Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “storing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Measurements of store forces and moments and cavity pressures for a generic store in and near a box cavity at subsonic and transonic speeds

An experimental force and moment study was conducted in the Langley 8-Foot Transonic Pressure Tunnel for a generic store in and near rectangular box cavities contained in a flat-plate configuration at subsonic and transonic speeds. Surface pressures were measured inside the cavities and on the flat plate. The length-to-height ratios were 5.42, 6.25, 10.83, and 12.50. The corresponding width-to-height ratios were 2.00, 2.00, 4.00, and 4.00. The free-stream Mach number range was from 0.20 to 0.95. Surface pressure measurements inside the cavities indicated that the flow fields for the shallow cavities were either closed or transitional near the transitional/closed boundary. For the deep cavities, the flow fields were either open or near the open/transitional boundary. The presence of the store did not change the type of flow field and had only small effects on the pressure distributions. For transitional or open transitional flow fields, increasing the free-stream Mach number resulted in large reductions in pitching-moment coefficient. Values of pitching-moment coefficient were always much greater for closed flow fields than for open flow fields.

Stallings, Robert L., Jr.↗

“Wine-Dark Sea” in an Organic Flow Battery: Storing Negative Charge in 2,1,3-Benzothiadiazole Radicals Leads to Improved Cyclability

Redox-active organic materials (ROMs) have shown great promise for redox flow battery applications but generally encounter limited cycling efficiency and stability at relevant redox material concentrations in nonaqueous systems. Here we report a new heterocyclic organic anolyte molecule, 2,1,3-benzothiadiazole, that has high solubility, a low redox potential, and fast electrochemical kinetics. Coupling it with a benchmark catholyte ROM, the nonaqueous organic flow battery demonstrated significant improvement in cyclable redox material concentrations and cell efficiencies compared to the state-of-the-art nonaqueous systems. Especially, this system produced exceeding cyclability with relatively stable efficiencies and capacities at high ROM concentrations (>0.5 M), which is ascribed to the highly delocalized charge densities in the radical anions of 2,1,3-benzothiadiazole, leading to good chemical stability. As a result, this material development represents significant progress toward promising next-generation energy storage.

25 ENERGY STORAGE↗

Extreme Compression for Large Scale Data Store

For the last 5 years Accelogic pioneered and perfected a radically new theory of numerical computing codenamed “Compressive Computing”, which has an extremely profound impact on real-world computer science [1]. At the core of this new theory is the discovery of one of its fundamental theorems which states that, under very general conditions, the vast majority (typically between 70% and 80%) of the bits used in modern large-scale numerical computations are absolutely irrelevant for the accuracy of the end result. This theory of Compressive Computing provides mechanisms able to identify (with high intelligence and surgical accuracy) the number of bits (i.e., the precision) that can be used to represent numbers without affecting the substance of the end results, as they are computed and vary in real time. The bottom line outcome would be to provide a state-of-the-art compression algorithm that surpasses those currently available in the ROOT framework, with the purpose of enabling substantial economic and operational gains (including speedup) for High Energy and Nuclear Physics data storage/analysis. In our initial studies, a factor of nearly x4 (3.9) compression was achieved with RHIC/STAR data where ROOT compression managed only x1.4.In this contribution, we will present our concepts of “functionally lossless compression”, have a glance at examples and achievements in other communities, present the results and outcome of our current, ongoing R&D, as well as present a high-level view of our plan to move forward with a ROOT implementation that would deliver a basic solution readily integrated into HENP applications. As a collaboration of experimental scientists, private industry, and the ROOT Team, our aim is to capitalize on the substantial success delivered by the initial effort and produce a robust technology properly packaged as an open-source tool that could be used by virtually every experiment around the world as means for improving data management and accessibility.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Healthy Zero Energy Buildings (HZEB) Program - Cross-Sectional Study of Contaminant Levels, Source, Strengths, and Ventilation Rates in Retail Stores

