Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “unbalanced system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Power Flow Models of Grid-Forming Inverters in Unbalanced Distribution Grids

Load unbalance in electric distribution systems is unavoidable. Unbalanced load currents will lead to negative sequence (NS) voltages that may damage electric equipment. Unbalanced power flow analysis is a common tool to detect and mitigate NS voltage issues and requires accurate models of grid components. While traditional source models are available, grid-forming (GFM) inverter models are not well developed. GFM inverters implement various control strategies, which affect their power flow models. Here, in this paper, a novel GFM inverter model considering control effects is proposed. We show that for some control methods, unbalanced system loading will lead to unbalanced terminal voltages of the GFM inverters, which are modeled through an equivalent negative sequence impedance. The proposed models are initially validated using a simple test circuit. Then, they are applied in the power flow analysis on the IEEE 13-bus and 34-bus systems to demonstrate the accuracy improvement over the state-of-the-art. Using time-domain simulations as benchmarks, we show that the proposed models reduce the calculation error of negative sequence voltages by at least 25% in unbalanced distribution systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High rate reactive sputtering in an opposed cathode closed-field unbalanced magnetron sputtering system

Attention is given to an opposed cathode sputtering system constructed with the ability to coat parts with a size up to 15 cm in diameter and 30 cm in length. Initial trials with this system revealed very low substrate bias currents. When the AlNiCo magnets in the two opposed cathodes were arranged in a mirrored configuration, the plasma density at the substrate was low, and the substrate bias current density was less than 1 mA/sq cm. If the magnets were arranged in a closed-field configuration where the field lines from one set of magnets were coupled with the other set, the substrate bias current density was as high as 5.7 mA/sq cm when NdFeB magnets were used. In the closed-field configuration, the substrate bias current density was related to the magnetic field strength between the two cathodes and to the sputtering pressure. Hard well-adhered TiN coatings were reactively sputtered in the opposed cathode system in the closed-field configuration, but the mirrored configuration produced films with poor adhesion because of etching problems and low plasma density at the substrate.

Sproul, William D.↗

A Laplace-Domain Circuit Model for Fault and Stability Analysis Considering Unbalanced Topology

For systems subject to unbalanced faults, analytical model building for stability assessment is a challenging task. This letter presents a straightforward modeling approach. A generalized dynamic circuit representation is achieved by use of the Laplacian transform variable s . Here, we translate the voltage and current relationship at the fault location into the relationship of three subsystems. The final circuit model is an interconnected sequence network with impedances in the Laplace domain. This circuit can be directly converted from a steady-state sequence network. This modeling procedure is illustrated by an example case of an induction motor served by a grid through a series compensated line. Electromagnetic transient simulation results demonstrate that sub-synchronous oscillations can be mitigated when a single-line to ground fault is applied at the motor terminal. Stability analysis results based on the dynamic circuit corroborate the simulation results. What's more, the derived circuit effortlessly reveals why unbalance can enhance stability.

42 ENGINEERING↗

Phasor-Domain Modeling of Inverter Based Resources Considering Unbalanced Grid Faults

A significant increase in inverter-based distributed energy resources (DERs) is expected in distribution systems of the near future. The latest phasor modeling approach of DERs with emerging control technologies can capture relevant dynamics in large-scale three-phase distribution systems with unbalanced construction. However, there is a lack of appropriate phasor models to deal with unbalanced fault scenarios. As such, this paper describes per-phase phasor modeling approach appropriate for unbalanced grid disturbance studies in distribution systems with high penetration of DERs. The overall modeling performance of representative DERs is simulated in phasor domain GridLAB-D environment and validated against controller hardware-in-the loop (CHIL) testing or electromagnetic transient (EMT) based switching model simulation in PSCAD with test cases including different unbalanced grid faults. The high accuracy retained from the simulation verifies the effectiveness of the proposed phasor modeling approach considering interactions between positive and negative sequence signals.

Chen, Zhe↗

Effect of noisy phase reference on coherent detection of unbalanced QPSK signals

A phase error in the reference signal used in coherent detection of PSK signals causes a degradation in performance; this effect on bit error probability has been much discussed in the literature for BPSK and balanced QPSK systems. For unbalanced QPSK (UQPSK) systems, where the power and data rates in the two channels are unequal, and where the channel data symbols might also be different, the problem of computing the error probability is more complex, and only approximate solutions have been previously given. In this paper, exact expressions are derived for the conditional probability of error for the I and Q channels as a function of the channel power and data rate ratio. This is done for all combinations of Manchester and NRZ signalling schemes, and it is shown that in some cases the low data rate channel can be more seriously affected by a phase offset. Numerical results are also given for the average probability of error, assuming a biphase Costas loop is used for carrier synchronization.

