Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “time multiplexing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Zero-added-loss entanglement multiplexing using time-bin spectral shearing

High-quality quantum communications that enable important capabilities, such as distributed quantum computing and sensing, will require quantum repeaters for providing high-quality entanglement. To realize high-rate heralded entanglement for quantum repeaters, Chen et al . [Phys. Rev. Appl. 19 , 054029 (2023)] proposed a scheme for heralded-multiplexed generation of quasideterministic entangled photon pairs, called zero-added-loss multiplexing (ZALM). Here, we propose a design of the ZALM source using time-bin entanglement and spectral shearing. Additionally, we provide an analysis of experimentally relevant spectral-shearing parameters to optimize the spectral multiplexing. Moreover, we experimentally verify the compatibility of time-bin pulses and spectral shearing, as supported by observation of no appreciable phase shift when the same shearing is applied to both time bins. These results expand the benefits of applying a ZALM source to time-bin entanglement use cases. Moreover, more fully demonstrating time-bin and spectral shearing compatibility clears a path toward a broader use of spectral shearing that provides a deterministic frequency shift of high utility.

entanglement production↗

Evaluation of a laboratory-developed multiplex real-time PCR assay for diagnosis of syphilis, herpes and chancroid genital ulcers in four public health laboratories in the USA

Objective To evaluate the field performance of a multiplex PCR (M-PCR) assay for detection of herpes simplex virus (HSV)-1 and HSV-2, Treponema pallidum ( T. pallidum ) and Haemophilus ducreyi ( H. ducreyi ) in genital ulcer disease (GUD) specimens. Methods GUD M-PCR was performed on 186 remnant specimens, previously collected for HSV testing, by four public health laboratories (PHLs) and the Laboratory Reference and Research Branch (LRRB) at the Centers for Disease Control and Prevention. The results from the PHLs were compared with those of LRRB, which served as the reference testing method, and percentage agreement was calculated. Results HSV was detected in 31 of 52 (59.6%), 20 of 40 (50%), 43 of 44 (97.7%) and 19 of 50 (38.0%) specimens from PHL1, PHL2, PHL3 and PHL4, respectively. There were seven discrepant results for HSV, and the overall percent agreement between the PHLs and the LRRB was 94%–100%, with a kappa value of 0.922, which demonstrates high agreement. T. pallidum was identified in 7 of 51 (13.7%) specimens from PHL1 with 94.1% agreement and in 2 of 40 (5.0%) specimens from PHL2 with 100% agreement. The LRRB identified three additional T. pallidum -positive specimens from PHL1. The kappa value (0.849) for T. pallidum testing suggests good agreement. Consistent with the LRRB results, no T. pallidum was detected in specimens from PHL3 and PHL4, and H. ducreyi was not detected at any of the study sites. Conclusions The GUD M-PCR assay performed well in four independent PHLs and 12 suspected syphilis cases were identified in this study. The M-PCR assay could provide improved diagnostic options for GUD infections in state and local PHLs.

Infectious Diseases↗

Conceptual design of the modular detector and readout system for the CMB-S4 survey experiment

We present the conceptual design of the modular detector and readout system for the Cosmic Microwave Background – Stage four (CMB-S4) ground-based survey experiment. CMB-S4 will map the cosmic microwave background (CMB) and the millimeter-wave sky to unprecedented sensitivity, using 500,000 superconducting detectors observing from Chile and Antarctica to map over 60% of the sky. The fundamental building block of the detector and readout system is a detector module package operated at 100 mK, which is connected to a readout and amplification chain that carries signals out to room temperature. It uses arrays of feedhorn-coupled orthomode transducers (OMT) that collect optical power from the sky onto dc-voltage-biased transition-edge sensor (TES) bolometers. The resulting current signal in the TESs is then amplified by a two-stage cryogenic Superconducting Quantum Interference Device (SQUID) system with a time-division multiplexer to reduce wire count, and matching room-temperature electronics to condition and transmit signals to the data acquisition system. Sensitivity and systematics requirements are being developed for the detector and readout system over wide range of observing bands (20 to 300 GHz) and optical powers to accomplish CMB-S4’s science goals. While the design incorporates the successes of previous generations of CMB instruments, CMB-S4 requires an order of magnitude more detectors than any prior experiment. This requires fabrication of complex superconducting circuits on over 10 m2 of silicon, as well as significant amounts of precision wiring, assembly and cryogenic testing

