Engineering PapersSearch

SEARCH · Engineering Papers

Results for “tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Multi-slice electron ptychographic tomography for three-dimensional phase-contrast microscopy beyond the depth of focus limits

Electron ptychography is a powerful computational method for atomic-resolution imaging with high contrast for weakly and strongly scattering elements. Modern algorithms coupled with fast and efficient detectors allow imaging specimens with tens of nanometers thicknesses with sub-0.5 Ångstrom lateral resolution. However, the axial resolution in these approaches is currently limited to a few nanometers, limiting their ability to solve novel atomic structures ab initio. Here, we experimentally demonstrate multi-slice ptychographic electron tomography, which allows atomic resolution three-dimensional phase-contrast imaging in a volume surpassing the depth of field limits. We reconstruct tilt-series 4D-STEM measurements of a $\mathrm{Co_3O_4}$ nanocube, yielding 2 Å axial and 0.7 Å transverse resolution in a reconstructed volume of $\mathrm{(18.2\,nm)^3}$. Our results demonstrate a 13.5-fold improvement in axial resolution compared to multi-slice ptychography while retaining the atomic lateral resolution and the capability to image volumes beyond the depth of field limit. Multi-slice ptychographic electron tomography significantly expands the volume of materials accessible using high-resolution electron microscopy. We discuss further experimental and algorithmic improvements necessary to also resolve single weakly scattering atoms in 3D.

36 MATERIALS SCIENCE

Error-mitigated nonorthogonal quantum eigensolver via shadow tomography

We present a shadow-tomography-enhanced nonorthogonal quantum eigensolver (NOQE) for more efficient and accurate electronic structure calculations on near-term quantum devices. By integrating shadow tomography into the NOQE, the measurement cost scales linearly rather than quadratically with the number of reference states, while also reducing the required qubits and circuit depth by half. This approach enables extraction of all matrix elements via randomized measurements and classical postprocessing. We analyze its sample complexity and show that, for small systems, it remains constant in the high-precision regime, while for larger systems, it scales linearly with the system size. We further apply shadow-based error mitigation to suppress noise-induced bias without increasing quantum resources. Demonstrations on the hydrogen molecule in the strongly correlated regime achieve chemical accuracy under realistic noise, showing that our method is both resource-efficient and noise-resilient for practical quantum chemistry simulations in the near term.

quantum algorithms & computation

Errors in reconstruction of dichroic X-ray orientation tomography due to polarization rotation of the incident beam

Dichroic X-ray tomography is a technique in which the crystal orientation or magnetization of a sample is resolved in three dimensions. The best-known uses of this technique are for observation of magnetic moments via circular dichroism, using left- and right-handed circularly polarized X-ray beams. Another variant uses linear dichroism to resolve the crystal orientation. In both these techniques, it is assumed that the absorption of X-rays along a path inside a material can be computed as a line integral of a local absorption coefficient along the ray path. For linear dichroism, this assumption is inaccurate because the polarization of the beam changes along the propagation direction when the optic axis of the material is not aligned along the polarization. In this work, a finite-element Maxwell solver is used to simulate tomography and reconstructions. The propagation effect can lead to significant errors in the reconstructed orientations. These errors may be mitigated by taking data at additional angles or by operating at energies at which the dichroism is weak. An iterative approach is proposed which may allow accurate reconstruction with fewer data than would otherwise be required.

X-ray linear dichroism

Acoustic Tomography System (CRADA Final Report)

NREL will install the CU/CIRES acoustic tomography array at the National Wind Technology Center (NWTC). The system consists of 9 freestanding towers of 9.1m height that are currently located at the NWTC. On these towers are installed a series of microphones and speakers. One center tower holds a sonic anemometer and temperature probe. The purpose of the acoustic tomography system is to measure complex flow fields surrounding wind turbine arrays that influence wind farm energy production and reliability. There is currently no funding to test and research the system (just install it), but NREL and CU researchers will write proposals that will fund the actual research with this unique measurement technology.

17 WIND ENERGY

Wake-Resolving Acoustic Tomography: Advances through Numerical Covariance Methods

Acoustic tomography offers path-integrated measurements of atmospheric velocity and temperature fluctuations with high spatial resolution. Classical implementations of time-dependent stochastic inversion rely on homogeneous, isotropic covariance models that are poorly suited to the anisotropic structure of wind turbine wakes. By directly estimating heterogeneous covariances from large-eddy simulations (LESs) into the time-dependent stochastic inversion operator, we relax implicit assumptions in the analytical models used historically. Retrievals using these LES-informed models improve agreement with true fields in variance, turbulent kinetic energy, and spectral content compared to analytical and precursor-based covariance models. The results indicate that LES-informed covariance models can enhance the accuracy of acoustic tomography retrievals in complex, anisotropic flows such as wind turbine wakes in some cases and highlight instances where analytical models still offer competitive performance, despite their simplifying assumptions.

