Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “stroboscope”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Noncontact torque measurement using stroboscopic techniques

Noncontact torquemeter measures torsional deflection of rotating shaft and results are viewed on vernier scale. Magnitude of torque must be calculated from measured deflection. Device has no electric connections with the rotating member and is easy to use.

Leonard, W. H.↗

A stroboscopic technique for using CCD cameras in flow visualization systems for continuous viewing and stop action photography

A technique for synchronizing a pulse light source to charge coupled device cameras is presented. The technique permits the use of pulse light sources for continuous as well as stop action flow visualization. The technique has eliminated the need to provide separate lighting systems at facilities requiring continuous and stop action viewing or photography.

Franke, John M.↗

A Countermeasure for Space Motion Sickness

Overall, the results obtained in both the U.S. and the Russian space programs indicate that most space crews will experience some symptoms of motion sickness (MS) causing significant impact on the operational objectives that must be accomplished to assure mission success. At this time the primary countermeasure for MS requires the administration of Promethazine. Promethazine is not a benign drug, and is most frequently administered just prior to the sleep cycle to prevent its side effects from further compromising mission objectives. Clearly other countermeasures for SMS must be developed. Currently the primary focus is on two different technologies: (1) developing new and different pharmacological compounds with less significant side effects, (2) preflight training. The primary problem with all of these methods for controlling MS is time. New drugs that may be beneficial are years from testing and development, and preflight training requires a significant investment of crew time during an already intensive pre-launch schedule. Granted, motion sickness symptoms can be minimized with either of the two methods detailed above, however, it may be possible to develop a countermeasure that does not require either extensive adaptation time or exposure to motion sickness. Approximately 25 years ago Professor Geoffrey Melvill Jones presented his work on adaptation of the vestibuloocular reflex (VOR) using optically reversed vision (left-right prisms) during head rotations in the horizontal plane. It was of no surprise that most subjects experienced motion sickness while wearing the optically reversing prisms. However, a serendipitous finding emerged during this research showing that the same subjects did not experience motion sickness symptoms when wearing the reversing prisms under stroboscopic illumination. The mechanism, by which this side-effect was believed to have occurred, is not clearly understood. However, the fact that no motion sickness was ever noted, suggests the possibility of producing functionally useful adaptation during space flight without the penalty of disabling motion sickness by controlling the rate of the adaptive process by means of an appropriate stroboscopically presented environment. After several recent meetings with Professor Melvill Jones, we were encouraged to repeat the motion sickness portions of his and Mandl's 1981 stroboscopic experiment. In conducting this experiment we used a randomized cross-over design where subjects were randomly assigned to either a stroboscopic flash or no strobe for their first exposure in the experimental design. Twenty subjects (19 subjects completed the study) read a short passage from Treasure Island mounted on the wall approximately 1 m from their eyes while wearing left-right reversing prisms. The strobe on time of 3 microseconds and flash frequency of 4 Hz was set to equal that used in the original study. Motion sickness was scored using a modified Miller and Graybiel scale that we constructed to include symptoms that may be elicited under conditions where reversing prisms are worn. On this scale a score of 5 represented Malaise IIa (mild motion sickness) and a score of 8 or above is approaching frank sickness. Symptoms were tracked and recorded every 5 min during the task. Testing was limited to 30 min unless the subject had reached the MIIa score, at which time the test was terminated. Performance under stroboscopic illumination was significantly better than when the subjects read under normal room illumination while wearing the left-right reversing prisms. Based on these results we developed a goggle system using LCD material that can be strobed. To evaluate the effectiveness of stroboscopic goggles we tested an additional 9 subjects in addition to retesting 10 used in the stroboscopic pilot study described above. These 19 subjects wore a pair of strobing LCD goggles that could be cycled at 4 Hz. These subjects wore the goggles while also wearing left-right reversg prisms. Results while wearing the goggles showed that none of the 19 subjects scored at the MIIa level on the motion sickness rating scale. When the goggles did not flash (no strobe), 11 of the 19 developed symptoms above the MIIa criteria. As a countermeasure the goggles seem to be effective, even with an on time of 10 msec (time the goggles are clear). We have also collected anecdotal data, from our personnel in the Neuroscience Laboratory at the Johnson Space Center, suggesting that the goggles may effective in preventing carsickness.

