Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “temperature target”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Optical experiments on thermophoretically augmented submicron particle deposition from 'dusty' high temperature gas flows

A real-time laser reflectivity method and Pt ribbon targets are used to obtain experimental data on the initial deposition rate of MgO(s) particles of approximately 700 nm diameter from otherwise clean combustion products as a function of target temperature (about 950-1450 K) and mainstream gas temperature (about 1500-1600 K). These preliminary data are used to demonstrate the dominant role of thermophoresis (particle drift down a temperature gradient) and to assess the utility of recently developed theoretical methods for predicting and correlating the temperature dependence of thermophoretically augmented convective-diffusion 'dust' deposition rates from flowing hot gases.

Rosner, Daniel E.↗

Fragmentation of ice by low velocity impact

Low-velocity impact experiments (0.14 to 1 km/s) carried out in polycrystalline water ice targets at 257 and 81 K reveal interactions which are assigned to four fragmentation classes: cratering, erosion, disruption, and total fragmentation. The specific kinetic energies for the transitions between these classes are found to be about one to two orders of magnitude below those for silicate rocks. The mass vs. cumulative number distribution of fragments in the experiments is described by a simple power law, similar to that observed in fragmented rocks both in the laboratory and in nature. The logarithmic slopes of cumulative number vs. fragment weight range from -0.9 to -1.8; they decrease with increasing projectile energy and are approximately independent of target temperature. The shapes of fragments resulting from erosion and disruption of ice targets are found to be significantly less spherical for 257 K targets than for 81 K targets. Fragment sphericity increases with increasing projectile energy at 257 K; however, no similar trend is observed for 81 K ice.

Lange, M. A.↗

Extended temperature range studies for dry heat microbial reduction

This paper will present the lethality data that has been collected at this time and the planned future studies. The results show that rapid ramp-up heating times are critical to obtaining valid lethality data at high temperatures because an extensive number of spores are killed before reaching the target temperature. Exploratory experiments have also been performed using a laser to rapidly heat coupons.

microbial reduction↗

Overview of STEREO/EUVI and SOHO/EIT Data during the WHI Campaign

The poster will present an overview of the data from the March-April,2008 Whole Heliospheric Interval Campaign. These instruments will show the targets during the campaign from three points of view at a range of temperatures. Targets are expected to include coronal cavities, coronal holes, active regions and prominences.

Kucera, Therese A.↗

Thermal Modelling of the in-Situ Consolidation of Automated Fiber Placement of Thermoplastic Composites

NASA is developing carbon fiber reinforced thermoplastic composites processing methods under the Hi-rate Composites Aircraft Manufacturing (HiCAM) project. The in-situ consolidation automated fiber placement (AFP) of thermoplastics (ICAT) process has high potential to increase manufacturing throughput and lower costs as it combines the repeatability and fast lay down rates of AFP with the thermoformability of thermoplastic materials to achieve part consolidation out of the autoclave. Physics-based process models are employed in the ICAT process development to understand, fundamentally, the thermal response of the carbon fiber (CF)/polyaryletherketone (PAEK) material during the rapid heating and cooling associated with laser-assisted AFP. A one-dimensional (1-D) closed-form model was developed capable of predicting the temperature profile through-the-thickness of the tape material. In addition, a two-dimensional (2-D) model was developed to predict the heat transfer through-the-thickness and in the laydown x-direction of the AFP head motion. The solution of the Fourier heat-transfer equations in the 2-D model is approximated using the explicit finite difference numerical method. The temperature profile during placement of PAEK slit-tape materials at various laser target temperatures and placement speeds were measured during ICAT process development trials at Electroimpact®, Inc. †† and the resulting experimental data is compared with the predictions of the 1-D and 2-D models.