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

End-to-End Modeling of the TDM Readout System for CMB-S4

The CMB-S4 experiment is developing next-generation ground-based microwave telescopes to observe the cosmic microwave background with unprecedented sensitivity. This will require an order of magnitude increase in the 100-mK detector count, which, in turn, increases the demands on the readout system. The CMB-S4 readout will use time-division multiplexing (TDM), taking advantage of faster switches and amplifiers in order to achieve an increased multiplexing factor. To facilitate the design of the new readout system, we have developed a model that predicts the bandwidth and noise performance of this circuitry and its interconnections. This is then used to set requirements on individual components in order to meet the performance necessary for the full system. Here, we present an overview of this model and compare the model results to the performance of both legacy and prototype readout hardware.

47 OTHER INSTRUMENTATION↗

Improved Frequency-Domain Steady-State Modeling of the Dual-Active-Bridge Converter Considering Finite ZVS Transition Time Effects

This article presents an improved analytical modeling (IAM) approach for the dual-active-bridge (DAB) converter in the frequency-domain. Specifically, finite transition times are incorporated into the improved modeling that are significant in DAB converters operated at high frequency. The IAM approach is first motivated by comparing traditional frequency-domain modeling against realistic simulation results in LTspice. Next, the IAM approach is mathematically developed in an iterative fashion, where the conventional frequency-domain approach is used as the initialization of the operational behavior of the converter. Subsequent iterations of the IAM algorithm incorporate finite rise- and falltimes of device output capacitances based on detailed switching behavior analyses, which may considerably perturb the desired modulation parameters (i.e., phase shift and zero states). While the initially proposed IAM approach demonstrates advantages over ideal modeling, it is still shown to exhibit errors when applied to device transitions with significant nonlinearity in parasitic output capacitance. To account for this, a three-slope approximation to the switching transition is then motivated and developed, which enables significantly improved steady-state prediction accuracy. Simulation and experimental results confirm unacceptable inaccuracies associated with the conventional frequency-domain modeling across a wide range of operating conditions, alongside enhanced accuracy provided by the proposed modeling approach.

14 SOLAR ENERGY↗

BICEP Array: 150 GHz Detector Module Development

The Background Imaging of Cosmic Extragalactic Polarization (BICEP)/Keck (BK) collaboration is currently leading the quest for the highest-sensitivity measurements of the polarized cosmic microwave background (CMB) anisotropies on a degree scale with a series of cryogenic telescopes, of which BICEP Array (BA) is the latest Stage-3 upgrade with a total of ~ 32,000 detectors. The instrument comprises 4 receivers spanning 30–270 GHz, with the low-frequency 30/40 GHz deployed to the South Pole Station in late 2019. The full complement of receivers is forecast to set the most stringent constraints on the tensor-to-scalar ratio r. Building on these advances, the overarching small-aperture telescope concept is already being used as the reference for further Stage-4 experiment design. This paper describes the development of the BICEP Array 150 GHz detector module and its fabrication requirements, with highlights on the high-density time division multiplexing (TDM) design of the cryogenic circuit boards. The low-impedance wiring required between the detectors and the frst stage of superconducting quantum interference device amplifers is crucial to maintaining a stable bias current on the detectors. Here, a novel multilayer FR4 Printed Circuit Board with superconducting traces, capable of reading out up to 648 detectors, is detailed along with its validation tests. An ultra-high-density TDM detector module concept we developed for a CMB-S4-like experiment that allows up to 1920 detectors to be read out is also presented. TDM has been chosen as the detector readout technology for the Cosmic Microwave Background Stage-4 (CMB-S4) experiment based on its proven low-noise performance, predictable costs, and overall maturity of the architecture. The heritage for TDM is rooted in mm- and sub-mm-wave experiments dating back 20 years and has since evolved to support a multiplexing factor of 64x in Stage-3 experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

