Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “superconducting resonator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Physical patterning of high-Q superconducting niobium resonators via ion beam etching

The development of superconducting quantum circuits increasingly involves the exploration of chemically distinct materials and complex multilayered structures. Accelerating this trend may benefit from low-damage, materials-agnostic patterning techniques that are compatible with a broad range of materials. Here, in this work, we investigate the utility of low-energy ion beam etching (IBE), a physical patterning technique, as an alternative to reactive ion etching for fabricating low-loss superconducting resonators. We use niobium (Nb) resonators as a test platform, leveraging their well-characterized performance metrics for benchmarking. To address IBE-induced surface redeposition, we introduce an in situ aluminum capping layer combined with targeted post-fabrication chemical treatment. This strategy yields resonators with internal quality factors as high as 6 × 10 5 in the single-photon regime at 50 mK. These results establish low-energy IBE as a promising patterning technique for superconducting devices, with the potential to accelerate development across chemically diverse and multilayered material platforms.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SQUID Readout of a High-$Q$ Superconducting $LC$ Resonator

We demonstrate the readout of a superconducting $LC$ resonator, with $Q \approx 2 \times 10^{6}$ at approximately 250 kHz, using a dc SQUID followed by a SQUID series-array amplifier readout chain. We find that $Q$ depends on the SQUID flux-bias point, increasing near the shallow-slope point of the SQUID modulation curve and decreasing near the steep-slope point, consistent with the previously observed SQUID damping effects. From this variation, we infer the SQUID effective input impedance. We further infer the effective temperature of the resonator circuit from the resonance peak in the noise spectrum and show that it also depends on the SQUID flux-bias point, suggesting a possible contribution from SQUID back-action noise. This system provides a working prototype for future experiments based on lumped-element resonators with SQUID readout, in particular low-mass axion searches within the DMRadio program.

FOS: Physical sciences↗

Highly Stable Microwave Resonator

Superconducting walls on sapphire-filled cavity make low-loss device. Improved microwave resonant cavity consists of sapphire cylinder coated with thin film of superconducting lead. Operated well below superconducting transition temperature at 1.5K, cavity demonstrated superior frequency stability and quality factor. Cavity frequency highly stable and therefore suitable for use in standard frequency generators and filters.

Strayer, Donald M.↗

A scanning resonator for probing quantum coherent devices

Superconducting resonators with high quality factors are extremely sensitive detectors of the complex impedance of materials and devices coupled to them. This capability has been used to measure losses in multiple different materials and, in the case of circuit quantum electrodynamics (circuit QED), has been used to measure the coherent evolution of multiple different types of qubits. Here, we report on the implementation of a scanning resonator for probing quantum coherent devices. Our scanning setup enables tunable coherent coupling to systems of interest without the need for fabricating on-chip superconducting resonators. We measure the internal quality factor of our resonator sensor in the single-photon regime to be >104 and demonstrate capacitive imaging using our sensor with zeptoFarad sensitivity and micron spatial resolution at milliKelvin temperatures. We then use our setup to characterize the energy spectrum and coherence times of multiple transmon qubits with no on-chip readout circuitry. Our experiments introduce a new tool for using circuit QED to measure existing and proposed qubit platforms.

47 OTHER INSTRUMENTATION↗

Study of ponderomotive instability in the FRIB beta=0.53 half-wave resonator

Superconducting radio-frequency niobium cavities are susceptible to deformations caused by external or internal forces, leading to shifts in the cavity resonant frequency. One source of deformation comes from the radiation pressure of the cavity fields, producing the so-called Lorentz force detuning effect. This effect can couple to the cavity mechanical modes in generator driven mode, leading to ponderomotive instability. In the FRIB 322 MHz, β=0.53 Half-wave Resonators (HWR), the instability appeared when the cavity was detuned, with thresholds depending on low-level RF control parameters, such as closed loop gain, as well as accelerating gradient. Using a measured Lorentz Transfer Function, Simulink simulations were conducted to predict the instability thresholds, which were then compared with the experimental results. We will discuss how these thresholds can be broadened to enable stable operation at higher gradients.