17 WIND ENERGY

3D pore structure reconstruction of fluff region in top of EBR-II irradiated fuel by X-ray micro-computed tomography

Metallic fuels comprised of U-Zr binary and U-Pu-Zr ternary alloys are a promising fuel candidate for sodium-cooled fast reactors and possess many advantages over ceramic fuels such as higher uranium density and improved thermal conductivity. Fluff is a highly porous structure forming at the top of metallic fuel slugs during irradiation and was extensively observed in past sodium-cooled fast reactor (SFR) experiments such as Idaho National Laboratory’s Experimental Breeder Reactor II (EBR-II). Previous investigations have shown that fluff is rich in fissile atoms and hence could have neutronics implications, but its formation mechanisms are not understood. In this work, two cube-shaped lift outs were taken from the fluff and bulk fuel regions of a high burnup U-19Pu-10Zr composition EBR-II fuel slug and characterized by micro computed tomography (Micro-CT) and energy dispersive x-ray spectroscopy (EDS). This was used to characterize differences in microscale porosity and composition between fluff and bulk fuel, and to support or oppose postulated fluff formation mechanisms. Surface EDS showed minimal differences between the elemental compositions of the fluff and fuel cubes. However, three-dimensional (3D) pore analysis from the tomography scans showed significant differences between the fluff and fuel cube pore size distributions at the microscale level. The high porosity and irregular pore distribution seen in macroscale fluff was also present within the micro-scale fluff cube, having a much higher porosity than the fuel cube which was concentrated in a few large pore networks. In conclusion, these results indicate support for a creep driven mechanism of fluff formation.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Optimal 3D chemical imaging with multimodal electron tomography

Accurate mapping of nanoscale chemistry in three dimensions (3D) has been a longstanding challenge. Modern electron microscopy provides chemical images by electron energy loss spectroscopy (EELS) and energy dispersive x-ray spectrometry (EDX) but requires high fluences that damage specimens. In 3D, the requirements are worse; electron tomography demands many high-fluence chemical maps for reconstruction, creating a tradeoff between resolution, accuracy, and sample survival. Fused multimodal electron tomography (MM-ET) alleviates this requirement by leveraging lower-fluence high-angle annular dark-field (HAADF) images alongside a few chemical maps to dramatically improve chemical resolution. Here, experimental and computational parameter space is systematically explored to determine when MM-ET performs best. Ideal imaging conditions balance sample survival with resolution and chemical specificity; we recommend a tilt range of at least ± 70°, acquiring 40 equally spaced HAADF projections (signal-to-noise > 10), and 7 EELS/EDX maps of each chemistry (signal-to-noise > 4).

36 MATERIALS SCIENCE

X-ray tomography of damage dynamics in advanced materials using a laser wakefield accelerator

Additively manufactured (AM) metals offer the potential for customizable, cost-effective components, but qualification and certification are crucial. Key to this process is understanding pore dynamics under stress, typically analyzed using micro-computed tomography. This study introduces laboratory-scale “betatron” x-rays from laser wakefield acceleration as a high-throughput alternative for x-ray tomography of advanced materials, such as AM AlSi10Mg alloys. Coupled with 3D finite element modeling, this method provides detailed insights into stress-porosity interactions. The approach delivers high-resolution scans, revealing that pore shape and local triaxiality significantly influence fracture dynamics, supporting advanced material characterization. This work also demonstrates the potential and versatility of laser-betatron x-ray μCT for generating large datasets to accelerate our understanding of the stochastic, process-specific nature of pore formation in AM alloys.

Senthilkumaran, Vigneshvar

Use of Constrained Gamma Emission Computed Tomography to Evaluate Fission Product Distributions in High-Temperature Materials from a TRISO Fuel Irradiation

An image reconstruction technique was developed to overcome problems with earlier methods of gamma emission computed tomography of graphite rings surrounding the AGR-3/4 TRISO fission product transport experiment. The profiles obtained from the tomography are compared with sampling done via radially resolved destructive sampling techniques. Generally, there is good agreement between profiles measured via destructive sampling of the rings and the tomographic profiles, though at low signal strengths, the tomographic profiles appear elevated.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Strategies for preparing and analyzing thin passive films with atom probe tomography

