Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “tilt”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Transient cardio-respiratory responses to visually induced tilt illusions

Although the orthostatic cardio-respiratory response is primarily mediated by the baroreflex, studies have shown that vestibular cues also contribute in both humans and animals. We have demonstrated a visually mediated response to illusory tilt in some human subjects. Blood pressure, heart and respiration rate, and lung volume were monitored in 16 supine human subjects during two types of visual stimulation, and compared with responses to real passive whole body tilt from supine to head 80 degrees upright. Visual tilt stimuli consisted of either a static scene from an overhead mirror or constant velocity scene motion along different body axes generated by an ultra-wide dome projection system. Visual vertical cues were initially aligned with the longitudinal body axis. Subjective tilt and self-motion were reported verbally. Although significant changes in cardio-respiratory parameters to illusory tilts could not be demonstrated for the entire group, several subjects showed significant transient decreases in mean blood pressure resembling their initial response to passive head-up tilt. Changes in pulse pressure and a slight elevation in heart rate were noted. These transient responses are consistent with the hypothesis that visual-vestibular input contributes to the initial cardiovascular adjustment to a change in posture in humans. On average the static scene elicited perceived tilt without rotation. Dome scene pitch and yaw elicited perceived tilt and rotation, and dome roll motion elicited perceived rotation without tilt. A significant correlation between the magnitude of physiological and subjective reports could not be demonstrated.

NASA Center JSC↗

Tilt and Translation Motion Perception during Off Vertical Axis Rotation

The effect of stimulus frequency on tilt and translation motion perception was studied during constant velocity off-vertical axis rotation (OVAR), and compared to the effect of stimulus frequency on eye movements. Fourteen healthy subjects were rotated in darkness about their longitudinal axis 10deg and 20deg off-vertical at 0.125 Hz, and 20deg offvertical at 0.5 Hz. Oculomotor responses were recorded using videography, and perceived motion was evaluated using verbal reports and a joystick with four degrees of freedom (pitch and roll tilt, mediallateral and anteriorposterior translation). During the lower frequency OVAR, subjects reported the perception of progressing along the edge of a cone. During higher frequency OVAR, subjects reported the perception of progressing along the edge of an upright cylinder. The modulation of both tilt recorded from the joystick and ocular torsion significantly increased as the tilt angle increased from 10deg to 20deg at 0.125 Hz, and then decreased at 0.5 Hz. Both tilt perception and torsion slightly lagged head orientation at 0.125 Hz. The phase lag of torsion increased at 0.5 Hz, while the phase of tilt perception did not change as a function of frequency. The amplitude of both translation perception recorded from the joystick and horizontal eye movements was negligible at 0.125 Hz and increased as a function of stimulus frequency. While the phase lead of horizontal eye movements decreased at 0.5 Hz, the phase of translation perception did not vary with stimulus frequency and was similar to the phase of tilt perception during all conditions. During dynamic linear acceleration in the absence of other sensory input (canal, vision) a change in stimulus frequency alone elicits similar changes in the amplitude of both self motion perception and eye movements. However, in contrast to the eye movements, the phase of both perceived tilt and translation motion is not altered by stimulus frequency. We conclude that the neural processing to distinguish tilt and translation linear acceleration stimuli differs between eye movements and motion perception.

Wood, Scott J.↗

Effects of Frequency and Motion Paradigm on Perception of Tilt and Translation During Periodic Linear Acceleration

