Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “storage benchmark”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

On the role of Battery Energy Storage Systems in the day-ahead Contingency-Constrained Unit Commitment problem under renewable penetration

The integration of variable Renewable Energy Sources (vRES) to alleviate greenhouse gas emissions has introduced significant challenges for power systems operations. These challenges include high levels of uncertainty due to the intermittence associated with vRES and therefore impose the need to devise a reliable and cost-effective day-ahead unit commitment and power and reserves scheduling for real-time operations. Also, this increasing penetration of vRES requires higher ramping capabilities from units originally designed for other purposes (e.g., base-load generation), which might be exacerbated during contingency states. Hence, in this work, we propose a methodology to address the day-ahead Contingency-Constrained Unit Commitment (CCUC) problem that leverages the participation of Battery Energy Storage Systems (BESSs) to address load-following and post-contingency management, therefore alleviating the ramping burden on conventional thermal generators. To do so, we formulate a three-level optimization problem that represents the decision-making process of obtaining the least-cost commitment, generation and reserves scheduling, while restricting the Conditional Value-at-Risk (CVaR) of the system imbalance at real-time operations to user-defined tolerance levels. In addition, we devise a computationally efficient solution approach for the proposed problem based on the Column-and Constraint Generation (CCG) algorithmic framework. Two numerical experiments are conducted to empirically illustrate the benefits of the proposed methodology. Key results indicate a reduction in real-time ramping needs and a better usage of the system resources, with a reduction in the overall system commitment levels and reserve scheduling costs when compared to a benchmark case in which storage is not available.

Moreira, Alexandre↗

Glassy Carbon Substrate Oxidation Effects on Electrode Stability for Oxygen Evolution Reaction Catalysis Stability Benchmarking

Employing benchmarking metrics to capture the activity and stability of electrocatalysts for the oxygen evolution reaction (OER) in acid is a critical practice that enables meaningful comparison of catalyst material candidates reported throughout the literature. In this work, we find that ubiquitously used glassy carbon electrode substrates oxidize under typical OER operating conditions, forming a pacified, electrically insulating, and oxygen-rich surface layer that causes drastic loss of current density over the course of extended chronoamperometric stability tests at an anodic potential of 1.7 VRHE. We show that the experimentally observed stability of glassy carbon-based electrodes is approximately two orders of magnitude lower than that expected solely from dissolution-based catalyst intrinsic stability of Ir-based catalysts. We additionally find that glassy carbon-based electrode stability measured by chronoamperometric holds is greatly impacted by catalyst loading, with high catalyst loadings improving the stability of the overall electrode via a protective effect on the glassy carbon substrate. Altogether, our investigation highlights that glassy carbon is not electrochemically inert under OER conditions on the timescale of common stability tests, which can cause electrodes to exhibit performance losses that do not reflect the intrinsic stability of the actual catalyst material being investigated. In light of our findings, we underscore the usefulness of metrics, such as the S-number, to reflect intrinsic catalyst material stability.

25 ENERGY STORAGE↗

Battle of the Defaults: Extracting Performance Characteristics of HDF5 under Production Load

Popular parallel I/O libraries, such as HDF5, provide tuning parameters to obtain superior performance. However, the selection of effective parameters on production systems is complex due to the interdependence of I/O software and file system layers. Hence, application developers typically use the default parameters and often experience poor I/O performance. This work conducts a benchmarking-based analysis on the HDF5 behaviors with a wide variety of I/O patterns to extract performance characteristics under the production workload. To make the analysis well controlled, we exercise I/O benchmarks on POSIX-IO, MPI-IO, and HDF5 using the same I/O patterns and in the same jobs. To address high performance variability in production environments, we repeat the benchmarks across I/O patterns, storage devices, and time intervals. Based on the results, we identified consistent HDF5 behaviors that appropriate configurations and operations on dataset layout and file-metadata placement can improve performance significantly. We apply our findings and evaluate the tuned I/O library on two supercomputers: Summit and Cori. The results show that our tuned parameters can achieve more than 10× I/O performance speedup than that with default parameters on both systems, suggesting the effectiveness, stability, and generality of our solution.

