Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ultrasonic testing (UT)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Modeling and Simulation of Austenitic Welds and Coarse-grained Specimens: Part II

The Pacific Northwest National Laboratory (PNNL) is conducting confirmatory research for the U.S. Nuclear Regulatory Commission (NRC) to evaluate commercially available nondestructive examination (NDE) modeling and simulation software used in the nuclear industry. Simulation results from ultrasonic testing (UT) models can inform the design and qualification of inspection techniques and help interpret inspection results. CIVA is a modeling and simulation package developed by the French Alternative Energies and Atomic Energy Commission (CEA). CIVA was selected for this study because it is readily available and has been used for NDE in the US commercial nuclear power industry. This report is focused on completing the efforts initiated in the previous PNNL report to evaluate UT modeling and simulation performance, reliability, and accuracy in relation to common inservice inspection (ISI) scenarios in nuclear power plants (NPP). This work will be used to provide guidance when establishing methods to perform and evaluate simulations for more standardized model implementation, simulation analysis, and interpretation of results.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Evaluation of Flaw Detection with SLDV Methods Before/After Mechanical Patch

This report provides a summary of the testing and the experiments to evaluate the utility of laser ultrasonic testing (UT) in detecting and characterizing defects on the surface of steel plates before and after the application of an engineered composite patch for crack repair. Included are the detection and characterization of defects from a section of welded plate material taken from the Sandia National Laboratories’ full-size mockup of a spent nuclear fuel (SNF) dry storage canister which had been pre-flawed and exposed to deliquescent sea salt conditions for 2 years. The information includes a review of previously reported metallurgical characterization, and new work on detailed surface characterization of the corrosion attack using laser UT.

36 MATERIALS SCIENCE↗

Cold Spray Field Deployment Evaluation for Double-Shell Tank 241-AN-105

This report highlights the documentation that supported Cold Spray field deployment in double-shell tank (DST) 241-AN-105 (AN-105) in July of 2025. This work was a collaborative effort between VRC Metal Systems (VRC), Robotic Technologies of Tennessee (RTT), the Hanford Tank Waste Operation and Closure (H2C) Chief Technology Office, H2C Tank Farm Projects Engineering, H2C Tank and Pipeline Integrity (TAPI) and H2C Ultrasonic Testing (UT) Operations & Support. Since 2019, the Chief Technology Office has been developing Cold Spray technology for refurbishing Hanford’s DSTs (RPP-RPT-65015). This technology is particularly relevant for addressing localized corrosion within the annulus of the DSTs by propelling metal powder particles at supersonic speeds to targeted areas. This process results in high-quality coatings characterized by high bond strength and low porosity result.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Nondestructive Evaluation of Carbon Fiber Reinforced Polymers

The American Society of Mechanical Engineers Boiler and Pressure Vessel Code requires repair and replacement of safety-related piping materials to meet the original Construction Code; however, no construction criteria currently exist for carbon fiber reinforced polymer (CFRP) materials in the nuclear industry. Although nondestructive examination (NDE) techniques for cast and wrought ferritic and austenitic steels are well established, licensees are increasingly deploying novel materials such as CFRP for which assessment of the use of NDE is required, as the inspectability of such materials and the influence of manufacturing processes on inspectability remain insufficiently understood. To address these gaps, Pacific Northwest National Laboratory (PNNL) evaluated the fabrication of several CFRP repair mockups and the effectiveness of NDE methods to support regulatory review of CFRP repairs in nuclear power plant applications. Representative flat-plate mockups containing realistic fabrication defects were manufactured and inspected using manual and automated tap testing, dynamic response spectroscopy (DRS), and ultrasonic testing (UT). The study identified significant fabrication variability, particularly in controlling defect size and epoxy thickness, which strongly influenced defect detectability by NDE methods. Tap testing was effective for shallow defects in thin epoxy configurations but unreliable for thicker repairs and deeper flaws. DRS demonstrated higher sensitivity to dry spots but produced unconfirmed indications for thicker plates, requiring further validation. Conventional UT, particularly at 1.0 MHz, showed the strongest overall capability for detecting a range of defects, although performance degraded with increasing repair thickness and complexity. The results highlight the need to better define critical defect sizes, develop reliable mockup fabrication methods, and validate NDE methods needed to support CFRP repairs.

