Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “subcritical multiplication”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Cross Section Generation Capability in Griffin

The Griffin code is a Multiphysics Object-Oriented Simulation Environment (MOOSE) based reactor multiphysics analysis application jointly developed by Idaho National Laboratory and Argonne National Laboratory. The code includes a variety of steady-state solvers for fixed-source, k-eigenvalue, adjoint, and subcritical multiplication, as well as transient solvers for point-kinetics, improved quasi-static, and spatial dynamics. The code reads multigroup cross sections in the ISOXML format generated from external deterministic or Monte Carlo cross section generation codes. The implementation of the cross section generation capability in Griffin was initiated last year by plugging in the cross section application programming interface (CSAPI) and reviewing the methodologies for treating particulate fuels. The focus this year was on improving the CSAPI integration and implementing advanced self-shielding methods for applications to advanced reactor problems with TRISO fuels. First, the process for cross section library generation was updated to accurately and rigorously produce isotopic cross section data. Second, the on-the-fly slowing down method for the resonance treatment was implemented in CSAPI to improve the accuracy of effective multigroup cross sections in the resonance energy range. Among various on-the-fly slowing down methods, the equivalent Dancoff factor cell method was employed. Third, the iterative local spatial self-shielding method was implemented under the calculation framework of the equivalent Dancoff factor cell method to accurately deal with the double heterogeneity effect of particulate fuel. The updated CSAPI with the advanced self-shielding methods, together with the cross section libraries generated based on the improved process, were tested for the very high temperature reactor (VHTR), high temperature test reactor (HTTR), and Empire benchmark problems with various resonance self-shielding conditions, indicating that the updated CSAPI in Griffin is able to produce multigroup cross sections accurately and efficiently. We also show that the methodology works well for pebble bed fuel from HTR-10, but the capability still needs to be fully integrated into CSAPI. In the future, further benchmark tests will be performed for various thermal reactor core problems, including particulate fuel-based pebble bed reactors.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Improvements to the Griffin Transport Solvers

Griffin is a Multiphysics Object-Oriented Simulation Environment (MOOSE) based reactor multiphysics analysis application jointly developed by Idaho National Laboratory and Argonne National Laboratory. The code includes a variety of steady-state solvers for fixed-source, k-eigenvalue, adjoint, and subcritical multiplication, as well as transient solvers for point-kinetics, improved quasi-static, and spatial dynamics. This document summarizes the transport solver development efforts pursued during Fiscal Year 2022. We added the multiphysics transient capability for the coarse-mesh finite difference accelerated Richardson iteration for discontinuous finite element method discrete ordinates (DFEM-SN) scheme to support high-order heterogeneous transport simulations. HFEM (hybrid finite element method) - PN (spherical harmonics expansion) was completed and red-black iteration was added for solving the HFEM-PN system with both preconditioned Jacobian-free Newton Krylov and Richardson iteration solvers. The HFEM-PN scheme, as one of the low-order transport schemes, is expected for supporting routine design simulations. Pin power reconstruction capability was also designed and implemented with the Griffin ISOXML module to enhance all the low-order transport solvers for more accurate multiphysics simulations. Numerical results are presented for demonstrating the capabilities and verifying their performance, and future works are discussed.

97 MATHEMATICS AND COMPUTING↗

Critical and Californium Source-Driven Noise Analysis Subcritical Measurements with an Unreflected Cylindrical Tank of Mixed Uranium-Plutonium Nitrate Solution