Atom probe tomography provides a unique, three-dimensional map of elemental and isotopic distributions over a wide range of materials with near-atomic scale resolution and is particularly strong at analyzing buried interfaces within materials. However, it is much more difficult to apply atom probe to the analysis of nanoscale surface films, such as those formed during alloy passivation, where unique challenges persist for sample preparation and data collection. Here, we present sample preparation strategies involving the deposition of a < 100 nm capping layer that enables reliable characterization of thin passive films approximately 2–5 nm thick formed on binary and multi-principal element alloys via atom probe tomography. Several capping layer materials (Pt, Ti, Ni/Cr bi-layer) and deposition methods are contrasted. Our results indicate a sputtered Ni/Cr bi-layer enables the characterization of the entire passive film and concentration profiles that can easily be interpreted to clearly distinguish base alloy/passive film/capping layer interfaces. Lastly, we highlight ongoing challenges and opportunities for this experimental approach.

Kautz, Elizabeth J. [University of Florida]

ATom (Acoustic Tomography Processing Suite) [SWR-24-120]

Acoustic tomography seeks the best-fit fluctuating velocity and temperature fields that explain a collection of signal travel times in a region of interest. This codebase defines an end-to-end framework for executing turbulent field retrievals from acoustic signals, acoustic signal design and processing tools for the physical array, and analysis tool that leverage virtual acoustic tomography arrays based on large-eddy simulations of the atmospheric boundary layer.

Hamilton, Nicholas

Evaluating multi-slice ptychography tomography for X-ray imaging

X-ray ptychography typically relies on single-slice reconstruction approaches that assume minimal beam propagation through the specimen. However, this approximation breaks down for thick samples or when using high numerical aperture optics, leading to reconstruction artifacts due to multiple scattering. Multi-slice ptychographic tomography (MSPT) addresses this limitation by explicitly modeling beam propagation through the specimen while reducing angular sampling requirements for tomography, but its performance depends critically on reconstruction parameters and experimental conditions. Here, we systematically evaluate MSPT using numerical simulations and experimental X-ray datasets to understand how factors such as object thickness, optical parameters, and initialization strategies affect reconstruction accuracy. We demonstrate that informed object initialization significantly improves depth resolution and enables accurate projection extension, reducing the angular sampling requirements for tomographic reconstruction. Experimental demonstration confirms that MSPT produces reconstructions with reduced artifacts, establishing it as a robust approach for nanoscale imaging at modern synchrotron facilities.

Luktuke, Amey [Argonne National Laboratory (ANL),

Deployed quantum link characterization via Bayesian ancilla-assisted process tomography

The development of large-scale quantum networks requires reliable quantum channels, the quality of which can be quantified by the framework of quantum process tomography. Here, in this work, we leverage ancilla-assisted process tomography (AAPT) and Bayesian inference to probe a 1.6 km deployed fiber-optic link. We send one of the two polarization-entangled photons at Alice in one building to Bob in another, exploiting the local qubit as an ancilla system to characterize the corresponding quantum channel. Monitoring over a 24 h period returns a steady process fidelity of 97.6(1)%, while controllable spectral filtering with passbands from 0.025 to 4.38 THz finds fidelities that first increase, and then level off with bandwidth, suggesting both stable operation with time and minimal polarization mode dispersion. To our knowledge, these results represent the first AAPT of a deployed quantum link, revealing a valuable tool for in situ analysis of entanglement-based quantum networks.

Rahman, Arefur [Arizona State Univ., Tempe, AZ (Un

Laser-driven high-resolution MeV x-ray tomography

The need for high-resolution MeV x-ray tomography to observe the three-dimensional structure of dense, large-sized objects is rapidly increasing for the non-destructive evaluation of critical additively manufactured parts, national security, and other applications. We report a demonstration of high-resolution MeV computed tomography of a dense, large object with a laser-driven x-ray source. A record detector-limited MeV radiograph resolution of < 200 µm as determined with the Bennett approximation of the point spread function was achieved by irradiating millimeter-thick tungsten targets with 300 TW femtosecond laser pulses at a 0.5 Hz repetition rate. A tungsten alloy step wedge spectrometer indicates that the peak of the x-ray emission is between 1 and 2 MeV, with an endpoint energy of 19 MeV. To illustrate the radiographic imaging capability of the system, a tomographic reconstruction of a nickel superalloy turbine blade ( maximum $ρr$ = 139 g/cm 2 ) with sub-millimeter resolution was performed using 2160 individual radiographs. The small x-ray source size opens the prospect of extremely high-resolution tomographs of large, dense objects. This laser-driven approach has major advantages for non-destructive evaluation.

