dose rates at spallation neutron facilities. A custom-developed script automates the decay gamma source generation process, ensuring proper sampling during the variance reduction phase, which is critical for accurate predictions of shutdown dose rates.

Transmutation↗

Increasing the Number of Installed Residential Heat Pump Water Heaters in the USA Through Improved Technology and Utility Programs

Heat pump water heaters (HPWHs) offer an efficient alternative to electric resistance water heaters, but they suffer from limited market penetration. This paper reviews the current state of HPWHs in the USA, focusing on technology developments and programs to increase adoption. What technological improvements are needed to make HPWHs a good fit in more homes? Additionally, what are the best ways of promoting HPWHs to consumers? Improved communication and controls will allow HPWHs to provide demand response and follow dynamic utility rates. To enable fuel-switching, HPWHs are being developed that only need a standard 120V outlet. Split HPWHs can alleviate the cooling and noise that limit the use of HPWHs in small homes, multifamily buildings, and cold climates. Additionally, new utility programs aim to train installers and provide incentives to distributors to increase the number of HPWHs installed. Some utilities offer novel incentive programs that have led to increased customer uptake. Those advances, coupled with improved controls for load shifting and new products such as split HPWHs and HPWHs that can run on 120V power, may finally move the market forward.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Unveiling a classical mutant in the context of the GH 3 β-glucosidase family in Neurospora crassa

Classical fungal mutant strains obtained by mutagenesis have helped to elucidate fundamental metabolic pathways in the past. In the filamentous fungus Neurospora crassa, the gluc-1 strain was isolated long ago and characterized by its low level of β-glucosidase activity, which is essential for the degradation of cellulose, the most abundant biopolymer on Earth and the main polymeric component of the plant cell wall. Based on genomic resequencing, we hypothesized that the causative mutation resides in the β-glucosidase gene gh3-3 (bgl6, NCU08755). In this work, growth patterns, enzymatic activities and sugar utilization rates were analyzed in several mutant and overexpression strains related to gluc-1 and gh3-3. In addition, different mutants affected in the degradation and transport of cellobiose were analyzed. While overexpression of gh3-3 led to the recovery of β-glucosidase activity in the gluc-1 mutant, as well as normal utilization of cellobiose, the full gene deletion strain Δgh3-3 was found to behave differently than gluc-1 with lower secreted β-glucosidase activity, indicating a dominant role of the amino acid substitution in the point mutated gh3-3 gene of gluc-1. Our results furthermore confirm that GH3-3 is the major extracellular β-glucosidase in N. crassa and demonstrate that the two cellodextrin transporters CDT-1 and CDT-2 are essential for growth on cellobiose when the three main N. crassa β-glucosidases are absent. Overall, these findings provide valuable insight into the mechanisms of cellulose utilization in filamentous fungi, being an essential step in the efficient production of biorefinable sugars from agricultural and forestry plant biomass.

60 APPLIED LIFE SCIENCES↗

Charging Hub Scenario Sheet Screenshot

The Excel-based CHECT tool estimates the LCOC ($/kWh) by charger type (Level 1, Level 2, and DC fast charging) for a given charging hub scenario. CHECT requires users to input certain charging hub scenario parameters, including the number of chargers, daily utilization, and charger replacement frequency by charger type. Additional inputs such as the charging schedule, local utility rates, capital/operational costs, and financial inputs can be customized by the user, or the tool can generate results using appropriate default values from literature for the charging hub scenario and service location(s). Using the above inputs, CHECT performs a robust techno-economic analysis to generate the LCOC by charger type, broken down by cost category (e.g., capital, operational, utility, taxes) for various combinations of charging hub types (multiunit dwelling or public) and ownership models (residential, utility, or private company). It also outputs the annual discounted cash flows and determines the most sensitive input variables. In addition, the tool allows users to easily compare the LCOC across various ownership models or across different states.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Rooftop Solar in Lawrence, MA: Community Perspectives, Deceptive Practices, and Financing Options

This report was prepared as part of the U.S. Department of Energy's Communities Local Energy Action Program (Communities LEAP) pilot competitive technical assistance for the Lawrence Massachusetts Stakeholder Coalition (LSC) composed of The City of Lawrence, All In Energy, MassDevelopment, Mill City Community Investments, BlocPower and Groundwork Lawrence, and led by Browning the Green Space. The LSC identified rooftop solar photovoltaics as a top priority for this technical assistance opportunity. Lawrence faces high energy burden and electricity prices, thus rooftop solar can be a tool to help lower those costs. However, the coalition received feedback that some solar companies were using deceptive and unfair practices when marketing, selling, or financing solar energy, costing residents more money than utility rates and increasing the energy burden. This project sought to address rooftop solar community priorities through two pathways: 1. facilitating community engagement to understand community perspectives and experiences with rooftop solar development; and 2. conducting a financial cash-flow analysis highlighting the varying fiscal outcomes for rooftop solar adopters based off rooftop solar leasing, ownership, or buying electricity from the utility (National Grid).

14 SOLAR ENERGY↗