At least 37 records · Page 2

Core Temperature Measurement During Submaximal Exercise: Esophageal, Rectal, and Intestinal Temperatures

The purpose of this study was to determine if intestinal temperature (Tin) might be in acceptable alternative to esophageal (Tes) and rectal temperature (Trec) to assess thermoregulation during supine exercise. We hypothesized that Tin would have values similar to Tes and a response time similar to Trec, but the rate of temperature change across time would not be different between measurement sites. Seven subjects completed a continuous supine protocol of 20 min of rest, 20 min of cycle exercise at 40% peak oxygen consumption (VO2pk), 20 min of cycle exercise at 65% V02pk, and 20 min of recovery. Tes, Trec, and Tin were recorded each min throughout the test. Temperatures were not different after 20 min of rest, but Trec was less than the Tes and Tin at the end of the 40% and 65% VO2pk stages. After 20 min of recovery, Tes was less than either Trec or Tin, which were not different from each other. Time to threshold for increased temperature from rest was greater for Trec than Tes but not different from Tin. Time to reach peak temperature was greater for Tin and Trec than Tes. Similarly, time to a decrease in temperature after exercise was greater for Trec than Tes, but not different from Tin. The rate of temperature change from threshold to the end of the 40% VO2pk stage was not different between measurement sites. However, the rate of change during recovery was more negative for Tes than Tin and Trec, which were different from each other. Measurement of Tin may he an acceptable alternative to Tes and Trec with an understanding of its limitations.

Lee, Stuart M. C.↗

Estimating the Mean Annual Surface Air Temperature at Armagh Observatory, Northern Ireland, and the Global Land-Ocean Temperature Index for Sunspot Cycle 24, the Current Ongoing Sunspot Cycle

As noted by Gray et al., Sir William Herschel was the first to suggest a possible close connection between the Sun and the Earth’s climate. The Sun, being the source of energy that impacts and drives the Earth’s climate system, displays a variety of changes over both short and long term time scales, the most obvious examples being the somewhat regular waxing and waning of sunspots with time (i.e., the sunspot cycle (SC)), first described by Samuel Heinrich Schwabe, a German apothecary and amateur astronomer who observed the Sun from Dessau, Germany, and the now well established variation of the Sun’s irradiance over the SC. Other factors related to the SC have been linked to changes in climate as well. Some of these other factors include the role of cosmic rays and the solar wind (i.e., the geomagnetic cycle) on climate, as well as the apparent close association between trends in global and northern hemispheric temperature and the length of the SC, although some investigators have described the inferred association between climate and, in particular, SC length as now being weak. More recently, Solheim et al. have reported on the relation between SC length and the average temperature in the same and immediately following SC for a number of meteorological stations in Norway and in the North Atlantic region. They noted that while they found no significant trend (correlation) between SC length and the average temperature when measured for the same cycle, in contrast, they found a significant negative trend when SC length was compared with the following cycle’s average temperature. From this observation, they suggested that average northern hemispheric temperature during the present ongoing SC (SC24) will be lower by about 0.9 °C than was seen in SC23 (spanning 1996–2007, based on yearly averages of sunspot number (SSN), and onset for SC24 occurring in 2008). The purpose of this Technical Publication (TP) is to examine the annual variations of the Armagh surface air temperature (ASAT) and the Global Land-Ocean Temperature Index (GLOTI) in relation to SSN and the SC in order to determine their likely values during SC24. Hence, it may provide insight as to whether solar forcing of global temperature is now lessening as a contributor to global warming, thereby indicating a possible cooling in the near term immediate future that potentially could ameliorate the effect of increased anthropogenic warming.

Wilson, Robert M.↗

Thresholds of Temperature and Time for Mars Sample Return: Final Report of The Mars Sample Return Temperature-Time Tiger Team