Previous studies have demonstrated an effect of frequency on the gain of tilt and translation perception. Results from different motion paradigms are often combined to extend the stimulus frequency range. For example, Off-Vertical Axis Rotation (OVAR) and Variable Radius Centrifugation (VRC) are useful to test low frequencies of linear acceleration at amplitudes that would require impractical sled lengths. The purpose of this study was to compare roll-tilt and lateral translation motion perception in 12 healthy subjects across four paradigms: OVAR, VRC, sled translation and rotation about an earth-horizontal axis. Subjects were oscillated in darkness at six frequencies from 0.01875 to 0.6 Hz (peak acceleration equivalent to 10 deg, less for sled motion below 0.15 Hz). Subjects verbally described the amplitude of perceived tilt and translation, and used a joystick to indicate the direction of motion. Consistent with previous reports, tilt perception gain decreased as a function of stimulus frequency in the motion paradigms without concordant canal tilt cues (OVAR, VRC and Sled). Translation perception gain was negligible at low stimulus frequencies and increased at higher frequencies. There were no significant differences between the phase of tilt and translation, nor did the phase significantly vary across stimulus frequency. There were differences in perception gain across the different paradigms. Paradigms that included actual tilt stimuli had the larger tilt gains, and paradigms that included actual translation stimuli had larger translation gains. In addition, the frequency at which there was a crossover of tilt and translation gains appeared to vary across motion paradigm between 0.15 and 0.3 Hz. Since the linear acceleration in the head lateral plane was equivalent across paradigms, differences in gain may be attributable to the presence of linear accelerations in orthogonal directions and/or cognitive aspects based on the expected motion paths.

Beaton, K. H.↗

Influence of Vibrotactile Feedback on Controlling Tilt Motion After Spaceflight

We hypothesize that adaptive changes in how inertial cues from the vestibular system are integrated with other sensory information leads to perceptual disturbances and impaired manual control following transitions between gravity environments. The primary goals of this ongoing post-flight investigation are to quantify decrements in manual control of tilt motion following short-duration spaceflight and to evaluate vibrotactile feedback of tilt as a sensorimotor countermeasure. METHODS. Data is currently being collected on 9 astronaut subjects during 3 preflight sessions and during the first 8 days after Shuttle landings. Variable radius centrifugation (216 deg/s, <20 cm radius) in a darkened room is utilized to elicit otolith reflexes in the lateral plane without concordant canal or visual cues. A Tilt-Translation Sled (TTS) is capable of synchronizing pitch tilt with fore-aft translation to align the resultant gravitoinertial vector with the longitudinal body axis, thereby eliciting canal reflexes without concordant otolith or visual cues. A simple 4 tactor system was implemented to provide feedback when tilt position exceeded predetermined levels in either device. Closed-loop nulling tasks are performed during random tilt steps or sum-of-sines (TTS only) with and without vibrotactile feedback of chair position. RESULTS. On landing day the manual control performance without vibrotactile feedback was reduced by >30% based on the gain or the amount of tilt disturbance successfully nulled. Manual control performance tended to return to baseline levels within 1-2 days following landing. Root-mean-square position error and tilt velocity were significantly reduced with vibrotactile feedback. CONCLUSIONS. These preliminary results are consistent with our hypothesis that adaptive changes in vestibular processing corresponds to reduced manual control performance following G-transitions. A simple vibrotactile prosthesis improves the ability to null out tilt motion within a limited range of motion disturbances.

Wood, S. J.↗

Effects of Vestibular Loss on Orthostatic Responses to Tilts in the Pitch Plane

The purpose of this study was to determine the extent to which vestibular loss might impair orthostatic responses to passive tilts in the pitch plane in human subjects. Data were obtained from six subjects having chronic bilateral vestibular loss and six healthy individuals matched for age, gender, and body mass index. Vestibular loss was assessed with a comprehensive battery including dynamic posturography, vestibulo-ocular and optokinetic reflexes, vestibular evoked myogenic potentials, and ocular counterrolling. Head up tilt tests were conducted using a motorized two-axis table that allowed subjects to be tilted in the pitch plane from either a supine or prone body orientation at a slow rate (8 deg/s). The sessions consisted of three tilts, each consisting of20 min rest in a horizontal position, tilt to 80 deg upright for 10 min, and then return to the horizontal position for 5 min. The tilts were performed in darkness (supine and prone) or in light (supine only). Background music was used to mask auditory orientation cues. Autonomic measurements included beat-to-beat recordings of blood pressure (Finapres), heart rate (ECG), cerebral blood flow velocity in the middle cerebral artery (transcranial Doppler), end tidal CO2, respiratory rate and volume (Respritrace), and stroke volume (impedance cardiography). For both patients and control subjects, cerebral blood flow appeared to exhibit the most rapid adjustment following transient changes in posture. Outside of a greater cerebral hypoperfusion in patients during the later stages of tilt, responses did not differ dramatically between the vestibular loss and control subjects, or between tilts performed in light and dark room conditions. Thus, with the 'exception of cerebrovascular regulation, we conclude that orthostatic responses during slow postural tilts are not substantially impaired in humans following chronic loss of vestibular function, a result that might reflect compensation by nonvisual graviceptor inputs (e.g., somatosensory) or other circulatory reflex mechanisms.

