Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ultimate loads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Dynamic Modelling of HiveWind Floating Wind Substructure in OpenFAST

Current aero-elastic modes tend to consider the wind turbine floating substructures as rigid. However, the new generation of offshore wind platforms are leaner, less rigid. The OpenFAST code has been updated to consider the flexibility of the floating substructure. This presentation shows how a numerical model of the HiveWind design was created within OpenFAST as well as some verifications performed. When comparing the flexible model to a simplified rigid model (previous state-of-the-art), there are some significant differences in key performance indicators. The new flexibility capability within OpenFAST allows to calculate ultimate and fatigue loads within the floating substructure, allowing for the development of more economical designs.

ENGINEERING,WIND ENERGY↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Translating Fundamental Insights into Ag-Based Bimetallic Electrocatalysts to Anion-Exchange Membrane Fuel Cells

To address challenges of high costs and scalability for fuel cells, it is essential to develop af-fordable and earth-abundant materials that are Pt-group-metal (PGM)-free. Recent advance-ments in PGM-free electrocatalysis for the oxygen reduction reaction (ORR) in alkaline media show that high catalyst loadings are needed to achieve high reaction rates; however, there are associated mass transport limitations. To address this issue, we develop low-loading ionomer-less Ag-bimetallic thin films by alloying with 3d block elements or Sn. We bridge knowledge from fundamental rotating disk electrode (RDE) studies to gas-diffusion cathodes in high-temperature anion-exchange membrane fuel cells (HT-AEMFCs), resulting in high-activity ORR catalysis and peak power densities up to 1.2 W cm-² geo for the Ag-Sn and Ag-Co alloys. Here, experimental post-characterization and theoretical calculations reveal small Co or Sn oxide nano-islands on Ag as likely active sites enhancing ORR activity, ultimately offering these low-loading PGM-free ORR materials as a viable path towards sustainable energy conversion.

Catalysts↗

Length and Seed Current Scaling of a Mark X HG driven, 8 inch PBX9501 RancheroS FCG system: II

This report is intended to examine the ultimate operating limits of the combined Pt. 88 capacitor bank (CB) + MarkX Helical Generator (HG) driving a RancheroS Flux Compression Generator (FCG) with various physics experiment load inductances. As such, many degradation mechanisms are neglected in this study. In actual use, degradation of the HG output current delivered to the FCG will probably occur. Internal changes in the HG can occur due to both Ohmic heating in the generator leading to a time varying series resistance [R(t)] such as that seen in the first trial (Shot 0) of the MarkX, as well as any misbehavior, such HG internal turn to turn shorts such as seem to have occurred in subsequent MarkX tests. Both reduce the output current from the HG that is used to seed the FCG. The results discussed here are intended to probe the limits of the RancheroS driving various loads, in an ideal situation in which none of the HG or system degradation mechanisms prior to the FCG armature first motion (FM) reduce the seed current. The HG is modeled simply as a time varying inductance [L(t), as measured in Shot 0], with a constant internal resistance [R(t) = 0.2mOhm]. The RancheroS itself is fully modeled, including all FCG and load degradation mechanisms, thus probing the ultimate capabilities of the full system, independent of problems upstream of the FCG.

47 OTHER INSTRUMENTATION↗

Time Matters: A Survival Analysis of Public Electric Vehicle Charging Infrastructure Utilization

The rapid adoption of plug-in electric vehicles (PEVs) places significant demands on public charging infrastructure, making it critical to understand and optimize charger utilization. This study provides one of the most comprehensive analyses of charging behavior to date by applying a survival analysis to a dataset of nearly 16 million level 2 (L2) and direct current (DC) fast charger sessions across the United States from 2017 to 2022. Using Kaplan-Meier curves and log rank tests, our analysis reveals statistically significant and distinct duration patterns influenced by charger type, time of day, and day of the week. We find that L2 charging sessions exhibit high variability tied to venue type, whereas DC sessions are more uniform, typically lasting 30-45 min. This study introduces the operational efficiency score (OES), a metric for standardizing the performance evaluation of charging stations. Our findings offer actionable insights for optimizing charger deployment, developing dynamic pricing strategies to reduce vehicle dwell time, and improving load management for grid operators, ultimately enhancing the efficiency and availability of public charging infrastructure.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Employing Weibull Analysis and Weakest Link Theory to Resolve Crystalline Silicon PV Cell Strength Between Bare Cells and Reduced- and Full-Sized Modules