This field study measured ventilation rates and indoor air quality parameters in 21 visits to retail stores in California. The data was collected to guide the development of new, science-based commercial building ventilation rate standards that balance the dual objectives of increasing energy efficiency and maintaining acceptable indoor air quality. Data collection occurred between September 2011 and March 2013. Three types of stores participated in this study: grocery stores, furniture/hardware stores, and apparel stores. Ventilation rates and indoor air contaminant concentrations were measured on a weekday, typically between 9 am and 6 pm. Ventilation rates measured using a tracer gas decay method exceeded the minimum requirement of California’s Title 24 Standard in all but one store. Even though there was adequate ventilation according to Title 24, concentrations of formaldehyde, acetaldehyde, and acrolein exceeded the most stringent chronic health guidelines. Other indoor air contaminants measured included carbon dioxide (CO{sub 2}), carbon monoxide (CO), ozone (O{sub 3}), and particulate matter (PM). Concentrations of CO{sub 2} were kept low by adequate ventilation, and were assumed low also because the sampling occurred on a weekday when retail stores were less busy. CO concentrations were also low. The indoor-outdoor ratios of O{sub 3} showed that the first-order loss rate may vary by store trade types and also by ventilation mode (mechanical versus natural). Analysis of fine and ultrafine PM measurements showed that a substantial portion of the particle mass in grocery stores with cooking-related emissions was in particles less than 0.3 μm. Stores without cooking as an indoor source had PM size distributions that were more similar indoors and outdoors. The whole-building emission rates of volatile organic compounds (VOCs) and PM were estimated from the measured ventilation rates and indoor and outdoor contaminant concentrations. Mass balance models were then used to determine the ventilation rates, filtration strategies, or source reductions needed to maintain indoor contaminant concentrations below reference levels. Several scenarios of potential concern were considered: (i) formaldehyde levels in furniture/hardware stores, (ii) contaminants associated with cooking (e.g., PM, acrolein, and acetaldehyde) in grocery stores, and (iii) outdoor contaminants (e.g., PM and O{sub 3}) impacting stores that use natural ventilation. Estimated formaldehyde emission rates suggest that retail stores would need to ventilate at levels far exceeding the current Title 24 requirement to lower indoor concentrations below California’s stringent formaldehyde reference level. Given the high costs of providing ventilation but only modest chronic health benefit is expected, effective source control is an attractive alternative, as demonstrated by some retail stores in this study. Predictions showed that grocery stores need MERV 13 air filters, instead of MERV 8 filters that are more commonly used, to maintain indoor PM at levels that meet the chronic health standards for PM. Exposure to acrolein is a potential health concern in grocery stores, and should be addressed by increasing the use of kitchen range hoods or improving their contaminant removal efficiency. In stores that rely on natural ventilation, indoor PM can be a health concern if the stores are located in areas with high outdoor PM. This concern may be addressed by switching to mechanical ventilation when the outdoor air quality is poor, while continuing natural ventilation when outdoor air quality is good.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Aerodynamic Forces and Moments on a Large Ogive-Cylinder Store at Various Locations Below the Fuselage Center Line of a Swept-Wing Bomber Configuration at a Mach Number of 1.61

A supersonic wind-tunnel investigation on store interference has been conducted in the Langley 4- by 4-foot supersonic pressure tunnel at a Mach number of 1.61. Forces and moments were measured on a large ogive-cylinder store in the presence of a 45 deg swept-wing-fuselage bomber configuration for a number of store locations below the fuselage center line. Results of the investigation show that large variations of store lift, drag, and pitch occur with changes in store or airplane angle of attack, store vertical location, and store horizontal location. The variation of the store forces and moments with respect to the chordwise location of the wing plan form indicates that the wing is a large factor in producing the interference loads on the store. Comparison of data for underfuselage and underwing store locations at an angle of attack of 0 deg showed maximum store drag interferences of similar magnitudes, but showed considerably smaller maximum interference on store lift an pitching moments for underfuselage store locations.