The time-temperature tiger team (T4) was chartered by NASA and ESA to evaluate the risks to the scientific return of the MSR samples if they are exposed to temperatures between +30 and +60 ⁰C for different amounts of time. This team consists of 13 scientists, who were selected based on their scientific background to represent the scientific disciplines that are expected to be the ones that will be the most affected if such heating were to happen. The expertise of the team will help to understand whether exposing the MSR samples to temperatures between +30 and +60 ⁰C will pose any risk to the sample integrity and therefore, to future scientific investigations. Key processes identified by the T4 were: the release of volatiles by desorption and sublimation and release from condensed phases (interiors, decomposition, dehydration); chemical reactions including gas-gas and gas-solid; deliquescence of hygroscopic salts; acid/base interactions (potential for extreme pH conditions); aqueous redox reactions, isotopic exchange (aqueous phases, minerals, gasses, organic phases); condensation and freezing (in the after-heating cooling phase) and interactions with the sample tube materials. There is potential for multiple interactions and overlapping effects. For inorganic materials and the records they represent, over both long time scales (hours to days) and short time scales (minutes to hours) no temperature excursion above +30 °C could be accommodated without loss of science (Figure 1.1). While there will be some robust constituents (feldspars, quartz, pyroxenes, etc.) that are unaffected, there will also be some less robust constituents (salts, phyllosilicates, radicals, etc.) that are affected across all temperature ranges ≤60 °C. For organic materials, in particular organic biosignatures, the risks reflect that preservation is reliant on a number of processes, and a change in one component within a sample tube can affect another. For organic materials, over long timescales of hours to days no temperature excursion above +30 °C could be accommodated without loss of science, but over shorter time scales (minutes to hours), raising the temperature to 40 °C could be manageable without major disruption to science, whereas temperatures above 40 °C would lead to significant losses. The consideration of these findings by the MSR team will help to maintain the fidelity of samples returned from Mars in the future and maximize scientific return when analyzed in Earth laboratories.

Mark A Sephton↗

Coronal temperatures and temperature gradients from OSO-7 spectroheliograms

Temperatures and temperature gradients for the outer corona are obtained from brightness gradients of EUV lines that were measured with the spectroheliograph on OSO-7. Brightness gradients show considerable deviations from isothermal model calculations that include collisional excitation and photoexcitation. A negative temperature gradient that gives both positive and negative ion-abundance gradients appears to be able to account for the discrepancy. For the 284-A of Fe XV, perhaps the strongest line from the outer corona, measurements during 1972 appear to be consistent with a temperature near 2.3 million K near the equator at about 1.3 solar radii from the solar center and with temperature-gradient values near -0.7 that extend from as low as 1.2 to about 1.8 solar radii. Temperatures from strong lines of Fe XIV and Fe XVI indicate that variations of about 200,000 K exist along lines of sight where emission is appreciable. There appears to be some agreement between these results and temperature measurements from ion abundances in the solar wind and the Doppler width of the 5303-A line.

Nakada, M. P.↗

Validation of Temperature Measurements from the Airborne Raman Ozone Temperature and Aerosol Lidar During SOLVE

The Airborne Raman Ozone, Temperature and Aerosol Lidar (AROTEL) participated in the recent Sage III Ozone Loss and Validation Experiment (SOLVE) by providing profiles of aerosols, polar stratospheric clouds (PSCs), ozone and temperature with high vertical and horizontal resolution. Temperatures were derived from just above the aircraft to approximately 60 kilometers geometric altitude with a reported vertical resolution of between 0.5 and 1.5 km. The horizontal footprint varied from 4 to 70 km. This paper explores the measurement uncertainties associated with the temperature retrievals and makes comparisons with independent, coincident, measurements of temperature. Measurement uncertainties range from 0.1 K to approximately 4 K depending on altitude and integration time. Comparisons between AROTEL and balloon sonde temperatures retrieved under clear sky conditions using both Rayleigh and Raman scattered data showed AROTEL approximately 1 K colder than sonde values. Comparisons between AROTEL and the Meteorological Measurement System (MMS) on NASA's ER-2 show AROTEL being from 2-3 K colder for altitudes ranging from 14 to 18 km. Temperature comparisons between AROTEL and the United Kingdom Meteorological Office's model showed differences of approximately 1 K below approximately 25 km and a very strong cold bias of approximately 12 K at altitudes between 30 and 35 km.

Burris, John↗

Effects of Stoichiometry on Transformation Temperatures and Actuator-Type Performance of NiTiPd and NiTiPdX High-Temperature Shape Memory Alloys