Weibull analysis and weakest link theory are employed to resolve the probability of crystalline silicon PV cell fracture when measured as bare cells and when stressed in reduced- and full-sized modules. Experimental results indicated that the characteristic cell strength is reduced by ~20% once packaged into the laminate of a one-cell module and loaded in four-point flexure (4PF). This experimental observation was shown consistent with a weakest link theory prediction that the strength limiting flaws reside on the surface of the cell's edge. Here, the analysis is ultimately extended to present the equivalent loading of four-cell modules by uniform pressure and 4PF and a uniformly loaded full-sized module and demonstrates that smaller, representative, modules must be loaded to a much higher level than their parent full-sized modules to achieve an equivalent probability for cell fracture.

14 SOLAR ENERGY↗

A Conceptual Framework to Describe Energy Efficiency and Demand Response Interactions

Energy efficiency (EE) and demand response (DR) resources provide important utility system and ratepayer benefits. At the same time, the rapid change in the amount and type of variable renewable energy, like solar and wind, is reshaping the role and economic value of EE and DR, and will likely affect time-dependent valuation of EE and DR measures. Utilities are increasingly interested in integrating EE and DR measures and technologies (as well as other distributed energy resources) as a strategic approach to improve their collective cost-effectiveness and performance. However, the specific EE and DR features that may be best integrated, the interplay between changing EE and DR resource potential, and the resulting utility system impacts, are not well understood. We develop a framework to identify the EE and DR attributes, system conditions, and technological factors that are likely to drive interactions between EE and DR. We apply the framework to example measures with different technology specifics (e.g., presence of controls, building type, and targeted end use) in the context of different system conditions (e.g., peak demand, load-building periods during high renewable generation output). Ultimately, the framework defines EE and DR interactions not only by the change in discretionary load (i.e., DR potential) but also by the change in likelihood of participation in EE and DR programs—as well as the change in system need for, and the overall availability of, EE and DR resources. The framework is intended to improve the integration of EE and DR in utility operational and planning activities.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Performance Evaluation of Three RTU Energy Efficiency Technologies

This project was part of an effort by CLEAResult and ComEd to evaluate the energy saving potential of emerging technologies in the Chicago area. This project focused on evaluating emerging technologies related to rooftop units (RTUs). An RTU with a single-stage compressor and a constant-speed fan with an induction motor was selected as the baseline for technology comparison. Three retrofit strategies were investigated. The first two involved replacing the single-stage compressor of an RTU by either a two-stage or variable-speed compressor and adding a variable frequency drive (VFD) to the constant speed fan. The use of a multi-/variable-stage compressor improves the part-load efficiency of the compressor which will ultimately result in annual energy savings as well as peak demand shaving in some cases where the design capacity of the RTU is larger than the maximum cooling load of the building space that it is serving. The third technology was the use of a high rotor pole switched reluctance motor (SRM) as a replacement for the constant-speed supply fan. The SRM was applied in single-speed, two-stage and variable-speed compressor RTUs. SRM motors run via reluctance torque. Their stator poles are driven by direct current (DC) power and require an inverter as well as active control when using alternating current (AC) power. This inherent property results in high efficiency over a range of operating conditions. It also exhibits higher efficiency compared to variable frequency drives (VFDs) since its switching frequency is much slower (SCE, 2018).The three technologies investigated are summarized below: 1) Replacing the single-speed compressor with a two-stage compressor and adding a VFD to the supply fan. 2)Replacing the single-speed compressor with a variable-speed compressor and adding a VFD to the supply fan. 3) Replacing the constant-speed induction motor of the supply fan with a high rotor pole SRM. DOE’s building simulation platform EnergyPlus and its graphical user interface OpenStudio were used to evaluate the energy-saving potential of upgrading RTUs, by leveraging experimental data from previous research.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Unitary Thermal Energy Management for Propulsion Range Augmentation (UTEMPRA) (CRADA Final Report)

NREL will work with Delphi to develop technology that integrates the thermal management of electric drive vehicle sub-systems into a unified thermal system that reduces auxiliary loads and increases vehicle range. The ultimate goal is to create a cost-effective system which improves climate control efficiency through heat pump operation and waste heat recovery, while maintaining occupant thermal comfort and meeting powertrain thermal requirements. The technology will also aim to reduce the number of independent cooling systems required in electric drive vehicles.