Reschke, M. F.↗

Self-synchronizing Schlieren photography and interferometry for the visualization of unsteady transonic flows

The use of self synchronizing stroboscopic Schlieren and laser interferometer systems to obtain quantitative space time measurements of distinguished flow surfaces, steakline patterns, and the density field of two dimensional flows that exhibit a periodic content was investigated. A large field single path stroboscopic Schlieren system was designed, constructed and successfully applied to visualize four periodic flows: near wake behind an oscillating airfoil; edge tone sound generation; 2-D planar wall jet; and axisymmetric pulsed sonic jet. This visualization technique provides an effective means of studying quasi-periodic flows in real time. The image on the viewing screen is a spatial signal average of the coherent periodic motion rather than a single realization, the high speed motion of a quasi-periodic flow can be reconstructed by recording photographs of the flow at different fixed time delays in one cycle. The preliminary design and construction of a self synchronizing stroboscopic laser interferometer with a modified Mach-Zehnder optical system is also reported.

Kadlec, R.↗

Window of visibility - A psychophysical theory of fidelity in time-sampled visual motion displays

A film of an object in motion presents on the screen a sequence of static views, while the human observer sees the object moving smoothly across the screen. Questions related to the perceptual identity of continuous and stroboscopic displays are examined. Time-sampled moving images are considered along with the contrast distribution of continuous motion, the contrast distribution of stroboscopic motion, the frequency spectrum of continuous motion, the frequency spectrum of stroboscopic motion, the approximation of the limits of human visual sensitivity to spatial and temporal frequencies by a window of visibility, the critical sampling frequency, the contrast distribution of staircase motion and the frequency spectrum of this motion, and the spatial dependence of the critical sampling frequency. Attention is given to apparent motion, models of motion, image recording, and computer-generated imagery.

Watson, A. B.↗

Time Slicing of Neutrino Fluxes in Oscillation Experiments at Fermilab

Long and short baseline neutrino oscillation experiments, such as DUNE, SBND, demand high precision in reducing systematic errors, particularly those related to neutrino-nucleus interaction cross-sections. The stroboscopic approach offers a method to capture distinct neutrino energy spectra, aiding in the separation of flux and cross-section uncertainties. This report outlines the creation of short proton bunch lengths and the transport of a narrow beam down the Booster Neutrino Beamline, essential steps for the successful implementation of the stroboscopic approach.

43 PARTICLE ACCELERATORS↗

Extreme Longitudinal Compression of Optimized Beams for MEV Ultrafast Electron Diffraction (Final Technical Report)

We worked out the design of a high repetition rate MeV energy ultrafast electron diffraction instrument based on the existing Cornell photoinjector, which can readily be applied to the presented findings. This example is a blueprint of other similarly arranged UED setups. Using particle tracking simulations in conjunction with multiobjective genetic algorithm optimization, we explored the smallest bunch lengths, emittance, and probe spot sizes achievable. As two limits, we defined stroboscopic conditions (with single electrons per pulse) and operation with 10 5 electrons per bunch which may be suitable for single-shot diffraction images. In the stroboscopic case, the flexibility provided by the many cavity bunching and acceleration allows for longitudinal phase space linearization without a higher harmonic field, providing sub-fs bunch lengths at the sample. Given low emittance photoemission conditions, these small bunch lengths can be maintained with probe transverse sizes at the single micron (1 μm) scale and below. In the case of 10 5 electrons per pulse, we simulated state-of-the-art 5D brightness conditions: rms bunch lengths of 10 fs with 3-nm normalized emittances, while permitting repetition rates as high as 1.3 GHz. We showed that in conjunction with collimating apertures, a novel focusing scheme achieves very high-quality emittance compensation for the central core of the beam composing 40% of particles, for a resulting beam size of 5 μm (rms). Finally, to aid in the design of new SRF-based ultrafast electron diffraction machines, we simulated the trade-off between the number of cavities used and achievable bunch length and emittance. In the longitudinal dimension, we made use of the fact that MeV UED requires much lower energy than the 15-MeV maxi mum energy of Cornell’s CBETA injector, and we may therefore use several of the SRF cavities for bunch length compression. In practice, we used a genetic optimization algorithm to choose the phases and amplitudes of the cavities appropriately for optimal bunching. In the zero space charge case, we found that bunching and acceleration are distributed across the six cavities in a way that produces a linearizing effect. And we showed that the ultimate bunch length can be limited by time-of-flight differences arising from transverse size and transverse momentum spread. The space charge code developed and used for this development is now permanent part of the Bmad accelerator simulation code and has already contributed to other developments, e.g., for the EIC electron cooler design.