The reported experiments were performed by Oak Ridge National Laboratory (ORNL) at the Battelle Northwest Laboratory’s (now Pacific Northwest National Laboratory) critical experiments facility at Hanford, Washington in 1981 and used 16 days of critical facility time, not including 10 days for setup and removal of ORNL equipment. These measurements were to assess the capability of the Cf source-driven noise analysis (CSDNA) method to measure the subcriticality (keff) of mixed U-Pu nitrate solutions. In addition to the CSNDA measurements, measurements were also performed near delayed criticality where CSDNA measurements cannot be performed. This report documents the experiments that were not reported at that time by presenting the ORNL experimental results and any online analysis performed during and shortly after the measurements. The mixed nitrate solution had a U concentration at 188 grams per liter (g/L), a Pu concentration of 280 g/L, free acid normality of 2.80, H ion molarity of 5.9 and a specific gravity of 1.754 g/cm 3 , a 240 Pu isotopic content of 7.981 wt. %, and a 235 U isotopic content of 0.724 wt. %. The stainless-steel tank for the solution had an inside diameter of 35.38 cm, an outside diameter of 35.53 cm, a height of 56.72 cm, and bottom thickness of 0.9525 cm. A Zircaloy pipe with a 3.1496 cm outside diameter, a 2.7788 cm inside diameter, and bottom thickness of 0.635 cm was available for insertion of the Cf source in the center of the fissile solution. The Cf source was also located at the outside surface of the tank (solution height varied from 10 to 53 cm) and in the center of the solution (solution height varied from 10 to 60.7 cm). The CSDNA measurements were not analyzed online to determine the subcritical neutron multiplication factors. At all subcritical states, the break frequency noise analysis data was fitted to obtain the prompt neutron decay constant. The neutron multiplication factors were determined for the two configurations of the measurements near delayed criticality. The subcritical neutron multiplication factors from the CNSDA measurements can be obtained with further analysis. However, the near delayed critical configuration, the prompt neutron decay constants, the count rates, and the measured cross and auto power spectral densities can be calculated directly for benchmarking. Much of data presented in this report are from ORNL notes—not in the ORNL logbooks. For the final benchmark analysis, the data from the Battelle Northwest Laboratory (which operated the critical facility in 1981) critical facility logbook should be consulted and be incorporated where appropriate. The purpose of this report is to document the experimental information for the measurements performed so that at a later date researchers could perform the required uncertainty and calculational analyses and documentation to use these data for an International Criticality Safety Benchmark Program (ICSBEP) or Nuclear Energy Agency benchmark. The data from these measurements are available from the ORNL Records Management Services Department, and the logbook is available from ICSBEP at Idaho National Laboratory. Preparation of the present report is part of a larger cooperative effort between Idaho National Laboratory (INL) and Oak Ridge National Laboratory (ORNL) to document more than 15 undocumented critical and subcritical experiments enumerated in ORNL/TM-2019/18 and performed by ORNL at ORCEF and other USDOE critical experiments facilities using more than 500 operational days of critical facility time.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Initial Delayed Critical Configuration of SHEBA I and Subcritical Measurements by Californium Source-Driven Noise Analysis

In September 1980, the initial delayed critical configuration of the Solution High-Energy Burst Assembly (SHEBA I) was assembled, and the US Department of Energy’s Oak Ridge National Laboratory (ORNL) staff performed near critical and subcritical measurements using the californium source-driven noise analysis (CSDNA) method at the Los Alamos National Laboratory (LANL) Critical Experiments Facility. An unreflected 56 cm outside diameter stainless-steel cylindrical tank was partially filled with uranyl fluoride solution (235U enrichment was 4.95 wt %) until delayed criticality was achieved. Then, measurements were performed for various fuel solution heights from delayed critical to 60% of the height required for delayed criticality. The stainless-steel tank had an inside diameter of 54.6 cm and a height of 105 cm and was partially (20–36.5 cm) filled with an aqueous solution of uranyl fluoride (with a density of 2.162 g/cm 3 ). The density of the uranium in solution was 1.042 g/cm 3 , and the solution had a H/U atomic ratio of 20.43. The tank had a 6.35 mm wall thickness and an axial reentrant tube with an inside diameter of 6.02 cm and wall thickness of 0.165 cm. The tank was essentially unreflected on the top and sides because it was in a thin metal shed. The reactivity of the near–delayed critical configuration was −10.4 cents, which corresponds to a k eff value of 0.99922. In addition to the CSDNA measurements, the prompt neutron decay constants were determined from break frequency noise analysis (BNFA) measurements. The subcritical neutron multiplication factors from CSDNA and BFNA compared extremely well. These data can be used as the basis of International Nuclear Criticality Safety Evaluation benchmark for the near-critical configuration, and the k eff values at various subcritical configurations can be used as subcritical benchmarks. Furthermore, the measured prompt neutron decay constants can be used as reactor physics benchmarks. This report documents the experimental information for the measurements performed so that, at a later date, researchers could perform the required uncertainty and calculational analyses and documentation to use these data for an International Criticality Safety Benchmark Evaluation Program (ICSBEP) or Nuclear Energy Agency benchmarks. The measured prompt neutron decay constants can be used as the basis of a benchmark for the International Reactor Physics Evaluation Program (IRPhEP). The data from these measurements are available from the ORNL Records Management Services Department, and the logbook is available from ICSBEP at Idaho National Laboratory.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Equivalent Fundamental-Mode Source Simulations for Spherical Uranium and Plutonium Systems

