A Smarter Typical Meteorological Dataset: Advancing Accuracy in Solar Energy Yield Estimation
This poster provides an overview a smarter typical meteorological dataset to advance accuracy in solar energy yield estimation.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
This poster provides an overview a smarter typical meteorological dataset to advance accuracy in solar energy yield estimation.
The ResStock Analysis Tool was developed by NREL with support from the U.S. Department of Energy to provide a new approach to large-scale residential analysis by combining large public and private data sources, statistical sampling, detailed sub hourly building simulations, and high-performance computing. This combination achieves unprecedented granularity and accuracy in modeling the diversity of the housing stock and the distributional impacts of building technologies in different communities. The annual baseline energy results from a national-scale ResStock run use typical meteorological year 3 (TMY3) files for energy simulations. Results include heating and cooling loads for individual components of each building. Component loads describe the heating/cooling load that can be attributed to specific elements of a home, such as heat transfer through walls or internal gains. Additionally, these results include the standard ResStock outputs for housing characteristics and numerous energy outputs by end-use and fuel. A snapshot of the ResStock version used to produce this data, including a configuration file for the run can be found using the Source Code resource link.
This study evaluates the long-term effectiveness of energy conservation measures (ECMs) on building energy consumption using AutoBEM, a scalable modeling framework driven by the high-resolution Model America dataset. We simulated 18,951 buildings in Flagstaff, Arizona under four climate scenarios using Future Typical Meteorological Year (fTMY) weather files for six time periods spanning from 1980 to 2099. Six ECMs were analyzed across electricity and gas usage, including HVAC fuel-switching, insulation upgrades, and infiltration control. While some measures, such as reducing space infiltration by percentage, showed minimal or even negative impact on total energy savings at the aggregate level, they proved highly effective for specific building types. Conversely, HVAC electrification offers high gas reduction but shifts demand to electricity, highlighting critical trade-offs under different climate trajectories. Building-type-specific analysis under SSP5-RCP8.5 (2080–2099) revealed significant variation in ECM performance, underscoring the need for targeted retrofit strategies. This study demonstrates the power of combining fTMY projections with large-scale simulations to inform data-driven retrofit planning.
Jurisdictions are increasingly adopting compensation structures for distributed PV and PV-battery systems that price exported energy lower than energy consumed onsite (net billing rates). Standard methods for calculating the bill savings from PV and PV-battery systems were developed for net metering structures, and applying these same methods to net billing structures (such as using Typical Meteorological Year weather with actual year load) introduces bias errors that underestimate PV-battery system bill savings by between 1.5\% and 9\%, depending on the utility rate. We assess the magnitude of these errors and compare them to other sources of uncertainty when estimating the bill savings from PV and PV-battery systems under more complex utility rates.
This report details the results of building energy modeling analysis evaluating the potential energy savings, economic outcomes, and grid-level electricity reduction associated with cold climate air source heat pump (ccASHP) adoption across multifamily and manufactured housing (MMFH) building typologies in the City and Borough of Juneau (CBJ). Three building archetypes were evaluated: multifamily 4-plex apartments, multifamily 8-plex apartments, and manufactured housing units. Building energy models were developed using OpenStudio-HPXML and calibrated to actual utility consumption data and local meteorological data from the Juneau International Airport weather station using an automated calibration tool following the BPI-2400-S-2015 v.2 standard for model calibration. Occupant behaviors present the greatest variability in successful calibrations. Calibrated models were benchmarked against a baseline electric resistance heating condition, with the selected ccASHP modeled as the retrofit condition and typical meteorological year weather data for all results generation.
Here we automate the process to enable the creation of world maps for specific PV durability metrics. The end goal is to create a tool for the creation of world maps predicting the sensitivity of modules to degradation to inform the development and utilization of module testing standards and to provide information to module designers. TMY (Typical Meteorological Year) Data was aggregated from sites around the world to render insight into factors contributing to the degradation of solar modules. The focus of aggregating data was to create a single dataset to work with utilizing Solar Irradiance values combined with Ambient Temperature, Relative Humidity, Wind Speed and Dew-Point Temperature.