33 ADVANCED PROPULSION SYSTEMS↗

Review of wake management techniques for wind turbines

Summary The progression of wind turbine technology has led to wind turbines being incredibly optimized machines often approaching their theoretical maximum production capabilities. When placed together in arrays to make wind farms, however, they are subject to wake interference that greatly reduces downstream turbines' power production, increases structural loading and maintenance, reduces their lifetimes, and ultimately increases the levelized cost of energy. Development of techniques to manage wakes and operate larger and larger arrays of turbines more efficiently is now a crucial field of research. Herein, four wake management techniques in various states of development are reviewed. These include axial induction control, wake steering, the latter two combined, and active wake control. Each of these is reviewed in terms of its control strategies and use for power maximization, load reduction, and ancillary services. By evaluating existing research, several directions for future research are suggested.

17 WIND ENERGY↗

High-temperature superelasticity in NiTiPt and NiTiPd shape memory alloys

Alloying NiTi shape memory alloys with sufficient Pt and Pd at the expense of Ni has been shown to increase transformation temperatures well above those possible with the binary composition, enabling consideration of a new class of high-temperature mechanical sensors and actuators. To achieve shape memory behavior at temperatures greater than 200 °C, previous studies of NiTiPt and NiTiPd compositions have focused primarily on alloys with greater than 16 at.% Pt and 25 at.% Pd. While generally not the focus, none of these previous studies demonstrated superelastic behavior at high temperatures. In an effort to identify alloys that transform to austenite at approximately 200 °C and exhibit superelastic behavior with recoverable strains greater than 2%, a series of Ti-rich NiTiPt ternary alloys with 15.5–16.5 at.% Pt, and Ti-rich NiTiPd ternary alloys with 25–26 at.% Pd have been targeted. The polycrystalline alloys were processed via arc melting followed by homogenization heat treatment. Thermomechanical properties were measured using electro-discharge machined tension test coupons and a miniature load frame equipped with a clamshell furnace. Ultimately, superelasticity in uniaxial tension with clear plateau regions was demonstrated and characterized in these alloys at temperatures between 219 °C and 270 °C.

Massad, Jordan E.↗

Synchronous Machine Governor Upgrade

Conventional generation sources play a critical role in the stability and reliability of the electrical grid, particularly as we transition towards more renewable energy sources. To understand and accurately emulate their behavior for optimizing grid operations and ensuring seamless integration with renewable technologies, it is essential to better emulate the grid- and plant-level impacts of conventional generation sources, such as natural gas (NG) driven heat recovery steam generators (HRSGs) and combustion turbines (CTs). Therefore, a governor model is developed in a programmable logic controller (PLC) to investigate the performance of the conventional generator under various dynamic operating conditions and to identify the impact on grid stability in a controlled environment. The governor model aims to enable the hardware-in-the-loop (HIL) based emulation of these conventional generation sources using the existing 2 MVA synchronous machine/generator that is driven by a flexible 2.5 MW variable speed drive. This setup will allow us to replicate the dynamic characteristics and response behaviors of NG-driven HRSGs and CTs. The controls for the emulated conventional plants follow the industry standard and are adjustable, ensuring they accurately reflect the operational capabilities and limitations of real-world systems. These controls include load-following capabilities, ramp rates, startup and shutdown sequences, and emissions characteristics. By incorporating these adjustable controls, we aim to capture the nuanced impacts of conventional generation, such as their ability to provide ancillary services like frequency regulation, voltage support, and spinning reserve. In this report, we simulate two types of dynamic operations: grid-connected and islanding. For each dynamic operation, representative starting sequences are tested, including turbine purge, ignition, speed ramping up, generator excitation and synchronizing, and breaker close. The HIL based tests provides insights for field deployment, specifically the high-fidelity governor model provides results to predict the potential stability and reliability risk and suggest possible integration measures (e.g., generation and load balancing, tuning of governor control parameters). Ultimately, this enhanced emulation capability will be integrated into our Advanced Research on Integrated Energy Systems (ARIES), enabling us to conduct comprehensive studies on the interactions between conventional and renewable energy sources. By better understanding these interactions, we can develop strategies to optimize the overall performance and reliability of the grid. This will support the deployment of advanced grid management techniques, such as demand response, grid-forming inverters, and energy storage systems. The main contributions are summarized as follows: (1) This report introduces a PLC-based governor model for gas turbines. This model accurately simulates the dynamic behavior of conventional generation sources under various operational scenarios; (2) The model is integrated with an HIL testbed that includes a 2.5 MW variable speed drive and a 2 MVA synchronous machine. This setup enables realistic, real-time emulation of conventional power plants, particularly NG driven HRSGs and CTs; (3) The developed model is adaptable to various gas turbine configurations and allows for precise control over parameters such as MW ramp rates. This flexibility makes it a valuable tool for future research and industry collaboration; and (4) By incorporating the model into the National Renewable Energy Laboratory's Advanced Research on Integrated Energy Systems, the report lays the groundwork for future studies on interactions between conventional and renewable energy sources, enhancing the ability to develop advanced grid management strategies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advances and perspectives on mass transfer and enzymatic hydrolysis in the enzyme-mediated lignocellulosic biorefinery: A review

