Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “system advisor model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Electrolyzers in the System Advisor Model (SAM): A Techno-Economic Potential Study

A technoeconomic analysis of grid to low temperature electrolysis (Grid-LTE), photovoltaic to low temperature electrolysis (PV-LTE), concentrating solar power to high temperature electrolysis (CSP-HTSE) and a concentrating solar power with PV to high temperature electrolysis (CSP-PV-HTSE) centralized hydrogen production systems are analyzed to assess the economics of system and to provide a baseline for comparing these technologies against hydrogen production cost targets. A framework integrating the system advisor model (SAM) and US Department of Energy hydrogen production models (H2A) is developed to assess these systems. The hydrogen levelized cost given current and future assumptions for technology cost and performance is evaluated at optimal system configurations. The framework described in this report integrates SAM with H2A electrolyzer technologies and provides analysts a detailed technoeconomic method to analyze concentrating and photovoltaic solar technologies to produce energy that are directly coupled to LTE and HTSEs that use that energy to split water into hydrogen and oxygen. The baseline hydrogen levelized cost (HLCs) for the GRID-LTE, PV-LTE, CSP-HTSE, and CSP-PV-HTSE systems in Daggett, CA are 2.82, 3.86, 3.68, and 2.90 $\$$USD 2016/kg H2 and 2.50, 2.13, 2.84, 2.15 $\$$USD 2016/kg H2 in the 2020 and 2050 scenarios respectively. To achieve the $\$$2/kg H2 target in locations with excellent solar resources, cost parameters values aligned with aggressive R&D targets will need to be achieved for all the systems configurations. In Daggett, PV costs of $\$$0.68 /Wac or moderate ATB PV CAPEX projections result in HLCs of $\$$2 /kg H2. Similarly for PV-MSALT-HTSE systems, $\$$0.60 /Wac result in $\$$2/kg H2. For the MSALT-HTSE systems, better than aggressive 2050 ATB salt tower CAPEX projections would be needed to reach $\$$2/kg H2. Molten salt tower capital costs of $\$$2400/kW would enable $\$$2/kg H2 in 2050.

08 HYDROGEN↗

Recent and Planned Improvements to the System Advisor Model (SAM)

This talk will focus on recent and planned modeling improvements to the NREL System Advisor ModelTM (SAM), with recently released features including PV hourly clipping correction, expanded geographic scope of SAM's NSRDB interface to Europe and Africa, and additional options for hybrids. Upcoming improvements include a case comparison feature, improved visualizations, and extensions of PVWatts for battery modeling and utility rate calculations.

batteries↗

Recent and Planned Improvements to the System Advisor Model (SAM)

This talk will focus on recent and planned modeling improvements to the NREL System Advisor ModelTM (SAM), including PV hourly clipping correction, expanded geographic scope of PVWatts including Ukraine, additional options for hybrids, and enhanced PySAM and GUI interoperability. Additional topics will also include: bifacial modeling features including irradiance on the ground for agrivoltaics, PV uncertainty simulation features, and integrations with other NREL and industry tools.

battery↗

Uncertainty Quantification of PV Annual Energy Estimates in the System Advisor Model

This work will detail a proposed uncertainty quantification method for PV annual energy estimates. Motivations behind the proposed methodology will be discussed, including the frequent underperformance of installed PV systems to calculated probability of exceedance values being seen in industry. A methodology in which uncertainty factors correlated to different parts of the PV annual energy model chain are applied to annual energy estimates in conjunction with uncertainty from inter-annual solar resource variability will be described. The application of this methodology in the System Advisor Model (SAM) will also be discussed with example cases and graphical outputs of the probability of exceedance data calculated for the PV annual energy estimates.

energy modeling↗

Presenting a Model to Predict Changing Snow Albedo for Improving Photovoltaic Performance Simulation

