Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “subsurface stored heat”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

29 records · Page 2

H-2-SALT: Storing Fossil Energy as Hydrogen in Salt Caverns

Hydrogen storage in subsurface caverns is known as perhaps largest and longest-term energy storage system. While few such systems are currently in service (e.g., Texas; Teesside, UK), they are envisioned as being a pillar of the current energy transition that will allow intermittent power production from renewable sources (e.g., wind, solar) to be balanced with demand at grid-scale. In addition, hydrogen energy storage can allow existing fossil power plants to run more economically either by minimizing startups/shutdowns or by allowing them to take advantage of arbitrage. Finally, stored hydrogen can feed a variety of non-power users such as pipeline gas, heating, transportation, and manufacturing. The H-2-SALT paper study assessed the feasibility of a power-to-hydrogen system utilizing salt cavern storage of hydrogen in bedded salt in central Kansas, where over 750 such caverns have been constructed to date, of which approximately 350 are still in service. Legacy well and salt cavern data were collected to develop a regional geological database for two sites in Central Kansas and adjacent areas for use in more detailed geological and geomechanical site characterization efforts. This study found commercial viability and competitiveness of large-scale, electrolytic H 2 production and storage ($1.78 per kg H 2 ) that can be used for both electrical power supply to the grid during high-priced electricity periods (including co-firing with NG and fuel cell power production) and sale of H 2 for various industries, such as petrochemicals or transportation. The commercial potential of the H-2-SALT system is also relatively high because each of its components operate commercially today. It is recommended that a stratigraphic test well be drilled to collect log data and core samples that can reduce uncertainty surrounding geological and geomechanical properties of the salt beds that will be required for further cavern and energy storage system design studies.

03 NATURAL GAS↗

Investigating Performance of Geothermal Reservoirs With Bi-Directional Heat Transfer for Seasonal Thermal Storage Using Thermal-Hydraulic Reservoir Simulations

This paper presents initial simulation results of deep subsurface seasonal thermal storage of waste heat from a natural gas-fired power plant during the summer months for providing heating during winter months at the Cornell University main campus in Ithaca, New York. An injection temperature profile is calculated with the MEnU tool and numerical reservoir simulations are conducted with the simulator FALCON. Both a porous medium and large single fracture geothermal reservoir are considered at about 3 km depth with initial reservoir temperature of 75 degrees C. Simulations indicate that a much smaller reservoir - which is technically easier and less risky to develop - is sufficient when operating the reservoir for seasonal thermal storage instead of for continuous heat production. For example, storing 13 GWh of heat seasonally in a 100 m thick porous medium based on the Galway formation requires about 65 m of well spacing to limit the yearly variation in production temperature to 10 degrees C. Operating this reservoir for continuous heat production would require a well spacing of 365 m to limit the thermal decline to 10 degrees C after 10 years. Neglecting wellbore heat losses and assuming uniform and homogeneous properties, a round-trip thermal efficiency of 100% can be obtained if the yearly averaged injection temperature matches the initial reservoir temperature.

district heating↗

Achieving gigawatt-scale green hydrogen production and seasonal storage at industrial locations across the U.S

Onsite production of gigawatt-scale wind- and solar-sourced hydrogen (H 2 ) at industrial locations depends on the ability to store and deliver otherwise-curtailed H 2 during times of power shortages. Thousands of tonnes of H 2 will require storage in regions where subsurface storage is scarce, which may only be possible using liquid organic H 2 carriers. We evaluate aboveground system with a focus on providing technical insights into toluene/methylcyclohexane (TOL/MCH) storage systems in locations suitable for gigawatt-scale wind- and solar-powered electrolyzer systems in the United States. Here we show that the levelized cost of storage, at a national median of US dollar $1.84/kg-H 2 is spatially heterogeneous, causing minor impact on the cost of H 2 supply in the Midwest, and significant impact in Central California and the Southeast. While TOL/MCH may be the cheapest aboveground bulk storage solution evaluated, upfront capital costs, modest energy efficiency, reliance on critical materials and pre-sulfided catalysts, and greenhouse gas emissions from heating are opportunities for further development.

