At least 37 records · Page 2

Systematic error analysis in the absolute hydrogen gas jet polarimeter at RHIC

The Polarized Atomic Hydrogen Gas Jet Target polarimeter (HJET) is operated at the Relativistic Heavy Ion Collider (RHIC) since 2004 to measure the absolute polarization of each colliding proton beam. Polarimeter detectors and data acquisition were upgraded in 2015 to increase the solid angle, energy range, and to improve the energy and time resolution. These upgrades along with an improved beam intensity and polarization allowed us to greatly reduce the statistical and systematic errors for the proton polarization measurements in RHIC Runs 15 (E beam = 100 GeV) and 17 (255 GeV). For a typical 8 hour RHIC store, the measured proton beam average polarization was about P beam ~ 55 ± 2.0 stat ± 0.3 syst %. The elastic pp analyzing power, AN(t)~0.04, was determined with a precision of about |δA N (t)|~0.0002 in the momentum transfer squared range 0.001<-t<0.020 GeV 2 . In this paper we present a detailed systematic error analysis of the polarization measurements at HJET. Perspectives of using the HJET based absolute polarimeters in the future Electron Ion Collider (EIC) will be also discussed.

43 PARTICLE ACCELERATORS↗

Overview of oxygen opacity experiments at the National Ignition Facility and investigation of potential systematic errors

Experiments to measure oxygen opacity at stellar interior conditions have been performed at the National Ignition Facility in a Discovery Science campaign. These experiments utilize the Opacity-on-NIF platform with a sample comprised of O, Mg, and Si. The spectral data from the Opacity Spectrometer cover the 1000–2000 eV photon energy range showing bound-free continuum absorption from O and line absorption from Mg and Si. DANTE and the Gated X-ray Detector are employed to measure the sample plasma’s temperature and density, respectively. Initial data show lower transmission than expected by theoretical models, raising questions of whether potential background or data uniformity concerns could produce systematic errors in the inferred transmission. Here, we investigate three concerns thought to be important for the oxygen opacity data, including instrumental scattered background, sample self-emission non-uniformity, and backlight continuum non-uniformity. Additionally, we show the effect of a recently developed method to account for 2nd order crystal reflection. The total effect of these concerns on one experiment is found to be small compared to the observed difference between the inferred transmission and a model calculation at the inferred temperature and density. Thus, we conclude that these potential sources of systematic error cannot account for the observed difference, increasing the likelihood of a real effect due to the high temperature and density conditions. However, because this is only a single experiment, we cannot make a firm conclusion. More experiments measuring the opacity and necessary calibrations are needed to assess the reproducibility and uncertainty of this result.

79 ASTRONOMY AND ASTROPHYSICS↗

Study of systematic errors of bound-state parameters in SVZ sum rules

We study systematic errors of the ground-state parameters obtained from Shifman-Vainshtein-Zakharov sum rules, making use of the harmonic-oscillator potential model as an example. In this case, one knows the exact solution for the polarization operator, which allows one to obtain both the OPE to any order and the parameters (masses and decay constants) of the bound states. We determine the parameters of the ground state making use of the standard procedures of the method of sum rules and compare the obtained results with the known exact values. We show that, in the situation when the continuum contribution to the polarization operator is not known and is modeled by an effective continuum, the method of sum rules does not allow one to control the systematic uncertainties of the extracted ground-state parameters.

74 ATOMIC AND MOLECULAR PHYSICS↗

Systematic errors of bound-state parameters obtained with SVZ sum rules

We study systematic errors of the ground-state parameters obtained by Shifman-Vainshtein-Zakharov (SVZ) sum rules, making use of the harmonic-oscillator potential model as an example. In this case, one knows the exact solution for the polarization operator, which allows one to obtain both the OPE to any order and the parameters (masses and decay constants) of the bound states. We determine the parameters of the ground state making use of the standard procedures of the method of sum rules, and compare the obtained results with the known exact values. We show that in the situation when the continuum contribution to the polarization operator is not known and is modelled by an effective continuum, the method of sum rules does not allow to control the systematic uncertainties of the extracted ground-state parameters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Reduction of Systematic Errors in Diagnostic Receivers Through the Use of Balanced Dicke-Switching and Y-Factor Noise Calibrations