43 PARTICLE ACCELERATORS↗

Measuring Mirror Tilt With High Accuracy

Stroboscopic technique freezes mirror motion so displacements can be measured. Improved autocollimator accurately measures angular tilt of plane mirrors in rotational or reciprocating motion. Device is conventional autocollimator in which steady light source is replaced by stroboscope synchronized with mirror motion. It is accurate to 1 second of arc.

Magner, T. J.↗

Simulation of water vapor condensation on LOX droplet surface using liquid nitrogen

The formation of ice or water layers on liquid oxygen (LOX) droplets in the Space Shuttle Main Engine (SSME) environment was investigated. Formulation of such ice/water layers is indicated by phase-equilibrium considerations under conditions of high partial pressure of water vapor (steam) and low LOX droplet temperature prevailing in the SSME preburner or main chamber. An experimental investigation was begun using liquid nitrogen as a LOX simulant. A monodisperse liquid nitrogen droplet generator was developed which uses an acoustic driver to force the stream of liquid emerging from a capillary tube to break up into a stream of regularly space uniformly sized spherical droplets. The atmospheric pressure liquid nitrogen in the droplet generator reservoir was cooled below its boiling point to prevent two phase flow from occurring in the capillary tube. An existing steam chamber was modified for injection of liquid nitrogen droplets into atmospheric pressure superheated steam. The droplets were imaged using a stroboscopic video system and a laser shadowgraphy system. Several tests were conducted in which liquid nitrogen droplets were injected into the steam chamber. Under conditions of periodic droplet formation, images of 600 micron diameter liquid nitrogen droplets were obtained with the stroboscopic video systems.

Powell, Eugene A.↗

Dynamic Visual Acuity and Landing Sickness in Crewmembers Returning from Long-Duration Spaceflight

Long-term exposure to microgravity causes sensorimotor adaptations that result in functional deficits upon returning to a gravitational environment. At landing the vestibular system and the central nervous system, responsible for coordinating head and eye movements, are adapted to microgravity and must re-adapt to the gravitational environment. This re-adaptation causes decrements in gaze control and dynamic visual acuity, with astronauts reporting oscillopsia and blurred vision. Dynamic visual acuity (DVA) is assessed using an oscillating chair developed in the Neuroscience Laboratory at JSC. This chair is lightweight and easily portable for quick deployment in the field. The base of the chair is spring-loaded and allows for manual oscillation of the subject. Using a metronome, the chair is vertically oscillated plus or minus 2 cm at 2 Hz by an operator, to simulate walking. While the subject is being oscillated, they are asked to discern the direction of Landolt-C optotypes of varying sizes and record their direction using a gamepad. The visual acuity thresholds are determined using an algorithm that alters the size of the optotype based on the previous response of the subject using a forced-choice best parameter estimation that is able to rapidly converge on the threshold value. Visual acuity thresholds were determined both for static (seated) and dynamic (oscillating) conditions. Dynamic visual acuity is defined as the difference between the dynamic and static conditions. Dynamic visual acuity measures will be taken prior to flight (typically L-180, L-90, and L-60) and up to eight times after landing, including up to 3 times on R plus 0. Follow up measurements will be taken at R plus 1 (approximately 36 hours after landing). Long-duration International Space Station crewmembers will be tested once at the refueling stop in Europe and once again upon return to Johnson Space Center. In addition to DVA, subjective ratings of motion sickness will be recorded throughout the testing. Using the chair as a portable and reliable way to test DVA, we aim to test returning astronauts to assess the amount of retinal slip that they experience. By comparing these measurements to their motion sickness scores (using a scale of 1 to 20 where 20 is vomiting), we will correlate the amount of retinal slip to the level of motion sickness experienced. In addition to testing this in returning astronauts, we will perform ground-based studies to determine the effectiveness of stroboscopic goggles in reducing retinal slip and improving DVA. Finally, we will employ stroboscopic goggles in the field to astronauts experiencing high levels of motion sickness to minimize retinal slip and reduce their symptoms.