It is important in neutron noise measurements and reactor startup to understand how the source distribution in a system compares to the equivalent fundamental-mode (EFM) source. Deviation from the fundamental mode source distribution increases as the system $\kappa$ eff increases. A correction factor, g *, is a measure of this deviation, and is the focus of this work. Two methods were utilized to simulate g *. These methods are compared to each other and (where applicable) previous results. The effects associated with nuclear material inner radius, materials of reflectors, and reflector thickness are also investigated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Analysis of the MUSIC 3 He Multiplicity Data

A measurement campaign called the Measurement of Uranium Subcritical and Critical (MUSiC) was performed on a range of configurations of highly-enriched uranium (HEU) from December 2020 through April of 2021. While part of the focus was to measure reactor kinetics parameters on delayed supercritical systems, an additional focus was performing neutron noise measurements on subcritical configurations from deeply subcritical to nearly delayed critical. Multiple detector systems were used to perform these measurements, such as a 3 He multiplicity detector called the Neutron Multiplicity Array Detector (NoMAD) and a liquid scintillator system called the Rossi-α Measurement Rapid Organic Discriminating Detector (RAM-RODD). Also included were a scintillator system from the University of Michigan and a set of small 3He tubes that have previously been used to measure Rossi-α values on near-critical systems. The focus of this paper will be a comparison of prospective analysis methods for the NoMAD measurements. Previous subcritical measurements at the National Criticality Experiments Research Center (NCERC) submitted to the International Criticality Safety Benchmark Evaluation Project (ICSBEP) used the Hage-Cifarelli formalism of the Feynman Variance-to-Mean method. This relies on the time correlations of neutron detections to infer the spontaneous fission rate and neutron multiplication of a system through binning the time tagged detections and analyzing resulting histograms of the numbers of counts. However, there are other neutron noise methods that rely on similar processes, such as the Hansen-Dowdy formalism which uses a slightly different methodology to extract multiplication from the neutron multiplicity counting moments. Comparisons can be made between these experimental results and those obtained through simulations to validate or identify deficiencies in analysis, detection methods, or the underlying nuclear data. Different time gating strategies and their effects on count rate uncertainties are also investigated.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Equivalent Fundamental-Mode Source Simulations for Spherical Uranium and Plutonium Systems [Abstract]

The equivalent fundamental-mode source refers to a “source” which is identically distributed in space, energy, and angle as that of a fundamental-mode fission source distribution. It has previously been shown that the system fixed source multiplication ($M_{fs}$) relates to the effective multiplication factor ($\kappa_{eff}$) as $M_{fs} = \frac{g^*}{1-k_{eff}}$ The term $\mathcal{g}$* therefore relates the system source distribution to the system equivalent fundamental-mode source. As previously shown, the $\mathcal{g}$* term is approximately 1 for deeply subcritical systems and then diverges as the system multiplication increases. For a system with a point source located in the center of an assembly (such a sphere), $\mathcal{g}$* will be greater than 1; this happens because there is a higher probability of induced fission when all of the starter neutrons originate from the center of the sphere. For a uniform source, $\mathcal{g}$* is less than 1, but does not diverge from 1 as dramatically as seen by a point source. One reason that $\mathcal{g}$* is an important parameter is that it is used in measurement methods to infer reactor kinetics parameters ($β_{eff}$ being one example). This work will discuss multiple ways to simulate $\mathcal{g}$* using MCNP®6.2, which include use of traditional methods versus a single input file method that was recently published. A discussion related to methods to simulate $M_{fs}$ will be presented. Spherical systems of Highly Enriched Uranium (HEU) will be compared with previous works. In addition, results of plutonium including multiple reflector materials will be investigated. Simulated systems will include both parametric studies as well as configurations used in recent experiments performed at the National Criticality Experiments Research Center (NCERC). These studies will include subtleties associated with system geometry that have not been previously shown. Last, this work will investigate the relationship between $\mathcal{g}$* and reactor kinetics parameters (such as $β_{eff}$).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Preliminary RAM-RODD results for the MUSiC subcritical configurations

