Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “thermal response functions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Fluid Structure Interaction in a Turbine Blade

An unsteady, three dimensional Navier-Stokes solution in rotating frame formulation for turbomachinery applications is presented. Casting the governing equations in a rotating frame enabled the freezing of grid motion and resulted in substantial savings in computer time. The turbine blade was computationally simulated and probabilistically evaluated in view of several uncertainties in the aerodynamic, structural, material and thermal variables that govern the turbine blade. The interconnection between the computational fluid dynamics code and finite element structural analysis code was necessary to couple the thermal profiles with the structural design. The stresses and their variations were evaluated at critical points on the Turbine blade. Cumulative distribution functions and sensitivity factors were computed for stress responses due to aerodynamic, geometric, mechanical and thermal random variables.

Gorla, Rama S. R.↗

Fire resistant aircraft seat materials

The establishment of a technical data base for individual seat materials in order to facilitate materials selections is reviewed. The thermal response of multi-layer constructions representative of the basic functional layers of a typical future seat is examined. These functional layers include: (1) decorative fabric cover; (2) slip sheet (topper); (3) fire blocking layer; (4) cushion reinforcement; and (5) cushioning layer. The implications for material selection for full-scale seats are discussed.

Trabold, E. L.↗

A Technique Using Principal Component Analysis to Compare Seasonal Cycles of Earth Radiation from CERES and Model Computations

A method for quantitatively comparing the seasonal cycles of two global data sets is presented. The seasonal cycles of absorbed solar radiation (ASR) and outgoing longwave radiation (OLR) have been computed from an eight-year data set from the Clouds and Earth's Radiant Energy System (CERES) scanning radiometers and from a model data set produced by the NASA Goddard Space Flight Center Global Modeling and Assimilation Office. To compare the seasonal cycles from these two data sets, principal component (PC) analysis is used, where the PCs express the time variations and the corresponding empirical orthogonal functions (EOFs) describe the geographic variations. Ocean has a long thermal response time compared to land, so land and ocean are separated for the analysis. The root-mean square values for the seasonal cycles of ASR and OLR are extremely close for the two data sets. The first three PCs are quite close, showing that the time responses and magnitudes over the globe are very similar. The agreement between the two sets of PCs is quantified by computing the matrix of inner products of the two sets. For ASR over land, the first PCs of CERES and the model agree to better than 99.9%. The EOF maps are similar for most of the globe, but differ in a few places, and the agreement of the EOF maps is likewise quantified. Maps of differences between the annual cycles show regions of agreement and disagreement.

Smith, G. Louis↗

Physiologic and Functional Responses of MS Patients to Body Cooling Using Commercially Available Cooling Garments

Personal cooling systems are widely used in industrial and aerospace environments to alleviate thermal stress. Increasingly they are also used by heat sensitive multiple sclerosis (HSMS) patients to relieve symptoms and improve quality of life. There are a variety of cooling systems commercially available to the MS community. However, little information is available regarding the comparative physiological changes produced by routine operation of these various systems. The objective of this study was to document and compare the patient response to two passive cooling vests and one active cooling garment. The Life Enhancement Technology, Inc. (LET) lightweight active cooling vest with cap, the MicroClimate Systems (MCS) Change of Phase garment, and the Steele Vest were each used to cool 13 male and 13 female MS subjects (31 to 67 yr.) in this study. The subjects, seated in an upright position at normal room temperature (approximately 22 C), were tested with one of the cooling garments. Oral, fight and left ear temperatures were logged manually every 5 min. An-n, leg, chest and rectal temperatures; heart rate; and respiration were recorded continuously on a U.F.I., Inc. Biolog ambulatory monitor. Each subject was given a series of subjective and objective evaluation tests before and after cooling. The LET and Steele vests test groups had similar, significant (P less than 0.01) cooling effects on oral and ear canal temperature, which decreased approximately 0.4 C, and 0.3 C, respectively. Core temperature increased (N.S.) with all three vests during cooling. The LET vest produced the coldest (P less than 0.01) skin temperature. Overall, the LET vest provided the most improvement on subjective and objective performance measures. These results show that the garment configurations tested do not elicit a similar thermal response in all MS patients. Cooling with the LET active garment configuration resulted in the lowest body temperatures for the MS subjects; cooling with the MCS vest was least effective. For functional responses, the LET test group performed better than the other two vests.

