Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “temperature distribution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Distributed optical fibre sensing in physical oceanography: emergence and future prospects

Distributed optical fibre sensing (DOFS) is a technology that enables continuous, real-time measurements of a range of environmental parameters along the length of a fibre optic cable. In this article, we review the recently emerged applications of DOFS techniques in physical oceanography and offer a perspective on the technology's potential for future growth within the field. The introduction of DOFS to physical oceanography is contextualised with a brief history of the technology, which spun off primarily from the use of seafloor-laid optical fibres for telecommunications purposes. The key components and underpinning physics of a DOFS system are outlined and, on their basis, the suite of variables that are observable with DOFS are discussed. The implementation factors of DOFS, which include trade-offs between measurement accuracy and spatio-temporal resolutions and ranges, are also examined. The physical oceanographic applications of DOFS to date are then illustrated with case examples of four distinct DOFS techniques: distributed temperature sensing (DTS), which can provide ocean temperature observations; distributed static strain sensing (DSS) and distributed acoustic sensing (DAS), which are sensitive to temperature, cable strain and strain-associated variables, such as pressure and ocean velocity; and ultra-long-range observations of ocean currents with optical interferometry. The forthcoming prospects of DOFS in physical oceanography are considered, and are proposed to include new fibre optic-based approaches to sense ocean salinity and measure through the water column. We conclude with reflections on the future role of DOFS within the Global Ocean Observing System, and highlight the opportunities provided by the existing world-wide network of seafloor-laid optical fibres.

Naveira Garabato, Alberto C. [Univ. of Southampton↗

Prototype Modeling for a Light-Trapping Planar-Cavity Enclosed Particle Solar Receiver

Concentrating solar thermal (CST) systems present a promising avenue for affordable and reliable energy production. Solar receivers are key components that determine the efficiency and longevity of these systems. Particle-based solar receivers have emerged as a compelling alternative to traditional technologies, offering several advantages that address limitations in current CST systems. This is especially true as next-generation CST technologies target applications including electricity generation, thermochemical processes, and industrial process heat, many of which necessitate higher operating temperatures than current commercial molten salt systems. Molten-salt thermal energy storage (TES) systems, commonly used in CSP, face challenges related to freezing and corrosion. Particle-based TES systems, in contrast, do not experience these issues, as particles are stable at high temperatures, exceeding 1000 degrees Celsius. This capability allows for a wider range of applications, including those requiring higher temperatures for industrial processes and efficient electricity generation. A novel innovation in particle-based solar receiver technology is the light-trapping planar cavity receiver (LTPCR) configuration developed by NREL. The LTPCR design consists of small cavity-like structures using opaque planar surfaces, enabling efficient capture and absorption of solar energy. A high incident flux concentration at the cavity aperture is absorbed on the receiver walls, and subsequently transferred to particles on the inside of cavities. The particles flow through the system, forming a fluidized bed inside of the receiver panels, effectively capturing the absorbed solar heat. Air is used as a fluidizing medium in this process to enhance particle heat transfer and mixing. The effectiveness of this design lies in its ability to manage solar flux conditions and ensure high solar-to-thermal receiver efficiency. A 100-kW prototype is currently being tested at the King Saud University in Saudi Arabia to assess the receiver performance. A range of modeling analyses for the optical, thermal, and mechanical effects were conducted to assess the performance of the receiver under on-sun conditions. The solar flux resulting from the KSU heliostat field was modeled using NREL SolTrace software and produced up to 600 kW/m2 at the receiver aperture. The solar flux absorbed on the receiver walls was then used within a computational fluid dynamics (CFD) model to predict wall temperature distributions along with radiation and convection loss. A two-phase CFD model was developed for the fluidized bed of silica sand inside the receiver panels to predict local wall-to-particle heat transfer coefficients, particle temperature distributions, and outlet temperature of the particles. We have also conducted analyses to understand the thermomechanical behavior of these innovative enclosed light-trapping solar receivers optimized for particle heating. We used finite element analysis (FEA) to predict the receiver's performance using temperature distributions obtained from CFD and based on the resulting stress profiles, evaluated creep-fatigue damage with a goal of achieving a 30-year service life. Analysis showed a significant impact of the particle-to-wall heat transfer coefficients (HTCs) on receiver performance, with higher HTCs resulting in reduced stress and increased lifespan. For instance, when using Inconel 740H, increasing the HTC from 800 W/m2 K to 1400 W/m2 K increased the creep life from 4,000 hours to over 100,000 hours. This highlights the importance of understanding and optimizing heat transfer in the design of high-efficiency receivers.