Energy efficiency and energy savings have become an important factor as industries look for ways to save energy and minimize their energy consumption while reducing their carbon footprint. Cooling towers are utilized significantly in industries for either serving chillers or process cooling. Depending on the size of the cooling tower, it can use a surprising amount of energy and water, which is why it is crucial to make sure that the facility has optimized their cooling tower.A modeling tool has been developed to perform a thorough analysis of a cooling tower and its various operations to ensure that the facility has optimized its cooling tower. This model analyzes an annual base case in comparison with the revised case of a cooling tower operation. This modeling tool simulates 8,760 hourly calculations for fan power for various fan controls, water consumption, and pumping energy consumption and demand based on the user’s location and its corresponding Typical Meteorological Year 3 (TMY3) weather data. This model is capable to simulate up to five cooling tower cells as one large tower utilizing one pump or parallel pumping. The successful validated cooling tower model should assist industry to save energy at their facility through their cooling tower, whether they use it for process cooling or heating, ventilation and air conditioning (HVAC) applications. The entering/leaving water temperatures based on a monthly operating schedule or a wet-bulb temperature schedule will be used as inputs, and the model can calculate savings in energy for various conditions including variable-frequency drive (VFD) on the fan/pump, drift eliminators, number of cycles of concentration, reduced water flow rate, etc.
Heat pumps play an instrumental role in buildings decarbonization strategies. Recent advances in heat pump systems employ variable-speed compressor technology and electronically commutated fan motors. Inherently, the heating capacity and efficiency of heat pumps decrease with falling outdoor temperatures. Compared to single-speed heat pumps, variable speed systems can maintain higher heating and cooling efficiencies over a wider range of outdoor temperatures. The goal of this multi-phase project was to determine the energy savings of a high efficiency, variable-speed, air-source, split system heat pump designed for cold climate applications. The first project phase was to evaluate the performance of the heat pump in the laboratory under varying outdoor conditions in heating and cooling modes. The second phase was to translate the laboratory-measured performance into lookup tables for EnergyPlus hourly building simulation engine. Then, two sets of annual building simulations were performed using typical meteorological year weather from the Chicago-O'Hare airport for three different building types (a single-family residence, a strip mall, and a low-rise office building). The first set simulated a standard efficiency heat pump while the second set utilized the phase two performance tables to model a high efficiency heat pump. The high efficiency heat pump produced significant annual heating energy savings in all three buildings. The variable speed compressor and fan control also contributed to cooling energy savings. The simulated annual energy savings ranged from 22% to 35% over their respective baseline. The project's findings helped a Midwest electric utility, Commonwealth Edison (ComEd), design new incentives around high efficiency heat pumps.
Weather data plays a critical role in renewable energy analysis. Compared to using multiple Actual Meteorological Years, simulations using a single typical year require significantly fewer computational resources. Previous efforts to create typical weather datasets for renewable energy analysis either lack justified or optimized strategies for selecting and weighting different weather parameters or are limited to a few specific locations. Here, in this study, we developed a dataset comprising Typical Solar Years (TSYs) and Typical Wind Years (TWYs) for over 2000 locations across the U.S., based on data from NASA's POWER project. The strategies for creating TSYs and TWYs were optimized based on the simulated outputs of various PV systems and wind turbines in 16 representative cities. This dataset provides an efficient means for the rapid evaluation and optimization of renewable energy systems throughout the entire U.S. Additionally, the optimal strategies identified in this study can be directly applied to create near-optimal TSYs and TWYs for most locations worldwide. However, readers can also employ the optimization approach presented in this work to develop optimal strategies tailored for particular regions.
The effectiveness of climate change impact assessments and the development of adaptation strategies depend on the availability of high-quality future weather data. However, significant gaps exist between the needs of the energy research community and the focus of the climate modeling community, primarily due to a historical lack of communication and collaboration between the two groups. Here, to address this issue, this work provides a comprehensive overview of the critical aspects involved in creating future weather data for building and energy system modeling, including emissions scenarios, general circulation models, downscaling methods, categories of future weather data, and uncertainties in climate simulations. Moreover, it critically evaluates the applicability and suitability of various types of future weather data in five key application scenarios: energy use analysis, resilience analysis, HVAC design, utility-scale analysis, and renewable energy analysis. Finally, this work presents recommendations for high-level actions and research directions to foster collaboration between the energy research and climate modeling communities and to promote the integration of future weather data into energy codes and the design practices of buildings and energy systems.
