Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “total harmonic distortion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

27 records · Page 2

Medium Voltage Testbed for Comparing Advanced Power Line Sensors vs. Transformers with Electrical Grid Events

Electrical utilities have relied upon potential transformers (PTs) and current transformers (CTs) for very accurate metering and to provide reliable signals for protective relays. These devices measure phase voltages and currents and are commissioned by electrical engineers. PTs/CTs can detect and react to various electrical anomalies that could adversely affect electrical grid operations. Less expensive alternative sensing technologies offer the possibility of wider deployment, particularly in grids that employ distributed energy resources. In this work, the performance of an advanced medium-voltage sensor is compared with that of a reference PT and a CT and experimentally evaluated for different power grid scenarios on an advanced outdoor power line sensor testbed at the U.S. Department of Energy’s Oak Ridge National Laboratory. The sensor is based on a capacitive divider for voltage monitoring and a Rogowski coil with an integrator for current monitoring. This study simulated a power grid model based on a utility circuit at the Riverside EPB of Chattanooga. The simulation circuit was created with MATLAB/Simulink software and was integrated into an RT-LAB project to run with the OP4510 real-time simulator at the OPLST. During the tests, the real-time simulations were run for 40 s, and the signal to record the test event with the power meter was set at 30 s for the event-trigger circuit. The advanced outdoor power line sensor testbed has a real-time simulator that is used to generate transient scenarios (e.g., electrical faults, capacitor bank operation, and service restoration), while the analog signals are recorded by the same high-resolution power meter. The behaviors of analog signals, harmonic components, total harmonic distortion, and crest factors are assessed for this power line sensor and compared with those of the reference PT/CT because of the absence of testing standards for advanced outdoor power line sensors. The results showed that this OPLS technology responded identically to the PT and CT under all conditions.

Piesciorovsky, Emilio [ORNL]↗

SVM-Based Synchronized Fault Detection for 100% Renewable Microgrids: Preprint

Traditional protection schemes face significant challenges when applied to microgrids with high penetrations of renewables with inverter-based resources (IBRs). The proliferation of advanced sensing and communication technologies has generated copious data, offering an opportunity to overcome these limitations using data-driven machine learning approaches. This work proposes a novel approach based on a support vector machine (SVM) for detecting faults within a 100% renewable microgrid. The approach encompasses a systematic offline training stage for the development of a linear SVM-based fault detection algorithm. This process covers offline data collection from the microgrid under study, the extraction of features such as positive- and negative-sequence components and the total harmonic distortion of the voltage and current measurements of the relays, and the design of the linear SVM-based classifier. During the online implementation, however, different classifiers can exhibit asynchronicity in detecting the fault inception at different subcycle-to-cycle period-level delays. To circumvent this asynchronicity issue, a separate algorithm is developed for each relay to estimate the fault inception time as close to the real fault time. The performance of the proposed SVM-based synchronized fault detection method is evaluated using online time-domain simulation studies on a microgrid test system. The results corroborate the reliability of the fault detection scheme when tested under various fault cases (fault types, locations, and impedances) and non-fault cases during both grid-tied and islanded operation modes.

100% microgrid↗

Propulsion System Design using a Dual 3-Phase PM Synchronous Reluctance Machine with X-Type Multi-Level GaN Inverter

— A propulsion system design is exhibited here that comprises of an X-type GaN power module based dual multi-level inverter and a PM Synchronous Reluctance motor. With the critical benefits of multi-level operation, namely low common mode EMI noise, low switching loss, low current Total Harmonic Distortion (THD), smoother torque and lower iron loss, this topology targets high system-level efficiency and high power density while using reduced rare earth (RE) elements in its motor. General Motors and Purdue University jointly designed and developed this 800V class, highly scalable traction drive that can deliver 200+ kW of power suitable for C-SUV to truck vehicle class. The 3-phase electric machine design utilizes dual winding with 6 terminals to work in line with the GaN X-type inverter, and results in a tractive solution that ensures higher machine efficiency while reducing cost and uncertainty related to use and availability of heavy rare earth/rare earth elements in its rotor.

MOMEN, FAIZUL [General Motors LLC, Detroit, MI (Un↗

A Framework to Evaluate the Grid Impacts of EV Fleet Charging Solutions

Growing Electric vehicle (EV) adoption in residential and commercial applications is driving the need for the charging infrastructures required to fulfill the charging needs. The resulting increase in demand for electric power will add a significant load to the electric grid, which could negatively impact the grid operation. EVs are power electronic loads and draw harmonic currents which can lead to a host of power quality issues. Therefore, it is crucial to assess the grid impacts and management of EV charging loads to ensure the reliable operation of the electric grid. In this paper, we develop a framework to help determine power-quality impacts given an EV charging schedule on the system. We compare the performance of unmanaged and managed charging solutions on factors like voltage drop, flicker, harmonic distortion and the peak site load - based on the EV depot in Hazelwood school district. The results allow insights into operation and site design of EV depots.