Receivers designed for diagnostic applications range from those having moderate sensitivity to those possessing large dynamic range. Digital receivers have a dynamic range which are a function of the number of bits represented by the ADC and subsequent processing. If some of this range is sacrificed for extreme sensitivity, noise power can then be used to perform two-point load calibrations. Since load temperatures can be precisely determined, the receiver can be quickly and accurately characterized; minute changes in system gain can then be detected, and systematic errors corrected. In addition, using receiver pairs in a balanced approach to measuring X+, X-, Y+, Y-, reduces systematic offset errors from non-identical system gains, and changes in system performance. This paper describes and demonstrates a balanced BPM-style diagnostic receiver, employing Dicke-switching to establish and maintain real-time system calibration. Benefits of such a receiver include wide bandwidth, solid absolute accuracy, improved position accuracy, and phase-sensitive measurements. System description, static and dynamic modelling, and measurement data are presented.

99 GENERAL AND MISCELLANEOUS↗

Towards eliminating systematic errors caused by the experimental conditions in Biochemical Methane Potential (BMP) tests

Highlights: • The evaluated factors introduce significant systematic errors (10–38%) in BMP tests. • Ambient temperature (T) has the most substantial impact (∼10%) at low altitude. • Ambient pressure (p) has the most substantial impact (∼68%) at high altitude. • Continuous monitoring of T and p is not necessary for kinetic calculations. - Abstract: The Biochemical Methane Potential (BMP) test is increasingly recognised as a tool for selecting and pricing biomass material for production of biogas. However, the results for the same substrate often differ between laboratories and much work to standardise such tests is still needed. In the current study, the effects from four environmental factors (i.e. ambient temperature and pressure, water vapour content and initial gas composition of the reactor headspace) on the degradation kinetics and the determined methane potential were evaluated with a 2{sup 4} full factorial design. Four substrates, with different biodegradation profiles, were investigated and the ambient temperature was found to be the most significant contributor to errors in the methane potential. Concerning the kinetics of the process, the environmental factors’ impact on the calculated rate constants was negligible. The impact of the environmental factors on the kinetic parameters and methane potential from performing a BMP test at different geographical locations around the world was simulated by adjusting the data according to the ambient temperature and pressure of some chosen model sites. The largest effect on the methane potential was registered from tests performed at high altitudes due to a low ambient pressure. The results from this study illustrate the importance of considering the environmental factors’ influence on volumetric gas measurement in BMP tests. This is essential to achieve trustworthy and standardised results that can be used by researchers and end users from all over the world.

09 BIOMASS FUELS↗

Statistical and systematic errors in the measurement of weak-lensing Minkowski functionals: Application to the Canada-France-Hawaii Lensing Survey

The measurement of cosmic shear using weak gravitational lensing is a challenging task that involves a number of complicated procedures. We study in detail the systematic errors in the measurement of weak-lensing Minkowski Functionals (MFs). Specifically, we focus on systematics associated with galaxy shape measurements, photometric redshift errors, and shear calibration correction. We first generate mock weak-lensing catalogs that directly incorporate the actual observational characteristics of the Canada-France-Hawaii Lensing Survey (CFHTLenS). We then perform a Fisher analysis using the large set of mock catalogs for various cosmological models. We find that the statistical error associated with the observational effects degrades the cosmological parameter constraints by a factor of a few. The Subaru Hyper Suprime-Cam (HSC) survey with a sky coverage of ∼1400 deg{sup 2} will constrain the dark energy equation of the state parameter with an error of Δw {sub 0} ∼ 0.25 by the lensing MFs alone, but biases induced by the systematics can be comparable to the 1σ error. We conclude that the lensing MFs are powerful statistics beyond the two-point statistics only if well-calibrated measurement of both the redshifts and the shapes of source galaxies is performed. Finally, we analyze the CFHTLenS data to explore the ability of the MFs to break degeneracies between a few cosmological parameters. Using a combined analysis of the MFs and the shear correlation function, we derive the matter density Ω{sub m0}=0.256±{sub 0.046}{sup 0.054}.