Zero-net-energy (ZNE) homes produce an adequate amount of energy on-site to meet their energy demand based on source energy for an entire year. California building energy efficiency standards require new residential buildings started in 2020 to be ZNE. For various reasons, a home designed as ZNE may not achieve ZNE performance in real operation. Here we aimed to quantify the robustness of the energy performance of ZNE homes due to weather variability, climate change, and the uncertainty of occupant behavior. A single-family ZNE house, based on the optimal cost-effective design in three California climate zones, was used to develop the EnergyPlus simulation models. Weather variations were considered from a combination of the historical 30 years’ actual meteorological year (AMY) weather data, typical year weather data in TMY3, and future weather data based on Intergovernmental Panel on Climate Change scenarios. Three scenarios of occupant behavior from the energy perspective were defined to represent the uncertainty about occupants’ activities, comfort requirements, and their adaptive interactions with buildings and systems. In terms of annual source energy, the simulation results of the ZNE homes showed: (1) a decrease of 23–38 percent for occupants with energy austerity behavior and an increase of 120–130 percent for occupants with energy wasteful behavior, compared with the baseline assumption of normal occupants; (2) a variation range of –15 percent to +14 percent for the results using 30-year AMY weather data compared with the baseline results using TMY3 weather data; (3) an increase of 10–13 percent with future weather in Fresno and Riverside and a decrease of 15 percent with San Francisco; and (4) climate change can reduce the gap between the austerity and wasteful consumption. These findings provide insights into how ZNE homes may perform in reality and inform architects, engineers, occupants, and policymakers to pay more attention to occupant behavior on design, operation, and regulations of ZNE homes to ensure energy performance robustness.
Five years of meteorological and hydrological data from a typical New England watershed where winter snow cover is significant were used to drive and validate two off-line land surface schemes suitable for use in the Goddard Institute for Space Studies (GISS) general circulation model (GCM): a baseline scheme that does not model the physics of a snowpack and therefore, neglects the insulating properties of snow cover; and a modified scheme in which a three-layer snowpack is modeled. Comparing baseline model results with validation data reveals several model deficiencies. Surface radiation temperatures could not adequately be modeled and the ground froze to unreasonable depths. Furthermore, because of ground cooling resulting from large surface heat fluxes to the atmosphere from the uninsulated surface, deeper model layers did not unfreeze until midsummer. As such, the normal hydrologic processes of runoff, ground water infiltration, and movement, etc., are compromised for a good part of the year. With the inclusion of a simple three-layer snow model into the baseline model, not only are the ground and surface radiation temperatures adequately modeled but all the features of snowpack ripening that characterize pack growth/ablation are simulated.
Seventeen dipole eddies, including five large, well-formed ones, three second-generation eddies, and two double eddies, were observed in the Alaska Coastal Current near Kayak Island in one single scene of the Landsat thematic mapper (TM) on April 22, l985. The digital Landsat TM satellite data were computer analyzed to extract details in the near coastal circulation in the northern Gulf of Alaska. Enhancement techniques were applied to the visible and thermal IR bands. The features are evident only in the visible bands because of the ability of these bands to detect the distribution of sediments in the near surface. These eddies did not have a significant thermal signature.The sources of these sediments are the glacial streams found throughout the Gulf of Alaska coast. Eddies of this configuration and frequency have never been observed here previously. However, the oceanographic and meteorological conditions are typical for this time of year. These eddies should be important to the cross-shelf mixing processes in the Alaska Coastal Current and are an indicator that the flow here can be unstable at certain times of the year.