The Measurement of Uranium Subcritical and Critical (MUSiC) was performed at the DOE’s National Criticality Experiments Research Center (NCERC) located in the Nevada National Security Site (NNSS). The measurement utilized the Rocky Flats shells to perform benchmark measurements of similar highly enriched uranium (HEU) systems that span a wide range of reactivities. The Rocky Flats (RF) shells are 93.16% U-235 enriched metal hemishells that can be stacked concentrically. Ten configurations were measured with effective multiplication factors spanning between deeply subcritical (~ 0.64) through delayed critical. Details of the measured configurations are listed in Table 1. This unique set of measurements with its large span of reactivies is being used to determine the range over which neutron noise techniques such as Feynman variance-to-mean, Rossi-alpha, and pulsed neutron source techniques can be accurately employed for a bare HEU system. The results of the measurements will be published as a benchmark in The International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. The results will support the growing amount of subcritical benchmark data, such as the SCRaP measurements, that is available to the community. The measurements were performed using several different detector systems for the purposes of cross-validation and obtaining detector independent results. Four detector systems were deployed, three by the NCERC team and one from the University of Michigan. The detector systems included a Neutron Multiplicity Array Detector (NoMAD) system (similar to the MC-15), four small volume 0.635 cm (Ø) × 7.59 cm 3 He detectors (ideal for measuring prompt neutron decay constants due to their fast recovery speed), the Rossi Alpha Measurements – Rapid Organic (n, γ) Discrimination Detector (RAM-RODD), and the Organic Scintillator Array (OSCAR). RAM-RODD is an array of eight 5.08 cm (Ø) × 5.08 cm EJ-309 organic scintillator detectors. OSCAR is a University of Michigan system and is an array of twelve 5.08 cm (Ø) × 5.08 cm stilbene detectors. Details of measurements performed with OSCAR will be discussed in a separate talk. The focus of this work is preliminary results obtained by RAM-RODD for the 8 subcritical configurations. Additional details on the measurements and on the setup and deployment of RAM-RODD will be discussed. Preliminary neutron noise analysis results including Rossi-alpha and Feynman-alpha will also be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wing analysis using a transonic potential flow computational method

The ability of the method to compute wing transonic performance was determined by comparing computed results with both experimental data and results computed by other theoretical procedures. Both pressure distributions and aerodynamic forces were evaluated. Comparisons indicated that the method is a significant improvement in transonic wing analysis capability. In particular, the computational method generally calculated the correct development of three-dimensional pressure distributions from subcritical to transonic conditions. Complicated, multiple shocked flows observed experimentally were reproduced computationally. The ability to identify the effects of design modifications was demonstrated both in terms of pressure distributions and shock drag characteristics.

Henne, P. A.↗

Multiple Equilibria Associated with Response of the ITCZ to Seasonal SST Forcing

Supported by numerical experiment results, the abrupt change of the location of the intertropical convergence zone (ITCZ), from the equatorial trough flow regime to the monsoon trough flow regime is interpreted as a subcritical instability. The existence of these multiple quasi-equilibria is due to the balance of two "forces" on the ITCZ: one toward the equator, due to the earth's rotation, has a nonlinear latitudinal dependence; and the other toward the latitude of the sea surface (or ground) temperature peak has a relatively linear latitudinal dependence. This work pivots on the finding that the ITCZ and Hadley circulation can still exist without the pole-to-equator gradient of radiative-convective equilibrium temperature.

Chao, Winston C.↗

Nuclear Data Libraries Sensitivity Studies for ORSA Using SCALE

Subcritical assemblies offer valuable training capabilities in nuclear criticality safety (NCS) for individuals handling fissile material. At Oak Ridge National Laboratory(ORNL), the Oak Ridge Subcritical Assembly (ORSA), a new experimental facility, is being established to provide hands-on training for the Nuclear Criticality Safety Program (NCSP).It is essential to accurately determine the neutron multiplication factor (keff) to ensure that ORSA remains subcritical and safe during operations. This study investigated the sensitivity of keff to variations across Evaluated Nuclear Data File (ENDF/B) libraries, consisting of ENDF/B-VII.1, ENDF/B-VIII.0, and ENDF/B-VIII.1. The analysis was conducted using the CSAS6 sequence in the SCALE-6.3 code system. Individual isotopes in the ORSA model were replaced one at a time with ENDF/B-VII.1 as the base library and changing to ENDF/B-VIII.0or ENDF/B-VIII.1. The results demonstrated that the changes in keffof the nuclides associated with the ORSA model were mostly within the uncertainty of the base model (~24 pcm), except for primary nuclides like Uranium-235and H-poly with few other nuclides. The relative delta keff values of Uranium-235 and H-poly, expressed in pcm, were +280 and -212 in ENDF/B-VIII.0 and +332 and -275 in ENDF/B-VIII.1, respectively, which were notable changes in reactivity. These results demonstrated that ORSA was largely insensitive to variations across these nuclear data libraries.