Osborne, H. C.↗

GRIDAPPSD/distopf (33583-E)

DistOPF is an open-source Python package providing a three-phase, asymmetric optimal power flow (OPF) tool specifically designed for distribution systems. The key inventive features include: - Asymmetrical 3-phase OPF modeling for distribution systems with unbalanced phases - Comprehensive control optimization supporting both active (P) and reactive (Q) power control variables - Built-in visualization and validation tools - Standard test system benchmarking platform for algorithm development and comparison - Modular CSV-based input system using Pandas DataFrames for flexible model specification - Standard power distribution model importer enabling direct conversion from CIM and OpenDSS format to optimization-ready models - Multiple solve interface compatibility (PYOMO, CVXPY, SciPy) with automatic solver selection based on problem type

Gray, Nathan [Pacific Northwest National Laborator↗

Voltage Violation Prediction in Unobservable Distribution Systems

Recently, distributed energy resources (DERs) such as photovoltaic (PV) systems have garnered significant attention due to their economic and environmental benefits. However, DERs can also pose new technical challenges to distribution system operation including under/over voltage issues. In this regard, voltage violation prediction (VVP) becomes an essential component of system operation as it enables proactive control strategies. Unfortunately, classical voltage monitoring techniques assume full availability of state measurements across all nodes in the system. In real-world scenarios, distribution systems are limited with few measurement devices, rendering the system unobservable. Therefore, this paper proposes a new Bayesian matrix completion (BMC) based VVP technique that accurately predicts the probability of nodal voltage violations in unobservable (and unbalanced) distribution systems. The proposed approach is tested via simulations on the IEEE 37 test system. Results show that the proposed method offers over 90% violation prediction accuracy with as low as 50% fraction of available data.

Abujubbeh, Mohammad↗

Distributed Coordination of Networked Microgrids for Voltage Support in Bulk Power Grids

The increasing deployment of distributed energy resources (DERs) and microgrids (MGs) in power distribution systems has enabled the adjustment of reactive power consumption as seen at the substation, which can be used to provide voltage support for the bulk power system (BPS). Leveraging this new capability will provide greater resiliency to the power system as a whole. Here, the goal of this paper is to develop and compare three different algorithms, namely distributed optimal power flow, distributed consensus algorithm, and fully decentralized collaborative autonomy for unbalanced distribution systems for microgrid coordination. These algorithms use networked MGs to support the BPS voltage when a contingency at the bulk grid results in abnormally low voltages, which may be a precursor to voltage collapse. Our comparative analysis includes both qualitative and quantitative assessments of the three algorithms and a discussion of the trade-offs between the decentralized and distributed methods in normal and disrupted conditions. Each algorithm was evaluated on the modified IEEE 13-bus system and a real power distribution system at Chattanooga, Tennessee, that encompasses more than 4500 buses. Each algorithms excels differently and may be suited for different scenarios depending on the condition, operations, and priorities of the power and communication systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Unbalanced Rotating Masses For Scanning

Unbalanced rotating masses low-cost, low-power, lightweight means of generating scanning torques for scientific instruments. Imparts variety of scanning patterns; continuous circular, back-and-forth linear, and, with aid of indexing mechanism, raster. Scanning rate determined by sizes of moment arms and rotational velocities. System of unbalanced rotating masses proposed for scanning gimbaled sensors that observe Sun from balloon-borne gondola. Two unbalanced masses move sensor aim in circular pattern around center of the Sun.

Polites, Michael E.↗

Safe Deep Reinforcement Learning for Active Distribution System Model Predictive Control with EVs and DERs

The temporal and spatial mismatch between PV generation and electric vehicle (EV) charging and discharging may cause voltage violations in active distribution networks. Despite the widespread use of deep reinforcement learning (DRL) in power system optimization and control, it lacks guarantees on constraint satisfaction during both training and deployment. This paper proposes a Lagrangian-based safe DRL approach for model predictive control (MPC) of active distribution systems with large-scale integration of PVs, EVs, and energy storage systems (ESSs). A Transformer-LSTM time-series model is proposed to forecast EV charging demand, which is then formulated as a constraint to ensure charging requirements are met. Using this prediction, a Lagrangian-based safe soft actor-critic (SAC) framework is developed for real-time control in a three-phase unbalanced distribution system, enforcing voltage safety constraints while optimizing the cumulative net reward. By integrating the forecasting model with multi-period constraints, the proposed framework jointly coordinates PV systems, EV charging and discharging, and ESS scheduling within the MPC horizon. Numerical experiments on a modified IEEE 123-bus system with real-world data show that, under a high PV penetration scenario, the proposed method increases the net reward by 30.74% and reduces average voltage violations from 0.0011 p.u. to 0.0002 p.u. compared with standard SAC. Compared with the optimal power flow (OPF) approach, it achieves similar voltage security while yielding lower line losses. It also maintains real-time control capability, reducing operation latency to 53.21 ms per 15-minute control interval. The proposed method remains effective under varying PV/EV penetrations and load conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Sensitivity-Based Reactive Power Dispatch of DERs to Support Transmission Grid During Emergency

This paper proposes a TSO-DSO framework including DER set-point dispatch using sensitivity analysis. We address all three steps of TSO-DSO integration stating by estimating the capability curve of an unbalanced distribution system and then modeling of capability curve on the transmission side grid and estimating the reactive power needed from DSO during emergencies, and ending by dispatching the requested reactive power from TSO. The proposed interaction framework is tested on an IEEE 37-node distribution network connected to IEEE 9 bus transmission system. The simulation shows that using sensitivity-based dispatch would reduce the number of communication signals between DERs and DSO and that can decrease the risk of communication contingency.