Xie, Bing↗

Novel artificial neural network model for instantaneous power losses and operational efficiency mapping of MW-scale vanadium redox flow battery for improved technoeconomic analysis

A novel data-driven, machine-learning-based method for modeling the instantaneous power losses of a distribution-sited 2 MW/8MWh vanadium redox flow battery (VRFB), a grid-scale electrochemical storage technology, is introduced and compared against benchmark empirical modeling approaches, including symmetric and asymmetric models, as well as a recent convex hull modeling approach. The novel loss modeling method introduces several advantages over the benchmark models and over simplistic efficiency estimates, the most significant of which is that the model can accurately reflect the stepwise and non-linear parasitic losses associated with the duty cycles of mechanical auxiliary systems like pump motor drives and blower fans. Residuals of the models are compared; the proposed data driven model features significantly improved accuracy over the benchmark models. The model's coefficient of determination is also improved relative to that of the benchmark models. Furthermore, a novel method for visualization of operational efficiency of the grid-scale storage technology is introduced. To demonstrate the benefits of the novel data-driven method for modeling the VRFB, the benchmark models and the proposed models are embedded into an Open DSS distribution network model to study two applications of the grid-scale electrical storage system: load leveling for grid support and energy arbitrage. This article demonstrates that the accuracy of the instantaneous power loss model significantly impacts the understanding of the state of charge of the VRFB. In turn, the accuracy of the efficiency modeling of the VRFB impacts the understanding of the potential economic value and technical benefits to the distribution network operators. In conclusion, the presented power loss modeling approach is, therefore, highly relevant for utility-stakeholders, battery asset owners, system engineers, system designers, and financial planners interested in evaluating or optimizing the operation of grid-scale VRFBs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cyclic moisture reactivation of calcium sorbents for long duration thermochemical energy storage

The transition to a flexible and reliable energy infrastructure, using electro-thermal energy generation technologies such as geothermal, concentrated solar power, and nuclear, usually demands simultaneous advancement of thermal energy storage (TES) to support on-demand electricity generation and industrial applications while mitigating the inherent intermittency of renewable energy sources and power outages from direct energy generation. Among TES technologies, thermochemical energy storage (TCES) based on calcium looping emerges as a compelling high-power energy storage candidate due to its high reaction enthalpy, compatibility with elevated operating temperatures, and abundance of low-cost materials. However, the long-term durability of calcium-based sorbents for TCES is hindered by surface sintering and particle aggregation, leading to performance degradation over repeated thermal cycles. This study explores a moisture hydration-based strategy to regenerate a degraded calcium sorbent and mitigate performance degradation for long duration TCES. The addition of moisture transforms calcium oxide into calcium hydroxide and produces intercalation water layers, associated with a regenerated surface area and reduced calcium oxide crystallite size. Both these effects are beneficial in restoring the sorbents' reactivity for carbonization. Additionally, an optimized hydration-assisted reactivation protocol balances the recovered energy storage capacity with heating penalty required for moisture removal from hydrated samples, resulting in an enhanced energy storage capacity up to 176% compared to benchmark sorbents that undergo cycling without reactivation after 60 cycles. In conclusion, these results highlight the potential of hydration-assisted reactivation to enhance the long-term performance of TCES, providing an effective pathway to advancing electro-thermal storage technologies.