Ku, Yu-Tsuan E.↗

Infrared image analysis of volcanic thermal features - Lascar Volcano, Chile, 1984-1992

Fifteen Landsat TM images of Lascar volcano (Chile), recorded between December 1984 and April 1992, document the evolution of a lava dome within the summit crater. In every image, the two short-wavelength infrared bands, 5 and 7, have detected thermal radiation from the volcano. As a consequence of the Planck distribution function, the relative response of these two channels depends on the proportions of very hot surfaces occupying tiny pixel areas and broader regions at moderate temperatures. Intercomparison of bands 5 and 7 thereby provides a means for interpreting TM thermal anomalies even in the absence of ground observations. Pronounced changes in the configuration and intensity of the Lascar anomaly suggest that the volcano has experienced at least two cycles of lava dome activity since 1984. The first of these progressed through a 'cooling' period, possibly reflecting a reduced flux of magmatic volatiles at the surface, and culminated in an explosive eruption on September 16, 1986, which appears to have completely destroyed the inferred lava dome.

Oppenheimer, Clive↗

Electron distributions in quasi-perpendicular shocks: Simulations

One of the outstanding problems of collisionless shock physics is the microphysical description of electron thermalization and associated wave processes. Observations at the Earth's bow shock have shown various features in the electron velocity distribution such as a loss-cone, temperature anisotropies, and beams before a thermalized, flat-topped distribution is reached downstream. It is generally believed that in addition to the macroscopic fields, which determine the overall mapping of the distribution function, electromagnetic whistler waves and lower hybrid waves are responsible for the pitch-angle scattering and thermalization of the electrons. However, a genuine physical explanation requires analysis of the evolution of the electron distribution in the self-consistent wave fields. Particle simulations are ideally suited to do this, and include processes in which both electrons and ions are involved, such as cross-field streaming instabilities. We show results from l-D and 2-D simulations using an implicit code, which allows time steps large compared to the inverse electron plasma frequency. It is shown that in order to capture the correct propagation characteristics of the waves, a large mass ratio between the protons and electrons is generally necessary. Detailed diagnostics of the waves as well as the evolution of the electron velocity distribution will be presented and will be discussed in the frame work of satellite observations.

Pantellini, F.↗

Functional and dynamics testing of the flexible solar array for the communications technology satellite

The test objectives, test methods, thermal environmental simulations, and test results are described, for a series of combined dynamic, thermal, and vacuum environmental tests on a Deployable Solar Array for the Communications Technology Satellite. Six major resonant structural modes were observed over an excitation range of 0.1-1.0 Hz. Corresponding modal damping factors were found to be between 0.001 and 0.01. Variation of temperature environments between -125 C and 42 C did not significantly affect the characteristics of the fundamental modes, but did influence some of the higher modes. Superharmonic response behavior was observed. The tests also verified functional mechanical performance of the solar array under thermal and vacuum conditions.

Harrison, T. D.↗

Thermal Property Parameter Estimation of TPS Materials

Accurate knowledge of the thermophysical properties of TPS (thermal protection system) materials is necessary for pre-flight design and post-flight data analysis. Thermal properties, such as thermal conductivity and the volumetric specific heat, can be estimated from transient temperature measurements using non-linear parameter estimation methods. Property values are derived by minimizing a functional of the differences between measured and calculated temperatures. High temperature thermal response testing of TPS materials is usually done in arc-jet or radiant heating facilities which provide a quasi one-dimensional heating environment. Last year, under the NASA-ASEE-Stanford Fellowship Program, my work focused on developing a radiant heating apparatus. This year, I have worked on increasing the fidelity of the experimental measurements, optimizing the experimental procedures and interpreting the data.