We report enzymatic hydrolysis is a critical process for the cellulase-mediated lignocellulosic biorefinery to produce sugar syrups that can be converted into a whole range of biofuels and biochemicals. Such a process operating at high-solid loadings (i.e., scarcely any free water or roughly ≥ 15% solids, w/w) is considered more economically feasible, as it can generate a high sugar concentration at low operation and capital costs. However, this approach remains restricted and incurs “high-solid effects”, ultimately causing the lower hydrolysis yields with increasing solid loadings. The lack of available water leads to a highly viscous system with impaired mixing that exhibits strong transfer resistance and reaction limitation imposed on enzyme action. Evidently, high-solid enzymatic hydrolysis involves multi-scale mass transfer and multi-phase enzyme reaction, and thus requires a synergistic perspective of transfer and biotransformation to assess the interactions among water, biomass components, and cellulase enzymes. Porous particle characteristics of biomass and its interface properties determine the water form and distribution state surrounding the particles, which are summarized in this review aiming to identify the water-driven multi-scale/multi-phase bioprocesses. Further aided by the cognition of rheological behavior of biomass slurry, solute transfer theories, and enzyme kinetics, the coupling effects of flow-transfer-reaction are revealed under high-solid conditions. Based on the above basic features, this review lucidly explains the causes of high-solid hydrolysis hindrances, highlights the mismatched issues between transfer and reaction, and more importantly, presents the advanced strategies for transfer and reaction enhancements from the viewpoint of process optimization, reactor design, as well as enzyme/auxiliary additive customization.

45 multi-scale, multi-phase, enzymatic reaction↗

Strain-rate hardening enhances fatigue resistance of AlSi10Mg alloy at 350°C

The high cycle fatigue behavior of laser powder bed fusion processed AlSi10Mg has been investigated at 350 °C (T/T m ∼ 0.7). The alloy exhibited a fatigue strength of 30 MPa defined by runout after 10 7 cycles at a conventional loading frequency of 20 Hz, corresponding to a notable fatigue strength to ultimate tensile strength ratio of 0.73. The surprising fatigue resistance was attributed to the strain-rate hardening effect at high fatigue loading frequency relative to tensile loading rates at 350 °C. The strain-rate hardening effect was validated by performing ultrasonic fatigue tests (20 kHz loading frequency) with three orders of magnitude higher strain-rates than those at conventional loading frequency. The higher strain-rates in ultrasonic fatigue increased the magnitude of strain-rate hardening resulting in longer AlSi10Mg fatigue lives compared to fatigue at conventional frequency, thus confirming the strain-rate hardening effect. The fatigue crack initiation mechanism was strain-rate dependent. Post-mortem microstructural examination revealed intergranular cavitation inside clusters of fine equiaxed grains. The cavities interlinked with each other to initiate near-surface fatigue cracks at conventional frequency. Cavitation occurred to a lesser extent at the ultrasonic frequency. As a result, fatigue cracks initiated at pre-existing processing defects near the surface in ultrasonic fatigue samples. Finally, this investigation underscores the role of fine grain clusters in promoting high-temperature fatigue crack initiation and indicates a possible trade-off between printability via grain refinement and high-temperature fatigue resistance of additively manufactured alloys.