14 SOLAR ENERGY↗

Project Phase 1 Report: Reducing Data Center Peak Cooling Demand and Energy Costs With Cold Underground Thermal Energy Storage (Cold UTES)

Cold Underground Thermal Energy Storage (Cold UTES) is an ultra-long duration grid energy storage technology. With Cold-UTES, low-cost grid power is converted to cold thermal energy and stored in the native subsurface rock at the point of use. Cold UTES is one approach within the general category of engineered geothermal systems. Cold UTES for peak-hour cooling of data centers (DCs) was studied for deployment in Maricopa County, Arizona and Loudoun County, Virgina using thermal storage capacities from 4 GWh-th to over 1,000 GWh-th (>1 Terawatt-hour). The two sites have different power and transmission systems, available grid energy resources, daily and seasonal load profiles, weather conditions, and grid regulatory requirements. The study results indicate high value for both locations and because of this, likely indicates value across most of the US and the world. The basis of the study was a 1,000 MW-e hourly electric use of DC computing and auxiliary loads, which was modeled as 1 GW-th of thermal load to a dry cooled heat rejection system - i.e. a cooling system that does not consume water. The electric power required for cooling the DC varies as the air temperature changes. In cold weather only the dry-coolers are used, with an electrical load for cooling load as low as 10 MW-e. In hot summer hours, chillers and dry- coolers are required, which raises the electrical load for cooling load to as much as 300 MW-e. The continuous and peak cooling electrical loads result in a grid interconnection requirement of no less than 1,300 MW-e. From both a grid and thermal design modeling perspective the 1.3 GW-e could either be a single facility or result from the total load at multiple sites.

15 GEOTHERMAL ENERGY↗

Progress in Simulated Water Well Performance on Mars

Recent studies of human Mars missions considered the impacts of an abundant supply of in-situ, accessible water on these mission scenarios. Discovery of exposed water ice scarps in Martian mid-latitudes has bolstered the evidence for massive amounts of almost pure water in buried deposits in regions considered candidates for these future human missions. This paper describes progress towards adapting a long-standing terrestrial technique for accessing and extracting water from these mid-latitude sources of ice. This approach relies on mechanical drills to access the ice through overlying debris. Once the ice layer has been reached, a technique known as a Rodriguez Well, or Rodwell, is used to melt the ice, store the resulting water in a subsurface cavity until needed, and then pump the water to the surface for use. Previous work by the authors utilized a computer simulation to predict the performance of a Martian Rodwell. This simulation was originally developed to predict performance in terrestrial Polar Regions. Whereas the basic approach is appropriate for a similar well on Mars, several parameters had been empirically derived and required experiments simulating the Martian environment to determine the values appropriate for a Martian Rodwell simulation. These experiments have now been completed and preliminary values have been determined for the empirical parameters. Test results are consistent with a dimensionless Sh(Ra) correlation developed by Bower and Saylor (2009) and based on lab tests of water evaporating from a pool into a large air chamber. They are also consistent with correlations derived by Ingersoll (1970) and by Hecht (2002), based on natural-convection heat transfer. Each of these earlier correlations found Sh~Ra1/3, with the 1/3rd power characteristic of large Ra where the boundary layer over the pool surface is turbulent. A somewhat surprising result was that this power-law was found to extend into a range of Ra where laminar flow would be expected. Another surprising result was found in that instead of following established correlations for natural-convection heat transfer over flat plates, the dimensionless heat-transfer rates (Nu) were much larger and approximately independent of Ra. This suggests that mass transfer from the pool enhances convective heat transfer, possibly by enhanced mixing in the boundary layer. Although this possibility has been suggested in the literature, if it is proven to be true under these conditions it could play an important role in the use of a Rodwell on Mars, where evaporative mass transfer is enhanced relative to terrestrial wells.