36 MATERIALS SCIENCE↗

Cathodic Protection Modeling for Hanford Underground Double-Shell Tank Farms

Hanford stores millions of gallons of radioactive and chemically hazardous waste from the production of weapon materials in tank farms consisting of underground carbon-steel storage tanks surrounded by reinforced concrete. Six of these Hanford tank farms use double-shell storage tanks (DSTs). The DST farms were constructed from 1968 to 1986 with a planned 40–50 year design life, so some are already operating beyond their initial life expectancy. Ultrasonic testing (UT) has indicated significant thinning on the bottom of the secondary (outer) liner of these tanks, believed to arise from groundwater intrusion driving concrete side corrosion. There is no direct access to the steel/concrete interface between the tank and the concrete pad, making it difficult to apply a chemical-based mitigation strategy or to conduct repairs, but cathodic protection (CP) is a possible method to inhibit further concrete-side corrosion. Hanford already uses CP to protect below grade steel piping within the tank farms and connected to the tanks, but this system was not designed to protect the tank bottoms. CP design must account for the structures surrounding the DSTs, including the steel reinforcing bars (rebar) within the concrete pad and vault, various process lines, and the existing CP system. In this study, finite element analysis (FEA) modeling was carried out to simulate CP protection of 1) a single tank and CP anode to develop options for modeling the rebar and to compare to a simpler circuit model and 2) the entire Hanford AN tank farm as a representative example consisting of seven tanks, associated piping, and both existing and new CP anodes. Both circuit and FEA models predict that significant protective current could be delivered to the bottoms of the tanks with the addition of tank-protection anodes below the depth of the tanks. Simulations with only the existing pipe-protection anodes active confirmed that only a very small current to the tank bottoms is predicted under present conditions. Multiple simplified representations of the dome and wall rebar were tested to reduce the computational complexity of the tank-farm simulations, resulting in modeling the rebar as edge elements with a prescribed effective circumference that matches the real rebar surface area. The geometry of the rebar is also simplified into horizontal hoops around the tank walls and radial rebar over the dome with increased effective circumference to retain the target surface area. This simplification was found to greatly reduce the complexity and solution time of the models without large changes in current distributions, especially to the tank bottom. A range of values were tested for model parameters such as soil and concrete resistivities and polarization resistance to investigate their impact on the current and electric potential distributions. Depending on the parameters used, FEA simulations predict some risk of overprotection, particularly on the piping system; since overprotection can also lead to surface damage associated with hydrogen gas generation at the interface (e.g. hydrogen embrittlement or damage to coatings), this needs to be considered when refining the design of the new CP system. Comparison between the FEA models and the circuit model representation demonstrated that the circuit model could not match the predicted FEA current distribution, even when using the exact same surface areas. This discrepancy appeared to be at least partly attributable to the impact of the relative positions of the tank components and anodes to each other and to the ground surface. The FEA model accounts for the relative positions since it solves the governing equations in three dimensions, but the circuit model cannot account for the positioning. In particular, the circuit model underpredicts the current to the tank bottom and overpredicts the current to the dome compared to FEA for the baseline geometry. The FEA models omitted the electrically isolated rebar in the bottom concrete slab. However, a circuit based stray current model estimated that only 2.1% of the total current through the slab would stray into the rebar, corresponding to ~0.21 A for a target current density of 2 mA/ft2 to the tank bottom. The estimated corrosion driven by this amount of stray current is predicted to yield a lifetime of >400 years for the minimum rebar diameter, assuming an acceptable cross-section area loss of 10%.

d'Entremont, Anna [Savannah River National Laborat↗

Characterization of Low-Velocity Impact Damage in Thermoplastic Laminated Composites

The impact damage response of two thermoplastic material systems were compared over a range of impact energies. Eight-inch-square impact specimens with a 24-ply quasi-isotropic layup were manufactured from TC1225 LMPAEK T700G from Toray Industries and APC AS4D/PEKK-FC from Solvay. The effect of the degree of crystallinity (DOC) on the damage response was also investigated using a third set of specimens from the Toray material manufactured with reduced crystallinity. Using a combination of data obtained from X-ray computed tomography (CT) scans and ultrasonic testing (UT), detailed damage maps were created for every interface and ply for selected specimens. Using these damage maps, the delamination size, shape, and area were evaluated at each interface. The presence of fractured fibers was also identified on each ply. The LMPAEK material was found to have fewer and smaller delaminations than the PEKK specimens for impacts at the same energy. However, the LMPAEK specimens contained a larger number of fiber breaks. A similar trend was observed when comparing the baseline LMPAEK specimens with the low-crystallinity LMPAEK specimens. The low-crystallinity specimens had very little delamination but had a large number of plies with fiber breaks. In addition, the LMPAEK specimens often contained lines of fiber fractures in near-surface plies emanating from the contact region that were not present in the PEKK specimens.

