Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “transducer error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Comparative study of 0° X-cut and Y + 36°-cut lithium niobate high-voltage sensing

A comparison study between Y + 36° and 0° X-cut lithium niobate (LiNbO{sub 3}) was performed to evaluate the influence of crystal cut on the acoustic propagation to realize a piezoelectric high-voltage sensor. The acoustic time-of-flight for each crystal cut was measured when applying direct current (DC), alternating current (AC), and pulsed voltages. Results show that the voltage-induced shift in the acoustic wave propagation time scaled quadratically with voltage for DC and AC voltages applied to X-cut crystals. For the Y + 36° crystal, the voltage-induced shift scales linearly with DC voltages and quadratically with AC voltages. When applying 5 μs voltage pulses to both crystals, the voltage-induced shift scaled linearly with voltage. For the Y + 36° cut, the voltage-induced shift from applying DC voltages ranged from 10 to 54 ps and 35 to 778 ps for AC voltages at 640 V over the frequency range of 100 Hz–100 kHz. Using the same conditions as the Y + 36° cut, the 0° X-cut crystal sensed a shift of 10–273 ps for DC voltages and 189–813 ps for AC voltage application. For 5 μs voltage pulses, the 0° X-cut crystal sensed a voltage induced shift of 0.250–2 ns and the Y + 36°-cut crystal sensed a time shift of 0.115–1.6 ns. This suggests a frequency sensitive response to voltage where the influence of the crystal cut was not a significant contributor under DC, AC, or pulsed voltage conditions. The measured DC data were compared to a 1-D impedance matrix model where the predicted incremental length changed as a function of voltage. When the voltage source error was eliminated through physical modeling from the uncertainty budget, the combined uncertainty of the sensor (within a 95% confidence interval) decreased to 0.0033% using a Y + 36°-cut crystal and 0.0032% using an X-cut crystal for all the voltage conditions used in this experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wideband Disturbance Accomodation in Precision Flexible Space Structures

Numerous spacecraft missions currently being formulated exhibit several basic and sharply conflicting features: selected components (e.g., an optical train) of inherently flexible structures are to maintain precision pointing performance in a wideband disturbance environment. Within the overall process of synthesizing an active controller to deal with this difficult problem, the aspects of reduced-order modelling and of actuator and sensor selection are crucial to the successful implementation of any controller feedback strategy. The principal focus in this paper is on the influence of actuator and sensor selection upon the effectiveness of a specified controller strategy for wideband disturbance accommodation. A genetic optical support structure is used for a number of design examples. Active transducer selections are made systematically based upon their direct contributuion to optical pointing error. Controller designs incorporating the various transducer selections exhibit stability in the presence of unmodeled modes over a frequency range substantially beyond the bandwidth of the disturbance.

Hegg, D. R.↗

Simultaneous moisture content and mass flow measurements in wood chip flows using coupled dielectric and impact sensors

An 8-electrode capacitance tomography (ECT) sensor was built and used to measure moisture content (MC) and mass flow of pine chip flows. The device was capable of directly measuring total water quantity in a sample but was sensitive to both dry matter and moisture, and therefore required a second measurement of mass flow to calculate MC. Two means of calculating the mass flow were used: the first being an impact sensor to measure total mass flow, and the second a volumetric approach based on measuring total area occupied by wood in images generated using the capacitance sensor’s tomographic mode. Tests were made on 109 groups of wood chips ranging in moisture content from 14% to 120% (dry basis) and wet weight of 280 to 1100 g. Sixty groups were randomly selected as a calibration set, and the remaining were used for validation of the sensor’s performance. For the combined capacitance/force transducer system, root mean square errors of prediction (RMSEP) for wet mass flow and moisture content were 13.42% and 16.61%, respectively. RMSEP using the combined volumetric mass flow/capacitance sensor for dry mass flow and moisture content were 22.89% and 24.16%, respectively. Either of the approaches was concluded to be feasible for prediction of moisture content in pine chip flows, but combining the impact and capacitance sensors was easier to implement. As a result, in situations where flows could not be impeded, however, the tomographic approach would likely be more useful.

09 BIOMASS FUELS↗

Interpolation Errors in Spectrum Analyzers

To obtain the proper measurement amplitude with a spectrum analyzer, the correct frequency-dependent transducer factor must be added to the voltage measured by the transducer. This report examines how entering transducer factors into a spectrum analyzer can cause significant errors in field amplitude due to the misunderstanding of the analyzer's interpolation methods. It also discusses how to reduce these errors to obtain a more accurate field amplitude reading.