Human Mars Mission↗

Ground ice on Mars - Inventory, distribution, and resulting landforms

A model is presented for the distribution of ground ice on Mars, and model predictions are compared with Viking Orbiter photographs of landforms possibly related to ground ice. Estimates of the amount of water originally outgassed on Mars and the amount of water presently on Mars are presented which show that approximately 90% of the estimated outgassed volume may be stored in the Martian subsurface as ground ice. The extent of the Martian cryosphere, the zone in which the temperature is below the freezing point of water and in which ground ice can exist, is examined, and it is shown that, in the presence of a protective surface layer approximately 10 m thick, ground ice may occur beneath the entire Martian surface. Observed features on the Martian surface considered most likely to reflect the presence of ground ice are discussed, including thermokarst-like pits and debris flows, and possibly polygonally patterned ground, curvilinear features and pingo-like mounds, and the geographic distributions of these features as seen in Viking photographs are examined. It is found that the possibly ice-related features are concentrated in the northern midlatitudes, the equatorial zone near Olympus Mons, and the Southern Hemisphere near the edge of the plains, indicating that subsurface ice may be present over the entire planet. The origin of the ice-related landforms is explained by a combination of volcanic heating and variations in insolation.

Rossbacher, L. A.↗

An Integrated Feasibility Study of Reservoir Thermal Energy Storage (RTES) in Portland, OR, USA

In regions with long cold overcast winters and sunny summers, Deep Direct-Use (DDU) can be coupled with Reservoir Thermal Energy Storage (RTES) technology to take advantage of pre-existing subsurface permeability to save summer heat for later use during cold seasons. Many aquifers worldwide are underlain by permeable regions (reservoirs) containing brackish or saline groundwater that has limited beneficial use due to poor water quality. We investigate the utility of these relatively deep, slow flowing reservoirs for RTES by conducting an integrated feasibility study in the Portland Basin, Oregon, USA, developing methods and obtaining results that can be widely applied to RTES systems elsewhere. As a case study, we have conducted an economic and social cost-benefit analysis for the Oregon Health and Science University (OHSU), a teaching hospital that is recognized as critical infrastructure in the Portland Metropolitan Area. Our investigation covers key factors that influence feasibility including 1) the geologic framework, 2) heat and fluid flow modeling, 3) capital and maintenance costs, 4) the regulatory framework, and 5) operational risks. By pairing a model of building seasonal heat demand with an integrated model of RTES resource supply, we determine that the most important factors that influence RTES efficacy in the study area are operational schedule, well spacing, the amount of summer heat stored (in our model, a function of solar array size), and longevity of the system. Generally, heat recovery efficiency increases as the reservoir and surrounding rocks warm, making RTES more economical with time. Selecting a base-case scenario, we estimate a levelized cost of heat (LCOH) to compare with other sources of heating available to OHSU and find that it is comparable to unsubsidized solar and nuclear, but more expensive than natural gas. Additional benefits of RTES include energy resiliency in the event that conventional energy supplies are disrupted (e.g., natural disaster) and a reduction in fossil fuel consumption resulting in a smaller carbon footprint. Key risks include reservoir heterogeneity and a possible reduction in permeability through time due to scaling (mineral precipitation). Lastly, a map of thermal energy storage capacity for the Portland Basin yields a total of 43,400 GWh, suggesting tremendous potential for RTES in the Portland Metropolitan Area.

14 SOLAR ENERGY↗

Planetary origin, evolution, and structure

Three areas of recent and ongoing research are presented. The first area is giant planet heatflows. Conventional wisdom attributes the heatflow of the giant planets to the gradual loss of primordial heat, except in the case of Saturn where helium separation is evidently occurring. There are two problems with this picture: (1) the observed helium abundance of Saturn's atmosphere is so low that Jupiter must also be differentiating helium since its internal entropy cannot be much higher than Saturn; and (2) the heatflow of Neptune (not to mention Uranus) is too high to be consistent with adiabatic cooling from an initial hot state. A self-consistent solution to these two problems is presented. The second area covered is that of the despinning protogiant planets. Modeling of the possible despinning of these protoplanets by hydromagnetic torques was performed and the model results are discussed. The third area covered is how Titan hides its ocean. Until recently, the favored picture of Titan's surface was a roughly kilometer-thick ethane/methane ocean, presumably global in extent with at most a few outcroppings of dry land. The depth of the ocean is well constrained by observed atmospheric properties, and the constraints on subaerial topography are obtained indirectly from tidal considerations. A different picture of Titan's surface was pursued which was motivated by the perspective that methane on Titan should more properly be considered as a magmatic fluid. In this picture, methane is stored subsurface in magma chambers fed from deep-seated sources of methane, most probably due to the high pressure breakdown of methane clathrate. Other aspects of this model of Titan are presented.