Composite Materials↗

Characterization of Low-Velocity Impact Damage in Thermoplastic Laminated Composites

The impact damage response of two thermoplastic material systems were compared over a range of impact energies. Eight-inch-square impact specimens with a 24-ply quasi-isotropic layup were manufactured from TC1225 LMPAEK T700G from Toray Industries and APC AS4D/PEKK-FC from Solvay. The effect of the degree of crystallinity (DOC) on the damage response was also investigated using a third set of specimens from the Toray material manufactured with reduced crystallinity. Using a combination of data obtained from X-ray computed tomography (CT) scans and ultrasonic testing (UT), detailed damage maps were created for every interface and ply for selected specimens. Using these damage maps, the delamination size, shape, and area were evaluated at each interface. The presence of fractured fibers was also identified on each ply. The LMPAEK material was found to have fewer and smaller delaminations than the PEKK specimens for impacts at the same energy. However, the LMPAEK specimens contained a larger number of fiber breaks. A similar trend was observed when comparing the baseline LMPAEK specimens with the low-crystallinity LMPAEK specimens. The low-crystallinity specimens had very little delamination but had a large number of plies with fiber breaks. In addition, the LMPAEK specimens often contained lines of fiber fractures in near-surface plies emanating from the contact region that were not present in the PEKK specimens.

Composite Materials↗

Characterization of Low-Velocity Impact Damage in Toughened Non-Crimp Fabric Laminates

The damage response of resin-infused composites was investigated using quasi-static indentation (QSI) and instrumented drop-weight impact testing. The test specimens were composed of six layers of non-crimp fabrics where each layer contained +45°, 90°, −45°, and 0° plies. The goals of the testing were to identify damage responses that may differ from traditional thermoset materials and provide damage characterization data to evaluate current damage prediction analyses and aid improvements to current damage models. The damage was characterized using X-ray computed tomography (CT) and ultrasonic testing (UT). Incremental QSI loading was used on a single specimen to investigate damage growth in nine steps at progressively higher loads. Realtime acoustic emission data were used to determine the unloading points. Unlike typical thermoset composites, the force-displacement was smooth and showed no obvious indications of damage. The primary damage consisted of large lines of fiber fracture on the plies near the impact surface and delaminations through the thickness. Nine specimens were impacted at nominal impact energies of 25 ft-lbs, 30 ft-lbs, and 35 ft-lbs. The force histories at each energy followed nearly identical paths. Again, no obvious signs of damage were observed in any of the force histories. The general damage response in the dynamic tests was similar to the QSI-loaded specimens. However, repeat specimens impacted with a given impact energy showed variations in the damage. Some characteristics of the damage response were different than those typically observed in thermoset composites and will need to be evaluated using current analysis methods.

Composite Materials↗

Characterization of Low-Velocity Impact Damage in Toughened Non-Crimp Fabric Laminates

The damage response of resin-infused composites was investigated using quasi-static indentation (QSI) and instrumented drop-weight impact testing. The test specimens were composed of six layers of non-crimp fabrics where each layer contained +45°, 90°, −45°, and 0° plies. The goals of the testing were to identify damage responses that may differ from traditional thermoset materials and provide damage characterization data to evaluate current damage prediction analyses and aid improvements to current damage models. The damage was characterized using X-ray computed tomography (CT) and ultrasonic testing (UT). Incremental QSI loading was used on a single specimen to investigate damage growth in nine steps at progressively higher loads. Realtime acoustic emission data were used to determine the unloading points. Unlike typical thermoset composites, the force-displacement was smooth and showed no obvious indications of damage. The primary damage consisted of large lines of fiber fracture on the plies near the impact surface and delaminations through the thickness. Nine specimens were impacted at nominal impact energies of 25 ft-lbs, 30 ft-lbs, and 35 ft-lbs. The force histories at each energy followed nearly identical paths. Again, no obvious signs of damage were observed in any of the force histories. The general damage response in the dynamic tests was similar to the QSI-loaded specimens. However, repeat specimens impacted with a given impact energy showed variations in the damage. Some characteristics of the damage response were different than those typically observed in thermoset composites and will need to be evaluated using current analysis methods.