High-temperature shape memory NiTiPd and NiTiPdX (X=Au, Pt, Hf) alloys were produced with titanium equivalent (Ti+Hf) compositions of 50.5, 50.0, 49.5, and 49.0 at.%. Thermo-mechanical testing in compression was used to evaluate the transformation temperatures, transformation strain, work output, and permanent deformation behavior of each alloy to study the effects of quaternary alloying and stoichiometry on high-temperature shape memory alloy behavior. Microstructural evaluation showed the presence of second phases for all alloy compositions. No load transformation temperatures in the stoichiometric alloys were relatively unchanged by Au and Pt substitutions, while the substitution of Hf for Ti causes a drop in transformation temperatures. The NiTiPd, NiTiPdAu and NiTiPdHf alloys exhibited transformation temperatures that were highest in the Ti-rich compositions, slightly lower at stoichiometry, and significantly reduced when the Ti equivalent composition was less than 50 at.%. For the NiTiPdPt alloy, transformation temperatures were highest for the Ti-rich compositions, lowest at stoichiometry, and slightly higher in the Ni-rich composition. When thermally cycled under constant stresses of up to 300 MPa, all of the alloys had transformation strains, and therefore work outputs, which increased with increasing stress. In each series of alloys, the transformation strain and thus work output was highest for stoichiometric or Ti-rich compositions while permanent strain associated with the constant-load thermal cycling was lowest for alloys with Ni-equivalent-rich compositions. Based on these results, basic rules for optimizing the composition of NiTiPd alloys for actuator performance will be discussed.

Bigelow, Glen S.↗

Effect of Upper-Cycle Temperature on the Load-Biased, Strain-Temperature Response of NiTi

Over the past decade, interest in shape memory alloy based actuators has increased as the primary benefits of these solid-state devices have become more apparent. However, much is still unknown about the characteristic behavior of these materials when used in actuator applications. Recently we have shown that the maximum temperature reached during thermal cycling under isobaric conditions could significantly affect the observed mechanical response of NiTi (55 wt% Ni), especially the amount of transformation strain available for actuation and thus work output. The investigation we report here extends that original work to ascertain whether further increases in the upper-cycle temperature would produce additional changes in the work output of the material, which has a stress-free austenite finish temperature of 113 C, and to determine the optimum cyclic conditions. Thus, isobaric, thermal-cycle experiments were conducted on the aforementioned alloy at various stresses from 50-300 MPa using upper-cycle temperatures of 165, 200, 230, 260, 290, 320 and 350 C. The data indicated that the amount of applied stress influenced the transformation strain, as would be expected. However, the maximum temperature reached during the thermal excursion also plays an equally significant role in determining the transformation strain, with the maximum transformation strain observed during thermal cycling to 290 C. In situ neutron diffraction at stress and temperature showed that the differences in transformation strain were mostly related to changes in martensite texture when cycling to different upper-cycle temperatures. Hence, understanding this effect is important to optimizing the operation of SMA-based actuators and could lead to new methods for processing and training shape memory alloys for optimal performance.

Padula, Santo, II↗

External auditory canal temperature as an estimate of core temperature.

Measurement of rectal (T sub re), auditory canal (T sub ac), positioned 8 to 10 mm from the tympanic membrane, and mean skin temperature (mean T sub sk) in five men during various exercise regimens at an ambient temperature (T sub a) of 25 C (phase one) and in two men during rest and exercise at 5, 15, 25, and 35 C T sub a (phase two). The purpose was to determine if T sub ac can be used as an accurate estimate of core temperature. Previous observations that T sub ac was highly correlated with T sub re but T sub ac was consistently lower than T sub re are confirmed; the mean difference varied from 0.4 C at rest to 1.1 C at the end of exercise. It is concluded that auditory canal temperature cannot be utilized as an estimate of core temperature, but T sub ac may be used to estimate mean body temperature where very accurate measurements are not required.

Greenleaf, J. E.↗

The influence of snow depth and surface air temperature on satellite-derived microwave brightness temperature

Areas of the steppes of central Russia, the high plains of Montana and North Dakota, and the high plains of Canada were studied in an effort to determine the relationship between passive microwave satellite brightness temperature, surface air temperature, and snow depth. Significant regression relationships were developed in each of these homogeneous areas. Results show that sq R values obtained for air temperature versus snow depth and the ratio of microwave brightness temperature and air temperature versus snow depth were not as the sq R values obtained by simply plotting microwave brightness temperature versus snow depth. Multiple regression analysis provided only marginal improvement over the results obtained by using simple linear regression.

Foster, J. L.↗

The prediction of tropopause height from clusters of brightness temperatures and its application in the stratified regression temperature retrievals using microwave and infrared satellite measurements

A total of 1575 radiosondes and the corresponding simulated brightness temperatures were used in an effort to derive a temperature retrieval based on the clusters of brightness temperatures. The 8 simulated channels, namely, 3 MSU and 5 IR of the TIROS-N satellite are used by the GLAS temperature retrieval method. The 3 MSU and 5 IR brightness temperatures were clustered into 17 cluster groups and a regression for the prediction of the tropopause height in mb was generated. The overall r.m.s. for the tropopause prediction is excellent, namely, around 16 mb for the summer and 23 mb for the winter. The correct cluster of brightness temperatures can be identified 98% of the time by the method of discriminatory classification if it is approximately a normal distribution or, in general, by the method of the nearest neighbor.