Additive manufacturing↗

Progress in Fast Modular Reactor Conceptual Design

The Fast Modular Reactor (FMR) is a 100-MW(thermal) gas-cooled fast reactor being developed by General Atomics Electromagnetic System with the goal of developing a FMR for flexible and dispatchable power to the U.S. electricity market in the mid-2030s. The conceptual design aims to develop and verify simplified design features. These include an inert helium gas coolant, pellet-loaded fuel rods, installations with air cooling as ultimate heat sink, and small and passive heat removal systems. The goal is to ensure the development of a safe, maintainable, cost-effective, and distributed nuclear energy-generating station. The baseline technologies selected to achieve this goal are a helium coolant that is an inert gas with no chemical reaction with structural components, not activated, single phase, enabling high-temperature operation and a high thermal efficiency Brayton cycle; conventional uranium dioxide (UO 2 ) fuel, which is the most widely used and well-known fuel material, capable of high burnup (100 MWd/kg) and a long fuel life; and silicon carbide composite (SiGA®) cladding and internal structures that are chemically inert in the helium environment, exceptionally radiation tolerant, and being derisked by accident tolerant fuel technology development. Further, the reactor was specifically designed with passive safety features, including high-temperature in-core materials and a reactor vessel cooling system consisting of cooling panels of naturally circulating water. The passive safety of the core was confirmed for the depressurized loss-of–forced cooling accident, which showed the peak cladding temperature at ~1600°C during the transient, which is below the current design limit of 1800°C. The conceptual design of the FMR has been conducted for the reactor system, vessel system, generator and turbomachine, instrumentation and control, residual heat removal system, plant service system, and containment, as well as pre-application licensing documents.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Characterization and repair of core gap manufacturing defects for wind turbine blades

Various wind turbine blade components, such as shear webs and skins, commonly use fiber-reinforced composite sandwich structures with a core material like balsa or foam. During manufacturing, core gap defects may result from the misalignment of adjacent foam or balsa core sheets in the blade mold. It is important to understand the influence that core gaps have on the structural integrity of wind turbine blades and how to mitigate their influence. This research characterized the effects of core gap defects at the manufacturing and mechanical levels for both epoxy and next-generation thermoplastic composites. Common repair methods were assessed and compared. Multiple defect sizes were compared using temperature data gathered with thermocouples embedded during manufacturing to core gap defect characteristics obtained using image-mapping techniques, optical microscopy, and mechanical characterization by long beam flexure. Results showed that peak exothermic temperatures during curing were closely related to core gap size. The long beam flexure tests determined that transverse core gaps under pure bending loads can have a substantial effect on the ultimate facesheet strength of both epoxy and thermoplastic composite sandwich structures (up to 25% strength reduction), although the size of the defect itself had less of an influence on the magnitude of the strength reduction. The supporting image-mapping techniques indicated that the distortion of the composite facesheets by the core gaps contributed to the premature failures. The repair methods used in this study did very little to improve the ultimate strength of the sandwich panels that previously had core gap defects. The repair of the thermoplastic panel resulted in a further loss in ultimate facesheet strength. This research demonstrated that there is a vital need for the development of a compatible thermoplastic polymer repair resin system and appropriate resin specific repair procedures for the next generation of recyclable thermoplastic wind blades.

17 WIND ENERGY↗

Overcoming the Technical Challenges of Coordinating Distributed Load Resources at Scale (Final Report)