Wood, Scott J.↗

Motion Perception and Manual Control Performance During Passive Tilt and Translation Following Space Flight

This joint ESA-NASA study is examining changes in motion perception following Space Shuttle flights and the operational implications of post-flight tilt-translation ambiguity for manual control performance. Vibrotactile feedback of tilt orientation is also being evaluated as a countermeasure to improve performance during a closed-loop nulling task. METHODS. Data has been collected on 5 astronaut subjects during 3 preflight sessions and during the first 8 days after Shuttle landings. Variable radius centrifugation (216 deg/s) combined with body translation (12-22 cm, peak-to-peak) is utilized to elicit roll-tilt perception (equivalent to 20 deg, peak-to-peak). A forward-backward moving sled (24-390 cm, peak-to-peak) with or without chair tilting in pitch is utilized to elicit pitch tilt perception (equivalent to 20 deg, peak-to-peak). These combinations are elicited at 0.15, 0.3, and 0.6 Hz for evaluating the effect of motion frequency on tilt-translation ambiguity. In both devices, a closed-loop nulling task is also performed during pseudorandom motion with and without vibrotactile feedback of tilt. All tests are performed in complete darkness. PRELIMINARY RESULTS. Data collection is currently ongoing. Results to date suggest there is a trend for translation motion perception to be increased at the low and medium frequencies on landing day compared to pre-flight. Manual control performance is improved with vibrotactile feedback. DISCUSSION. The results of this study indicate that post-flight recovery of motion perception and manual control performance is complete within 8 days following short-duration space missions. Vibrotactile feedback of tilt improves manual control performance both before and after flight.

Clement, Gilles↗

A Dynamo Simulation Generating Saturn-Like Small Magnetic Dipole Tilts

Abstract Among planetary dynamos, the magnetic field of Saturn stands out in its exceptional level of axisymmetry. One of its peculiar features is that the magnetic dipole mode is tilted with respect to the planetary rotation axis by only ≈0.007° or less. Numerical dynamo simulations performed in this context have had great difficulty in producing such small dipole tilt angles without introducing ad hoc ingredients such as a latitudinally varying heat flux pattern in the outer layers or stably stratified layers (SSLs). Here we present a numerical dynamo simulation that generates a highly axisymmetric dynamo with a dipole tilt of about ≈0.0008° on average. The model consists of a deep dynamo layer and an overlying low-conductivity layer but without any SSLs. We highlight a novel mechanism where strong differential rotation generated in the atmospheric layer penetrates into the dynamo region, helping to maintain a very small magnetic dipole tilt. Plain Language Summary Saturn's dipole-dominant magnetic field exhibits a very peculiar feature: the dipole component of the planetary magnetic field is tilted by less than ≈0.007° with respect to the planetary spin axis. Numerical simulations performed in this context suggest that if a spatial heat-flux variation is imposed, along with a stably stratified region, on top of an active dynamo layer, then small dipole tilt values can be realized. Here we present a model where extremely small dipole tilt values can be achieved without these ad hoc ingredients. Our simulations demonstrate that dynamo theory allows extremely small dipole tilt values in a relatively simple model configuration.