Munteanu, M. J.↗

Investigation of the effects of pressure gradient, temperature and wall temperature ratio on the stagnation point heat transfer for circular cylinders and gas turbine vanes

Low and high pressure shock tubes were designed and constructed for the purpose of obtaining heat transfer data over a temperature range of 390 to 2500 K, pressures of 0.3 to 42 atm, and Mach numbers of 0.15 to 1.5 with and without pressure gradient. A square test section with adjustable top and bottom walls was constructed to produce the favorable and adverse pressure gradient over the flat plate with heat gages. A water cooled gas turbine nozzle cascade which is attached to the high pressure shock tube was obtained to measuse the heat flux over pressure and suction surfaces. Thin-film platinum heat gages with a response time of a few microseconds were developed and used to measure the heat flux for laminar, transition, and turbulent boundary layers. The laminar boundary heat flux on the shock tube wall agreed with Mirel's flat plate theory. Stagnation point heat transfer for circular cylinders at low temperature compared with the theoretical prediction, but for a gas temperature of 922 K the heat fluxes were higher than the predicted values. Preliminary flat plate heat transfer data were measured for laminar, transition, and turbulent boundary layers with and without pressure gradients for free-stream temperatures of 350 to 2575 K and flow Mach numbers of 0.11 to 1.9. The experimental heat flux data were correlated with the laminar and turbulent theories and the agreement was good at low temperatures which was not the case for higher temperatures.

Nagamatsu, H. T.↗

A comparison of Arctic lower stratospheric winter temperatures for 1988-89 with temperatures since 1964

Lower stratospheric temperatures during the Airborne Arctic Stratospheric Expedition are compared with temperatures available since January, 1964. January, 1989, was the coldest averaged January in the last 26 years at high latitude, lower stratospheric levels. There have been other months with temperatures almost as low as the level of January, 1989, and localized temperatures (e.g., minimum polar vortex temperatures) have been lower than that encountered in January 1989. February, 1989, was warmer than average and March, 1989, had some of the highest polar vortex temperatures in the last 26 years. Conditions were therefore not very favorable for Polar Stratospheric Cloud (PSC) formation into early spring.

Nagatani, Ronald M.↗

A method of computing the transient temperature of thick walls from arbitrary variation of adiabatic-wall temperature and heat-transfer coefficient

A method of calculating the temperature of thick walls has been developed in which the time series and the response to a unit triangle variation of surface temperature concepts are used, together with essentially standard formulas for transient temperature and heat flow into thick walls. The method can be used without knowledge of the mathematical tools of its development. The method is particularly suitable for determining the wall temperature in one-dimensional thermal problems in aeronautics where there is a continuous variation of the heat-transfer coefficient and adiabatic-wall temperature. The method also offers a convenient means for solving the inverse problem of determining the heat-flow history when temperature history is known.

Hill, P R↗

Surface temperatures in the polar regions from Nimbus 7 temperature humidity infrared radiometer

Monthly surface temperatures in the Arctic and Antarctic regions have been derived from the 11.5 micrometer thermal infrared channel of the Nimbus 7 temperature humidity infrared radiometer (THIR) for a whole year in 1979 and for a winter and a summer month from 1980 through 1985. The data set shows interannual variability and provides spatial details that allow identification of temperature patterns over sea ice and ice sheet surfaces. For example, the coldest spot in the southern hemisphere is observed to be consistently in the Antarctic plateau in the southern hemisphere, while that in the northern hemisphere is usually located in Greenland, or one of three other general areas: Siberia, the central Arctic, or the Canadian Archipelago. Also, in the southern hemisphere, the amplitude of the seasonal fluctuation of ice sheet temperatures is about 3 times that of sea ice, while in the northern hemisphere, the corresponding fluctuations for the two surfaces are about the same. The main sources of error in the retrieval are cloud and other atmospheric effects. These were minimized by first choosing the highest radiance value from the set of measurements during the day taken within a 30 km by 30 km grid of each daily map. Then the difference of daily maps was taken and where the difference is greater than a certain threshold (which in this case is 12 C), the data element is deleted. Overall, the monthly maps derived from the resulting daily maps are spatially and temporally consistent, are coherent with the topograph y of the Antarctic continent and the location of the sea ice edge, and are in qualitative agreement with climatological data. Quantitatively, THIR data are in good agreement with Antarctic ice sheet surface air temperature station data with a correlation coefficient of 0.997 and a standard deviation of 2.0 C. The absolute values are not as good over the sea ice edges, but a comparison with Russian 2-m drift station temperatures shows very high correlation (with correlation coefficient at 0.998) and a standard deviation of 1.1 C. Overall, the rms error is estimated to be from 1 to 2 C, depending on the surface, while the average bias when compared with in situ data is less than 2 C.