36 MATERIALS SCIENCE↗

Simultaneous Control of Pore‐Space Partition and Charge Distribution in Multi‐Modular Metal–Organic Frameworks

Abstract We report here a strategy for making anionic pacs type porous materials by combining pore space partition with charge reallocation. The method uses the first negatively charged pore partition ligand (2,5,8‐tri‐(4‐pyridyl)‐1,3,4,6,7,9‐hexaazaphenalene, H‐tph) that simultaneously enables pore partition and charge reallocation. Over two dozen anionic pacs materials have been made to demonstrate their excellent chemical stability and a high degree of tunability. Notably, Ni 3 ‐bdt‐tph (bdt=1,4‐benzeneditetrazolate) exhibits month‐long water stability, while CoV‐bdt‐tph sets a new benchmark for C 2 H 2 storage capacity under ambient conditions for ionic MOFs. In addition to tunable in‐framework modules, we show feasibility to tune the type and concentration of extra‐framework counter cations and their influence on both stability and capability to separate industrial C 3 H 8 /C 3 H 6 and C 6 H 6 /C 6 H 12 mixtures.

Hong, Anh N.↗

Simultaneous Control of Pore-Space Partition and Charge Distribution in Multi-Modular Metal–Organic Frameworks

Here we report here a strategy for making anionic pacs type porous materials by combining pore space partition with charge reallocation. The method uses the first negatively charged pore partition ligand (2,5,8-tri-(4-pyridyl)-1,3,4,6,7,9-hexaazaphenalene, H-tph) that simultaneously enables pore partition and charge reallocation. Over two dozen anionic pacs materials have been made to demonstrate their excellent chemical stability and a high degree of tunability. Notably, Ni 3 -bdt-tph (bdt=1,4-benzeneditetrazolate) exhibits month-long water stability, while CoV-bdt-tph sets a new benchmark for C 2 H 2 storage capacity under ambient conditions for ionic MOFs. In addition to tunable in-framework modules, we show feasibility to tune the type and concentration of extra-framework counter cations and their influence on both stability and capability to separate industrial C 3 H 8 /C 3 H 6 and C 6 H 6 /C 6 H 12 mixtures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Volumetrics of Hydrogen Storage by Physical Adsorption

Physical adsorption remains a promising method for achieving fast, reversible hydrogen storage at both ambient and cryogenic conditions. Research in this area has recently shifted to focus primarily on the volumetric (H 2 stored/delivered per volume) gains achieved within an adsorptive storage system over that of pure H 2 compression; however, the methodology for estimating a volumetric stored or delivered amount requires several assumptions related to the ultimate packing of the adsorbent material into an actual storage system volume. In this work, we critically review the different assumptions commonly employed, and thereby categorize and compare the volumetric storage and delivery across numerous different porous materials including benchmark metal-organic frameworks, porous carbons, and zeolites. In several cases, there is a significant gain in both storage and delivery by the addition of an adsorbent to the high-pressure H 2 storage system over that of pure compression, even at room temperature. Lightweight, low-density materials remain the optimal adsorbents at low temperature, while higher density, open metal-containing frameworks are necessary for high-density room temperature storage and delivery.

08 HYDROGEN↗

HyMARC Seedling: Optimized Hydrogen Adsorbents via Machine Learning and Crystal Engineering

This final report is presented in two parts: In Part 1, the H 2 capacities of a diverse set of 918,734 metal-organic frameworks (MOFs) sourced from 19 databases is predicted via machine learning (ML). Using only 7 structural features as input, ML identifies 8,282 MOFs with the potential to exceed the capacities of state-of-the-art materials. The identified MOFs are predominantly hypothetical compounds having low densities (<0.31 g/cm3) in combination with high surface areas (>5,300 m2/g), void fractions ($0.90), and pore volumes (>3.3 cm3/g). The relative importance of the input features are characterized, and dependencies on the ML algorithm and training set size are quantified. The most important features for predicting H 2 uptake are pore volume (for gravimetric capacity) and void fraction (for volumetric capacity). The ML models are available on the web, allowing for rapid and accurate predictions of the hydrogen capacities of MOFs from limited structural data; the simplest models require only a single crystallographic feature. In part 2, ways to improve the poor powder packing density of MOFs is discussed. More specifically, a strategy that improves packing efficiency and volumetric hydrogen gas storage density dramatically through engineered morphologies and controlled-crystal size distributions is presented that holds promise for maximizing storage capacity for a given MOF. The packing density improvement, demonstrated for the benchmark sorbent MOF-5, leads to a significant enhancement of volumetric hydrogen storage performance relative to commercial MOF-5. System model projections demonstrate that engineering of crystal morphology/size or use of a bimodal distribution of cubic crystal sizes in tandem with system optimization can surpass the 25 g/L volumetric capacity of a typical 700 bar compressed storage system and exceed the DOE targets 2020 volumetric capacity (30 g/L). Finally, a critical link between improved powder packing density and reduced damage upon compaction is revealed leading to sorbents with both high surface area and high density.