Deep Spectroscopy with DESI for Photometric Redshift Training and Calibration

Deep spectroscopic samples can improve photometric redshift (photo-z) estimates and reduce uncertainties on redshift distributions. Such improvements can increase the cosmological constraining power of large imaging-based experiments such as the Vera C. Rubin Observatory’s Legacy Survey of Space and Time (LSST) and mitigate what may be a limiting systematic effect. We present results from the “DESI-Deep pilot” program, which was designed to assess the capability of the Dark Energy Spectroscopic Instrument (DESI) on the 4m Mayall telescope to measure redshifts of galaxies as faint as expected lensing samples for early LSST data (m i ≤ 24.5). We find that DESI is remarkably efficient at this task, with redshift success rates comparable to the results of observations from 10 m class telescopes with only ∼2 × longer integration time (rather than ∼8 × longer as would be expected from aperture-area scaling), while simultaneously achieving ∼30 times larger multiplexing. We also find that the signal-to-noise ratio of the spectra scales as expected for background-limited observations even for the longest exposure times (∼7 hr) and faintest targets in the program. These results demonstrate that DESI could provide the definitive redshift sample for the early years of LSST with a modest investment of observing time. Based upon the results of this program, we provide updated predictions for the time required to collect benchmark samples for photo-z training and calibration using a variety of spectroscopic facilities. Finally, we describe a potential “DESI-Deep” survey designed to train and calibrate photo-z’s for imaging experiments, and provide forecasts of its impact on cosmological inference.

Dey, Biprateep [University of Toronto; University ↗

Multiplex RNA-guided genome engineering

Methods of multiplex genome engineering in cells using Cas9 is provided which includes a cycle of steps of introducing into the cell a first foreign nucleic acid encoding one or more RNAs complementary to the target DNA and which guide the enzyme to the target DNA, wherein the one or more RNAs and the enzyme are members of a co-localization complex for the target DNA, and introducing into the cell a second foreign nucleic acid encoding one or more donor nucleic acid sequences, and wherein the cycle is repeated a desired number of times to multiplex DNA engineering in cells.

Church, George M.↗

High-rate multiplexed entanglement source based on time-bin qubits for advanced quantum networks

Entanglement distribution based on time-bin qubits is an attractive option for emerging quantum networks. We demonstrate a 4.09-GHz repetition rate source of photon pairs entangled across early and late time bins separated by 80 ps. Simultaneous high rates and high visibilities are achieved through frequency multiplexing the spontaneous parametric down conversion output into eight time-bin entangled channel pairs. We demonstrate entanglement visibilities as high as 99.4%, total entanglement rates up to 3.55×10 6 coincidences/s, and predict a straightforward path towards achieving up to an order of magnitude improvement in rates without compromising visibility. Finally, we resolve the density matrices of the entangled states for each multiplexed channel and express distillable entanglement rates in ebit/s, thereby quantifying the trade-off between visibility and coincidence rates that contributes to useful entanglement distribution. This source is a fundamental building block for high-rate entanglement-based quantum key distribution systems or advanced quantum networks.

Mueller, Andrew (ORCID:0000000265989732)↗

Excitation spectral microscopy for highly multiplexed fluorescence imaging and quantitative biosensing

The multiplexing capability of fluorescence microscopy is severely limited by the broad fluorescence spectral width. Spectral imaging offers potential solutions, yet typical approaches to disperse the local emission spectra notably impede the attainable throughput. Here we show that using a single, fixed fluorescence emission detection band, through frame-synchronized fast scanning of the excitation wavelength from a white lamp via an acousto-optic tunable filter, up to six subcellular targets, labeled by common fluorophores of substantial spectral overlap, can be simultaneously imaged in live cells with low (~1%) crosstalks and high temporal resolutions (down to ~10 ms). The demonstrated capability to quantify the abundances of different fluorophores in the same sample through unmixing the excitation spectra next enables us to devise novel, quantitative imaging schemes for both bi-state and Förster resonance energy transfer fluorescent biosensors in live cells. We thus achieve high sensitivities and spatiotemporal resolutions in quantifying the mitochondrial matrix pH and intracellular macromolecular crowding, and further demonstrate, for the first time, the multiplexing of absolute pH imaging with three additional target organelles/proteins to elucidate the complex, Parkin-mediated mitophagy pathway. Together, excitation spectral microscopy provides exceptional opportunities for highly multiplexed fluorescence imaging. The prospect of acquiring fast spectral images without the need for fluorescence dispersion or care for the spectral response of the detector offers tremendous potential.