Maddren, Jesse↗

Assessment of Terra MODIS Thermal Emissive Band Calibration Using Cold Targets and Measurements in Lunar Roll Events

Terra MODIS has provided continuous global observations for science research and applications for more than 18 years. The MODIS Thermal emissive bands (TEB) radiometric calibration uses a quadratic function for instrument response. The calibration coefficients are updated using the response of an on-board blackbody (BB) in quarterly warm-up and cool-down (WUCD) events. As instrument degradation and electronic crosstalk of long-wave infrared (LWIR) bands 27 to 30 developed substantial issues, accurate calibration is crucial for a high-quality L1B product. The on-board BB WUCD temperature ranges from 270 K to 315 K and the derived nonlinear response has a relatively large uncertainty for the offset, especially for these LWIR bands, which affects the measurements of low brightness temperature (BT) scenes. In this study, the TEB radiometric calibration impact on the L1B product is assessed using selected cold targets and the measurements during regular lunar rolls. The cold targets include Antarctic Dome Concordia (Dome-C) and deep convective clouds (DCC) for the calibration assessment, focusing on bands 27 to 30. Dome-C area is covered with uniformly-distributed permanent snow, and the atmospheric effect is small and relatively constant. Usually the DCC is treated as an invariant earth target to evaluate the reflective solar band calibration. The DCC can also be treated as a stable target to assess the performance of TEB calibration. During a scheduled lunar observation event with a spacecraft roll maneuver to view the moon through the space view port, the instrument cavity provides a stable reference for calibration assessment. The long-term trending of BT measurements and the relative difference between scan mirror sides and detectors are used for the assessment of the calibration consistency and stability. The comparison of L1B products over the selected targets before and after the calibration coefficients update can be used to assess the impact of a calibration look-up table (LUT) update. This assessment is beneficial for future calibration algorithm and LUT update procedure improvements for enhancing the L1B product quality.

Chang, Tiejun↗

Response of thermal ions to electromagnetic ion cyclotron waves

Electromagnetic ion cyclotron waves generated by 10 - 50 keV protons in the Earth's equatorial magnetosphere will interact with the ambient low-energy ions also found in this region. We examine H(+) and He(+) distribution functions from approx. equals 1 to 160 eV using the Hot Plasma Composition Experiment instrument on AMPTE/CCE to investigate the thermal ion response to the waves. A total of 48 intervals were chosen on the basis of electromagnetic ion cyclotron (EMIC) wave activity: 24 with prevalent EMIC waves and 24 with no EMIC waves observed on the orbit. There is a close correlation between EMIC waves and perpendicular heated ion distributions. For protons the perpendicular temperature increase is modest, about 5 eV, and is always observed at 90 deg pitch angles. This is consistent with a nonresonant interaction near the equator. By contrast, He(+) temperatures during EMIC wave events averaged 35 eV and sometimes exceeded 100 eV, indicating stronger interaction with the waves. Furthermore, heated He(+) ions have X-type distributions with maximum fluxes occurring at pitch angles intermediate between field-aligned and perpendicular directions. The X-type He(+) distributions are consistent with a gyroresonant interaction off the equator. The concentration of He(+) relative to H(+) is found to correlate with EMIC wave activity, but it is suggested that the preferential heating of He(+) accounts for the apparent increase in relative He(+) concentration by increasing the proportion of He(+) detected by the ion instrument.

Anderson, B. J.↗

Characterization of Composite Damage Using Passive Thermography

Passive thermography is used to monitor small increases in temperature on a composite structure during loading. A rise in temperature can be attributed to damage formation due to matrix cracking and fiber breaks. An infrared camera allows for imaging the damage location, size, and shape. Recently, a technique has been developed to estimate the depth of the damage in a composite hat-stiffened panel during quasi-static loading. This technique is based on two heat generation components. The first component is an instantaneous thermoelastic response due to a strain release. The second component is mechanical heating, at the interface of failure, due to fracture damage. This second component produces a transient rise in temperature that is a function of the damage depth and thermal diffusivity. The first component defines the thermal start time for the transient response. A one-dimensional thermal model is used to determine the damage depth for a known thermal diffusivity. The results are compared to ultrasonic and X-ray CT data and show good agreement for damage depth.