Accelerator Physics↗

Ten Ghz YBa2Cu3O(7-Delta) Superconducting Ring Resonators on NdGaO3 Substrates

YBa2Cu3O(7-delta) thin films were formed on NdGaO3 substrates by laser ablation. Critical temperatures greater than 89 K and critical current densities exceeding 2 x 10(exp 8) Acm(sub -2) at 77 K were obtained. The microwave performance of films patterned into microstrip ring resonators with gold ground planes was measured. An unloaded quality factor six times larger than that of a gold resonator of identical geometry was achieved. The unloaded quality factor decreased below 70 K for both the superconducting and gold resonators due to increasing dielectric losses in the substrate. The temperature dependence of the loss tangent of NdGaO3 was extracted from the measurements.

To, H. Y.↗

10 GHz YBa2Cu3O7-delta Superconducting Ring Resonators on NdGaO3 Substrates

YBa2Cu3O7-delta thin films were formed on NdGaO3 substrates by laser ablation. Critical temperatures greater than 89 K and critical current densities exceeding 2 x 10(exp.6) A cm(exp.-2) at 77 K were obtained. The microwave performance of films patterned into microstrip ring resonators with gold ground planes was measured. An unloaded quality factor six times larger than a that of a gold resonator of identical geometry was achieved. The unloaded quality factor decreased below 70 K for both the superconducting and gold resonators due to increasing dielectric losses in the substrate. The temperature dependence of the loss tangent of NdGaO3 was extracted from the measurements.

To, H. Y.↗

Performance and modeling of superconducting ring resonators at millimeter-wave frequencies

Microstrip ring resonators operating at 35 GHz were fabricated from laser ablated YBCO thin films deposited on lanthanum aluminate substrates. They were measured over a range of temperatures and their performance compared to identical resonators made of evaporated gold. Below 60 Kelvin the superconducting strip performed better than the gold, reaching an unloaded Q approximately 1.5 times that of gold at 25 K. A shift in the resonant frequency follows the form predicted by the London equations. The Phenomenological Loss Equivalence Method is applied to the ring resonator and the theoretically calculated Q values are compared to the experimental results.

Bhasin, K. B.↗

YBCO superconducting ring resonators at millimeter-wave frequencies

Microstrip ring resonators operating at 35 GHz were fabricated from laser ablated YBCO films deposited on lanthanum aluminate substrates. They were measured over a range of temperatures and their performances compared to identical resonators made of evaporated gold. Below 60 Kelvin the superconducting strip performed better than the gold, reaching an unloaded Q approximately 1.5 times that of gold at 25 K. A shift in the resonant frequency follows the form predicted by the London equations. The Phenomenological Loss Equivalence Method is applied to the ring resonator and the theoretically calculated Q values are compared to the experimental results.

Chorey, Christopher M.↗

Comparative S/TEM study of superconducting Ta quantum resonators by wet and dry etching types

Superconducting resonators play a pivotal role in various quantum technology applications, such as quantum computing and high-frequency communication systems. The performance of these resonators is closely tied to the properties of the superconducting films used in their fabrication. Here, in this study, we investigated the impact of wet and dry etching on tantalum (Ta) films leveraging advanced scanning transmission electron microscopy-based characterization methods and examined the morphological, chemical, and strain changes caused by the etching processes. Consequently, we report the significant differences between the two etching methods, with dry etching resulting in straight slanted sidewalls and a thinner oxidized layer, while wet etching produced curved sidewalls and undercuts. Both methods led to the formation of a residual Ta wedge at the lower part of the sidewall, causing lattice deformation, which could adversely influence the homogeneous operations of superconducting devices. These insights enhance our understanding of how etching influences superconducting films, offering valuable guidance for optimizing resonators and related devices. Our findings mark a significant stride in advancing quantum technologies and high-frequency communication by enhancing our practical understanding of superconducting material fabrication.