14 SOLAR ENERGY↗

CFD modeling of natural circulation in LiCl-KCl molten salt closed loop

Characterizing flow within a molten salt closed-loop system is crucial for assessing system requirements, evaluating performance, and identifying potential flaws. Direct flow measurement using instrumentation is challenging due to extreme environmental conditions and the limitations associated with measuring molten salt flow under natural convection. Here, this study aims to provide comprehensive insights into the thermal-hydraulic behavior of a closed loop, with a particular focus on temperature distribution and velocity prediction. The Computational Fluid Dynamics (CFD) model demonstrated the capability to effectively simulate and predict both temperature distributions and flow velocities within the molten salt loop. The CFD model's predictive capability was validated by its ability to replicate temperature measurements under varying boundary conditions. The analysis revealed that the CFD model tends to underpredict temperatures in the cold leg and overpredict them in the hot leg, highlighting the need for continuous model refinement and acknowledging the limitations of using a steady-state approach. Furthermore, the potential of using external temperature measurements to estimate internal molten salt temperatures and predict flow velocity was explored, revealing that this approach could introduce up to a 5.5% error in flow velocity calculations. Line probes mapping temperature distributions across the tube's cross-section and molten salt provided valuable insights into temperature gradients, emphasizing the need for a thermal conductivity equation for molten salt with lower uncertainty to achieve more accurate temperature predictions of the system.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Deep Neural Network Assisted Distributed Strain and Temperature Fiber Sensor System for Natural Gas Pipeline Monitoring

Natural gas pipeline integrity monitoring is crucial to detect potential leaks, find structural issues, and prevent environmental damage. This article presents a system of natural gas pipeline monitoring that uses a specialized double Brillouin peak sensing fiber along with the Brillouin optical time domain analysis (BOTDAs) technique. The calibrated sensing fiber coefficients for strain and temperature are 41.8 kHz/ με and 0.9 MHz/°C for peak 1; and 47.2 kHz/ με , and 1.11 MHz/°C for peak 2, respectively. Initially, lab tests were performed by installing a short section of double Brillouin peak fiber (DBPF) on a 1-in steel pipe under pressure up to 1000 per square inch (psi) at elevated temperatures. Simultaneous distributed measurements of temperature and pressure-induced hoop strain were successfully measured. Considering the long processing speed to extract Brillouin frequency shift (BFS), we employ a novel probabilistic deep neural network (PDNN) framework for rapid BFS prediction. Additionally, using the Finite Element Method, the effects of the pipeline pressure on hoop strain were modeled and compared to the experimental hoop strain under the same set of pipeline conditions. Finally, an actual 4-in outer diameter steel natural gas pipeline was used for pilot-scale tests, where hoop strain was measured at various pressure levels. Leaks were simulated to demonstrate accurate pipeline integrity monitoring. At an internal pipe pressure of 1000 psi, hoop strain of approximately 300 με was observed, and the sensitivity was calculated as 0.28 με /psi. The results of this pilot-scale study demonstrated that the system is capable of performing distributed monitoring sufficient to detect pipeline pressure and the presence of leaks to ensure the safe operation of gas pipelines in the field.

03 NATURAL GAS↗

Effects of temperature inversion on densification in chemical vapor infiltration

In a classical chemical vapor infiltration (CVI) process, the competing effects of chemical kinetics and reagent gas transport lead to non–uniform depositions such that outer layers of a preform densify faster leaving the core highly porous. Currently, CVI must be performed at a sufficiently low temperature to achieve good densification quality which leads to high processing time and cost. Volumetric heating of the preform, especially through microwaves, can create temperature inversion such that the core is hotter than the outer surface and potentially, overcome the challenges associated with isothermal CVI. Direct numerical simulations (DNS) of densification under various such temperature distributions indicate that microwave heating in CVI processing can lead to better (uniform) densification of porous preforms. Here the role of key parameters describing the temperature distributions on the densification behavior is investigated. Strategic temporal control of the temperature distribution shows that processing times can be reduced by almost half while maintaining a good densification quality similar to that of low–temperature isothermal processing. Inside–out densification due to the inverted temperature profile is a key distinguishing characteristic of microwave assisted CVI.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thermal stress in degraded forests in the Brazilian Amazon Arc of Deforestation