As photovoltaic (PV) deployment increases worldwide, PV systems are being installed more frequently in locations that experience snow cover. The higher albedo of snow, relative to the ground, increases the performance of PV systems in northern and high-altitude locations by reflecting more light onto the PV modules. Accurate modeling of the snow’s albedo can improve estimates of PV system production. Typical modeling of snow albedo uses a simple two-value model that sets the albedo high when snow is present, and low when snow is not present. However, snow albedo changes over time as snow settles and melts and a binary model does not account for transitional changes, which can be significant. Here, we present and validate a model for estimating snow albedo as it changes over time. The model is simple enough to only require daily snow depth and hourly average temperature data, but can be improved through the addition of site-specific factors, when available. We validate this model to quantify its ability to more accurately predict snow albedo and compare the model’s performance against satellite imagery-based methods for obtaining historical albedo data. In addition, we perform modeling using the System Advisor Model (SAM) to show the impact of changes in albedo on energy modeling for PV systems. Overall, our albedo model has a significantly improved ability to predict the solar insolation on PV modules in real time, especially on bifacial PV modules where reflected irradiance plays a larger role in energy production.

Pike, Christopher (ORCID:0000000155888033)↗

Understanding Solar Photovoltaic System Performance: An Assessment of 75 Federal Photovoltaic Systems

This report presents a performance analysis of 75 photovoltaic systems based on PV system production data collected as part of a FEMP Federal PV Performance Assessment project combined with co-incident insolation, and ambient temperature to analyze how actual performance compares with a performance model. FEMP collaborated with 17 Federal agencies and sub-agencies to collect the information required to analyze the performance of each system. The systems represent a total capacity of 30,714 kW and range in size from 1 kW to 4,043 kW, with an average size of 410 kW, and were installed between 2011 and 2020. The data is analyzed for Key Performance Indicators, Availability, Performance Ratio and Energy Ratio by comparing the measured production data to model production data. The System Advisor Model (SAM) combines a description of the system (such as inverter capacity, de-rating for temperature, balance-of-system efficiency) with environmental parameters (coincident solar and temperature data) to calculate predicted performance. The performance metrics are calculated by lining up the measured production data with the model estimate on an hour-by-hour, day-by-day, or month-by-month basis (depending on the interval resolution of the production data). A report with system description, photo of the system, special assumptions made for the site, graph of measured production and model production, table of key performance indicators, and links to O&M resources that might improve performance was produced and delivered to site and agency staff with a short on-line briefing.

14 SOLAR ENERGY↗

Side-by-Side Comparison of Subhourly Clipping Models

Over the past several years there have been numerous attempts at quantifying the inherent power clipping of inverters due to sub-hourly irradiance variability that is not captured in hourly PV performance models. Different models have been proposed to correct for these clipping losses in PV performance estimates, including matrix lookup models, distribution modeling of the PV power performance within a given hour, and machine learning methods. To date, there have been few comprehensive quantitative comparisons of these inverter clipping correction modeling approaches to evaluate the effectiveness of these approaches in predicting the actual behavior of PV system inverter clipping. In this study, we perform such a comparison, evaluating the Allen and Walker correction loss modeling approaches recently implemented in the System Advisor Model (SAM) against clipping losses modeled with 1-minute climate data. These comparisons were performed across a variety of climate locations and inverter loading ratios to thoroughly analyze the effectiveness of these modeling approaches relative to each other. Results from this analysis reveal that both clipping correction approaches improve annual energy accuracy to within 2% of 1-minute modeled energy yield. The two models predict annual clipping loss more accurately than simple hourly power limit clipping, with the Allen method typically being slightly more accurate at typical ILR values and the Walker method often being slightly more accurate at high ILR values The models can improve accuracy over the status quo clipping approach up to 3 percentage points in systems with ILR of 2.0, showing the importance of this modeling factor in energy yield estimates.