Thermoplastics↗

Thermal Modelling of the In-Situ Consolidation of Automated Fiber Placement Of Thermoplastic Composites

NASA is developing carbon fiber reinforced thermoplastic composites processing methods under the Hi-rate Composites Aircraft Manufacturing (HiCAM) project. The in-situ consolidation automated fiber placement (AFP) of thermoplastics (ICAT) process has high potential to increase manufacturing throughput and lower costs as it combines the repeatability and fast lay down rates of AFP with the thermoformability of thermoplastic materials to achieve part consolidation out of the autoclave. Physics-based process models are employed in the ICAT process development to understand, fundamentally, the thermal response of the carbon fiber (CF)/polyaryletherketone (PAEK) material during the rapid heating and cooling associated with laser-assisted AFP. A one-dimensional (1-D) closed-form model was developed capable of predicting the temperature profile through-the-thickness of the tape material. In addition, a two-dimensional (2-D) model was developed to predict the heat transfer through-the-thickness and in the laydown x-direction of the AFP head motion. The solution of the Fourier heat-transfer equations in the 2-D model is approximated using the explicit finite difference numerical method. The temperature profile during placement of PAEK slit-tape materials at various laser target temperatures and placement speeds were measured during ICAT process development trials at Electroimpact®, Inc. †† and the resulting experimental data is compared with the predictions of the 1-D and 2-D models.

Christopher J. Stelter↗

S193 radiometer brightness temperature precision/accuracy for SL2 and SL3

The precision and accuracy with which the S193 radiometer measured the brightness temperature of ground scenes is investigated. Estimates were derived from data collected during Skylab missions. Homogeneous ground sites were selected and S193 radiometer brightness temperature data analyzed. The precision was expressed as the standard deviation of the radiometer acquired brightness temperature. Precision was determined to be 2.40 K or better depending on mode and target temperature.

Pounds, D. J.↗

Going Places No Infrared Temperature Devices Have Gone Before

Exergen's IRt/c is a self-powered sensor that matches a thermocouple within specified temperature ranges and provides a predictable and repeatable signal outside of this specified range. Possessing an extremely fast time constant, the infrared technology allows users to measure product temperature without touching the product. The IRt/c uses a device called a thermopile to measure temperature and generate current. Traditionally, these devices are not available in a size that would be compatible with the Exergen IRt/c, based on NASA s quarterinch specifications. After going through five circuit designs to find a thermopile that would suit the IRt/c design and match the signal needed for output, Exergen maintains that it developed a model that totaled just 20 percent of the volume of the previous smallest detector in the world. Following completion of the project with Glenn, Exergen continued development of the IRt/c for other customers, spinning off a new product line called the micro IRt/c. This latest development has broadened applications for industries that previously could not use infrared thermometers due to size constraints. The first commercial use of the micro IRt/c involved an original equipment manufacturer that makes laminating machinery consisting of heated rollers in very tight spots. Accurate temperature measurement for this application requires close proximity to the heated rollers. With the micro IRt/c s 50-millisecond time constant, the manufacturer is able to gain closer access to the intended temperature targets for exact readings, thereby increasing productivity and staying ahead of competition.In a separate application, the infrared temperature sensor is being utilized for avalanche warnings in Switzerland. The IRt/c is mounted about 5 meters above the ground to measure the snow cover throughout the mountainous regions of the country.

Source record↗

Influence of the preshock temperature on shock effects in quartz

Shock metamorphic features are the prime indicators for recognizing impact phenomena on Earth and other planetary bodies. Although the pressure dependence of shock features is well known, information about the influence of the preshock temperature is almost lacking. Especially in the case of large-scale impacts like Sudbury, it is expected that deep-seated crustal rocks were subjected to shock at elevated temperatures. Therefore, we continued to perform shock experiments at elevated temperatures on less than 0.5-mm thin disks of single crystal quartz cut parallel to the (1010) face. All recovered quartz samples were investigated by universal stage, spindle stage, and a newly developed density gradient technique. Errors of refractive index and density measurements are +/- 0.0005 and +/- 0.002 g/cu cm respectively. Our investigations indicate that shock metamorphic features are strongly dependent on the preshock temperature. This statement has far-reaching implications with respect to shock wave barometry that is based on data from recovery experiments at room temperature. These datasets might be applicable only to low-temperature target rocks. Moreover, this study demonstrates that shock recovery experiments are definitely required for understanding the complete pressure-temperature regime of shock metamorphism on planetary bodies.