Alkhonain, Ahmed↗

Access Patterns and Performance Behaviors of Multi-layer Supercomputer I/O Subsystems under Production Load

Scientific computing workloads at HPC facilities have been shifting from traditional numerical simulations to AI/ML applications for training and inference while processing and producing ever-increasing amounts of scientific data. To address the growing need for increased storage capacity, lower access latency, and higher bandwidth, emerging technologies such as non-volatile memory are integrated into supercomputer I/O subsystems. With these emerging trends, we need a better understanding of the multilayer supercomputer I/O systems and ways to use these subsystems efficiently. In this work, we study the I/O access patterns and performance characteristics of two representative supercomputer I/O subsystems. Through an extensive analysis of year-long I/O logs on each system, we report new observations in I/O reads and writes, unbalanced use of storage system layers, and new trends in user behaviors at the HPC I/O middleware stack.

Bez, JL↗

Per-phase Phasor Modeling of GFL and GFM Inverters for Distribution System Dynamic Studies

A significant increase in inverter-based distributed energy resources (DERs) is expected in the near future. Existing electromagnetic models and sequential electromechanical models of DERs supporting dynamic analysis cannot be extended to largescale three-phase distribution systems usually with unbalanced construction. As such, there is a need for appropriate industry models that can support distribution system dynamic studies. This paper describes the latest phasor models of grid-following (GFL) and grid-forming (GFM) inverters that can capture distribution system dynamics under grid disturbances. The overall modeling performance is examined and compared with results from other platforms such as controller hardware-in-the-loop (CHIL), MATLAB/Simulink and PSCAD with electromagnetic transient (EMT) and/or phasor simulation capabilities under balanced and unbalanced faults.

Distribution system, Grid modelling, GridLAB-D, Po↗

Computationally Robust Line Outage Detection and Identification in Three-Phase Networks

Detection and identification of individual phase outages remains a challenging problem due to insufficient metering in three-phase unbalanced power networks. This problem was tackled for the transmission systems in our previous work as documented in [1]. In this paper, this work is extended to detect phase outages in three-phase unbalanced systems using only the sparse estimation method. In addition, further improvements are introduced to increase the estimation accuracy for the virtual power injections at the terminal buses of disconnected lines, once the disconnected line is identified by sparse estimation methods. Simulation results are provided to experimentally validate the increased accuracy in detecting phase outages while decreasing the computational time by using the proposed approach.

Sparse Estimation, Line Outage, Phase Outage, LASS↗

Effects of an unbalanced magnetron in a unique dual-cathode, high rate reactive sputtering system

Simple plasma and magnetic field measurements are presented to illustrate the opportunities afforded by using unbalanced magnetrons in a dual-cathode system. The system employs a pair of opposed cathodes, 38 cm x 13 cm, placed 27.5 cm apart, to coat specimens mounted on a rotational substrate holder. Comparisons are drawn between the original 'balanced' magnetron and several unbalanced configurations in terms of field strengths, deposition rates, etching characteristics, and substrate ion current densities for the growth of TiN films. The effects of 'unbalancing' on the nature of the plasma within the 3D geometry of the deposition chamber are elucidated via plasma probe and magnetic field studies performed under a variety of conditions. All the unbalanced configurations examined provided enhanced ion bombardment at the surface of the growing film. The closed-field or opposed magnet geometry resulted in a threefold or greater increase in current density when compared with that obtained using the corresponding mirrored geometry under the same conditions.

Rohde, S. L.↗

Microgrid Modeling for Stability Analysis

Here this document is a summary of a report prepared by the IEEE PES Task Force (TF) on Microgrid (MG) Dynamic Modeling, IEEE Power and Energy Society, Tech. Rep. PES-TR106, 2023. In this paper, the major issues and challenges in microgrid modeling for stability analysis are discussed, and a review of state-of-the-art modeling approaches and trends is presented. In the context of the IEEE 1547 standard, the document covers issues associated with component models for MG dynamic studies and simulations, including generator and grid modeling, full and average converter models, unbalanced and balanced system conditions, dynamic and static loads, protection requirements, and detailed and simplified controls considering communications delays, packet losses, and security issues. Considering the future integration of grids and MGs to form broad integrated networks, a discussion is presented of the use of phasor vis-à-vis electromagnetic transient simulation tools for MG dynamic stability studies, as well as modeling scale-up issues and MG equivalent models. Specifically white-, grey-, and black-box models, are presented. This TF paper and companion report constitute a modeling guide for R&D groups working on developments and standards of MGs with a focus on stability issues.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