Rakesh Kumar Yadav↗

Speed benefits of tilt-rotor designs for LHX

The merits of an advanced helicopter and a tilt rotor aircraft for light utility, scout, and attack roles in combat missions envisioned for the year 2000 and beyond were compared. It is demonstrated that speed has increasing value for 11 different mission classes broadly encompassing the intended LHX roles. Helicopter speeds beyond 250 knots are judged to have lower military worth. Since the tilt rotor concept offers a different cost speed relationship than that of helicopters, assessment of a tilt rotor LHX variant was warranted. The technical parameters of an advanced tilt rotor are stablished. Parameters of representative missions are identified, computed relative value of the tilt rotor LHX are compared to the baseline helicopter, a first-order life cycle estimate for the tilt rotor LHX is established, military worth of the alternative design is computed and the results are evaluated. It is suggested that the tilt rotor is the solution with the greatest capability for meeting the uncertainties of future needs.

Mcdaniel, R. L.↗

Effects of exercise-heat acclimation on fluid, electrolyte, and endocrine responses during tilt and +Gz acceleration in women and men

Two aspects of prolonged endurance training were investigated: (1) the effects of exercise-heat acclimation (on a cycle ergometer at 40 C, 42 rh) on orthostatic tolerance (70 deg head-up tilt) and on a +Gz (head-to-foot) acceleration tolerance of male and female subjects; and (2) comparison of their fluid-electrolyte shifts and hormonal (plasma epinephdrine, norepinephrine, renin, and vasopressin) responses during tilting and centrifugation. The adaptive responses during the 12 d, 2-h acclimation did not alter acceleration tolerance of either men or women, or the women's tilt tolerance, but did increase men's tilt tolerance from 30.4 min before to 58.3 min after acclimation. The patterns of fluid, electrolyte, and protein shifts at tolerance in acceleration and tilting tests were virtually the same in men and women. On the other hand, the hormonal plasma epinephrine, norepinephrine, renin, and vasopressin resonses displayed different shift patterns during acceleration and tilting. It is concluded that the responses to tilting cannot be used to predict responses to acceleration. Future experiments for relating the orthostatic and the acceleration tolerances, and the practical questions of the training regimens for future astronauts are discussed.

Greenleaf, J. E.↗

A strategy for advancing tilt-rotor technology

Tilt-rotor technology has many features which make it a very promising development in aviation which might have application to a wide variety of transportation and logistics situations. However, aside from military applications and rather specialized industrial applications, little is known regarding the potential of tilt-rotor for commercial transportation and hence it is difficult to plan a development program which would gain support and be likely to produce a stream of significant benefits. The purpose is to attempt to provide some of this information in a manner that would be useful for preparing a strategy for development of tilt-rotor aircraft technology. Specifically, the objectives were: to identify promising paths of development and deployment of tilt-rotor aircraft technology in the air transportation system considering both benefits and disbenefits, and to identify any particular groups that are likely to benefit significantly and propose plans for gaining their support of research and development of this technology. Potential advantages of the tilt-rotor technology in the context of air transportation as a door-to-door system were identified, and then promising paths of development of such tilt-rotor systems were analyzed. These then lead to recommendations for specific studies, information dissemination and development of awareness of the tilt-rotor among specific transport-related groups.

Morlok, Edward K.↗

The effects of dipole tilt on magnetotail structure and dynamics

A three-dimensional time-dependent global magnetohydrodynamic (MHD) model of the interaction between the solar wind and the earth's magnetosphere has been used to study the effects of dipole tilt on the structure and dynamics of the magnetotail. The location of the tail neutral sheet shifts in the north-south direction following changes in the dipole tilt. When the northern edge of the geomagnetic dipole is tilted toward the sun (positive tilt), it is above the geocentric solar magnetosphere (GSM) equator, while for negative tilt, it is below. The neutral sheet forms an arc across the tail in the y-z plane for nonzero tilt. For positive tilt, the neutral sheet rises above the GSM equatorial plane near the noon-midnight meridian and returns to the equator near the magnetopause. The position and shape of the neutral sheet result from the requirement that the earthward magnetic flux equals the tailward flux and can be well explained by a simple analytical model.