59 BASIC BIOLOGICAL SCIENCES↗

The X-ray Integral Field Unit at the end of the Athena reformulation phase

The Athena mission entered a redefinition phase in July 2022, driven by the imperative to reduce the mission cost at completion for the European Space Agency below an acceptable target, while maintaining the flagship nature of its science return. This notably called for a complete redesign of the X-ray Integral Field Unit (X-IFU) cryogenic architecture towards a simpler active cooling chain. Passive cooling via successive radiative panels at spacecraft level is now used to provide a 50 K thermal environment to an X-IFU owned cryostat. 4.5 K cooling is achieved via a single remote active cryocooler unit, while a multi-stage Adiabatic Demagnetization Refrigerator ensures heat lift down to the 50 mK required by the detectors. Amidst these changes, the core concept of the readout chain remains robust, employing Transition Edge Sensor microcalorimeters and a SQUID-based Time-Division Multiplexing scheme. Noteworthy is the introduction of a slower pixel. This enables an increase in the multiplexing factor (from 34 to 48) without compromising the instrument energy resolution, hence keeping significant system margins to the new 4 eV resolution requirement. This allows reducing the number of channels by more than a factor two, and thus the resource demands on the system, while keeping a 4’ field of view (compared to 5’ before). Here, in this article, we will give an overview of this new architecture, before detailing its anticipated performances. Finally, we will present the new X-IFU schedule, with its short term focus on demonstration activities towards a mission adoption in early 2027.

Peille, Philippe [Centre National d’Etudes Spatial↗

Radical–Radical Reactions in Molecular Weight Growth: The Phenyl + Propargyl Reaction

The mechanism for hydrocarbon ring growth in sooting environments is still the subject of considerable debate. The reaction of phenyl radical (C 6 H 5 ) with propargyl radical (H 2 CCCH) provides an important prototype for radical–radical ring-growth pathways. We studied this reaction experimentally over the temperature range of 300–1000 K and pressure range of 4–10 Torr using time-resolved multiplexed photoionization mass spectrometry. We detect both the C 9 H 8 and C 9 H 7 + H product channels and report experimental isomer-resolved product branching fractions for the C 9 H 8 product. We compare these experiments to theoretical kinetics predictions from a recently published study augmented by new calculations. Here, these ab initio transition state theory-based master equation calculations employ high-quality potential energy surfaces, conventional transition state theory for the tight transition states, and direct CASPT2-based variable reaction coordinate transition state theory (VRC-TST) for the barrierless channels. At 300 K only the direct adducts from radical–radical addition are observed, with good agreement between experimental and theoretical branching fractions, supporting the VRC-TST calculations of the barrierless entrance channel. As the temperature is increased to 1000 K we observe two additional isomers, including indene, a two-ring polycyclic aromatic hydrocarbon, and a small amount of bimolecular products C 9 H 7 + H. Our calculated branching fractions for the phenyl + propargyl reaction predict significantly less indene than observed experimentally. We present further calculations and experimental evidence that the most likely cause of this discrepancy is the contribution of H atom reactions, both H + indenyl (C 9 H 7 ) recombination to indene and H-assisted isomerization that converts less stable C 9 H 8 isomers into indene. Especially at low pressures typical of laboratory investigations, H-atom-assisted isomerization needs to be considered. Regardless, the experimental observation of indene demonstrates that the title reaction leads, either directly or indirectly, to the formation of the second ring in polycyclic aromatic hydrocarbons.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Conformer-Dependent Chemistry: Experimental Product Branching of the Vinyl Alcohol + OH + O 2 Reaction