Thermal nondestructive evaluation↗

Environmental loading effects on structures

The environment in which a structure vibrates influences its modal characteristics. Presented herein is experimental modal survey test results on splitter vanes under liquid nitrogen mass-pressure-thermal loading. In particular, shifts in modal frequencies are studied via frequency response functions, power spectral densities, isoplots, quadrature or imaginary plots, and vibration mode shape characteristics generated from strain and acceleration measurements. Analyses have shown that while mass loading lowers the frequencies, increased pressure and lower temperature have opposite effect. Thus, pressurization and cooling of a liquid causes the modal frequencies of the structure in which it is contained to shift upward.

Panossian, H. V.↗

A case study demonstration of the soil temperature extrema recovery rates after precipitation cooling at 10-cm soil depth

Since the invention of maximum and minimum thermometers in the 18th century, diurnal temperature extrema have been taken for air worldwide. At some stations, these extrema temperatures were collected at various soil depths also, and the behavior of these temperatures at a 10-cm depth at the Tifton Experimental Station in Georgia is presented. After a precipitation cooling event, the diurnal temperature maxima drop to a minimum value and then start a recovery to higher values (similar to thermal inertia). This recovery represents a measure of response to heating as a function of soil moisture and soil property. Eight different curves were fitted to a wide variety of data sets for different stations and years, and both power and exponential curves were fitted to a wide variety of data sets for different stations and years. Both power and exponential curve fits were consistently found to be statistically accurate least-square fit representations of the raw data recovery values. The predictive procedures used here were multivariate regression analyses, which are applicable to soils at a variety of depths besides the 10-cm depth presented.

Welker, Jean Edward↗

Structural design of the Large Deployable Reflector (LDR)

An integrated Large Deployable Reflector (LDR) analysis model was developed to enable studies of system responses to the mechanical and thermal disturbances anticipated during on-orbit operations. Functional requirements of the major subsystems of the LDR are investigated, design trades are conducted, and design options are proposed. System mass and inertia properties are computed in order to estimate environmental disturbances, and in the sizing of control system hardware. Scaled system characteristics are derived for use in evaluating launch capabilities and achievable orbits. It is concluded that a completely passive 20-m primary appears feasible for the LDR from the standpoint of both mechanical vibration and thermal distortions.

Satter, Celeste M.↗

MODIS Thermal Emissive Bands Calibration Improvements for Collection 7

The MODIS thermal emissive bands (TEB) radiometric calibration uses a quadratic function for the instrument response, and the calibration coefficients look-up tables (LUTs) are updated using the response of an on-board blackbody (BB). After more than 21 and 19 years on-orbit, the TEB performances for Terra and Aqua MODIS have been generally stable. However, contamination from electronic crosstalk, a known issue since prelaunch, has affected the L1B image quality and measurement accuracy. In addition to the photovoltaic (PV) longwave infrared (LWIR) bands crosstalk correction included in Terra MODIS Collection 6.1 (C6.1), a crosstalk correction for select detectors in the Terra and Aqua mid-wave infrared (MWIR) and Aqua PV LWIR bands are applied in C7. The mission-long crosstalk coefficients for the selected detectors are derived and populated in the form of LUTs. The crosstalk correction is applied to both on-orbit calibration and the algorithm used to generate Earth-view L1B products. Among these detectors, the Aqua MODIS band 24 detector 1 crosstalk has the largest impact on image quality, with striping observed over cold scenes for both Terra and Aqua MODIS. The images of C7 L1B and C6.1 are compared to assess the impact of the correction. Additional assessments using Earthview measurements and inter-comparison also revealed the need for improvement of calibration stability and consistence for select bands. Additional improvements for long-term stability and mirror side consistence were developed using quasideep convective clouds (qDCC), Dome-C, ocean, desert, and inter-comparison with other instruments.