Walker, Raymond J.↗

Vertical tilts of tropospheric waves - Observations and theory

Two methods are used to investigate the vertical tilts of planetary waves as functions of zonal wavenumber and frequency. The vertical tilts are computed by cross-spectral analysis of the geopotential heights at different pressures. In the midlatitude troposphere, the eastward-moving waves had a westward tilt with height, as expected, but the westward-moving waves with frequencies higher than 0.2/d showed statistically significant eastward vertical tilts. For a free Rossby wave, this implies that the Eliassen-Palm flux is downward along with its energy propagation. A downward energy propagation suggests an upper-level source of these waves. It is proposed that the eastward-tilting waves were forced by the nonlinear interaction of stationary waves and baroclinically unstable cyclone-scale waves. The predicted vertical tilt and phase speed were consistent with the observations. In addition, simulations of a general circulation model were analyzed. In the control run, eastward-tilting waves disappeared when the sources of stationary waves were removed. This is consistent with the present theory.

Ebisuzaki, Wesley↗

Tilt Rotor Aircraft Aeroacoustics

A fleet of civil tilt rotor transports offers a means of reducing airport congestion and point-to-point travel time. The speed, range, and fuel economy of these aircraft, along with their efficient use of vertiport area, make them good candidates for short-to-medium range civil transport. However, to be successfully integrated into the civilian community, the tilt rotor must be perceived as a quiet, safe, and economical mode of transportation that does not harm the environment. In particular, noise impact has been identified as a possible barrier to the civil tilt rotor. Along with rotor conversion-mode flight, and blade-vortex interaction noise during descent, hover mode is a noise problem for tilt rotor operations. In the present research, tilt rotor hover aeroacoustics have been studied analytically, experimentally, and computationally. Various papers on the subject were published as noted in the list of publications. More recently, experimental measurements were made on a 1/12.5 scale model of the XV-15 in hover and analyses of this data and extrapolations to full scale were also carried out. A dimensional analysis showed that the model was a good aeroacoustic approximation to the full-scale aircraft, and scale factors were derived to extrapolate the model measurements to the full-scale XV-15. The experimental measurements included helium bubble flow visualization, silk tuft flow visualization, 2-component hot wire anemometry, 7-hole pressure probe measurements, vorticity measurements, and outdoor far field acoustic measurements. The hot wire measurements were used to estimate the turbulence statistics of the flow field into the rotors, such as length scales, velocity scales, dissipation, and turbulence intermittency. Several different configurations of the model were tested: (1) standard configurations (single isolated rotor, two rotors without the aircraft, standard tilt rotor configuration); (2) flow control devices (the 'plate', the 'diagonal fences'); (3) basic configuration changes (increasing the rotor/rotor spacing, reducing the rotor plane/wing clearance. operating the rotors out of phase). Also, an approximation to Sikorsky's Variable Diameter Tilt Rotor (VDTR) configuration was tested, and some flow measurements were made on a semi-span configuration of the model. Acoustic predictions were made using LOWSON.M, a Mathematica code Mean aerodynamic models were developed based on hover performance predictions from HOVER.FOR. This hover prediction code used blade element theory for the aerodynamics, and Prandtl's Vortex theory to model the wake, along with empirical formulas for the effects of Reynolds number, Mach number, and stall. Aerodynamic models were developed from 7-hole pressure probe measurements of the mean velocity into the model rotors.