Langenhorst, F.↗

Absorption heat pump for space applications

In the first part, the performance of the Absorption Heat Pump (AHP) with water-sulfuric acid and water-magnesium chloride as two new refrigerant-absorbent fluid pairs was investigated. A model was proposed for the analysis of the new working pairs in a heat pump system, subject to different temperature lifts. Computer codes were developed to calculate the Coefficient of Performance (COP) of the system with the thermodynamic properties of the working fluids obtained from the literature. The study shows the potential of water-sulfuric acid as a satisfactory replacement for water-lithium bromide in the targeted temperature range. The performance of the AHP using water-magnesium chloride as refrigerant-absorbent pair does not compare well with those obtained using water-lithium bromide. The second part concentrated on the design and testing of a simple ElectroHydrodynamic (EHD) Pump. A theoretical design model based on continuum electromechanics was analyzed to predict the performance characteristics of the EHD pump to circulate the fluid in the absorption heat pump. A numerical method of solving the governing equations was established to predict the velocity profile, pressure - flow rate relationship and efficiency of the pump. The predicted operational characteristics of the EHD pump is comparable to that of turbomachinery hardware; however, the overall efficiency of the electromagnetic pump is much lower. An experimental investigation to verify the numerical results was conducted. The pressure - flow rate performance characteristics and overall efficiency of the pump obtained experimentally agree well with the theoretical model.

Nguyen, Tuan↗

Development of a solar powered residential air conditioner (General optimization)

A commercially available 3-ton residential Lithium Bromide (LiBr) absorption air conditioner was modified for use with lower temperature solar heated water. The modification included removal of components such as the generator, concentration control chamber, liquid trap, and separator; and the addition of a Chrysler designed generator, an off-the-shelf LiBr-solution pump. The design goal of the modified unit was to operate with water as the heat-transfer fluid at a target temperature of 85 C (185 F), 29.4 C (85 F) cooling water inlet, producing 10.5 kW (3 tons) of cooling. Tests were performed on the system before and after modification to provide comparative data. At elevated temperatures (96 C, 205 F), the test results show that Lithium Bromide was carried into the condenser due to the extremely violent boiling and degraded the evaporator performance.

Lowen, D. J.↗

Calibration of the advanced microwave sounding unit-A for NOAA-K

The thermal-vacuum chamber calibration data from the Advanced Microwave Sounding Unit-A (AMSU-A) for NOAA-K, which will be launched in 1996, were analyzed to evaluate the instrument performance, including calibration accuracy, nonlinearity, and temperature sensitivity. The AMSU-A on NOAA-K consists of AMSU-A2 Protoflight Model and AMSU-A1 Flight Model 1. The results show that both models meet the instrument specifications, except the AMSU-A1 antenna beamwidths, which exceed the requirement of 3.3 +/- 10%. We also studied the instrument's radiometric characterizations which will be incorporated into the operational calibration algorithm for processing the in-orbit AMSU-A data from space. Particularly, the nonlinearity parameters which will be used for correcting the nonlinear contributions from an imperfect square-law detector were determined from this data analysis. It was found that the calibration accuracies (differences between the measured scene radiances and those calculated from a linear two-point calibration formula) are polarization-dependent. Channels with vertical polarizations show little cold biases at the lowest scene target temperature 84K, while those with horizontal polarizations all have appreciable cold biases, which can be up to 0.6K. It is unknown where these polarization-dependent cold biases originate, but it is suspected that some chamber contamination of hot radiances leaked into the cold scene target area. Further investigation in this matter is required. The existence and magnitude of nonlinearity in each channel were established and a quadratic formula for modeling these nonlinear contributions was developed. The model was characterized by a single parameter u, values of which were obtained for each channel via least-squares fit to the data. Using the best-fit u values, we performed a series of simulations of the quadratic corrections which would be expected from the space data after the launch of AMSU-A on NOAA-K. In these simulations, the cosmic background radiance corresponding to a cold space temperature 2.73K was adopted as one of the two reference points of calibration. The largest simulated nonlinear correction is about 0.3K, which occurs at channel 15 when the instrument temperature is at 38.09 deg C. Others are less than 0.2K in the remaining channels. Possible improvement for future instrument calibration is also discussed.