Understanding thermal stress in tropical forests has taken on new urgency in light of accelerating climate change and expansion of deforestation and forest degradation. Degraded tropical forests in particular may be approaching critical temperature thresholds even more rapidly than intact forests, with implications for tree survival and ecosystem recovery. We investigate thermal stress in degraded tropical forests within the Brazilian Amazon Arc of Deforestation. Using land surface temperature data from the ECOsystem Spaceborne Thermal Radiometer Experiment on the international Space Station (ECOSTRESS), we compared canopy temperatures of intact, selectively logged, and burned forests in Feliz Natal, Mato Grosso, Brazil. Upper canopy temperatures in previously burned forests were 4.1% higher (mean = 36.5 °C) and 50.9% more variable compared to intact and logged forests, which showed remarkably similar temperature distributions (means of 34.9 °C and 35.1 °C, respectively). Modeled leaf temperature distributions based on canopy temperature measurements from one of the warmest days in a 2 year dry season record indicated that 87% of leaves in the warmest burned forest patches exceeded the temperature threshold where respiration surpasses photosynthesis, compared to approximately 72%–74% in intact and logged forests, respectively, in the same time period. After controlling for environmental factors, burned forests were predicted to be 2.6 °C warmer on average [1.39 °C–3.96 °C, 95% credible interval] than intact forests across a 5–40 m canopy height range. Burned forests showed modest thermal recovery over time, with temperatures decreasing by approximately 1.2 °C over a 30 year recovery period. In contrast, logged forests showed minimal thermal differences from intact forests (−0.353 on average, [−1.125–0.274, 95% credible interval]) and negligible change (0.15 °C) over the same timeframe. While the absolute probabilities of exceeding damaging thermal thresholds remain low across all forest types under current climate conditions, the probability of leaves exceeding temperatures that cause permanent leaf damage was ten times higher in burned forests, with implications for the future of burned forest regeneration in water-limited regions of the Amazon basin. In particular, the combination of higher mean temperatures, greater temperature variability, and more frequent exposure to damaging thermal thresholds implies that burned tropical forests will experience substantially higher mortality rates and slower biomass recovery compared to intact and selectively logged forests, especially in water-limited regions where trees cannot rely on evaporative cooling to moderate canopy temperatures.

Brazilian Amazon Arc of Deforestation↗

Thermal Performance of Neutron Sensor Qualification Device

The neutron sensor qualification device was developed to provide a temperature-controlled environment for neutron sensors and dosimetry, enabling irradiation in a neutron field at the Armed Forces Radiobiology Research Institute (AFRRI) TRIGA reactor facility. The device, constructed from low-activation and low neutron cross-section materials, features a modular tube furnace design with three independently controlled heating zones for controlling axial temperature distribution. Laboratory testing validated the device's thermal performance, including uniform temperature distribution with less than 6°C variation across the central region, a steady-state operational temperature of 350°C achieved in approximately 3 hours, and a cooling time constant of 3.5 hours. External surface temperatures remained safe for handling, with the surrounding aluminum structure remaining at ambient conditions. The results confirm the device’s suitability for neutron sensor qualification experiments, with potential for future operation at higher temperatures and further optimization of performance.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

RELAP5-3D validation studies based on the High Temperature Test facility

In the spring and summer of 2019, experiments were conducted at the High Temperature Test Facility (HTTF) that form the basis of an upcoming high-temperature gas-cooled reactor (HTGR) thermal hydraulics (T/H) benchmark. HTTF is an integral effects test facility for HTGR T/H modeling validation. This paper presents RELAP5-3D models of two of those experiments: PG-27, a pressurized conduction cooldown (PCC); and PG-29, a depressurized conduction cooldown (DCC). These models used the RELAP5-3D model of HTTF originally developed by Paul Bayless as a starting point. The sensitivity analysis and uncertainty quantification code, RAVEN was used to perform calibration studies for the steady-state portion of PG-27. Here we developed four PG-27 calibrations based on steady-state conditions. These calibrations all used an effective thermal conductivity equal to 36 % of the measured thermal conductivity, but they differed with respect to the frictional pressure drops and radial conduction models. These models all captured the trends in steady-state temperature distributions and transient temperature behavior well. All four calibrations show room for improvement in predicting the transient temperature rise. The smallest error in temperature rise during the transient was a 21 % underprediction, and the largest was a 48 % underprediction. The errors in transient temperature rise are largely a result of a mismatch in power density between the RELAP5-3D model and the experiment due to the location of active heater rods along the boundary between heat structures in the model. The best of these calibrations was applied to PG-29 to model the DCC. Once again, temperatures during the transient were underpredicted but trends in temperature were captured. The RELAP5-3D model captured trends in the data but could not reproduce measured temperatures exactly. This result is not attributed to deficiencies in the experimental data or to RELAP5–3D itself. Rather, this result likely arises due to the some of the assumptions and decisions made when the RELAP5-3D model was first developed, prior to the execution of HTTF experiments. An agreement in prediction of temperature trends but challenges reproducing HTTF temperatures within measurement uncertainty is consistent with previous analyses of HTTF in the literature. Future RELAP5-3D validation activities centered around HTTF may be able to provide greater insight into the code’s capabilities for HTGR modeling with a more finely nodalized model.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Sensor Qualification for the Development of Advanced Reactors