The concentration of formic acid in Earth's tropo-sphere is underestimated by detailed chemical models compared to field observations. Phototautomerization of acetaldehyde to its less stable tautomer vinyl alcohol, followed by the OH-initiated oxidation of vinyl alcohol, has been proposed as a missing source of formic acid that improves the agreement between models and field measurements. Theoretical investigations of the OH + vinyl alcohol reaction in excess O 2 conclude that OH addition to the alpha carbon of vinyl alcohol produces formaldehyde + formic acid + OH, whereas OH addition to the β site leads to glycoaldehyde + HO 2 . Furthermore, these studies predict that the conformeric structure of vinyl alcohol controls the reaction pathway, with the anti-conformer of vinyl alcohol promoting α OH addition, whereas the syn-conformer promotes β addition. However, the two theoretical studies reach different conclusions regarding which set of products dominate. We studied this reaction using time-resolved multiplexed photoionization mass spectrometry to quantify the product branching fractions. Our results, supported by a detailed kinetic model, conclude that the glycoaldehyde product channel (arising mostly from syn-vinyl alcohol) dominates over formic acid production with a 3.6:1.0 branching ratio. Additionally, this result supports the conclusion of Lei et al. that conformer-dependent hydrogen bonding at the transition state for OH-addition controls the reaction outcome. As a result, tropospheric oxidation of vinyl alcohol creates less formic acid than recently thought, increasing again the discrepancy between models and field observations of Earth's formic acid budget.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design and performance of an in-vacuum, magnetic field mapping system for the Muon g-2 experiment

The Muon g - 2 experiment at Fermilab (E989) aims to measure the anomalous magnetic moment, a μ , of the muon with a precision of 140 parts-per-billion. This requires a precise measurement of both the anomalous spin precession frequency, ω α , of muons stored in a magnetic field of 1.45 T, and a precise measurement of that magnetic field in terms of the shielded proton Larmor frequency, ω' ρ . The measurement of ω' ρ with a total systematic uncertainty of 70 parts-perbillion involves a combination of various nuclear magnetic resonance (NMR) probes. There are 378 probes mounted in fixed locations that constantly monitor field drifts. A water-based, cylindrical calibration probe provides the calibration in terms of the shielded proton Larmor frequency. A crucial element for the multi-step measurement of ω' ρ is the regular mapping of the magnetic field over the muon storage region. The former experiment at Brookhaven National Laboratory (BNL) employed an in-vacuum field mapping system equipped with 17 NMR probes, which was developed by the University of Heidelberg. We have refurbished and upgraded this system with new probes and electronics. The upgrades include the addition of 16-bit, 1 MSPS digitization of the NMR signals, which replaced the hardware-implemented zero-crossing counting of the system at Brookhaven. The digitized signals offer new capabilities in the NMR frequency analysis and its related systematic uncertainties. To sustain the higher data rates, a new communication scheme with time-division multiplexing was implemented to separate the important NMR reference clock from the data communication in order to reach the specifications for the accuracy and stability of the reference clock. A new barcode reader provides more precise azimuthal position determination during the measurement and calibration. While the mechanical systems that move the field mapper inside the storage ring have been mostly refurbished from BNL, the motion control system was completely replaced with a custom-built electronics centered around a commercial Galil motion controller. Both the field mapping NMR system and its motion control were successfully commissioned at Fermilab and have been in reliable operation during the first three data taking periods of the experiment at Fermilab. Finally, this article will provide the details of the upgrades of the field mapper and its performance.

47 OTHER INSTRUMENTATION↗

Line emission mapper microcalorimeter spectrometer

The line emission mapper (LEM) is a probe-class mission concept that is designed to detect x-ray emission lines from hot ionized gas (T > 10 6 K) that will enable us to test galaxy evolution theories. It will permit us to study the effects of stellar and black-hole feedback and flows of baryonic matter into and out of galaxies. The key to being able to study the hot gases that are otherwise invisible to current imaging x-ray spectrometers is that the energy resolution is sufficient to use cosmological redshift to separate extragalactic source lines from foreground Milky Way emission. LEM incorporates a large-format microcalorimeter array instrument called the LEM microcalorimeter spectrometer (LMS) with a light-weight x-ray optic with 10” half power diameter angular resolution. The LMS microcalorimeter array has pixels with 15" pixel pitch over a 33' field of view (FOV) optimized for the 0.3 to 2 keV energy band. The central 7' region of the array has an energy resolution of 1.3 eV at 1 keV and the rest of the FOV has 2.5 eV energy resolution at 1 keV. The array will be read out with state-of-the-art time-division multiplexing. We present an overview of the LMS instrument, including details of the entire detection chain, the focal plane assembly, as well as the cooling system and overall mechanical and thermal design. For each of the key technologies, we discuss the current technology readiness level and the plan to advance them to be ready for flight. We also describe the current system design and our estimate for the mass, power, and data rate of the instrument. The design details presented concentrate primarily on the unique aspects of the LMS design compared with prior missions and confirm that the type of microcalorimeter instrument needed for LEM is not only feasible but also technically mature.