Stevenson, David J.↗

Modeling Efforts to Gain Insight into Historical Leak Events from the Single-Shell Tank A-105 in the Hanford 241-A Tank Farm - 20113

The 241-A Tank Farm is a single-shell tank (SST) farm constructed to store process waste from Hanford nuclear operations. Millions of gallons of nuclear waste were stored in the 241-A Tank Farm SSTs and some of the SSTs leaked in the past. In addition, spills and pipeline leaks during transfers and storage and intentional discharges to cribs and trenches resulted in releasing waste to the ground. Tank liner leaks are referred to as 'leaks' and all other discharges to the soil are referred to as 'releases.' Liquid waste that could be removed by pumping has been removed from all of the SSTs to reduce the potential for future leaks. The most significant historical leak event in 241-A Tank Farm occurred in 1965 when tank A-105 experienced a pressurized steam event. This event resulted in damage to the inner steel liner flooring of A-105, which was separated from the sidewalls over part of its circumference and buckled up to 2.5 m, vertically. During this event up to 7,570 L of contaminated liquid may have leaked to the adjacent soil. This leak occurred under extreme temperature and pressure conditions. Modeling efforts to better understand the nature and extent of historical leaks from subsurface SSTs that were used to store highly radioactive, self-boiling liquid wastes at 241-A Tank Farm have recently been undertaken. These efforts have compiled the available historical information to support a preliminary non-isothermal, multiphase flow and chemical transport modeling effort to re-create the conditions under which the leaks occurred and to formulate a conceptual model as to the extent and distribution of leaked radioactive contaminants in the adjacent soil material. The focus of this work was on developing an understanding of the key features, processes and bounding conditions related to tank A-105 leak events that occurred in the 1960's. The activities include estimation of leak composition, non-isothermal multiphase flow and transport modeling, and geochemical modeling. The STOMP{sup C} Water-Air-Energy modeling code was utilized to implement the three-dimensional representation of the subsurface tank and the surrounding flow field. Once constructed, the model was used to evaluate the conceptual understanding of leaks originating from different parts of the tank under the elevated temperature boundary conditions that were imposed by surrounding tanks at the time of the historical leaks. The chemical evolution of the liquid waste was also evaluated as it leaked from the tank under transient pressure and temperature gradients. The results of the preliminary evaluation suggested the presence of a heat-pipe effect beneath tank A-105 in which water vapor at an elevated temperature is driven away from the base of the tank to a position where water vapor cools, condenses and is then drawn back toward the tank by the strong capillary attraction of the dry soil. A non-sorbing contaminant (Tc-99) was introduced into this flow field to better understand the potential distribution patterns of leaked contaminants that may have occurred during the historical leak events. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Geothermal Deep Direct Use for Turbine Inlet Cooling in East Texas