47 OTHER INSTRUMENTATION

Improved Regional Moment Tensor Inversion for Moderately Large Earthquakes in the Western United States Using a 3D Earth Model Based on Full Waveform Tomography

The nature of seismic sources for moderately large (moment magnitude, M w 5.0–6.5) events are commonly characterized by their moment tensor (MT) solutions and obtained by inversion of regional distance (200–1600 km) long‐period (20–50 s) waveforms. Regional MT estimates are often calculated from average plane‐layered, one‐dimensional (1D) velocity models. However, 1D model calculations can produce misfits in the arrival times and waveform shapes that introduce errors, particularly at longer distances or for shorter periods, which are necessary for analyzing lower magnitude events. Approximate Earth models (e.g., 1D) representing broad areas may be inadequate, particularly in the crust and uppermost mantle of tectonically complex regions. In this study, we show how a three‐dimensional (3D) Earth model obtained from full waveform inversion tomography can improve waveform fits and decrease phase errors. We developed a platform and workflow to perform routine 3D MT inversions and inverted MTs for 25 earthquakes in the western United States and seven nuclear explosions using an average 1D and a recent 3D Earth model, WUS256 (Rodgers et al., 2022). Using the 3D model improves waveform fits (variance reduction and phase time shifts) compared with the 1D model, and the 3D MT solutions are stable across large distances. This study shows that 3D models obtained from full waveform tomography can improve MTs and source characterization especially at far regional distances (>800 km).

Geosciences

Technical Report on Adjoint Waveform Tomography of East Asia for Improved Waveform Prediction

We present a preliminary version of the East Asia Tomography (EAT) model, an adjoint waveform tomography model of East and Southeast Asia. We used SPiRaL (Simmons et al., 2021) as our starting model and source parameters for 250 earthquakes from the Global Centroid Moment Tensor catalogue (Ekström et al., 2012). Over 198 iterations, we have iterated the EAT model down to a minimum period of 35 seconds. We plan on continuing our iteration technique down to 30 seconds period before updating our misfit function to use a normalized cross correlation-based misfit functions (e.g., Tao et al., 2018) to better constrain Earth structure. We hope to iterate the current extent of the model to 25 seconds minimum period before iterating to shorter periods for a smaller subregion of the full model.

58 GEOSCIENCES

Longitudinal Phase Space Tomography for the Booster Synchrotron

Efforts in the study of the longitudinal behavior of charged particles in the Fermilab Booster can be catalyzed with an image of the two-dimensional phase space distribution. In the past, tomography has been extensively employed in the reconstruction of the phase space in accelerators such as the Recycler at Fermilab and the Proton Synchrotron Booster at CERN. However, such a capability had yet to realize for the Fermilab Booster synchrotron. In this work, the first successful tomographic phase space reconstruction of a low-energy Booster bunch is presented along with validation metrics. A numerical turn-by-turn model of the longitudinal particle dynamics in the Booster has been implemented, which utilizes a fast, map-based particle transport algorithm. Using a sinogram generated from the Wall Current Monitor, the iterative reconstruction algorithm recovers a discretized image of the original phase space distribution at variable resolution. The reconstruction result shows low root-mean-square error and a rapid convergence toward the solution, providing strong evidence of accuracy. Future and ongoing work includes modeling high-energy bunches above transition and using tomography to infer certain machine parameters such as synchronous phase, peak gap voltage, and synchronous energy in addition to the phase space distribution.

Ebeid, Safi [Unlisted]

Longitudinal Phase Space Tomography for the Booster Synchrotron (Abstract Only)

Efforts in the study of the longitudinal behavior of charged particles in the Fermilab Booster can be catalyzed with an image of the two-dimensional phase space distribution. In the past, tomography has been extensively employed in the reconstruction of the phase space in accelerators such as the Recycler at Fermilab and the Proton Synchrotron Booster at CERN. However, such a capability had yet to realize for the Fermilab Booster synchrotron. In this work, the first successful tomographic phase space reconstruction of a low-energy Booster bunch is presented along with validation metrics. A numerical turn-by-turn model of the longitudinal particle dynamics in the Booster has been implemented, which utilizes a fast, map-based particle transport algorithm. Using a sinogram generated from the Wall Current Monitor, the iterative reconstruction algorithm recovers a discretized image of the original phase space distribution at variable resolution. The reconstruction result shows low root-mean-square error and a rapid convergence toward the solution, providing strong evidence of accuracy. Future and ongoing work includes modeling high-energy bunches above transition and using tomography to infer certain machine parameters such as synchronous phase, peak gap voltage, and synchronous energy in addition to the phase space distribution.

Ebeid, Safi [Unlisted, US]