George, Albert R.↗

Low-Frequency Otolith Function in Microgravity: A Re-Evaluation of the Otolith Tilt-Translation Reinterpretation (OTTR) Hypothesis

On Earth, the low-frequency afferent signal from the otoliths encodes head tilt with respect to the gravitational vertical, and the higher frequency components reflect both tilt and linear acceleration of the head. In microgravity, static tilt of the head does not influence otolith output, and the relationship between sensory input from the vestibular organs, and the visual, proprioceptive and somatosensory systems, would be disrupted. Several researchers have proposed that in 0-g this conflict may induce a reinterpretation of all otolith signals by the brain to encode only linear translation (otolith tilt-translation reinterpretation or OTTR). Ocular counter-rolling (OCR) is a low-frequency otolith-mediated reflex, which generates compensatory torsional eye movements (rotation about the visual axis) towards the spatial vertical during static roll tilt with a gain of approximately 10%. Transient linear acceleration and off-axis centrifugation at a constant angular velocity can also generate OCR. According to the OTTR hypothesis, OCR should be reduced in microgravity, and immediately upon return from a 0-g environment. Results to date have been inconclusive. OCR was reduced following the 10 day Spacelab-1 mission in response to leftward roll tilts (28-56% in 3 subjects and unchanged in one subject), and sinusoidal linear oscillations at 0.4 and 0.8 Hz. OCR gain declined 70% in four monkeys following a 14 day COSMOS mission. Following a 30 day MIR mission OCR gain decreased in one astronaut, but increased in two others following a 180 day mission. We have studied the affect of microgravity on low-frequency otolith function as part of a larger study of the interaction of vision and the vestibular system. This experiment (E-047) involved off-axis centrifugation of payload crewmembers and flew aboard the recent Neurolab mission (STS 90). Presented below are preliminary results focusing on perception and the OCR response during both centrifugation and static tilt.

Moore, Steven T.↗

The History of the XV-15 Tilt Rotor Research Aircraft: From Concept to Flight

This monograph is a testament to the efforts of many people overcoming multiple technical challenges encountered while developing the XV-15 tilt rotor research aircraft. The Ames involvement with the tilt rotor aircraft began in 1957 with investigations of the performance and dynamic behavior of the Bell XV-3 tilt rotor aircraft. At that time, Ames Research Center was known as the Ames Aeronautical Laboratory of the National Advisory Committee for Aeronautics (NACA). As we approach the new millennium, and after more than 40 years of effort and the successful completion of our initial goals, it is appropriate to reflect on the technical accomplishments and consider the future applications of this unique aircraft class, the tilt rotor. The talented engineers, technicians, managers, and leaders at Ames have worked hard with their counterparts in the U.S. rotorcraft industry to overcome technology barriers and to make the military and civil tilt rotor aircraft safer, environmentally acceptable, and more efficient. The tilt rotor aircraft combines the advantages of vertical takeoff and landing capabilities, inherent to the helicopter, with the forward speed and range of a fixed wing turboprop airplane. Our studies have shown that this new vehicle type can provide the aviation transportation industry with the flexibility for highspeed, long-range flight, coupled with runway-independent operations, thus having a significant potential to relieve airport congestion. We see the tilt rotor aircraft as an element of the solution to this growing air transport problem.

Maisel, Martin D.↗

Human muscle sympathetic neural and haemodynamic responses to tilt following spaceflight