Fine particulate matter (PM2.5) substantially contributes to air pollution and negatively affects human health. While many studies have investigated the use of passive column-integrated aerosol optical depth to infer surface PM2.5, the use of lidar observations for air quality characterization is not nearly as extensive. Lidar measurements are critical, however, due to the vertical aerosol information they provide, including near the surface. In this presentation, we first provide an overview of various lidar-based approaches for estimating PM2.5 concentrations and then discuss how lidar measurements can assist other air quality applications. For example, estimates of PM2.5 have been obtained in a physics-based approach through CALIOP near-surface aerosol extinction retrievals, assumptions on the mass extinction efficiency, and incorporating other parameters (an aerosol hygroscopic growth factor and PM2.5/PM10 ratio). Application of this algorithm over the contiguous United States (CONUS) from 2006 to 2018 yielded larger PM2.5 values over the eastern and western CONUS (~10-15 μg/m³) and lower PM2.5 levels in the central CONUS (~5 μg/m³). These spatial patterns were similar to those from gridded PM2.5 concentrations obtained through in situ measurements at ground stations operated by the US Environmental Protection Agency. In another approach, the Cloud Aerosol Transport System (CATS) lidar was used with the Goddard Earth Observing System (GEOS) model in a 1D ensemble-based variational technique to obtain PM2.5 over the US and Europe, and the spatial patterns of the CATS/GEOS based PM2.5 concentrations generally captured those from surface stations (with corresponding hourly EPA PM2.5 vs CATS PM2.5 statistics of R=0.4 and bias=1.5 μg/m³). In our recent work, as part of the Models, In situ, and Remote sensing of Aerosols (MIRA) Working Group, we have applied both the CALIOP and CATS/GEOS based approaches over the highly polluted country of India during the post-monsoon season (September-October 2016). We derived elevated levels of two-month mean PM2.5 (~100 μg/m³) in northern India, especially near New Delhi. These high PM2.5 concentrations in the Indo-Gangetic plain are driven in large part from the seasonal burning of crop residue and meteorological conditions typical at this time of the year, such as low wind speeds and a shallow boundary layer. While the satellite-derived PM2.5 moderately replicates (R = ~0.7-0.9) the spatial variability in the two-month mean of surface in situ PM2.5 from monitoring sites operated by the Central and State Pollution Control Boards, we show results from specific scenes for which there are large deviations between the satellite-derived PM2.5 and in situ measurements. Other current work on this topic focuses on developing PM2.5 estimates using airborne high spectral resolution lidar measurements through machine learning regression algorithms and involves several parameters (e.g., aerosol extinction, color ratio, lidar ratio). Application of this method over major metropolitan areas in the US and Asia have resulted in high correlations (R = 0.93) with surface measurements. This airborne lidar approach can be adapted to spaceborne lidar measurements, and all three of these approaches can be applied to ESA’s EarthCARE Atmospheric Lidar instrument, setting the stage for the future Cloud Aerosol Lidar for Global Scale Observations of the Ocean-Land Atmosphere System (CALIGOLA) mission. Ultimately, beyond estimates of PM2.5, the aerosol vertical distribution from lidars can benefit studies involving passive sensor approaches for PM2.5 proxies (including from geostationary satellites), wildfire smoke plume injection heights, volcanic emissions (e.g., ash height retrievals), and aerosol/air quality model assimilation, evaluation, and forecasts.
Extreme weather events, including heatwaves, heavy precipitation, and drought, have a large impact on society through human health, destruction of infrastructure, ecological change, and economic losses. Reanalyses such as NASA’s Modern Era Retrospective Analysis, version 2 (MERRA-2) are a valuable tool for analyzing past extreme events to determine their underlying causes and how extremes have changed over the past four decades. The detection of extreme events relies on a threshold for precipitation or temperature that is derived using a reference period, which can then be used to determine how extreme an event was or what the return period is. Operational centers typically use a 30-year climatology period that shifts in time every ten years, while the World Meteorological Organization suggests that the maximum amount of data should be included for the detection of extreme events due to their rare occurrence. As global and regional climate continues to change, the interpretation of extreme events is reliant on the baseline period that is used for the underlying thresholds and can be a source of uncertainty for the policy making community. Three baseline periods – 1981-2010, 1991-2020, and 1981-2020 – will be used to compute percentiles of temperature and precipitation across the contiguous United States and will then by employed to determine monthly indices representing heatwaves, cold spells, and extreme precipitation events. A spatial and temporal analysis of the resulting extreme weather indices will demonstrate the appropriateness for each baseline period for the evaluation of extreme events.