Comiso, Josefino C.↗

Estimating the urban bias of surface shelter temperatures using upper-air and satellite data. Part 1: Development of models predicting surface shelter temperatures

Multiple regression techniques were used to predict surface shelter temperatures based on the time period 1986-89 using upper-air data from the European Centre for Medium-Range Weather Forecasts (ECMWF) to represent the background climate and site-specific data to represent the local landscape. Global monthly mean temperature models were developed using data from over 5000 stations available in the Global Historical Climate Network (GHCN). Monthly maximum, mean, and minimum temperature models for the United States were also developed using data from over 1000 stations available in the U.S. Cooperative (COOP) Network and comparative monthly mean temperature models were developed using over 1150 U.S. stations in the GHCN. Three-, six-, and full-variable models were developed for comparative purposes. Inferences about the variables selected for the various models were easier for the GHCN models, which displayed month-to-month consistency in which variables were selected, than for the COOP models, which were assigned a different list of variables for nearly every month. These and other results suggest that global calibration is preferred because data from the global spectrum of physical processes that control surface temperatures are incorporated in a global model. All of the models that were developed in this study validated relatively well, especially the global models. Recalibration of the models with validation data resulted in only slightly poorer regression statistics, indicating that the calibration list of variables was valid. Predictions using data from the validation dataset in the calibrated equation were better for the GHCN models, and the globally calibrated GHCN models generally provided better U.S. predictions than the U.S.-calibrated COOP models. Overall, the GHCN and COOP models explained approximately 64%-95% of the total variance of surface shelter temperatures, depending on the month and the number of model variables. In addition, root-mean-square errors (rmse's) were over 3 C for GHCN models and over 2 C for COOP models for winter months, and near 2 C for GHCN models and near 1.5 C for COOP models for summer months.

Epperson, David L.↗

Effect of Temperature Cycling and Exposure to Extreme Temperatures on Reliability of Solid Tantalum Capacitors

In this work, results of multiple temperature cycling (TC) (up to 1,000 cycles) of different types of solid tantalum capacitors are analyzed and reported. Deformation of chip tantalum during temperature variations simulating reflow soldering conditions was measured to evaluate the possibility of the pop-corning effect in the parts. To simulate the effect of short-time exposures to solder reflow temperatures on the reliability of tantalum capacitors, several part types were subjected to multiple cycles (up to 100) between room temperature and 240 C with periodical measurements of electrical characteristics of the parts. Mechanisms of degradation caused by temperature cycling and exposure to high temperatures, and the requirements of MIL-PRF-55365 for assessment of the resistance of the parts to soldering heat are discussed.

Teverovsky, Alexander↗

Raman Channel Temperature Measurement of SiC MESFET as a Function of Ambient Temperature and DC Power

Raman spectroscopy is used to measure the junction temperature of a Cree SiC MESFET as a function of the ambient temperature and DC power. The carrier temperature, which is approximately equal to the ambient temperature, is varied from 25 C to 450 C, and the transistor is biased with VDS=10V and IDS of 50 mA and 100 mA. It is shown that the junction temperature is approximately 52 and 100 C higher than the ambient temperature for the DC power of 500 and 1000 mW, respectively.

Ponchak, George E.↗

Temperature Dependence of Thin Film Spiral Inductors on Alumina Over a Temperature Range of 25 to 475 C

In this paper, we present an analysis of inductors on an Alumina substrate over the temperature range of 25 to 475 C. Five sets of inductors, each set consisting of a 1.5, 2.5, 3.5, and a 4.5 turn inductor with different line width and spacing, were measured on a high temperature probe station from 10 MHz to 30 GHz. From these measured characteristics, it is shown that the inductance is nearly independent of temperature for low frequencies compared to the self resonant frequency, the parasitic capacitances are independent of temperature, and the resistance varies nearly linearly with temperature. These characteristics result in the self resonant frequency decreasing by only a few percent as the temperature is increased from 25 to 475 C, but the maximum quality factor decreases by a factor of 2 to 3. These observations based on measured data are confirmed through 2D simulations using Sonnet software.