MODIS↗

Entropy generation method to quantify thermal comfort

The present paper presents a thermodynamic approach to assess the quality of human-thermal environment interaction and quantify thermal comfort. The approach involves development of entropy generation term by applying second law of thermodynamics to the combined human-environment system. The entropy generation term combines both human thermal physiological responses and thermal environmental variables to provide an objective measure of thermal comfort. The original concepts and definitions form the basis for establishing the mathematical relationship between thermal comfort and entropy generation term. As a result of logic and deterministic approach, an Objective Thermal Comfort Index (OTCI) is defined and established as a function of entropy generation. In order to verify the entropy-based thermal comfort model, human thermal physiological responses due to changes in ambient conditions are simulated using a well established and validated human thermal model developed at the Institute of Environmental Research of Kansas State University (KSU). The finite element based KSU human thermal computer model is being utilized as a "Computational Environmental Chamber" to conduct series of simulations to examine the human thermal responses to different environmental conditions. The output from the simulation, which include human thermal responses and input data consisting of environmental conditions are fed into the thermal comfort model. Continuous monitoring of thermal comfort in comfortable and extreme environmental conditions is demonstrated. The Objective Thermal Comfort values obtained from the entropy-based model are validated against regression based Predicted Mean Vote (PMV) values. Using the corresponding air temperatures and vapor pressures that were used in the computer simulation in the regression equation generates the PMV values. The preliminary results indicate that the OTCI and PMV values correlate well under ideal conditions. However, an experimental study is needed in the future to fully establish the validity of the OTCI formula and the model. One of the practical applications of this index is that could it be integrated in thermal control systems to develop human-centered environmental control systems for potential use in aircraft, mass transit vehicles, intelligent building systems, and space vehicles.

Models, Biological↗

Microwave conductivity of laser ablated YBaCuO superconducting films and its relation to microstrip transmission line

The discovery of high temperature superconductor oxides has raised the possibility of a new class of millimeter and microwave devices operating at temperatures considerably higher than liquid helium temperatures. Therefore, materials properties such as conductivity, current density, and sheet resistance as a function of temperature and frequency, possible anisotropies, moisture absorption, thermal expansion, and others, have to be well characterized and understood. The millimeter wave response was studied of laser ablated YBa2Cu3O(7-x)/LaAlO3 thin films as a function of temperature and frequency. In particular, the evaluation of their microwave conductivity was emphasized, since knowledge of this parameter provides a basis for the derivation of other relevant properties of these superconducting oxides, and for using them in the fabrication of actual passive circuits. The microwave conductivity for these films was measured at frequencies from 26.5 to 40.0 GHz, in the temperature range from 20 to 300 K. The values of the conductivity are obtained from the millimeter wave power transmitted through the films, using a two fluid model.

Bhasin, K. B.↗

Microwave conductivity of laser ablated YBa2Cu3O(7-delta) superconducting films and its relation to microstrip transmission line performance

The discovery of high temperature superconductor oxides has raised the possibility of a new class of millimeter and microwave devices operating at temperatures considerably higher than liquid helium temperatures. Therefore, materials properties such as conductivity, current density, and sheet resistance as a function of temperature and frequency, possible anisotropies, moisture absorption, thermal expansion, and others, have to be well characterized and understood. The millimeter wave response of laser ablated YBa2Cu3O(7-delta)/LaAlO3 thin films was studied as a function of temperature and frequency. In particular, the evaluation of their microwave conductivity was emphasized, since knowledge of this parameter provides a basis for the derivation of other relevant properties of these superconducting oxides, and for using them in the fabrication of actual passive circuits. The microwave conductivity for these films was measured at frequencies from 26.5 to 40.0 GHz, in the temperature range from 20 to 300 K. The values of the conductivity are obtained from the millimeter wave power transmitted through the films, using a two fluid model.

Bhasin, K. B.↗