The National Renewable Energy Laboratory (NREL), the Southern Methodist University Geothermal Laboratory (SMU), Eastman Chemical (Longview, TX), and TAS (Houston, TX) evaluated the feasibility of using geothermal heat to improve the performance of a natural-gas power plant in East Texas. The area of interest is the Eastman Chemical plant in Longview, Texas, which is on the northwestern margin of a geologic region known as the Sabine Uplift. The feasibility study focused on determining the potential for accessing a subsurface hot-water geothermal resource within a 10-km radius of the site to provide thermal energy for absorption chillers. Wells within a 20-km radius are included for broader geological comparison to determine the heat flow, temperature-at-depth, field porosity and permeability. The lithologies of most interest are the Lower Cretaceous Trinity Group and Upper Jurassic Cotton Valley Group. The deeper Cotton Valley formations are hotter (averaging 117 to 130°C), yet permeability and porosity are low. The shallower Trinity Group contains more variability in permeability and porosity and lower temperatures averaging about 98 to 117°C. The shallower formations are considered despite the lower temperature because of increased ability to produce larger volumes of water and extract enough heat before reinjection. The complete SMU analysis is available in the National Geothermal Data System (NGDS). Tapping such deep geothermal sources for direct heating (as opposed to power generation) is known as geothermal deep direct use (DDU). Geothermal DDU has potential across a wide swath of the United States but is underutilized due to challenging project economics associated with developing a deep geothermal resource for what are typically small-scale, variable-demand projects. This project examines the feasibility of geothermal energy integration in a natural-gas combined cycle power station in East Texas. The DDU resource is tapped to drive absorption chillers (24/7) for production of chilled water at 5-10°C (41-50°F). This chilled water is stored until needed, which allows for continuous operation with a relatively small-capacity geothermal/absorption chiller system. When conditions are favorable, the chilled water is dispatched to cool the air entering the compressor stage of a gas combustion turbine. This process, known as turbine inlet cooling (TIC), boosts power production during periods of high temperature and high-power demand. Such systems can enhance grid reliability and reduce the cost for peak-demand power. A simulation model of the power plant was developed in IPSEpro software and validated against operational data from the plant. This model allowed the team to estimate the additional power that could be produced by applying TIC under different operating and ambient conditions. Absorption chiller performance was estimated from vendor sources to determine the production rate of chilled water from the geothermal resource. Geothermal drilling and development costs were estimated using NREL's GEOPHIRES 2.0. The expected lower drilling costs in this region led to an estimated cost of geothermal heat of about $4/MMBtu (1.4 cents/kWh t ). The estimated cost for the absorption chillers and TIC hardware were obtained from literature sources and project partners. Hourly data were obtained for weather, natural gas and electricity prices, and plant operating state for 2017, which served as a representative year. NREL estimated the capital cost, operating cost, and additional electricity production and revenue for different combinations of geothermal capacity, chiller capacity, and water storage-tank size. The analysis drove toward smaller geothermal and chiller systems to reduce equipment cost. A relatively low-cost water storage tank accumulated the near-continuous chilled water output for later use when TIC was most valued.

15 GEOTHERMAL ENERGY↗

Nationwide cost and capacity estimates for sedimentary basin geothermal power and implications for geologic CO 2 storage

Sedimentary basins are naturally porous and permeable subsurface formations that underlie approximately half of the United States. In addition to being targets for geologic CO 2 storage, these resources could supply geothermal power: sedimentary basin geothermal heat can be extracted with water or CO 2 and used to generate electricity. The geothermal power potential of these basins and the accompanying implication for geologic CO 2 storage are, however, understudied. Here, we use the Sequestration of CO 2 Tool (SCO2T PRO ) and the generalizable GEOthermal techno-economic simulator (genGEO) to address this gap by a) estimating the cost and capacity of sedimentary basin geothermal power plants across the United States and b) comparing those results to nationwide CO 2 sequestration cost and storage potential estimates. We find that across the United States, using CO 2 as a geothermal heat extraction fluid reduces the cost of sedimentary basin power compared to using water, and some of the lowest cost capacity occurs in locations not typically considered for their geothermal resources (e.g., Louisiana, South Dakota). Additionally, using CO 2 effectively doubles the sedimentary basin geothermal resource base, equating to hundreds of gigawatts of new capacity, by enabling electricity generation in geologies that are otherwise (with water) too impermeable, too thin, too cold, or not deep enough. We find there is competition for the best sedimentary basin resources between water- and CO 2 -based power, but no overlap between the lowest-cost resources for CO 2 storage and CO 2 -based power. In this way, our results suggest that deploying CO 2 -based power may increase the cost of water based systems (by using the best resources) and the cost of CO 2 storage (by storing CO 2 in locations that otherwise may not be targeted). As such, our findings demonstrate that determining the best role for sedimentary basins within the energy transition may require balancing tradeoffs between competing priorities.

CPG↗