ADVANCED PROPULSION SYSTEMS,POWER TRANSMISSION AND↗

Analysis of Transformer Magnetizing Reactance Using Describing Function in Direct Power Control of Back-to-Back Modular Multilevel Converter with Advanced Grid Support

This paper presents a Port Controlled Hamiltonian based direct power control architecture for a back-to-back modular multilevel converter system connecting two ac sources at different frequencies. The system features advanced grid support functionalities based on IEEE 1547-2018, implemented on the inverter side. The rectifier side controller ensures reference following for active and/or reactive powers and maintains the commanded dc bus voltage. The inverter side controller ensures power command following for active and reactive powers.The proposed control architecture is designed to suppress second harmonic oscillations in powers during unbalanced grid voltage sags by dynamically adjusting the currents on each ac side. This also ensures effective elimination of any second harmonic oscillations in the equivalent dc bus voltage. Validation is performed on an OPAL-RT real-time platform with case studies on unbalanced and balanced sags, demonstrating the controller's effectiveness during real time implementation. A reduced-scale laboratory prototype further verifies these case studies, with experimental results for balanced sags due to grid simulator limitations. The results confirm the robustness and efficiency of the proposed control strategy in ensuring stable and reliable operation under various grid conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Benchmarking Real-Time Control Platforms Using a Matlab/Simulink Coder with Applications in the Control of DC/AC Switched Power Converters

In the control of DC/AC switched power converters (SPC), one of the most important aspects to be considered is the selection of the real-time control platform. The real-time control platform must be able to meet the high performance efficiency and regulation requirements of the DC/AC SPC, as these typically operate at switching frequencies in the order of kHz to MHz. For this reason, the hardware characteristics of the ADC and PWM, and the processing capacity of the real-time control platform are of vital importance when implementing advanced digital controllers that maintain voltage and current levels within regulatory standards. In this context, we aimed to perform a comparative study of the computation times of different real-time control platforms when implementing different control strategies for DC/AC switched power converters. We also analyzed the impact of the real-time control platforms on the THD of the voltages generated by the DC/AC switched power converters. With the help of this paper, researchers and developers will have criteria to select which real-time control platform to use in real-time control for DC/AC SPC applications.

42 ENGINEERING↗

Near-field radiative heat transfer between irregularly shaped dielectric particles modeled with the discrete system Green's function method

Near-field radiative heat transfer (NFRHT) between irregularly shaped dielectric particles made of SiO 2 and morphology characterized by Gaussian random spheres is studied. Particles are modeled using the discrete system Green's function (DSGF) approach, which is a volume integral numerical method based on fluctuational electrodynamics. This method is applicable to finite, three-dimensional objects, and all system interactions are defined independent of thermal excitation by a generalized system Green's function. The DSGF method is deemed suitable to model NFRHT between irregularly shaped particles after verification against the analytical solution for chains of two and three SiO 2 spheres. The NFRHT results reveal that geometric irregularity in particles leads to a reduction of the total conductance from that of comparable perfect spheres at vacuum separation distances smaller than the particle size, a regime in which NFRHT is a surface phenomenon. At vacuum separation distances larger than the particle size, NFRHT becomes a volumetric process, and the total conductance between irregularly shaped particles converges to that of comparable perfect spheres. Spectral analysis reveals, however, that particle irregularity leads to damping and broadening of resonances at all separation distances, thereby highlighting the importance of the DSGF method for spectral engineering in the near field. The reduced spectral coherence when particle size is larger than the vacuum separation distance is attributed to coupling of surface phonon-polaritons within the randomly generated, distorted particle features. For particle size smaller than the vacuum separation distance, resonance broadening and damping are linked with the multiple localized surface phonon modes supported by the composite spherical harmonic morphologies of the Gaussian random spheres. In conclusion, this paper has direct implications for thermal management of packed particle systems, with applications in radiative property control, electronics, energy conversion, and nanomanufacturing.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Multifunctional Cu 2 TSiS 4 (T = Mn and Fe): Polar Semiconducting Antiferromagnets with Nonlinear Optical Properties

In this work, Cu 2 TSiS 4 (T = Mn and Fe) polycrystalline and single-crystal materials were prepared with high-temperature solid-state and chemical vapor transport methods, respectively. The polar crystal structure (space group Pmn2 1 ) consists of chains of corner-sharing and distorted CuS 4 , Mn/FeS 4 , and SiS 4 tetrahedra, which is confirmed by Rietveld refinement using neutron powder diffraction data, X-ray single-crystal refinement, electron diffraction, energy-dispersive X-ray spectroscopy, and second harmonic generation (SHG) techniques. Magnetic measurements indicate that both compounds order antiferromagnetically at 8 and 14 K, respectively, which is supported by the temperature-dependent (100–2 K) neutron powder diffraction data. Additional magnetic reflections observed at 2 K can be modeled by magnetic propagation vectors k = (1/2,0,1/2) and k = (1/2,1/2,1/2) for Cu 2 MnSiS 4 and Cu 2 FeSiS 4 , respectively. The refined antiferromagnetic structure reveals that the Mn/Fe spins are canted away from the ac plane by about 14°, with the total magnetic moments of Mn and Fe being 4.1(1) and 2.9(1) μ B , respectively. Both compounds exhibit an SHG response with relatively modest second-order nonlinear susceptibilities. Density functional theory calculations are used to describe the electronic band structures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