A temperature sensor qualification device is undergoing development and testing in order to qualify temperature sensors for advanced reactor metrology applications. This device will provide National Institute of Standards and Technology (NIST) traceable performance testing of temperature sensors while under the high radiation environments experienced while in-core. This is completed by utilizing retractable sensors which transfer the measurements from ex-core to in-core sensors. A detailed discussion of the uncertainty propagation associated with this comparative process is provided. Experimental testing of the temperature distribution occurring in the device has begun and is reported on. It is pertinent to minimize this temperature distribution to prevent variation in sensor measurements. This variation will be indistinguishable from sensor drift for in-pile applications and would result in unnecessarily conservative uncertainty bounds.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Experimental testing of additively manufactured embedded fiber optic smart devices for clean energy applications

Abstract An additively manufactured prototype smart device was created to investigate in-flow temperature distributions using embedded high-definition fiber optic sensors within a component for clean energy systems. The devices were created using Ultrasonic Additive Manufacturing to create a unique embedded pathway within a flow conditioner for the high-definition fiber optic sensors to be placed within. The fibers used allowed for temperature measurements to be taken every 0.65 mm along the fiber. The high-resolution fibers were thermally calibrated enable the 2D reconstruction of the temperature profile in the flow path of the structure. This is due to the temperature-related strain response of the material and strain measurements of the fibers. Hot airflow testing of these devices showed the ability to identify localized temperature differences in the flow. The observed strain response within the smart device had higher strain concentrations in the thicker web regions than in the thinner web regions. These higher strain regions resulted in higher uncertainties for the temperature responses. Further calibration is needed to improve the accuracy of the smart devices, specifically within the inner web structures of a flow straightening component. Further investigations of the devices within flow showed the temperature sensing to be independent of the effects of flow velocity. The devices were able to distinguish temperature differences within single and two-phase flow and showed local sensitivity to the temperature changes with the identification of hot and cold spots. The presented results showed the viability of the smart device for obtaining detailed temperature distributions using common industrial components. Eventually, the goal for these smart devices will be to withstand higher temperature and pressure environments such as those experienced in nuclear, fusion, and concentrated solar energy systems.

Donlan, Connor F. (ORCID:0000000223317882)↗

Estimation of extreme temperatures in direct solar methane pyrolysis within a porous medium

Porous media have wide application in renewable energy conversion processes, such as solar-thermal fuels production and decarbonization. Heat transport mechanisms within porous media can be highly complex, particularly under extreme conditions encountered in concentrated solar thermal reactors in which direct measurement of temperature is challenging. Here, we implement and report an inverse heat conduction model to estimate the temperature distribution throughout a porous substrate domain in a direct solar methane pyrolysis process. By solving a two-dimensional heat transfer problem and applying an inverse optimization algorithm, we estimate the quasi-steady state spatial temperature distribution in a fibrous porous carbon substrate. The results are validated indirectly by experimentally measured graphite deposition and a simplified reaction kinetic model.

finite difference method↗

Quantitative phase imaging around water vapor microbubbles under pulsed laser illumination

We measured water temperature around a self-oscillating water vapor-rich bubble using diffraction phase microscopy equipped with a pulsed laser. The water vapor-rich bubble, which causes a strong water flow around it, was generated by locally heating degassed water through the photothermal conversion properties of an FeSi2 thin film. The generation of the flow is related to the self-oscillation of the bubble at sub-MHz frequencies and the temperature distribution around it. Here, the refractive index of the surrounding water was measured using a pulsed laser with a 3.5-ns pulse duration, which guarantees a time resolution of less than 1/200 of the oscillation cycle of the bubble. The temperature distribution around the bubble was calculated from the measured refractive index.