79 ASTRONOMY AND ASTROPHYSICS↗

Mapping systematic errors in helium abundance determinations using Markov Chain Monte Carlo

Monte Carlo techniques have been used to evaluate the statistical and systematic uncertainties in the helium abundances derived from extragalactic H II regions. The helium abundance is sensitive to several physical parameters associated with the H II region. In this work, we introduce Markov Chain Monte Carlo (MCMC) methods to efficiently explore the parameter space and determine the helium abundance, the physical parameters, and the uncertainties derived from observations of metal poor nebulae. Experiments with synthetic data show that the MCMC method is superior to previous implementations (based on flux perturbation) in that it is not affected by biases due to non-physical parameter space. The MCMC analysis allows a detailed exploration of degeneracies, and, in particular, a false minimum that occurs at large values of optical depth in the He I emission lines. We demonstrate that introducing the electron temperature derived from the [O III] emission lines as a prior, in a very conservative manner, produces negligible bias and effectively eliminates the false minima occurring at large optical depth. We perform a frequentist analysis on data from several ''high quality'' systems. Likelihood plots illustrate degeneracies, asymmetries, and limits of the determination. In agreement with previous work, we find relatively large systematic errors, limiting the precision of the primordial helium abundance for currently available spectra.

79 ASTRONOMY AND ASTROPHYSICS↗

DtaRefinery: a software tool for elimination of systematic errors from parent ion mass measurements in tandem mass spectra datasets

Hybrid two-stage mass spectrometers capable of both highly accurate mass measurement and MS/MS fragmentation have become widely available in recent years and have allowed for sig-nificantly better discrimination between true and false MS/MS pep-tide identifications by applying relatively narrow windows for maxi-mum allowable deviations for parent ion mass measurements. To fully gain the advantage of highly accurate parent ion mass meas-urements, it is important to limit systematic mass measurement errors. The DtaRefinery software tool can correct systematic errors in parent ion masses by reading a set of fragmentation spectra, searching for MS/MS peptide identifications, then fitting a model that can estimate systematic errors, and removing them. This results in a new fragmentation spectrum file with updated parent ion masses.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Volumetric apparatus for hydrogen adsorption and diffusion measurements: Sources of systematic error and impact of their experimental resolutions

The development of a volumetric apparatus (also known as a Sieverts’ apparatus) for accurate and reliable hydrogen adsorption measurement is shown. The instrument minimizes the sources of systematic errors which are mainly due to inner volume calibration, stability and uniformity of the temperatures, precise evaluation of the skeletal volume of the measured samples, and thermodynamical properties of the gas species. A series of hardware and software solutions were designed and introduced in the apparatus, which we will indicate as f-PcT, in order to deal with these aspects. The results are represented in terms of an accurate evaluation of the equilibrium and dynamical characteristics of the molecular hydrogen adsorption on two well-known porous media. The contribution of each experimental solution to the error propagation of the adsorbed moles is assessed. The developed volumetric apparatus for gas storage capacity measurements allows an accurate evaluation over a 4 order-of-magnitude pressure range (from 1 kPa to 8 MPa) and in temperatures ranging between 77 K and 470 K. The acquired results are in good agreement with the values reported in the literature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of weak lensing by NFW and Einasto halos and systematic errors

Recent N-body simulations have shown that Einasto radial profiles provide the most accurate description of dark matter halos. Predictions based on the traditional NFW functional form may fail to describe the structural properties of cosmic objects at the percent level required by precision cosmology. We computed the systematic errors expected for weak lensing analyses of clusters of galaxies if one wrongly models the lens density profile. Even though the NFW fits of observed tangential shear profiles can be excellent, viral masses and concentrations of very massive halos (∼> 10{sup 15}M{sub ⊙}/h) can be over- and underestimated by 0∼ 1 per cent, respectively. Misfitting effects also steepen the observed mass-concentration relation, as observed in multi-wavelength observations of galaxy groups and clusters. Based on shear analyses, Einasto and NFW halos can be set apart either with deep observations of exceptionally massive structures (∼> 2×10{sup 15}M{sub ⊙}/h) or by stacking the shear profiles of thousands of group-sized lenses (∼> 10{sup 14}M{sub ⊙}/h)