Significant recent research has investigated the potential for loads to provide balancing services to the grid. However, this research has not addressed key issues that may arise when such schemes are applied at scale including: 1. Distribution Network Issues. Coordination of large numbers of loads could result in power flows that violate distribution network constraints; 2. Stability Issues. Certain strategies to control loads can exhibit nonlinearity in the form of period-adding bifurcations and chaos. Other control strategies can potentially synchronize the behavior of large numbers of loads. In both cases, the outcome can be power oscillations and instability; 3. Communication Network Issues. Bidirectional low-latency communication channels between a central controller (or several distributed controllers) and each resource are expensive and likely not necessary for effective coordination. Our research questions were: What network, stability, and communication issues might arise in practice when we coordinate large aggregations of loads? How can we coordinate loads to achieve performance objectives in a cost effective manner while avoiding these issues? The ultimate technical goal of the project was the development of network-aware, communication-constrained, non-disruptive load control strategies with stability guarantees that achieve the performance requirements of typical balancing services at a sufficiently low cost to enable the load aggregator and customer to profit. The overall goal was to establish credibility for load control at scale and contribute to U.S. energy security and environmental goals. The team succeeded in answering these research questions and developing these control strategies. The overall approach was based on the development of three testing environments: a simulation testbed, an experimental testbed (20 physical model houses with window-box air conditioners) coupled with the simulation testbed, and a field testbed (100 actual homes in Austin, TX) coupled with the simulation testbed, which enabled controller testing, identification of issues, controller development, and controller validation. The resulting controller was used to demonstrate fast timescale grid balancing (frequency regulation) by aggregations of physical and virtual air conditioners, with sufficient quality to participate in the electricity market. Cost benefit analysis showed overall benefits to the participating households, load aggregators, and the grid, especially if the control technology was integrated directly into existing programmable communicating thermostats. The project provides a variety of wider benefits. Our technology transfer and outreach activities lead us to choose an open-source licensing commercialization pathway, enabling the project results to be available to researchers, industry, and the public. Furthermore, new grid balancing technologies will increase grid flexibility and will enable higher penetrations of intermittent renewable energy resources, such as wind and solar, to be connected to the grid, reducing its environmental impact, and mitigating climate change to the benefit of society.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Subsurface mechanical damage of fused silica glass during grinding by various sub-aperture tools with and without ultrasonics

The subsurface mechanical damage (SSD) depth after grinding fused silica glass with a comprehensive set of sub-aperture fixed abrasive grinding tools [cup, wheel, belt, pad, and rotary face mill (with and without ultrasonics)] and process parameters has been statistically measured using the taper wedge technique and evaluated. Consistent with a previously reported grinding model [J. Non-Cryst. Solids 352, 5601–5617 (2006) Crossref , Materials Science and Technology of Optical Fabrication (Wiley & Sons, 2018)], based on the sliding indentation fracture by sliding particles or asperities where the normal load per particle determines the depth of the fracture (and ultimately the overall SSD depth), the dominant factor controlling SSD depth was found to be the abrasive size regardless of the tool type and process conditions. Compared to full aperture grinding methods, the overall SSD depth was higher using the sub-aperture tools, likely due to the higher effective pressure and higher load per particle distribution. Here, in addition to abrasive size, a significant reduction in SSD depth was achieved by: (1) reducing the load distribution on the abrasive particles via increase in contact area and/or decrease in mechanical loading; (2) using a more compliant host tool medium; and (3) in what we believe is a more novel way, using ultrasonics. Combining low abrasive size, larger contact area, and a compliant host, the 6 µm diamond in a resin matrix (Trizact) on a foam pad led to very low SSD depth (~ 4.6 µm), relatively fast grinding rate (186 mm 3 /h), and little or no figure degradation. This grinding tool/process is an attractive choice for final grind, resulting in significantly reduced polish out (i.e., “grey out”) times. With the rotary face mill tool, the use of ultrasonics consistently led to a SSD depth reduction (ranging from 17%–34%). A new fracture mechanics-based model, to the best of our knowledge, where the relevant normal load is parallel to the feed direction, has been developed to explain how ultrasonics leads to lower SSD depth. The key factors, supported by finite element stress analysis and load measurements, are (1) the initiation of fractures at higher z heights during the tool’s ultrasonic vertical oscillations, thus propagating less deep into workpiece; (2) reduction in load (and therefore reduction in fracture propagation distance) due to smaller tool-workpiece feed direction contact area (again caused by higher heights relative to depth of cut); (3) upward movement of the tool during oscillation leads to fracturing toward the surface instead into the depth; and finally (4) at tool’s lowest point of oscillation cycle, there may not be enough time for the fracture to propagate to its full length.

Optics and optical instruments↗