SUPERSONIC FLIGHT↗

Effect on Drag of Longitudinal Positioning of Half-Submerged and Pylon-Mounted Douglas Aircraft Stores on a Fuselage with and without Cavities between Mach Numbers 0.9 and 1.8

The effect on drag of positioning symmetrically mounted Douglas Aircraft Company, Inc. stores in pairs on a parabolic fuselage of fineness ratio 10.0 has been determined by flight tests of rocket-propelled, zero-lift models through a range of Mach number from 0.9 to 1.8. The stores were mounted in half-submerged positions and on pylons and were tested in three longitudinal locations on the fuselage with the forward position being located at the maximum diameter of the fuselage. The effects on drag of removing the half-submerged stores or extending them outward on pylons also was investigated by tests of models with half-submerged-store cavities on the fuselage. Two pylons differing in airfoil section and thickness were tested at the forward position of the stores on the fuselage with cavities. The half-submerged stores gave the smallest drag increments, which were approximately equal regardless of their respective longitudinal locations. Removing the half-submerged stores to expose the cavities increased the drag increments from two to three times. For the pylon-mounted stores, the store in the midposition had less drag than in the forward or rear positions at supersonic speeds. Adding the half-submerged-store cavities to the pylon-mounted-store configurations reduced the drag at the rear position between Mach numbers 0.95 and 1.50 and increased the drag at the midposition throughout the speed range. Changing from the 6-percent-thick flat pylon to the 10-percent-thick airfoil pylon increased the total drag slightly above Mach number 1.10. Good agreement was obtain& between the experimental and theoretical interference drag coefficients for the pylon-mounted stores (without fuselage cavities} in the three longitudinal locations tested at Mach numbers 1.2 and 1.5.

Hoffman, Sherwood↗

Drag measurements of blunt stores tangentially mounted on a flat plate at supersonic speeds

An investigation has been conducted in the Langley Unitary Plan Wind Tunnel to measure the drag of blunt stores (hemispherical noses and afterbodies) tangentially mounted in various arrays on a flat plate at nominal Mach numbers of 1.60, 1.90, 2.16,and 2.86 and at a nominal Reynolds number of 2X10 to the 6th power per foot. The arrays consisted of two and three stores mounted in lateral, tandem, or staggered arrangements. The relative position of the stores in the arrays was varied while the drag of only one store was measured to determine the effect of spacing on the store drag. Store-on-store interference was determined by comparing the drag of a single store with the drag of the store in an array. The results indicate virtually all arrangements and spacings which were tested had favorable store-on-store interference (drag reduction) across the Mach number range. Tabulated data, schlieren photographs, and shadowgraphs are included.

Wilcox, Floyd J., Jr.↗

Aerodynamic Loads on an External Store Adjacent to a 45 Degree Sweptback Wing at Mach Numbers from 0.70 to 1.96, Including an Evaluation of Techniques Used

Aerodynamic forces and moments have been obtained in the Langley 9- by 12-inch blowdown tunnel on an external store and on a 45 degree swept-back wing-body combination measured separately at Mach numbers from 0.70 to 1.96. The wing was cantilevered and had an aspect ratio of 4.0; the store was independently sting-mounted and had a Douglas Aircraft Co. (DAC) store shape. The angle of attack range was from -3 degrees to 12 degrees and the Reynolds number (based on wing mean aerodynamic chord) varied from 1.2 x10(6) to 1.7 x 10(6). Wing-body transonic forces and moments have been compared with data of a geometrically similar full-scale model tested in the Langley 16-foot and 8-foot transonic tunnels in order to aid in the evaluation of transonic-tunnel interference. The principal effect of the store, for the position tested, was that of delaying the wing-fuselage pitch-up tendency to higher angles of attack at Mach numbers from 0.70 to 0.90 in a manner similar to that of a wing chord extension. The most critical loading condition on the store was that due to side force, not only because the loads were of large magnitude but also because they were in the direction of least structural strength of the supporting pylon. These side loads were greatest at high angles of attack in the supersonic speed range. Removal of the supporting pylon (or increasing the gap between the store and wing) reduced the values of the variation of side-force coefficientwith angle of attack by about 50 percent at all test Mach numbers, indicating that important reductions in store side force may be realized by proper design or location of the necessary supporting pylon. A change of the store skew angle (nose inboard) was found to relieve the excessive store side loads throughout the Mach number range. It was also determined that the relative position of the fuselage nose to the store can appreciably affect the store side forces at supersonic speeds.