47 OTHER INSTRUMENTATION↗

Singleplex, multiplex and pooled sample real-time RT-PCR assays for detection of SARS-CoV-2 in an occupational medicine setting

Abstract For workplaces which cannot operate as telework or remotely, there is a critical need for routine occupational SARS-CoV-2 diagnostic testing. Although diagnostic tests including the CDC 2019-Novel Coronavirus (2019-nCoV) Real-Time RT-PCR Diagnostic Panel (CDC Diagnostic Panel) (EUA200001) were made available early in the pandemic, resource scarcity and high demand for reagents and equipment necessitated priority of symptomatic patients. There is a clearly defined need for flexible testing methodologies and strategies with rapid turnaround of results for (1) symptomatic, (2) asymptomatic with high-risk exposures and (3) asymptomatic populations without preexisting conditions for routine screening to address the needs of an on-site work force. We developed a distinct SARS-CoV-2 diagnostic assay based on the original CDC Diagnostic Panel (EUA200001), yet, with minimum overlap for currently employed reagents to eliminate direct competition for limited resources. As the pandemic progressed with testing loads increasing, we modified the assay to include 5-sample pooling and amplicon target multiplexing. Analytical sensitivity of the pooled and multiplexed assays was rigorously tested with contrived positive samples in realistic patient backgrounds. Assay performance was determined with clinical samples previously assessed with an FDA authorized assay. Throughout the pandemic we successfully tested symptomatic, known contact and travelers within our occupational population with a ~ 24–48-h turnaround time to limit the spread of COVID-19 in the workplace. Our singleplex assay had a detection limit of 31.25 copies per reaction. The three-color multiplexed assay maintained similar sensitivity to the singleplex assay, while tripling the throughput. The pooling assay further increased the throughput to five-fold the singleplex assay, albeit with a subtle loss of sensitivity. We subsequently developed a hybrid ‘multiplex-pooled’ strategy to testing to address the need for both rapid analysis of samples from personnel at high risk of COVID infection and routine screening. Herein, our SARS-CoV-2 assays specifically address the needs of occupational healthcare for both rapid analysis of personnel at high-risk of infection and routine screening that is essential for controlling COVID-19 disease transmission. In addition to SARS-CoV-2 and COVID-19, this work demonstrates successful flexible assays developments and deployments with implications for emerging highly transmissible diseases and future pandemics.

60 APPLIED LIFE SCIENCES↗

Quantum optical memory for entanglement distribution

Optical photons are powerful carriers of quantum information, which can be delivered in free space by satellites or in fibers on the ground over long distances. Entanglement of quantum states over long distances can empower quantum computing, quantum communications, and quantum sensing. Quantum optical memories are devices designed to store quantum information in the form of stationary excitations, such as atomic coherence, and are capable of coherently mapping these excitations to flying qubits. Quantum memories can effectively store and manipulate quantum states, making them indispensable elements in future long-distance quantum networks. Over the past two decades, quantum optical memories with high fidelities, high efficiencies, long storage times, and promising multiplexing capabilities have been developed, especially at the single-photon level. In this review, we introduce the working principles of commonly used quantum memory protocols and summarize the recent advances in quantum memory demonstrations. We also offer a vision for future quantum optical memory devices that may enable entanglement distribution over long distances.

Lei, Yisheng↗

Generalized large optics fabrication multiplexing

High precision astronomical optics are manufactured through deterministic computer controlled optical surfacing processes, such as subaperture small tool polishing, magnetorheological finishing, bonnet tool polishing, and ion beam figuring. Due to the small tool size and the corresponding tool influence function, large optics fabrication is a highly time-consuming process. The framework of multiplexed figuring runs for the simultaneous use of two or more tools is presented. This multiplexing process increases the manufacturing efficiency and reduces the overall cost using parallelized subaperture tools.

36 MATERIALS SCIENCE↗