79 ASTRONOMY AND ASTROPHYSICS↗

Robustness of single-qubit geometric gate against systematic error

Universal single-qubit gates are constructed from a basic Bloch rotation operator realized through nonadiabatic Abelian geometric phase. The driving Hamiltonian in a generic two-level model is parameterized using controllable physical variables. The fidelity of the basic geometric rotation operator is investigated in the presence of systematic error in control parameters, such as the driving pulse area and frequency detuning. Compared to a conventional dynamic rotation, the geometric rotation shows improved fidelity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Matching post-Newtonian and numerical relativity waveforms: Systematic errors and a new phenomenological model for nonprecessing black hole binaries

We present a new phenomenological gravitational waveform model for the inspiral and coalescence of nonprecessing spinning black hole binaries. Our approach is based on a frequency-domain matching of post-Newtonian inspiral waveforms with numerical relativity based binary black hole coalescence waveforms. We quantify the various possible sources of systematic errors that arise in matching post-Newtonian and numerical relativity waveforms, and we use a matching criteria based on minimizing these errors; we find that the dominant source of errors are those in the post-Newtonian waveforms near the merger. An analytical formula for the dominant mode of the gravitational radiation of nonprecessing black hole binaries is presented that captures the phenomenology of the hybrid waveforms. Its implementation in the current searches for gravitational waves should allow cross-checks of other inspiral-merger-ringdown waveform families and improve the reach of gravitational-wave searches.

79 ASTRONOMY AND ASTROPHYSICS↗

Sources of the systematic errors in measurements of {sup 214}Po decay half-life time variations at the Baksan deep underground experiments

The design changes of the Baksan low-background TAU-1 and TAU-2 set-ups allowed to improve a sensitivity of {sup 214}Po half-life (τ) measurements up to the 2.5 × 10{sup −4} are described. Different possible sources of systematic errors influencing on the τ-value are studied. An annual variation of {sup 214}Po half-life time measurements with an amplitude of A = (6.9 ± 3) × 10{sup −4} and a phase of φ = 93 ± 10 days was found in a sequence of the week-collected τ-values obtained from the TAU-2 data sample with total duration of 480 days. 24 hours’ variation of the t-value measurements with an amplitude of A = (10.0 ± 2.6) × 10{sup −4} and phase of φ = 1 ± 0.5 hours was found in a solar day 1 hour step t-value sequence formed from the same data sample. It was found that the {sup 214}Po half-life averaged at 480 days is equal to 163.45 ± 0.04 μs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

THE SYSTEMATIC ERROR TEST FOR PSF CORRECTION IN WEAK GRAVITATIONAL LENSING SHEAR MEASUREMENT BY THE ERA METHOD BY IDEALIZING PSF

We improve the ellipticity of re-smeared artificial image (ERA) method of point-spread function (PSF) correction in a weak lensing shear analysis in order to treat the realistic shape of galaxies and the PSF. This is done by re-smearing the PSF and the observed galaxy image using a re-smearing function (RSF) and allows us to use a new PSF with a simple shape and to correct the PSF effect without any approximations or assumptions. We perform a numerical test to show that the method applied for galaxies and PSF with some complicated shapes can correct the PSF effect with a systematic error of less than 0.1%. We also apply the ERA method for real data of the Abell 1689 cluster to confirm that it is able to detect the systematic weak lensing shear pattern. The ERA method requires less than 0.1 or 1 s to correct the PSF for each object in a numerical test and a real data analysis, respectively.