Martin, J. L.↗

Controlling optical-cavity locking using reinforcement learning

Abstract This study applies an effective methodology based on Reinforcement Learning to a control system. Using the Pound–Drever–Hall locking scheme, we match the wavelength of a controlled laser to the length of a Fabry-Pérot cavity such that the cavity length is an exact integer multiple of the laser wavelength. Typically, long-term drift of the cavity length and laser wavelength exceeds the dynamic range of this control if only the laser’s piezoelectric transducer is actuated, so the same error signal also controls the temperature of the laser crystal. In this work, we instead implement this feedback control grounded on Q-Learning. Our system learns in real-time, eschewing reliance on historical data, and exhibits adaptability to system variations post-training. This adaptive quality ensures continuous updates to the learning agent. This innovative approach maintains lock for eight days on average.

47 OTHER INSTRUMENTATION↗

Design and analysis of a torsion braid pendulum displacement transducer

The dynamic properties at various temperatures of braids impregnated with polymer can be measured by using the braid as the suspension of a torsion pendulum. This report describes the electronic and mechanical design of a torsional braid pendulum displacement transducer which is an advance in the state of the art. The transducer uses a unique optical design consisting of refracting quartz windows used in conjunction with a differential photocell to produce a null signal. The release mechanism for initiating free torsional oscillation of the pendulum has also been improved. Analysis of the precision and accuracy of the transducer indicated that the maximum relative error in measuring torsional amplitude was approximately 0. A serious problem inherent in all instruments which use a torsional suspension was analyzed: misalignment of the physical and torsional axes of the torsional member which results in modulation of the amplitude of the free oscillation.

Rind, E.↗

Compensation circuit improves operation of inductive coupling transformers

Circuitry eliminates undesirable modulation effects in rotary transformers which transfer electrical energy to and from angular rate transducers on a gyroscope. It cancels the error by feeding back compensation signals through a tertiary winding on the stator of the output rotary transformer.

Source record↗

DSN research and technology support

The activities of the Venus Station (DSS 13) and the Microwave Test Facility (MTF) during the period October 11, 1976, through February 13, 1977, are discussed. A significant effort on implementation of equipment for the planned conversion of DSS 13 to unattended operation is discussed. The Receiver and Microwave Subsystem are near completion, and the new feedcone and position encoders are implemented onto the 26-m antenna. Support of the 400-kW X-band radar, located at DSS 14, is reported, and the activities of the DSN High Power Transmitter Maintenance Facility (HPTMF), located at DSS 13 and MTF, are discussed. The successful completion of the first series of observations planned for VLBI validation is reported and significant station maintenance activities are covered. Clock synchronization transmissions to DSS 43 and DSS 63 are reported, and an evaluation of any pointing errors in the 26-m antenna position transducer are made.

Jackson, E. B.↗

Self-sensing piezoelectric actuation - Analysis and application to controlled structures

Issues related to modeling and implementation of a self-sensing piezoelectric actuator are investigated. The necessary formulation for modeling the simultaneous sensing and actuation phenomenon is provided. Open and closed loop experiments performed on a cantilevered beam test specimen are described. The sensitivity of the results to representative errors introduced in the implementation of the transducer is demonstrated analytically and experimentally. The self-sensing actuator is also implemented using an active piezoelectric strut in a truss structure.

Anderson, Eric H.↗

A high-precision miniaturized rotating coil transducer for magnetic measurements

A miniaturized Printed Circuit Board (PCB) sensing coil, jointly developed by CERN and Fermilab for measuring the field of small-gap (less than 10 mm) accelerator magnets, is illustrated. A sensing coil array, with a scheme for compensating the main field when measuring the harmonic error components, hosted on a synthetic sapphire-based transducer, is presented. Key innovating features are (i) very-small size, both for the sensing coil array (thickness of 1.380 mm) and for the transducer (overall diameter of 7.350 mm), (ii) metrological performance, namely accuracy (more than five times better than state of the art), and 1-sigma repeatability (ten times better on harmonics with amplitude less than 100 ppm), and (iii) manufacturing technology of both the coil array (13 double layers aligned within 10 μm), and the sapphire support (concentricity, the most important uncertainty source for rotating coils, 3 μm of uncertainty, namely one order of magnitude better than fiberglass support). After stating the measurement problem, the design of the transducer and a case study of a two-layer PCB sensor array are also illustrated. Then, the prototyping and quality control of both the sensor and the transducer are discussed. Furthermore, the calibration and the results obtained with a prototype setup at Fermilab are presented. Finally, in the appendix, the theory of the rotating coil, the sensor geometry, and the harmonic compensation are briefly reviewed for the reader easiness.