08 HYDROGEN↗

Nonexhaustive Taxonomy of Hydropower and Pumped Storage Hydro Facilities [Slides]

The National Renewable Energy Laboratory (NREL) has published benchmark technical reports and presentations that disaggregate major product components for a variety of technologies, including land-based and offshore wind, photovoltaic, and battery energy storage systems. NREL has partnered with staff from the Pacific Northwest National Laboratory (PNNL) and members of the U.S. Department of Energy's Water Power Technology Office (WPTO) to create a non-exhaustive taxonomy of the major products and components of hydropower and pumped storage systems.

13 HYDRO ENERGY↗

(Oxy)hydroxides Formed on Aluminum Fuel Materials After Irradiation and Long-Term Wet Storage - 20354

The aluminum cladding of research-reactor fuel experiences general corrosion when in contact with water during in-reactor service and post-discharge wet storage, resulting in the formation of adherent aluminum (oxy)hydroxide films. These (oxy)hydroxides contain chemically-bound water that poses challenges for extended dry storage due to the risk of thermal or radiolytic decomposition releasing free water and/or hydrogen and oxygen gases. This study describes characterization of the (oxy)hydroxides present on several aluminum materials used in reactor operation and subsequently stored wet in the L-Basin storage facility at the Savannah River Site (SRS) for an extended period. Characterization data providing insight into the loading, composition, and morphology of (oxy)hydroxides to be expected on service-exposed aluminum cladding provides valuable benchmarks for designing adequate drying and dry-storage approaches. This work is part of a broader investigation to address knowledge gaps and technical data needs for dry storage of aluminum-clad spent nuclear fuel (ASNF), which included in-lab growth of (oxy)hydroxide films on aluminum alloy substrates to investigate formation behavior, investigation of drying methods to remove existing (oxy)hydroxides from ASNF cladding, and measurement of radiolytic yield of hydrogen from (oxy)hydroxide powders and films. In this study, (oxy)hydroxide films were characterized for three aluminum-alloy materials used in reactors and subsequently stored wet for up to approximately 40 years in L-Basin at SRS: one cropping from a Missouri University Research Reactor (MURR) fuel element (Al-6061 alloy), one cropping from a Universal Sleeve Housing (USH) (Al-6063 alloy), and one Mark-16B fuel assembly (either Al-6061 or Al- 6063). The USH and Mark-16B were used in SRS production reactors. Characterization of the as-received (oxy)hydroxides included scanning electron microscopy (SEM) in both plan-view and cross-section to characterize the (oxy)hydroxide layer's morphology, thickness, and structure. X-ray diffraction (XRD) was used to identify the chemical composition and distinguish between the various aluminum (oxy)hydroxides known to form under reactor and storage conditions. XRD analysis revealed both bayerite (Al(OH)3) and boehmite (AlOOH) on the surface of the MURR and USH samples, as well as bayerite, boehmite, and gibbsite (another Al(OH)3 polymorph) on the surface of the Mark-16B sample. The aluminum trihydroxides, bayerite and gibbsite, are typically associated with corrosion in low-temperature (<80 deg. C) water, while boehmite is expected to form at higher water temperature (>80 deg. C). The presence of bayerite on the USH, which is believed to have operated close to 90 deg. C, suggests that boehmite formed during in-reactor exposure was not protective against further hydroxide growth in low-temperature wet storage. Cross-section scanning electron microscopy (SEM) showed total (oxy)hydroxide layer thicknesses of ∼5- 10 μm for the MURR and ∼5-15 μm for the Mark-16B. The thickness of the USH's (oxy)hydroxide layer was indiscernible by the current mounting and imaging method, despite plan-view SEM and XRD confirming the presence of an (oxy)hydroxide layer. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Online transfer learning strategy for enhancing the scalability and deployment of deep reinforcement learning control in smart buildings