36 MATERIALS SCIENCE↗

Microwave Kinetic Inductance Detector with Selective Polarization Coupling

A conventional low-noise detector requires a technique to both absorb incident power and convert it to an electrical signal at cryogenic temperatures. This innovation combines low-noise detector and readout functionality into one device while maintaining high absorption, controlled polarization sensitivity, and broadband detection capability. The resulting far-infrared detectors can be read out with a simple approach, which is compact and minimizes thermal loading. The proposed microwave kinetic inductance detector (MKID) consists of three basic elements. The first is the absorptive section in which the incident power is coupled to a superconducting resonator at far-infrared frequency above its superconducting critical frequency (where superconductor becomes normal conductor). This absorber's shape effectively absorbs signals in the desired polarization state and is resonant at the radio frequency (RF) used for readout of the device. Control over the metal film used in the absorber allows realization of structures with either a 50% broadband or 100% resonance absorptance over a 30% fractional bandwidth. The second element is a microwave resonator - which is realized from the thin metal films used to make the absorber as transmission lines - whose resonance frequency changes due to a variation in its kinetic inductance. The resonator's kinetic inductance is a function of the power absorbed by the device. A low-loss dielectric (mono-crystalline silicon) is used in a parallel-plate transmission line structure to realize the desired superconducting resonators. There is negligible coupling among the adjacent elements used to define the polarization sensitivity of each detector. The final component of the device is a microwave transmission line, which is coupled to the resonator, and allows detection of changes in resonance frequency for each detector in the focal plane array. The spiral shape of the detector's absorber allows incident power with two polarizations to couple to the detector equally. A stepped impedance resonator was used that allows the incident power absorbed in the detecting membrane area to be uniformly distributed in the detector's transmission line at the RF readout frequency. This maximizes the sensitivity of the detector. The signal is read out via a frequency multiplexing technique that requires a minimum number of interface transmission lines for readout. This reduces the packaging complexity and coupling to the device's thermal environment.

Wollack, Edward↗

Automation of Data Analysis Programs Used in the Cryogenic Characterization of Superconducting Microwave Resonators

Knowledge of the microwave properties at cryogenic temperatures of components fabricated using High-Temperature-Superconductors (HTS) is useful in the design of HTS-based microwave circuits. Therefore, fast and reliable characterization techniques have been developed to study the aforementioned properties. In this paper, we discuss computer analysis techniques employed in the cryogenic characterization of HTS-based resonators. The revised data analysis process requires minimal user input. and organizes the data in a form that is easily accessible by the user for further examination. These programs retrieve data generated during the cryogenic characterization at microwave frequencies of HTS based resonators and use it to calculate parameters such as the loaded and unloaded quality factors (Q and Q(sub o), respectively), the resonant frequency (f(sub o)), and the coupling coefficient (k), which are important quantities in the evaluation of HTS resonators. While the data are also stored for further use, the programs allow the user to obtain a graphical representation of any of the measured parameters as a function of temperature soon after the completion of the cryogenic measurement cycle. Although these programs were developed to study planar HTS-based resonators operating in the reflection mode, they could also be used in the cryogenic characterization of two ports (i.e., reflection/transmission) resonators.

Creason, A. S.↗

Material exploration towards high quality factor microwave resonators

Niobium and aluminum have been widely used to realize superconducting resonators and qubits. However, the native oxide at the metal air interface limits the devices results. This layer is highly disordered, and it induces losses limiting the performances of the resonators or qubits. Recently, tantalum led to great improvement in qubit relaxation time. This improvement has been attributed to a thinner and less disordered oxide layer compared to Nb and Al. This study is aimed to limit the formation of the oxide layer, by the introduction of novel superconducting materials such as rhenium or by encapsulating the Nb surface with other superconducting materials such as Ta, Al, Re or other non-superconducting materials such as Au. To better understand the results, we are realizing these studies on coplanar waveguide resonators where the relation between surface losses and quality factor is clear. We are also analyzing different fabrication techniques to completely characterize our devices, linking material properties to the performances. In this work we are also varying the participation ratio of the devices in order to extract with higher fidelity and precision the losses introduced by the involved interfaces.

Crisa, F.↗

Unconventional inertial sensors.