Key questions to which SONEX was directed were the following: Can aircraft corridors be detected? Is there a unique tracer for aircraft NO(x)? Can a "background" NO(x) (or NO(y) be defined? What fraction of NO(x) measured during SONEX was from aircraft? How representative was SONEX of the North Atlantic in 1997 and how typical of other years? We attempt to answer these questions through species-species correlations, probability distribution functions (PDFs), and meteorological history. There is not a unique aircraft tracer, largely due to the high variability of air mass origins and tracer ratios, which render "average" quantities meaningless. The greatest NO and NO(y) signals were associated with lightning and convective NO sources. Well-defined background CO, NO(y) and NO(y)/ozone ratio appear in subsets of two cross-track flights with subtropical origins and five flights with predominantly mid-latitude air. Forty percent of the observations on these 7 flights showed NO(y)/ozone to be above background, evidently due to unreacted NO(x). This NO(x) is a combination of aircraft, lightning and surface pollution injected by convection. The strongly subtropical signatures in SONEX observations, confirmed by pv (potential vorticity) values along flight tracks, argues for most of the unreacted NO(x) originating from lightning. Potential vorticity statistics along SONEX flight tracks in 1992-1998, and for the North Atlantic as a whole, show the SONEX meteorological environment to be representative of the North Atlantic flight corridor in the October-November period.
Planetary Boundary Layer (PBL) parameterization schemes are employed to handle subgrid-scale processes on atmospheric models, playing a key role in accurately representing the atmosphere. Recent studies have shown that PBL schemes are particularly fundamental to the depiction of PBL height (PBLH), especially over the Amazon. In the present study, we investigated the performance of PBL schemes on the representation of meteorological variables, turbulent fluxes, PBL vertical structures, and PBLH over the central Amazon basin under dry conditions, taking advantage of observations from the Observations and Modeling of the Green Ocean Amazon campaign (GoAmazon2014/5) for validation and evaluation. Numerical experiments were carried out within the WRF model using eight PBL schemes for two dry periods from 2014 (typical year) and 2015 (El-Niño year), and results from the 1-km resolution domain were directly compared to hourly in situ observations. In general, all PBL schemes present good performance to reproduce meteorological variables, with nonlocal (local) PBL schemes producing better performance in the 2014 (2015) study period. All PBL schemes in general overestimate (>100%) daytime turbulent fluxes. Thermodynamic (daytime) vertical structures are better predicted than mechanical (nocturnal) ones. The local MYNN2.5 scheme showed the overall best performance for PBLH prediction, mainly at night.
Climate and population change are known to influence electricity demand, but what is the impact of uncertainty in climate and population projections on electricity demand in the United States (U.S.) over the next 30 years? This question has important implications for investment decisions in the energy sector, which are typically made using a 15- to 30-year time horizon. Simply put, if future climate and population scenarios do not lead to meteorological conditions and subsequent energy demands that are distinctly different within the first 30 years then, for the purposes of investment decisions, it may not matter which potential pathway we are most likely on. The Integrated, Multisector, Multiscale Modeling (IM3) project has generated a wide, yet plausible range of 21st century high-resolution climate and population scenarios for the U.S. The IM3 projections span two climate scenarios (Representative Concentration Pathways 4.5 and 8.5) and two population scenarios (Shared Socioeconomic Pathways 3 and 5). For each of the climate scenarios, we reflect a range of climate model uncertainty by using boundary conditions from a set of climate models that are hotter and colder than the multi-model mean. In total there are eight (2 x 2 x 2) IM3 scenarios. This work explores a basic question: When do future climate and energy outcomes start to meaningfully diverge across the eight scenarios? The analysis is done on both the raw meteorology time-series from each scenario as well as a time-series of projected total electricity demand generated using IM3's Total ELectricity Loads (TELL) model. We also explore the spatial heterogeneity of the divergence signal to identify regions of the country that may be more or less path dependent.