Narihira, Kyoshiro [Kyoto University, Japan]↗

Reduction of Iron (III) Oxide in Microwaves Toward Gasification Studies

The purpose of this study is to reduce hematite (Fe2O3) using hydrogen (H2), carbon monoxide (CO), and methane (CH4) gases using microwave irradiation. Conventional temperature programmed reduction of iron phase transformation under H2, CO, and CH4 agree with the literature. Furthermore, the activation energy for the iron phase transformation in a conventional reactor was in the order of H2>CO>CH4, suggesting that CH4 was the best reductant to initiate the reduction at a much lower temperature than CO, and CO was significantly better than H2 atmosphere. Due to the uneven temperature distribution, the apparent activation energy of microwave reduction under H2 was approximately 1/4th when compared to the conventional reduction in H2. X-ray diffraction (XRD) analysis showed a mixed oxide phase in microwave reduction as opposed to the clear phase transformation in conventional studies. To combat the temperature measurement issues in microwave studies, fiber optic sensors and Forward Looking InfraRed (FLIR) sensors were used to acquire the actual temperature distribution in the catalyst bed. Therefore, a reasonably accurate activation energy estimation was achieved in the catalyst bed. Combining these with the characterization and quantification of the different iron phases in microwave reduction will provide a blueprint for future microwave-assisted gasification studies.

Aireddy, Divakar Reddy↗

Complementary Subsurface Characterization Methods to Develop a Geologic Model for the EGS Collab Experiment, Sanford Underground Research Facility

The EGS (Enhanced Geothermal Systems) Collab project was performed within the Sanford Underground Research Facility (SURF) with a goal of understanding processes and evaluation of models related to hydraulic stimulation of rock at depth. The present work deals with the development of Testbed 2 where experiments were conducted at a depth of 1.25 km and were located within a well-characterized testbed in a metamorphic, amphibolite host rock. A total of eleven boreholes varying in length between 10.6 m and 81.2 m were continuously cored to develop the testbed. In addition to the continuous coring of the amphibolite host rock, geophysical instrumentation supporting electrical resistivity tomography (ERT), microearthquake (MEQ) detection, and optical fiber providing distributed temperature sensing (DTS) and distributed acoustic sensing (DAS) were installed in the monitoring boreholes, all of which produced a comprehensive complementary suite of characterization and monitoring technologies. Pre-stimulation characterization of the groundwater conditions identified only two hydraulically significant fractures, neither of which transects the central portion of the testbed. Flow and pressure monitoring indicated low preexisting pore pressure conditions likely affected by the mine openings.

15 GEOTHERMAL ENERGY↗

Complementary Subsurface Characterization Methods to Develop a Geologic Model for the EGS Collab Experiment, Sanford Underground Research Facility

The EGS (Enhanced Geothermal Systems) Collab project was performed within the Sanford Underground Research Facility (SURF) with a goal of understanding processes and evaluation of models related to hydraulic simulation of rock at depth. The present work deals with the development of Testbed 2 where experiments were conducted at a depth of 1.25 km and were located within a well-characterized testbed in a metamorphic, amphibolite host rock. A total of eleven boreholes varying in length between 10.6 m and 81.2 m were continuously cored to develop the testbed. In addition to the continuous coring of the amphibolite host rock, geophysical instrumentation supporing electrical resisivity tomography (ERT), microearthquake (MEQ) detection, and optical fiber providing distributed temperature sensing (DTS) and distributed acoustic sensing (DAS) were installed in the monitoring boreholes, all of which produced a comprehensive complementary suite of characterization and monitoring technologies.

15 GEOTHERMAL ENERGY↗

Code Benchmark of Depressurized Conduction Cooldown Transient in the High Temperature Test Facility

This paper presents results from modeling of a depressurized conduction cooldown (DCC) transient at the High Temperature Test Facility (HTTF) as part of the OECD-NEA Thermal Hydraulics Code Validation Benchmark for High-Temperature Gas-Cooled Reactors using HTTF Data . This paper briefly describes the benchmark and the models being used. It then presents a comparison of steady state and transient results based on the Problem 2 Exercise 1A and 1B definitions. We compare block and helium temperature distributions, mass flow distribution, and energy balance in steady state. All models show comparable mass flow distributions and energy balances. The temperatures within the core and outer regions are comparable in all models too, but inner reflector temperatures can vary significantly. Despite that, we find that the models are in good agreement for the full-power steady state. In the DCC, we look at block temperature at the core midplane and RCCS water exit temperature. The INL and ANL models are found to be in excellent agreement with one another on block temperature over time, while the agreement when the KAERI and NRG models are added into consideration is good. Differences in the transient heat removal from the RCCS cause the differences in block temperature over time in these models. The CNL models show similar trends to the INL, ANL, KAERI, and NRG models, but the temperatures are high because the volumes used in calculating the average temperature include the heater rods in the CNL models only. The HUN-REN model shows results that suggest significantly lower heat removal in the RCCS which merit further investigation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