Rosenberg, M.J.F↗

New perspectives on materials and device dynamics using time-resolved full-field diffraction X-ray imaging

Understanding how materials evolve during synthesis, processing, or device operation requires experimental access to structural dynamics across wide ranges of length and time scales, often in bulk samples or even within packaged devices. Time-resolved full-field diffraction X-ray microscopy has recently emerged as a powerful way to meet this need by combining the penetration and structural sensitivity of X-ray diffraction with objective-lens-based magnification, sensitive high-resolution X-ray imaging detectors, and pump-probe and real-time imaging strategies. Advances in full-field X-ray diffraction microscopy, often termed dark-field X-ray microscopy (DFXM), enable simultaneous imaging of extended fields of view while retaining crystallographic selectivity. Time-resolved DFXM promises to enable advances in materials processing and dynamics, electrochemical and photochemical processes, and the design of electronic devices. This Perspective summarizes the key instrumental concepts that define the performance of these methods, including the choice of imaging optics, detector considerations, and the impact of source time structure at synchrotron light sources and X-ray free-electron lasers (XFELs). We discuss the simultaneous use of complementary imaging modes that are increasingly used in practice. The early demonstrations of the potential of time-resolved DFXM include real-time defect and grain-boundary dynamics during metal annealing, stroboscopic imaging of functional devices with high strain sensitivity, and ultrafast pump-probe implementations at XFELs that directly visualize acoustic-wave propagation and energy dissipation in bulk crystals.

Dark-field X-ray microscopy↗

Flicker: A review of temporal light modulation stimulus, responses, and measures

Flicker has been an important lighting system consideration for over a century. More precise terms are temporal light modulation (TLM) as the stimulus, and responses to TLM as the unwanted visual, cognitive, or physiological consequences. As lighting technology evolved, different forms of TLM emerged, and so did responses to them. Today, some LED systems – encompassing the LED, driver, and control – can result in TLM causing severe unwanted effects, while other LED systems produce no unwanted effects at all. LED systems can deliver a much wider range of luminous waveforms than conventional lighting systems, some exhibiting very high modulation depths. More than any light source before, they can elicit perceptions of the phantom array. Direct flicker effects at modulation frequencies less than about 80 Hz and the stroboscopic effect at frequencies greater than 80 Hz are fairly well understood, but the phantom array effect needs more exploration and characterisation. This review focuses on the technology and research history that led to current metrics for quantifying TLM and human responses to TLM. Notably, visually impaired individuals may exhibit alterations in their response to TLM, but such a discussion is beyond the intent of this review. Thus, the focus is on individuals with normal visual function.

60 APPLIED LIFE SCIENCES↗

Predictable Patterns in Planetary Transit Timing Variations and Transit Duration Variations Due to Exomoons

We present new ways to identify single and multiple moons around extrasolar planets using planetary transit timing variations (TTVs) and transit duration variations (TDVs). For planets with one moon, measurements from successive transits exhibit a hitherto undescribed pattern in the TTV-TDV diagram, originating from the stroboscopic sampling of the planet's orbit around the planet-moon barycenter. This pattern is fully determined and analytically predictable after three consecutive transits. The more measurements become available, the more the TTV-TDV diagram approaches an ellipse. For planets with multiple moons in orbital mean motion resonance (MMR), like the Galilean moon system, the pattern is much more complex and addressed numerically in this report. Exomoons in MMR can also form closed, predictable TTV-TDV figures, as long as the drift of the moons' pericenters is suciently slow.We find that MMR exomoons produce loops in the TTV-TDV diagram and that the number of these loops is equal to the order of the MMR, or the largest integer in the MMR ratio.We use a Bayesian model and Monte Carlo simulations to test the discoverability of exomoons using TTV-TDV diagrams with current and near-future technology. In a blind test, two of us (BP, DA) successfully retrieved a large moon from simulated TTV-TDV by co-authors MH and RH, which resembled data from a known Kepler planet candidate. Single exomoons with a 10 percent moon-to-planet mass ratio, like to Pluto-Charon binary, can be detectable in the archival data of the Kepler primary mission. Multi-exomoon systems, however, require either larger telescopes or brighter target stars. Complementary detection methods invoking a moon's own photometric transit or its orbital sampling effect can be used for validation or falsification. A combination of TESS, CHEOPS, and PLATO data would offer a compelling opportunity for an exomoon discovery around a bright star.