In recent years, advanced control strategies based on Deep Reinforcement Learning (DRL) proved to be effective in optimizing the management of integrated energy systems in buildings, reducing energy costs and improving indoor comfort conditions when compared to traditional reactive controllers. However, the scalability and implementation of DRL controllers are still limited since they require a considerable amount of time before converging to a near-optimal solution. This issue is currently addressed in literature through the offline pre-training of the DRL agent. However this solution results in two main critical issues: (1) the need to develop a building surrogate model to perform the training task, and (2) the need to perform a fine-tuning process over several training episodes to obtain a near-optimal control policy. In this context, this paper introduces an Online Transfer Learning (OTL) strategy that exploits two knowledge-sharing techniques, weight-initialization and imitation learning, to transfer a DRL control policy from a source office building to various target buildings in a simulation environment coupling EnergyPlus and Python. A DRL controller based on discrete Soft Actor–Critic (SAC) is trained on the source building to manage the operation of a cooling system consisting of a chiller and a thermal storage. Several target buildings are defined to benchmark the performance of the OTL strategy with that of a Rule-Based Controller (RBC) and two DRL-based control strategies, deployed in offline and online fashion. The strategy adopted for OTL emulates the real world implementation with a simulation process by implementing the transferred DRL agent for a single episode in the target buildings. Target buildings have the same geometrical features and are served by the same energy system as the source building, but differ in terms of weather conditions, electricity price schedules, occupancy patterns, and building envelope efficiency levels. The results show that the OTL strategy can reduce the cumulated sum of temperature violations on average by 50% and 80% respectively when compared to RBC and online DRL while enhancing the energy system operation with electricity cost savings ranging between 20% and 40%. Furthermore, the OTL agent performs slightly worse than the offline DRL controller but it does not require any modeling effort and can be implemented directly on target buildings emulating a real-world implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multi-Source Data Aggregation and Real-Time Anomaly Classification and Localization in Power Distribution Systems

This paper proposes a real-time anomaly location and classification framework for power distribution systems to simultaneously determine the type of anomaly (i.e., short-circuit fault, cyber attack, DER switching) and its location. The proposed framework employs the data aggregation module to collect the measurement data from multiple field devices operating at different sampling rates, such as protection relays and D-PMUs. The output of the data aggregation is then fed into a multi-task learning-based long-based short-term memory (MTL-LSTM) to classify the type of anomaly and the location in two separate tasks. The proposed MTL-LSTM approach can be utilized in real-time operation in order to distinguish between normal and several anomalous operations and locate the anomaly. The proposed framework is tested on a modified IEEE 33-bus test feeder benchmark that integrates solar generation and energy storage. Furthermore, the results show that the proposed framework can locate and classify anomalies for several operation conditions with more than 96% accuracy. Further experiments highlight the impact of aggregating multiple sources of data on the performance of the proposed model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Investigation of Thermal-Hydraulic Effects of Dry Storage Canister Helium Backfill Loss Using the Horizontal Dry Cask Simulator