Mo, Tsan↗

Comparisons of Cloud In-Situ Microphysical Properties of Deep Convective Clouds to Appendix D/P, Using Data from the HAIC-HIWC and HIWC RADAR I Flight Campaigns

In-situ cloud data from three international flight campaigns is compared to the new Federal Aviation Administration (FAA) Title 14 Code of Federal Regulations Part 33 Appendix D mixed-phase/glaciated environmental envelope (1), and the corresponding identical European Aviation Safety Agency (EASA) CS-25 Appendix P envelope (2) (hereafter "Appendix D/P"). Appendix D/P consists of a temperature-altitude envelope, a 99th percentile total water content (TWC99) envelope at the 17.4 Nm distance scale, a distance factor to estimate TWC99 values at other distance scales, ice crystal median mass diameter (MMD), and recommended liquid water content (LWC) levels in mixed-phase icing conditions. The dataset is from 45 flight missions in 3 tropical locations, with 472 runs in approximately 115 clouds, providing about 29,600 Nm of in-cloud data in deep convection over four targeted temperature intervals: 10, 30, 40, and 50 +5 C. The measurements span altitueds from about 17,000' to 39,000'. The comparisons will serve as a basis for regulatory and industry assessment of the efficacy of Appendix D/P.

Strapp, J. Walter↗

X ray based displacement measurement for hostile environments

A new method on noncontacting, high temperature extensometry based on the focus and scanning of x rays is currently under development and shows great promise of overcoming limitations associated with available techniques. The chief advantage is the ability to make undisturbed measurements through stratified or flowing gases, smoke, and flame. The system is based on the ability to focus and scan low energy, hard x rays such as those emanating from copper or molybdenum sources. The x rays are focused into a narrow and intense line image which can be scanned onto targets that fluoresce secondary x ray radiation. The final goal of the system is the ability to conduct macroscopic strain measurements in hostile environments by utilizing two or more fluorescing targets. Current work is limited to displacement measurement of a single target with a resolution of 1.25 micro-m and a target temperature of 1200 C, directly through an open flame. The main advantage of the technique lies in the penetrating nature of x rays which are not affected by the presence of refracting gas layers, smoke, flame, or intense thermal radiation, all of which could render conventional extensometry methods inoperative or greatly compromise their performance.

Canistraro, Howard A.↗

Comparisons of Cloud In-Situ Microphysical Properties of Deep Convective Clouds to Appendix D/P using Data from the HAIC-HIWC and HIWC-RADAR I Flight Campaigns

In-situ cloud data from three international flight campaigns are compared to the Federal Aviation Administration Title 14 Code of Federal Regulations Part 33 Appendix D mixed-phase/glaciated environmental envelope, and the corresponding identical European Aviation Safety Agency CS-25 Appendix P envelope. The appendices consist of a temperature-altitude envelope, a 99th percentile total water content envelope at the 17.4 Nm distance scale, a distance factor for estimation at other distance scales, ice crystal median mass diameter, and recommended liquid water content levels in mixed-phase icing conditions. The data were collected during 54 flights out of one subtropical and two tropical locations, with 472 runs from about 17,000’ to 39,000’ in approximately 115 clouds. The campaigns provide about 29,600 Nm of in situ data in deep convection over four targeted temperature intervals: -10, -30, -40, and -50, all ± 5 C. The dataset is a modern and unique documentation of the ice crystal icing environment, and results described in this article will contribute to regulatory and industry assessment of Appendices D and P.