stroboscopic sampling↗

Optimizing qubit control pulses for state preparation

In the burgeoning field of quantum computing, the precise design and optimization of quantum pulses are essential for enhancing qubit operation fidelity. This study focuses on refining the pulse engineering techniques for superconducting qubits, employing a detailed analysis of square and Gaussian pulse envelopes under various approximation schemes. We evaluated the effects of coherent errors induced by naive pulse designs. Furthermore, we identified the sources of these errors in the Hamiltonian model’s approximation level. We mitigated these errors through adjustments to the external driving frequency and pulse durations, thus implementing a pulse scheme with stroboscopic error reduction. Our results demonstrate that these refined pulse strategies improve performance and reduce coherent errors. Moreover, the techniques developed herein are applicable across different quantum architectures, such as ion-trap, atomic, and photonic systems.

Chirp modulation↗

High-resolution high-throughput spatiotemporal strain imaging reveals loss mechanisms in a surface acoustic wave device

Surface acoustic wave devices are key components for processing radio frequency signals in wireless communication because these devices offer simultaneously high performance, compact size and low cost. The optimization of the device structure requires a quantitative understanding of energy conversion and loss mechanisms. Here we use stroboscopic full-field diffraction x-ray microscopy to reveal an unanticipated acoustic loss in a prototypical one-port resonator device. A non-uniform acoustic excitation in the active area was responsible for the substantial end and side leakages observed at the design frequency. Quantitative analysis of the strain amplitude using a wave decomposition method allowed the determination of several key device parameters. This high-resolution high-throughput spatiotemporal strain imaging technique is more generally applicable to the study of dynamic strain modulation in nanoscale acoustic, electronic, optical and quantum devices. The high sensitivity allows precise measurement of the strain modulation with picometer-scale amplitude.

Zhou, Tao [ESRF - The European Synchrotron, Grenob↗

Long-lived period-doubled edge modes of interacting and disorder-free Floquet spin chains

Floquet spin chains have been a venue for understanding topological states of matter that are qualitatively different from their static counterparts by, for example, hosting π edge modes that show stable period-doubled dynamics. However the stability of these edge modes to interactions has traditionally required the system to be many-body localized in order to suppress heating. In contrast, here we show that even in the absence of disorder, and in the presence of bulk heating, π edge modes are long lived. Their lifetime is extracted from exact diagonalization and is found to be non-perturbative in the interaction strength. A tunneling estimate for the lifetime is obtained by mapping the stroboscopic time-evolution to dynamics of a single particle in Krylov subspace. In this subspace, the π edge mode manifests as the quasi-stable edge mode of an inhomogeneous Su-Schrieffer-Heeger model whose dimerization vanishes in the bulk of the Krylov chain.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Laser-driven ultrafast transmission electron microscopy

Recent advances in lasers and electron optics technology have allowed transmission electron microscopes to achieve high spatial and temporal resolution, making them capable of tracking atoms, charges and spin motions down to the attosecond and nanometre scales. This Primer discusses the most common and practical experimental implementation of time-resolved transmission electron microscopy and the stroboscopic mode for evaluating ultrafast reversible dynamics. An in-depth discussion of photo-induced near-field electron microscopy, a technique unique to laser-assisted electron microscopy, is also provided, covering its prospective applications in the study of coherent phenomena in quantum materials. The experimental strategies and limitations in investigating the structural dynamics of materials and nanostructures by imaging, diffraction and spectroscopy are also described in detail, with a direct comparison with more conventional and established techniques. Here, we provide key information for new researchers who intend to use ultrafast transmission electron microscopy to address new challenges in specific materials science, condensed matter and nanophotonics.

Transmission electron microscopy↗