Hong, Evan [North Carolina State University]↗

Preliminary NoMAD Results of the MUSIC Experiment

The Measurement of Uranium Subcritical and Critical (MUSiC) experiment was carried out from December 2020 through April 2021 at the National Criticality Experiments Research Center (NCERC). This measurement campaign featured bare configurations of the Rocky Flats highly-enriched uranium (HEU) shells, with each configuration having different numbers of these shells. The goal of the experiment was to test multiple neutron multiplicity detectors and measurement methods for a large range of neutron multiplication values, to see when the combination of detectors and methods break down as the configurations reach the delayed supercritical window. Adding subcritical integral benchmarks gives additional validation to nuclear data. These benchmarks provide additional parameters against which to validate the data. While critical benchmarks have just a single value, $K_{eff}$ , subcritical benchmarks can be used to infer multiple parameters. As an example, recent subcritical benchmarks utilizing the Hage-Cifarelli formalism have three quantities of interest ($R_{1}$, $R_{2}$, and $M_{L}$). This gives nuclear data evaluators additional data to use when performing their evaluations, and allows for these benchmarks to be useful for additional types of nuclear data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MC-Lite: Development of a new lightweight multiplicity counter

This report details the development of a neutron multiplicity counter based on lithium doped plastic scintillators. This system has the capability to measure and discriminate fast neutrons, thermal neutrons, and gamma-rays allowing for multi-particle correlations in one device. The system was built and tested at Lawrence Livermore National Laboratory with Cf-252 in both bare configurations and surrounded by polyethylene and compared against the MC-15 multiplicity counter. Additionally, the detector was also placed outside of a subcritical assembly and demonstrated the ability to use correlated gamma-rays as a probe on the multiplication of the item.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

End-to-End Simulations of a 3.4-Meter Detector Wall for Neutron-Diagnosed Subcritical Experiments

The Nevada National Security Site, together with Los Alamos National Laboratory and Lawrence Livermore National Laboratory, is developing a novel diagnostic to measure the reactivity of subcritical experiments. This capability is known as neutron-diagnosed subcritical experiments. The decay of the fission gamma rays from the neutron-interrogated subcritical experiment is measured as a function of time with a large (~3-meter diameter) detector wall consisting of 151 individual detector pixels. The data from this current mode measurement inform the neutron multiplication factor, keff, and thus the relative reactivity of the subcritical experiment. The Nevada National Security Site developed the Gamma Array Simulation Toolkit initially to help inform the design of the individual detector pixels and the 3.4-meter diameter detector wall to be fielded as part of neutron-diagnosed subcritical experiments. This toolkit is now being used to simulate and predict the performance of the final design of the individual detector pixels and the aggregate detector wall. Additionally, key detector characteristics evaluated from these simulations include impulse response, pulse height spectrum, number of photoelectrons per MeV, detector efficiency, and cross talk between detector pixels. Collectively, the results of these simulations inform how well the fission gamma ray die-off distribution from a neutron-diagnosed subcritical experiment measurement can be resolved. This is critical to determining the relative reactivity of the experiment. Furthermore, the Gamma Array Simulation Toolkit can be used to aid in the analysis of the experimental data from a neutron-diagnosed subcritical experiment measurement once the simulation has been benchmarked.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

End-to-End Simulations of a 3.4-Meter Detector Wall for Neutron-Diagnosed Subcritical Experiments

The Nevada National Security Site, together with Los Alamos National Laboratory and Lawrence Livermore National Laboratory, is developing a novel diagnostic to measure the reactivity of subcritical experiments. This capability is known as neutron-diagnosed subcritical experiments. The decay of the fission gamma rays from the neutron-interrogated subcritical experiment is measured as a function of time with a large (~3-meter diameter) detector wall consisting of 151 individual detector pixels. The data from this current mode measurement inform the neutron multiplication factor, keff, and thus the relative reactivity of the subcritical experiment. The Nevada National Security Site developed the Gamma Array Simulation Toolkit initially to help inform the design of the individual detector pixels and the 3.4-meter diameter detector wall to be fielded as part of neutron-diagnosed subcritical experiments. This toolkit is now being used to simulate and predict the performance of the final design of the individual detector pixels and the aggregate detector wall. Key detector characteristics evaluated from these simulations include impulse response, pulse height spectrum, number of photoelectrons per MeV, detector efficiency, and cross talk between detector pixels. Collectively, the results of these simulations inform how well the fission gamma ray die-off distribution from a neutron-diagnosed subcritical experiment measurement can be resolved. This is critical to determining the relative reactivity of the experiment. Furthermore, the Gamma Array Simulation Toolkit can be used to aid in the analysis of the experimental data from a neutrondiagnosed subcritical experiment measurement once the simulation has been benchmarked.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