79 ASTRONOMY AND ASTROPHYSICS↗

Systematic errors in low-latency gravitational wave parameter estimation impact electromagnetic follow-up observations

Among the most eagerly anticipated opportunities made possible by Advanced LIGO/Virgo are multimessenger observations of compact mergers. Optical counterparts may be short-lived so rapid characterization of gravitational wave (GW) events is paramount for discovering electromagnetic signatures. One way to meet the demand for rapid GW parameter estimation is to trade off accuracy for speed, using waveform models with simplified treatment of the compact objects’ spin. We report on the systematic errors in GW parameter estimation suffered when using different spin approximations to recover generic signals. Component mass measurements can be biased by >5σ using simple-precession waveforms and in excess of 20σ when non-spinning templates are employed. This suggests that electromagnetic observing campaigns should not take a strict approach to selecting which LIGO/Virgo candidates warrant follow-up observations based on low-latency mass estimates. For sky localization, we find that searched areas are up to a factor of ∼2 larger for non-spinning analyses, and are systematically larger for any of the simplified waveforms considered in our analysis. Distance biases for the non-precessing waveforms can be in excess of 100% and are largest when the spin angular momenta are in the orbital plane of the binary. We confirm that spin-aligned waveforms should be used for low-latency parameter estimation at the minimum. Including simple precession, though more computationally costly, mitigates biases except for signals with extreme precession effects. Our results shine a spotlight on the critical need for development of computationally inexpensive precessing waveforms and/or massively parallel algorithms for parameter estimation.

79 ASTRONOMY AND ASTROPHYSICS↗

Systematic errors in Sunyaev-Zeldovich surveys of galaxy cluster velocities

Galaxy cluster surveys compiled via the Sunyaev-Zeldovich Effect have the potential to place strong constraints on cosmology, and in particular the nature of dark energy. Here we consider cluster velocity surveys using kinetic Sunyaev-Zeldovich measurements. Cluster velocities closely trace the large-scale velocity field independent of cluster mass; we demonstrate that two useful cluster velocity statistics are nearly independent of cluster mass, in marked contrast to cluster number count statistics. On the other hand, cluster velocity determinations from three-band observations of Sunyaev-Zeldovich distortions can require additional cluster data or assumptions, and are complicated by microwave emission from dusty galaxies and radio sources, which may be correlated with clusters. Systematic errors in velocity due to these factors can give substantial biases in determination of dark energy parameters, although large cluster velocity surveys will contain enough information that the errors can be modeled using the data set itself, with little degradation in cosmological constraints.

79 ASTRONOMY AND ASTROPHYSICS↗

Managing systematic errors in the NBSR thermal power calorimetric measurements - 214

There has been a calorimetric misbalance between the primary and secondary loops of the National Bureau of Standards Reactor (NBSR) since the installation of a set of new heat exchangers in the early 90's. The NBSR's primary and secondary process instrumentation were investigated to resolve the underlying causes. The main issue was found to be the immersion length of the thermowells, resulting in non-exemplary process measurements. Furthermore, thermal insulation on various temperature sensors was found to be degraded. Hence, the following were found to be inconsistent: the heat exchanger output temperatures, previously-used differential temperature sensors, reactor inlet sensor, and the reactor outlet temperature indications. Therefore, thermodynamic analyses using these sensor measurements were inconclusive. Secondly, the discrepancy between primary and secondary loops and the gradual inconsistency between primary side sensors went largely unnoticed. We implemented sustainable, state-of-the-art upgrades to resolve systematic errors in the NBSR reactor thermal process instrumentation. Several digital upgrades were completed, along with detailed 50.59 reviews. Redundancy, defense-in-depth, reliability, diversity and accuracy of the thermal monitoring system was established by implementing an inclusive engineering approach by analyzing the sensors as a whole system instead of individual assessments. The upgrades produced two important outcomes. First, the long-term existing calorimetric discrepancy between the primary and secondary loops was resolved. Secondly, excellent agreement was achieved within the primary process measurement instrumentation, resulting in reliable and stable thermal power assessment. We will present lessons learned performing instrumentation upgrades and our future enhancement plans in process monitoring for the NBSR reactor. (authors)