Composite Materials↗

Evaluation of Machine Learning Models for Automated Data Analysis in In-Service Nuclear Power Plant Inspections

The commercial nuclear power industry is facing a potential shortage of certified nondestructive evaluation (NDE) analysts to meet future in-service inspection demands. Automated data analysis (ADA) currently supports human inspectors in tasks such as eddy current evaluations for steam generator examinations. Machine learning (ML) systems are nearing the capability to pass performance demonstration tests for ultrasonic testing (UT) inspections of reactor pressure vessel upper head penetrations in nuclear power plants (NPPs). Current research and development is focused on assisted analysis (AA) of ADA versus fully automated examinations. This presentation will cover assessment of ML flaw detection on dissimilar metal weld (DMW) piping joints.

36 MATERIALS SCIENCE↗

Erosion-Corrosion Detection in Carbon Steel Pipe Loops using SRNLs Thickness and Mass Loss Measurement Coupons - 20464

Structural health of waste transfer infrastructure is of utmost importance to DOE and communities surrounding their active sites. A Fitness-for-Service (FFS) program for the Waste Transfer System has been implemented by the US Department of Energy (DOE) for the purposes of evaluating and quantifying the degradation of critical components. Currently, the method of approach is to section and evaluate pipelines that have been removed at end service. In order to augment data collection methods applied to making lifespan estimates of waste transfer system components, Florida International University (FIU) has been investigating new-technology based strategies for quantifying the rate of degradation. Present research considers the option of a coupon system installed on a section of pipe at points of interest that will provide easy access to high resolution measurements of erosion/corrosion rates during operation. Researchers at Savannah River National Laboratory (SRNL) have developed this novel solution for in situ erosion and corrosion measurements in many applicable locations such as tanks, pipes, ducts, and injection points. The coupons are approximately 12.7 mm (1/2 inch) in diameter and 25.4 mm (1 inch) in length and can be placed in the pipe sections using Swagelok compression fittings. The coupon design allows for monitoring of the total degradation resulting from corrosion and erosion. High-resolution Ultrasonic Thickness (UT) testing allows in-situ monitoring of both degradation mechanisms. When removed from the system mass loss resulting from corrosion and erosion may also be evaluated. Experimental testing at FIU implemented the SRNL coupon system in a 6.10 meter (20 foot) pipe loop system comprised of 50.8 mm (2 inch) and 76.2 mm (3 inch) pipe sections in order to replicate expected use cases at the sites. Operational conditions were emulated by pumping abrasive materials through the pipeline at full capacity and collecting measurements from the SRNL coupons. Initial testing was conducted by circulating water followed by a mixture of sand and water for uniform wear rates. Thickness changes and mass loss were measured, and the surface exposed to the process fluid was observed for visual evidence of characteristic wear patterns resulting from an erosive environment. The test matrix consisted of several hours of operation and using fine, medium and coarse grain sands. Test results were analyzed to check for all three parameters (mass loss/gain, thickness change and surface patters) which could provide estimates of the remaining useful life of the pipe sections. Thus, the research presents the findings of this evaluation of the SRNL coupons as a means for conducting high accuracy, cost effective in-situ analysis of pipeline and waste transfer systems for erosion and corrosion susceptibility. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

DOC-DICAM: Domain Aware One Class Defect Identification in Composite Aerostructure Material

Fiber-reinforced composites are a common material used in the design of aircraft structures due to their good tensile strength and resistance to compression. During the manufacturing process, these structures are thoroughly inspected for flaws and defects to ensure structural integrity during commercial use. Non-destructive testing (NDT) is a collection of inspection methods that allow inspectors to evaluate material without altering it. Due to the high safety standards in aerospace manufacturing, the NDT process is done manually and can be a significant bottleneck in the development workflow. In this paper, we develop an AI-based assistance tool to drastically reduce inspection time. Typical AI workflows require large amounts of annotated data, but defects rarely occur resulting in strong class imbalance. To overcome this, we formulate the problem of defect identification as an anomaly detection task in which our primary focus is learning non-defect characteristics. To do this, we develop a multi-task self-supervised learning framework that embeds problem specific domain knowledge into the deep learning model. We verify our method using fuselage data generated in a production environment. As a result, we show that our method can effectively identify defects and requires minimal training and inference time.