ENERGY PLANNING, POLICY, AND ECONOMY,MATHEMATICS A↗

Behind the Meter Storage for Electric Vehicle Charging, Electrochemical and Thermal Energy Storage, and Solar Photovoltaic

In response to the potentially large and irregular demand from EVs, along with changing load profiles from buildings with on-site generation, utilities are evaluating multiple options for managing dynamic loads, including time-of-use pricing, demand charges, battery storage, and curtailment of variable generation. Buildings, as well as commercial, public, and workplace EV charging operations, can use a combination of electrochemical battery storage and thermal energy storage coupled with on-site generation to manage energy costs as well as provide resiliency and reliability for EV charging and building energy loads. We are completing a behind the meter storage analysis that focuses on determining the optimal system designs and energy flows for thermal and electrochemical behind the meter storage with on-site solar photovoltaic (PV) generation enabling electric vehicle charging in various climates, building types, and utility rate structures. In completing this analysis, we have developed a tool that combines existing battery models via the System Advisor Model (SAM) and building modeling software via EnergyPlus into a single interface. This tool allows us to simulate a building with a detailed battery model to properly size the battery, thermal energy storage, and solar PV systems to maximize profit for the system owner. This also allows us to assess how the battery degrades under various supervisory control dispatch algorithms to control charging/discharging; we can also see how thermal energy storage is created and used to complement the battery to reduce thermal loads in the building. With this project, we can analyze new batteries that are designed specifically for energy storage, rather than designed to be extremely energy dense for electric vehicle applications, using battery lifetime models from other national labs and the existing SAM battery model, which has detailed lifetime and degradation parameters. We can also assess novel thermal storage technologies by integrating them into the whole building energy simulation program EnergyPlus. Because the model calls both SAM and EnergyPlus, required inputs need to be compatible for both models. These inputs include, on a high-level, the following: weather files, building and electric vehicle load profiles, electricity rate tariff information, and system cost information for the stationary battery, solar PV, and thermal storage system. The various buildings we are studying for this analysis are retail big-box grocery store, commercial office building, fleet vehicle depot and operations facility, multi-family residential, and electric vehicle charging station. For these different applications, the battery and thermal storage will be dispatched differently, and the various technologies are sized differently to optimize cost.

30 DIRECT ENERGY CONVERSION↗

Off-design performance of molten salt-driven Rankine cycles and its impact on the optimal dispatch of concentrating solar power systems

This paper presents a model for improving off-design performance predictions for molten salt-driven Rankine power cycles, such as in concentrating solar power tower applications. The model predicts cycle off-design performance under various boundary conditions, including molten salt inlet temperature, mass flow rate, and ambient temperature. The model is validated using industry performance data and benchmarked with results from the literature. A complete concentrating solar power plant, inclusive of solar heliostat field and receiver, is then considered, by implementing the Rankine cycle off-design performance results into the National Renewable Energy Laboratory’s System Advisor Model software, which includes a tool that determines optimal power production schedules. The work improves upon the current System Advisor Model by updating off-design performance characteristics. A case study demonstrates the impact of cycle off-design behavior on annual performance for a stand-alone concentrating solar power system and a concentrating solar power-photovoltaic hybrid system. In addition, we demonstrate how cycle off-design performance influences optimal operator dispatch decisions and, thereby, overall system design and economics. We conclude that off-design cycle performance impacts “optimal” sub-system sizing, especially for a concentrating solar power-photovoltaic hybrid configuration in which concentrating solar power must dispatch in conjunction with photovoltaic generation.

14 SOLAR ENERGY↗

Hybrid Solar Thermal Energy System for District Heating Application

Solar district heating (SDH) systems can be good alternatives to conventional systems when they are optimized with hybrid configurations and thermal energy storage (TES). In this scope, a hybrid renewable thermal energy system (RTES) model has been built combining flat plate collector (FPC) solar system with parabolic trough collector (PTC) system via a heat exchanger and coupled with TES. To undertake the hybridization of the system, System Advisor Model (SAM) software was modified, which allowed control over configurations and more accurate modelling of heat transfer between the collectors. The model is first compared to an existing hybrid solar district heating systems (DHS) system in Taars, Denmark. The results showed a good correlation with an overestimation of only 6.4% compared to most recent heat output. Then the same system configuration was modeled in different geographic locations to investigate the impact of changes in direct normal irradiance (DNI) to the heat sink thermal output of the hybrid system. The results showed that the annual net thermal power output in California, USA can be three times more than the annual net thermal power output in Taars, Denmark. Finally, multiple hybrid configurations with varying solar field sizes were simulated based on the heat demand of two different university campuses DHS. The results showed that, retrofit applications of this hybrid DHS system coupled with TES could reduce the natural gas consumption of the existing systems between 25% and 41%. The use of hybrid RTES highlighted in this paper can be extended to many more opportunities.