Inertial sensors reviewing ring laser, electrostatic fluid sphere, magnetic resonance, superconductivity gyroscope, relativistic rotating tensor, vortex rate and quantum mechanical effect sensing

INERTIAL ACCELEROMETER↗

Low two-level-system noise in hydrogenated amorphous silicon

At sub-Kelvin temperatures, two-level systems (TLSs) present in amorphous dielectrics source a permittivity noise, degrading the performance of a wide range of devices using superconductive resonators such as qubits or kinetic inductance detectors. We report here on measurements of TLS noise in hydrogenated amorphous silicon (a-Si:H) films deposited by plasma-enhanced chemical vapor deposition in superconductive lumped element resonators using parallel-plate capacitors. In conclusion, the TLS noise results presented in this article for two recipes of a-Si:H improve on the best results achieved in the literature by a factor >5 for a-Si:H and other amorphous dielectrics and are comparable to those observed for resonators deposited on crystalline dielectrics.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Eliminating Surface Oxides of Superconducting Circuits with Noble Metal Encapsulation

The lifetime of superconducting qubits is limited by dielectric loss, and a major source of dielectric loss is the native oxide present at the surface of the superconducting metal. Specifically, tantalum-based superconducting qubits have been demonstrated with record lifetimes, but a major source of loss is the presence of two-level systems in the surface tantalum oxide. Here, we demonstrate a strategy for avoiding oxide formation by encapsulating the tantalum with noble metals that do not form native oxide. By depositing a few nanometers of Au or AuPd alloy before breaking vacuum, we completely suppress tantalum oxide formation. Microwave loss measurements of superconducting resonators reveal that the noble metal is proximitized, with a superconducting gap over 80% of the bare tantalum at thicknesses where the oxide is fully suppressed. Further, our findings suggest that losses in resonators fabricated by subtractive etching are dominated by oxides on the sidewalls, pointing to total surface encapsulation by additive fabrication as a promising strategy for eliminating surface oxide two-level system loss in superconducting qubits.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Coherent Magnon–Photon Coupling in the Magnetic Semiconductor CrSBr

Magnon-based hybrid quantum systems are promising candidates for quantum interconnects and quantum sensors, and they offer a rich platform for exploring nonlinear magnonics and cavity–photon interactions. Two-dimensional (2D) van der Waals magnets provide a compact, atomically flat geometry that can be easily integrated into existing quantum circuits, such as superconducting resonators and qubits. Among various 2D magnets, the magnetic semiconductor CrSBr is particularly unique due to its strong spin–exciton, spin–lattice, and magnon–exciton interactions. In this work, we demonstrate coherent coupling between antiferromagnetic (AFM) magnons in CrSBr and microwave photons in a niobium-(Nb)-based-on-chip resonator. We tuned the magnon–photon coupling strength by changing the number of CrSBr flakes integrated into the Nb microwave photon resonators. Furthermore, this work demonstrates the first step toward integrating layered van der Waals 2D magnets into superconducting microwave circuits, with full access for microwave and optical probing.

Electromagnetic radiation↗

High-bandwidth frequency domain multiplexed readout of transition-edge sensors for neutrinoless double beta decay searches

The next-generation of cryogenic neutrinoless double-beta decay experiments require increasingly fast readout in order to improve background discrimination. These experiments, operated as cryogenic calorimeters at ∼ 10 mK, are usually read out by high-impedance neutron transmutation doped (NTD) thermistors, which provide good energy resolution, but are limited by ∼ 1 ms response times. Superconducting detectors, such as transition-edge sensors (TESs) with a time resolution of ∼ 100 μs, offer superior timing performance over NTD semiconductor bolometers. To make this technology viable for an application to a thousand or more channels, multiplexed readout is necessary in order to minimize the thermal load and radioactive contamination induced by the readout. Frequency-domain multiplexing readout (fMUX) for TESs, previously developed at Berkeley Lab and McGill University, is currently in use for mm-wave telescopes with detector sampling rates in the order of 100 Hz. We demonstrate a new readout system, based on the McGill/Berkeley digital fMux readout, to satisfy the higher bandwidth and noise requirements of the next generation of TES-instrumented cryogenic calorimeters. Each multiplexing readout module comprises 10 superconducting resonators in the 1–5 MHz range and a DC superconducting quantum interference device (DC-SQUID), interfaced to high-speed field programmable gate array (FPGA)-based electronics for digital signal processing and low-latency SQUID feedback. The new readout samples detectors at 156 kHz, three orders of magnitude faster than its cosmology-oriented predecessor, and demonstrates a stable feedback bandwidth of 3 kHz in a real TES-based system.

47 OTHER INSTRUMENTATION↗