anomaly detection↗

RESULTS OF A VIRTUAL ROUND ROBIN STUDY TO ESTIMATE PROBABILITY OF DETECTION FOR DISSIMILAR METAL WELDS

This paper presents efforts to overcome challenges with empirical probability of detection (POD) estimations in the nuclear power industry through the utilization of a novel virtual flaw method. A virtual round robin (VRR) study was conducted under the Program for Investigation Of NDE by International Collaboration (PIONIC), organized by the United States Nuclear Regulatory Commission (NRC) utilizing data generated by the virtual flaw method. Analysis of results from the VRR was performed by teams from Pacific Northwest National Laboratory (PNNL), Electric Power Research Institute (EPRI), and Aalto University. Empirically derived POD estimations are presented, and challenges associated with obtaining these estimations are discussed. The virtual flaw method is introduced and some details of its implementation for the VRR activity are described. Results from POD analysis of the VRR data by PNNL, EPRI, and Aalto University are presented and a discussion regarding differences in analysis results is provided. Finally, potential future efforts to improve the application of the virtual flaw method and its estimation of POD are discussed.

Probability of detection, Dissimilar Metal Weld, P↗

Defect Characterization in a Thin Walled Composite RP-1 Tank: A Case Study

A full scale thin walled composite tank, designed and fabricated for the storage of pressurized RP- I rocket fuel, was fully inspected with digital infrared thermography (IR) during assembly and prior to proof testing. The tank featured a "pill capsule" design with the equatorial bondline being overwrapped on both the inner and outer surfaces. A composite skirt was bonded to the aft dome of the tank to serve as a structural support when the tank was stood on end in service. Numerous anomalies were detected and mapped prior to proof testing, some along bondlines and some scattered throughout the acreage. After the tank was intentionally burst, coupons were cut from the regions including thermographic anomalies. These coupons were again inspected thermographically to document the growth of any indications due to proof testing. Ultrasonic inspections (UT) were also performed on the coupons for comparison to thermography. Several coupons were dissected and micrographed. Relationships between IR and UT indications and the physical nature of the dissected material are presented.

Langsing, Matthew D.↗

Ultrasonic Transducer Irradiation Test Results

Ultrasonic technologies offer the potential for high accuracy and resolution in-pile measurement of a range of parameters, including geometry changes, temperature, crack initiation and growth, gas pressure and composition, and microstructural changes. Many Department of Energy-Office of Nuclear Energy (DOE-NE) programs are exploring the use of ultrasonic technologies to provide enhanced sensors for in-pile instrumentation during irradiation testing. For example, the ability of small diameter ultrasonic thermometers (UTs) to provide a temperature profile in candidate metallic and oxide fuel would provide much needed data for validating new fuel performance models. These efforts are limited by the lack of identified ultrasonic transducer materials capable of long term performance under irradiation test conditions. To address this need, the Pennsylvania State University (PSU) was awarded an Advanced Test Reactor National Scientific User Facility (ATR NSUF) project to evaluate the performance of promising magnetostrictive and piezoelectric transducers in the Massachusetts Institute of Technology Research Reactor (MITR) up to a fast fluence of at least 1021 n/cm2 . A multi-National Laboratory collaboration funded by the Nuclear Energy Enabling Technologies Advanced Sensors and Instrumentation (NEET ASI) program also provided initial support for this effort. This irradiation, which started in February 2014, is an instrumented lead test and real-time transducer performance data are collected along with temperature and neutron and gamma flux data. The irradiation is ongoing and will continue to approximately mid-2015. To date, very encouraging results have been attained as several transducers continue to operate under irradiation.

Daw, Joshua↗

Irradiation Testing of Ultrasonic Transducers

Ultrasonic technologies offer the potential for high accuracy and resolution in-pile measurement of numerous parameters, including geometry changes, temperature, crack initiation and growth, gas pressure and composition, and microstructural changes. Many Department of Energy-Office of Nuclear Energy (DOE-NE) programs are exploring the use of ultrasonic technologies to provide enhanced sensors for in-pile instrumentation during irradiation testing. For example, the ability of single, small diameter ultrasonic thermometers (UTs) to provide a temperature profile in candidate metallic and oxide fuel would provide much needed data for validating new fuel performance models. Other efforts include an ultrasonic technique to detect morphology changes (such as crack initiation and growth) and acoustic techniques to evaluate fission gas composition and pressure. These efforts are limited by the lack of existing knowledge of ultrasonic transducer material survivability under irradiation conditions. To address this need, the Pennsylvania State University (PSU) was awarded an Advanced Test Reactor National Scientific User Facility (ATR NSUF) project to evaluate promising magnetostrictive and piezoelectric transducer performance in the Massachusetts Institute of Technology Research Reactor (MITR) up to a fast fluence of at least 1021 n/cm2 (E> 0.1 MeV). This test will be an instrumented lead test; and real-time transducer performance data will be collected along with temperature and neutron and gamma flux data. By characterizing magnetostrictive and piezoelectric transducer survivability during irradiation, test results will enable the development of novel radiation tolerant ultrasonic sensors for use in Material and Test Reactors (MTRs). The current work bridges the gap between proven out-of-pile ultrasonic techniques and in-pile deployment of ultrasonic sensors by acquiring the data necessary to demonstrate the performance of ultrasonic transducers