district heating↗

Renewable energy analysis in indigenous communities using bottom-up demand prediction

This paper provides a methodology for the holistic analysis of hybrid renewable energy systems in rural communities. Electric demand is an important component for modeling and analysis of renewable energy systems. Typically, electric demand data is not available due to the internal privacy policies of utility providers. Therefore, this study proposes the use of bottom-up approaches for the development of the electric demand profile, considering the general homogeneity of residential and commercial buildings in rural communities. As a test case, this study develops the electric demand profile and investigates the technical and environmental feasibility of a hybrid renewable energy system for the New Town community on the Fort Berthold Indian Reservation (FBIR) in North Dakota. This study conducts the hybrid renewable energy system’s analysis by developing scripts in the LK scripting language and integrating System Advisor Model software’s open-source modules for modeling of renewable energy systems. Here, the results for the validation testbed of this study show that hybrid renewable resources have higher ratios of energy used for self-consumption to the total energy generated compared to stand-alone wind and PV farms.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Design and Techno-Economic Analysis of a 150-MW Hybrid CSP-PV Plant

The interest in concentrated solar power (CSP) has increased significantly over the years since it is dispatchable and requires thermal storage instead of electric storage. When compared to photovoltaics (PV), CSP has a higher Levelized Cost of Electricity (LCOE). In this paper, we present the design of a hybrid power plant using CSP and PV technologies. The hybrid system offers a lower LCOE than CSP but will still have dispatchability. The 150-MW hybrid system consists of 100-MW CSP and 50-MW PV capacity. Furthermore, the CSP system (central receiver system) has a molten salt-based thermal storage of 12 hours. The geographical focus of this study is Pakistan, which is a developing country struggling with energy crises, but which has high solar potential. The hybrid system is modeled using the System Advisor Model (SAM). The results show that by hybridizing CSP with PV, the LCOE can be reduced by 18.5%.

concentrated solar power↗

Dynamically Downscaled Hourly Future Weather Data with 12-km Resolution Covering Most of North America

This is an hourly future weather dataset for energy modeling applications. The dataset is primarily based on the output of a regional climate model (RCM), i.e., the Weather Research and Forecasting (WRF) model version 3.3.1. The WRF simulations are driven by the output of a general circulation model (GCM), i.e., the Community Climate System Model version 4 (CCSM4). This dataset is in the EPW format, which can be read or translated by more than 25 building energy modeling programs (e.g., EnergyPlus, ESP-r, and IESVE), energy system modeling programs (e.g., System Advisor Model (SAM)), indoor air quality analysis programs (e.g., CONTAM), and hygrothermal analysis programs (e.g., WUFI). It contains 13 weather variables, which are the Dry-Bulb Temperature, Dew Point Temperature, Relative Humidity, Atmospheric Pressure, Horizontal Infrared Radiation Intensity from Sky, Global Horizontal Irradiation, Direct Normal Irradiation, Diffuse Horizontal Irradiation, Wind Speed, Wind Direction, Sky Cover, Albedo, and Liquid Precipitation Depth. The weather data is created for two emissions scenarios: RCP4.5 and RCP8.5 and spans two 10-year time slices in the future: 2045 - 2054 and 2085 - 2094. It offers a spatial resolution of 12 km by 12 km with extensive coverage across most of North America. Due to the enormous size of the entire dataset, in the first stage of its distribution, we provide 20 years of future weather data for the centroid of each Public Use Microdata Area (PUMA), excluding Hawaii. PUMAs are non-overlapping, statistical geographic areas that partition each state or equivalent entity into geographic areas containing no fewer than 100,000 people each. The 2,378 PUMAs as a whole cover the entirety of the U.S. The weather data can be utilized alongside the large-scale energy analysis tools, ResStock and ComStock, developed by National Renewable Energy Laboratory, whose smallest resolution is at the PUMA scale. The data for RCP4.5 is still being processed and will be published soon.