Ice Crystal Icing↗

X-ray-based displacement measurement for hostile environments

A new method on noncontacting, high temperature extensometry based on the focus and scanning of X-rays is currently under development and shows great promise of overcoming limitations associated with available techniques. The chief advantage is the ability to make undisturbed measurements through stratified or flowing gases, smoke, and flame. The system is based on the ability to focus and scan low energy, hard X-rays such as those emanating from copper or molybdenum sources. The X-rays are focused into a narrow and intense line image which can be scanned onto targets that fluoresce secondary X-ray radiation. The final goal of the system is the ability to conduct macroscopic strain measurements in hostile environments by utilizing two or more fluorescing targets. Current work is limited to displacement measurement of a single target with a resolution of 1.25 micro-m and a target temperature of 1200 C, directly through an open flame. The main advantage of the technique lies in the penetrating nature of X-rays which are not affected by the presence of refracting gas layers, smoke, flame, or intense thermal radiation, all of which could render conventional extensometry methods inoperative or greatly compromise their performance.

Canistraro, H. A.↗

Inverse Compton Cooling in the Coronae of Simulated Black Hole Accretion Flows

We present a formulation for a local cooling function to be employed in the diffuse, hot corona region of 3D GRMHD simulations of accreting black holes. This new cooling function calculates the cooling rate due to inverse Compton scattering by considering the relevant microphysics in each cell in the corona and approximating the radiation energy density and Compton temperature there by integrating over the thermal seed photon flux from the disk surface. The method either assumes ion and electron tem- peratures are equal (1T), or calculates them separately (2T) using an instantaneous equilibrium approach predicated on the actual relevant rate equations (Coulomb and Compton). The method is shown to be consistent with a more detailed ray-tracing calculation where the bulk of the cooling occurs, but is substantially less costly to per- form. As an example, we apply these methods to a harm3d simulation of a 10M⊙, non-spinning black hole, accreting at nominally 1% the Eddington value. Both 1T and 2T approaches lead to increased radiative efficiency and a larger fraction of total cooling in the corona as compared to the original target-temperature cooling function used by harm3d, especially in the 1T case. Time-averaged post-processing reveals that the continuum spectral observations predicted from these simulations are qualitatively similar to actual X-ray binary data, especially so for the 1T approach which yields a harder power-law component (Γ = 2.25) compared to the 2T version (Γ = 2.53).

Brooks E. Kinch↗

Spacelab qualified infrared imager for microgravity science applications

The Lewis Research Center is developing, under contract, a Spacelab (manned module in the Space Shuttle payload bay) qualified infrared imager for noncontact surface temperature measurement in the Surface Tension Driven Convection Experiment, a microgravity fluid physics experiment. A versatile design philosophy was used in order to provide other experiments with essentially an off the shelf Shuttle qualified instrument, eliminating the duplication of the rigorous development and flight qualification processes. An Inframetrics Model 600 Scanning Infrared Radiometer is being modified to satisfy both experimental and flight requirements, while maintaining the basic performance parameters of the commercial instrument. The modifications include an efficient, low power closed cycle cryogenic cooler to cool the detector, a ruggedized scanner mechanism, 8 bit A/D conversion, Mil-STD components (where possible), size and weight optimization, and the addition of a microprocessor to perform automatic gain control. Features such as detector spectral response, the addition of spectral filters, and target temperature ranges could easily be changed to make this instrument useful as both a qualitative and quantitative diagnostic tool for Spacelab microgravity experiments, in combustion and fluid physics.

Pline, Alexander D.↗