Daw, J.↗

Impact of Thermoplastic Composites: Testing and Modeling

Thermoplastic Composites (TPCs) are being increasingly considered for aerospace applications given their faster manufacturing cycles and lower cost. The NASA High-Rate Composite Aircraft Manufacturing (HiCAM) project aims to evaluate and mature thermoplastic manufacturing technologies to achieve a 4X – 6X increase in the production rate of Next Generation Single Aisle (NGSA) commercial aircraft. Within the purview of the NASA HiCAM project, this work investigates the response of thermoplastic composites under High Energy Dynamic Impact (HEDI) conditions. HEDI tests were conducted on panels fabricated with a carbon fiber reinforced low melt semi-crystalline resin TC1225 LMPAEK T700G (T700/LMPAEK) material system. A blunt metal projectile was chosen as the impactor which impacted the T700/LMPAEK panels over a range of impact velocities imparted by a gas gun test setup. As expected, lower velocity impacts caused the projectile to rebound, whereas higher velocity impacts resulted in the projectile penetrating the test panels. For the test cases in which the projectile rebounded, the predominant damage modes recorded with Ultrasonic (UT) scans included interlaminar delaminations which exhibited a “rotating fan” like structure when viewed in the through-thickness direction. Additionally, the dynamic deflection of the center point of the back face of the test panels and the velocity of the projectile was also measured during the test. Finite element models were developed to model a test case in which the projectile rebounded. These models were developed using LS-DYNA® wherein the primary objective was to evaluate the ability of the material model MAT299 to capture the dynamic response and damage modes in the T700/LMPAEK test panels. MAT299 is a Deformation Gradient Decomposition (DGD) based Continuum Damage Mechanics (CDM) material model. The interlaminar delaminations were modeled using the cohesive contact formulation available within LS-DYNA, wherein the mixed-mode fracture is captured via the Benzegaggh-Kenane (B-K) mode-dependent fracture energy interpolation law. The above-mentioned modeling methods have mostly been applied to thermoset composites and adapting them to TPCs involves addressing challenges associated with appropriately representing material behavior. Therefore, the proposed paper would discuss the systematic approach taken to adapt thermoset composites modeling practices for applications to TPCs, while appropriately addressing material behavior. The proposed paper would show that the predicted back face center point deflection correlated reasonably well with experimental data and the peak deflection was predicted to be within 5% of the experimental measurements. The projectile rebound velocity, while predicted to be higher than the experimental measurement, was within reasonable bounds. Additionally, it will be shown that the predicted delamination shapes were in reasonable agreement with experimental data.

Composite Materials↗

Detection of tightly closed flaws by nondestructive testing (NDT) methods in steel and titanium

X-radiographic, liquid penetrant, ultrasonic, eddy current and magnetic particle testing techniques were optimized and applied to the evaluation of 4340 steel (180 KSI-UTS) and 6Al-4V titanium (STA) alloy specimens. Sixty steel specimens containing a total of 176 fatigue cracks and 60 titanium specimens containing a total of 135 fatigue cracks were evaluated. The cracks ranged in length from .043 cm (0.017 inch) to 1.02 cm (.400 inch) and in depth from .005 cm (.002 inch) to .239 cm (.094 inch) for steel specimens. Lengths ranged from .048 cm (0.019 inch) to 1.03 cm (.407 inch) and depths from 0.010 cm (.004 inch) to .261 cm (0.103 inch) for titanium specimens. Specimen thicknesses were nominally .152 cm (0.060 inch) and 0.635 cm (0.250 inch) and surface finishes were nominally 125 rms. Specimens were evaluated in the "as machined" surface condition, after etch surface and after proof loading in a randomized inspection sequence.

Rummel, W. D.↗