Orthostatic intolerance is common when astronauts return to Earth: after brief spaceflight, up to two-thirds are unable to remain standing for 10 min. Previous research suggests that susceptible individuals are unable to increase their systemic vascular resistance and plasma noradrenaline concentrations above pre-flight upright levels. In this study, we tested the hypothesis that adaptation to the microgravity of space impairs sympathetic neural responses to upright posture on Earth. We studied six astronauts approximately 72 and 23 days before and on landing day after the 16 day Neurolab space shuttle mission. We measured heart rate, arterial pressure and cardiac output, and calculated stroke volume and total peripheral resistance, during supine rest and 10 min of 60 deg upright tilt. Muscle sympathetic nerve activity was recorded in five subjects, as a direct measure of sympathetic nervous system responses. As in previous studies, mean (+/- S.E.M.) stroke volume was lower (46 +/- 5 vs. 76 +/- 3 ml, P = 0.017) and heart rate was higher (93 +/- 1 vs. 74 +/- 4 beats min(-1), P = 0.002) during tilt after spaceflight than before spaceflight. Total peripheral resistance during tilt post flight was higher in some, but not all astronauts (1674 +/- 256 vs. 1372 +/- 62 dynes s cm(-5), P = 0.32). No crew member exhibited orthostatic hypotension or presyncopal symptoms during the 10 min of postflight tilting. Muscle sympathetic nerve activity was higher post flight in all subjects, in supine (27 +/- 4 vs. 17 +/- 2 bursts min(-1), P = 0.04) and tilted (46 +/- 4 vs. 38 +/- 3 bursts min(-1), P = 0.01) positions. A strong (r(2) = 0.91-1.00) linear correlation between left ventricular stroke volume and muscle sympathetic nerve activity suggested that sympathetic responses were appropriate for the haemodynamic challenge of upright tilt and were unaffected by spaceflight. We conclude that after 16 days of spaceflight, muscle sympathetic nerve responses to upright tilt are normal.

Non-NASA Center↗

Echocardiograms during six hours of bedrest at head-down and head-up tilt and during space flight

Left ventricular end-diastolic volume increased after 4 1/2 to 6 hours of space flight, but was significantly decreased after 5 to 6 days of space flight. To determine the role of acute gravitational effects in this phenomenon, responses to a 6-hour bedrest model of 0 gravity (G; 5 degrees head-down tilt) were compared with those of fractional gravity loads of 1/6 G, 1/3 G, and 2/3 G by using head-up tilts of 10 degrees, 20 degrees, and 42 degrees, respectively. On 4 different days, six healthy male subjects were tilted at one of the four angles for 6 hours. Cardiac dimensions and volumes were determined from two-dimensional and M-mode echocardiograms in the left lateral decubitus position at control (0), 2, 4, and 6 hours. Stroke volume decreased with time (P < .05) for all tilt angles when compared with control. Ejection fraction (EF) at -5 degrees was greater than at +20 degrees and +42 degrees (not significant); EF at +10 degrees was greater than at +42 degrees (not significant). For the tilt angles of -5 degrees, +10 degrees, and +20 degrees, mean heart rate decreased during the first 2 hours, and returned to control or was slightly elevated above control (+20 degrees) by 6 hours (not significant). At the +42 degrees angle of tilt, heart rate was increased above control at hours 2, 4, and 6. There were no significant differences in cardiac output at any time point for any tilt angle.(ABSTRACT TRUNCATED AT 250 WORDS).

Flight Experiment↗

Human Ocular Counter-Rolling and Roll Tilt Perception during Off-Vertical Axis Rotation after Spaceflight

Ocular counter-rolling (OCR) induced by whole body tilt in roll has been explored after spaceflight as an indicator of the adaptation of the otolith function to microgravity. It has been claimed that the overall pattern of OCR responses during static body tilt after spaceflight is indicative of a decreased role of the otolith function, but the results of these studies have not been consistent, mostly due to large variations in the OCR within and across individuals. By contrast with static head tilt, off-vertical axis rotation (OVAR) presents the advantage of generating a sinusoidal modulation of OCR, allowing averaged measurements over several cycles, thus improving measurement accuracy. Accordingly, OCR and the sense of roll tilt were evaluated in seven astronauts before and after spaceflight during OVAR at 45 /s in darkness at two angles of tilt (10 and 20 ). There was no significant difference in OCR during OVAR immediately after landing compared to preflight. However, the amplitude of the perceived roll tilt during OVAR was significantly larger immediately postflight, and then returned to control values in the following days. Since the OCR response is predominantly attributed to the shearing force exerted on the utricular macula, the absence of change in OCR postflight suggests that the peripheral otolith organs function normally after short-term spaceflight. However, the increased sense of roll tilt indicates an adaptation in the central processing of gravitational input, presumably related to a re-weigthing of the internal representation of gravitational vertical as a result of adaptation to microgravity.

Clement, Gilles↗