Array↗

Validation of Photovoltaic Modeling Tool Solargraf Against Measured Data

Solargraf is a cloud-based 3D design tool by Enphase Energy that allows users to design solar and storage systems with a variety of elements. Through a Cooperative Research and Development Agreement (CRADA), Enphase Energy collaborated with the National Renewable Energy Laboratory (NREL) to validate Solargraf's 3D design simulation against measured PV system performance. This study follows the same methodology of similar validation studies completed at NREL. The predicted performance results from simulations in both Solargraf and NREL's System Advisor Model (SAM) tool were compared with measured data to evaluate performance predictions.

14 SOLAR ENERGY↗

Spaced out: An economic framework to explore the impacts of PV panel spacing on large-scale farming in Colorado

CONTEXT Agrivoltaic systems co-locate solar technologies with agricultural operations on an integrated plot of land and potentially provide benefits to both energy and agricultural systems. To date, large-scale (>5-MW) agrivoltaic projects in the United States have been limited to grazing and ecovoltaic applications, raising questions about the impact and scalability of agrivoltaic crop systems. Many agrivoltaic designs raise the height of the solar panels to accommodate agricultural practices while keeping energy density high. However, raising the panels results in increased photovoltaic (PV) development costs, which often are higher than the economic returns of crop production underneath the panels. This leads to unfavorable project economics and the need for other agrivoltaic solutions than raising panels. OBJECTIVE To explore other solutions, we perform an initial feasibility analysis for an agrivoltaic solution that can integrate with large-scale farming practices by increasing the row spacing in between panels. Increased PV row spacing is a low-cost approach for scaling agrivoltaics to accommodate crop production and this spacing can be tailored to required crop equipment for different regions. Increasing row spacing will reduce the power density (PV installed per acre), but in areas that are not land limited, these agrivoltaic designs could be economically feasible. Our analysis establishes a framework for a feasibility analysis for where and with what crops spaced out panel agrivoltaic solutions might be economical. METHODS Using a case study for large-scale agriculture crops in Colorado, we establish a framework for wide-row agrivoltaic economic feasibility analysis. We utilized the System Advisor Model to calculate technoeconomic metrics to compare different row spacing solutions and capture tradeoffs of these system designs. RESULTS AND CONCLUSIONS We find that, in some circumstances, wider row agrivoltaic solutions that allow for continued mechanized crop production can provide economic benefits over a traditional utility-scale PV system. For most crops examined in this analysis, roughly $\$$200/acre in agricultural profit justified spacing out the panels to at least 31.7 ft. to accommodate agrivoltaic configurations versus PV only configurations. Additionally, opportunities for increased agricultural revenue with agrivoltaic systems allow PV project economics to tolerate a larger range of CAPEX variability while remaining economically viable relative to the PV only configurations. SIGNIFICANCE This framework can be adapted for a wide variety of crops and regions and allows for examination of economically favorable sites for future agrivoltaic systems that utilize different configuration and expand opportunities for agrivoltaics.

14 SOLAR ENERGY↗

Improvement in PV Plant LCOE from Convection Heat Transfer Changes from Altered Plant Layout

Heat transfer modeling that accounts for how convective cooling changes with PV array layout has been found to improve system LCOE in certain climates conditions. Analysis of fixed tilt systems performed using the System Advisor Model reveals that reducing system ground coverage ratio from 0.46 to 0.35 can lead to as much as a 1.7% increase in module annual energy output in Phoenix. Depending on climate conditions, these energy increases due to changing convective cooling flow can lead to LCOE improvements for systems with increased row spacing despite the increased wiring and land costs associated with increased module row spacing. While the energy gain from decreasing system ground coverage ratio can be largely attributed to increased plane of array irradiance, the convection cooling considerations presented here can have a non-negligible impact on PV power plant energy output and economic viability depending on climate conditions and array spacing parameters.

heat transfer↗

NREL's Tools for AgriPV Modeling

As part of the Tools and Apps for Agrivoltaics session, NREL presents their tools that have capabilities for modeling PV and agricultural dual use sites. These include the System Advisor Model (SAM), bifacial_radiance open-source raytracing tool, and a simplified agriPV calculator available in the InSPIRE website.

agriculture↗