Guy, Lawrence D↗

Ordering of guarded and unguarded stores for no-sync I/O

A parallel computing system processes at least one store instruction. A first processor core issues a store instruction. A first queue, associated with the first processor core, stores the store instruction. A second queue, associated with a first local cache memory device of the first processor core, stores the store instruction. The first processor core updates first data in the first local cache memory device according to the store instruction. The third queue, associated with at least one shared cache memory device, stores the store instruction. The first processor core invalidates second data, associated with the store instruction, in the at least one shared cache memory. The first processor core invalidates third data, associated with the store instruction, in other local cache memory devices of other processor cores. The first processor core flushing only the first queue.

97 MATHEMATICS AND COMPUTING↗

Effect of conventional and square stores on the longitudinal aerodynamic characteristics of a fighter aircraft model at supersonic speeds

The effects of conventional and square stores on the longitudinal aerodynamic characteristics of a fighter aircraft configuration at Mach numbers of 1.6, 1.8, and 2.0 was investigated. Five conventional store configurations and six arrangements of a square store configuration were studied. All configurations of the stores produced small, positive increments in the pitching moment throughout the angle-of-attack range, but the configuration with area ruled wing tanks also had a slight decrease on stability at the higher angles of attack. There were some small changes in lift coefficient because of the addition of the stores, causing the drag increment to vary with the lift coefficient. As a result, there were corresponding changes in the increments of the maximum lift drag ratios. The store drag coefficient based on the cross sectional area of the stores ranged from a maximum of 1.1 for the configuration with three Maverick missiles to a minimum of about .040 for the two MK-84 bombs and the arrangements with four square stores touching or two square stores in tandem. Square stores located side by side yielded about 0.50 in the aft position compared to 0.74 in the forward position.

Monta, W. J.↗

Effect of stored strain energy heterogeneity on microstructure evolution of 90% cold rolled AISI 304L stainless steel during interrupted annealing treatment

Highlights: • Study of usefulness of stored strain energy distribution map of the material for variable temperature range. • Advantage of using stored strain energy distribution map • Variation observed in stored energy between isothermal annealing treatment and interrupted annealing treatment. - Abstract: This research work is an attempt to understand the effect of stored strain energy heterogeneity over macro-scale, induced during interrupted annealing treatment, on the micro structural evolution in a heavily cold rolled AISI 304L austenitic stainless steel. The cold rolled AISI 304L stainless steel (SS) samples were subjected to different annealing treatments. The microstructures obtained after each annealing treatment were characterized using optical and electron microscopy techniques. Further, an attempt was made to estimate the stored strain energy by a novel approach of micro hardness measurement both over small scale (area 3600 μm{sup 2}) and large scale (area ~0.25 mm{sup 2}). The stored strain energy was determined using hardness values. Using these data, spatial stored strain energy distribution contour maps were created. They were, in turn, used to characterize the local softening behavior both at micro and macro-scale levels after each interrupted annealing treatment. The results showed that, interrupted annealing treatment induces increased stored strain energy heterogeneity after each annealing interruptions. Also, it was possible to determine recrystallization kinetics of the material using stored strain energy map, which helps in designing annealing cycles for achieving ultrafine grained microstructure.

36 MATERIALS SCIENCE↗