06.20.fb/calibration↗

Ultrasonic dispersion determined from mechanical resonance frequency shifts

With standing wave ultrasonic techniques, small changes in phase velocity which result from changes in some external parameter (e.g., temperature or magnetic field) have traditionally been determined by observing shifts in the mechanical resonance frequency of a composite resonator. Some previous investigators have assumed that the fractional change in velocity is equal to the fractional change in frequency. We discuss quantitatively the errors involved in such an approach, showing that it leads to substantial inaccuracies when the loading effect of the transducer(s) cannot be neglected. Substantially improved formulas for determining the dispersion are presented and one of these is shown to be much more accurate than all previous approximations. The results of simulated and actual experiments over wide ranges of dispersion, transducer loading parameter, and frequency are analyzed in order to compare the errors inherent in the various approximations.

Moerner, W. E.↗

Three-point bridge calibration with one resistor

Method calibrates transducer bridge curing unbalanced condition and line resistance errors are negligible. Series resistance method can be automated easily and controlled by 2-bit information source which provide 4 states for switches.

Harrison, D. R.↗

Apollo 16, LM-11 descent propulsion system final flight evaluation

The performance of the LM-11 descent propulsion system during the Apollo 16 missions was evaluated and found satisfactory. The average engine effective specific impulse was 0.1 second higher than predicted, but well within the predicted one sigma uncertainty of 0.2 seconds. Several flight measurement discrepancies existed during the flight as follows: (1) the chamber pressure transducer had a noticeable drift, exhibiting a maximum error of about 1.5 psi at approximately 130 seconds after engine ignition, (2) the fuel and oxidizer interface pressure measurements appeared to be low during the entire flight, and (3) the fuel propellant quantity gaging system did not perform within expected accuracies.

Avvenire, A. T.↗

An improved back projection algorithm of ultrasound tomography

Binary logic back projection algorithm is improved in this work for the development of fast ultrasound tomography system with a better effect of image reconstruction. The new algorithm is characterized by an extra logical value ‘2’ and dual-threshold processing of collected raw data. To compare with the original algorithm, a numerical simulation was conducted by the verification of COMSOL simulations formerly, and then a set of ultrasonic tomography system is established to perform the experiments of one, two and three cylindrical objects. The object images are reconstructed through the inversion of signals matrix acquired by the transducer array after a preconditioning, while the corresponding spatial imaging errors can obviously indicate that the improved back projection method can achieve modified inversion effect.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Rocketdyne automated dynamics data analysis and management system

An automated dynamics data analysis and management systems implemented on a DEC VAX minicomputer cluster is described. Multichannel acquisition, Fast Fourier Transformation analysis, and an online database have significantly improved the analysis of wideband transducer responses from Space Shuttle Main Engine testing. Leakage error correction to recover sinusoid amplitudes and correct for frequency slewing is described. The phase errors caused by FM recorder/playback head misalignment are automatically measured and used to correct the data. Data compression methods are described and compared. The system hardware is described. Applications using the data base are introduced, including software for power spectral density, instantaneous time history, amplitude histogram, fatigue analysis, and rotordynamics expert system analysis.

Tarn, Robert B.↗

Picosecond magneto-optic thermometry measurements of nanoscale thermal transport in AlN thin films

The thermal conductivity Λ of wide bandgap semiconductor thin films, such as AlN, affects the performance of high-frequency devices, power devices, and optoelectronics. However, accurate measurements of Λ in thin films with sub-micrometer thicknesses and Λ > 100 W m -1 K -1 is challenging. Widely used pump/probe metrologies, such as time–domain thermoreflectance (TDTR) and frequency–domain thermoreflectance, lack the spatiotemporal resolution necessary to accurately quantify thermal properties of sub-micrometer thin films with high Λ. In this work, we use a combination of magneto-optic thermometry and TiN interfacial layers to significantly enhance the spatiotemporal resolution of pump/probe thermal transport measurements. We use our approach to measure Λ of 100, 400, and 1000 nm AlN thin films. We coat AlN thin films with a ferromagnetic thin-film transducer with the geometry of (1 nm-Pt/0.4 nm-Co) x3 /(2 nm-TiN). This PtCo/TiN transducer has a fast thermal response time of <50 ps, which allows us to differentiate between the thermal response of the transducer, AlN thin film, and substrate. For the 100, 400, and 1000 nm thick AlN films, we determine Λ to be 200 ± 80, 165 ± 35, and 300 ± 70 W m -1 K -1 , respectively. We conclude with an uncertainty analysis that quantifies the errors associated with pump/probe measurements of thermal conductivity, as a function of transducer type, thin-film thermal conductivity, and thin-film thickness. Time resolved magneto-optic Kerr effect experiments can measure films that are three to five times thinner than is possible with standard pump/probe metrologies, such as TDTR. This advance in metrology will enable better characterization of nanoscale heat transfer in high thermal conductivity material systems like wide bandgap semiconductor heterostructures and devices.

36 MATERIALS SCIENCE↗