A previous investigation produced data sets that can be used to benchmark the codes and best practices presently used to determine cladding temperatures and induced cooling air flows in modern horizontal dry storage systems. The horizontal dry cask simulator (HDCS) was designed to generate this benchmark data and add to the existing knowledge base. The objective of the previous HDCS investigation was to capture the dominant physics of a commercial dry storage system in a well-characterized test apparatus for a wide range of operational parameters. The close coupling between the thermal response of the canister system and the resulting induced cooling air flow rate was of particular importance. The previous investigation explored these parameters using helium backfill at 100 kPa and 800 kPa pressure as well as air backfill with a series of simulated decay heats. The helium tests simulated a horizontal dry cask storage system at normal storage conditions with either atmospheric or elevated backfill pressure, while the air tests simulated horizontal storage canisters following a complete loss of helium backfill, in which case the helium would be replaced by air. The present HDCS investigation adds to the previous investigation by exploring steady-state conditions at various stages of the loss of helium backfill from a horizontal dry cask storage system. This is achieved by using helium/air blends as a backfill in the HDCS and running a series of tests using various simulated decay heats to explore the effects of relative helium/air molar concentration on the thermal response of a simulated horizontal dry cask storage system. A total of twenty tests were conducted where the HDCS achieved steady state for various assembly powers, representative of decay heat. The power levels tested were 0.50, 1.00, 2.50, and 5.00 kW. All tests were run at 100 kPa vessel pressure. The backfill gases used in these tests are given in this report as a function of mole fraction of helium (He), balanced by air: 1.0, 0.9, 0.5, 0.1, and 0.0 He. Steady-state conditions (where the steady-state start condition is defined as where the change in temperature with respect to time for the majority of HDCS components is less than or equal to 0.3 K/h) were achieved for all test cases.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Sparse chronology strategy for integrating seasonal energy storage in capacity expansion models

Here, this study develops the sparse chronology method to enhance the representative period framework in capacity expansion models, enabling the effective integration of long-duration energy storage modeling. Traditional representative period methods cannot capture the state of charge of seasonal energy storage systems because they do not establish effective inter-day linkages to connect the state of charge between periods. The sparse chronology approach addresses this limitation by establishing inter-day linkages that allow state of charge to shift inter-seasonally. At the same time, it groups identical representative days into partitions, applying constraints sparsely and implicitly to reduce computational load further. Validation results demonstrate that this method successfully simulates long-duration energy storage patterns, achieving close alignment with a continuous yearly benchmark model, with seasonal trends and state of charge cycles clearly represented. The computational load analysis reveals that the sparse chronology method efficiently applies constraints on maximum and minimum state of charge limits within the representative day framework, eliminating the need for detailed constraints on each individual day. By partitioning representative days and constraining only the start and end of each partition, the method significantly decreases computational requirements. Simulation results show that sparse chronology closely approximates the continuous yearly method's accuracy, even with as few as 20 representative days, achieving correlation values with the benchmark of nearly 0.9 in state of charge plots. Furthermore, it maintains computational efficiency, requiring only 4 % of the solver time compared to the continuous yearly method with 20 representative days. This approach allows capacity expansion models to incorporate long-duration energy storage with high temporal, spatial, and technological resolution, enabling more detailed modeling for large-scale power systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Small tensor product distributed active space (STP-DAS) framework for relativistic and non-relativistic multiconfiguration calculations: Scaling from 10 9 on a laptop to 10 12 determinants on a supercomputer

Despite the power and flexibility of configuration interaction (CI) based methods in computational chemistry, their broader application is limited by an exponential increase in both computational and storage requirements, particularly due to the substantial memory needed for excitation lists that are crucial for scalable parallel computing. Here, the objective of this work is to develop a new CI framework, namely, the small tensor product distributed active space (STP-DAS) framework, aimed at drastically reducing memory demands for extensive CI calculations on individual workstations or laptops, while simultaneously enhancing scalability for extensive parallel computing. Moreover, the STP-DAS framework can support various CI-based techniques, such as complete active space (CAS), restricted active space, generalized active space, multireference CI, and multireference perturbation theory, applicable to both relativistic (two- and four-component) and non-relativistic theories, thus extending the utility of CI methods in computational research. We conducted benchmark studies on a supercomputer to evaluate the storage needs, parallel scalability, and communication downtime using a realistic exact-two-component CASCI (X2C-CASCI) approach, covering a range of determinants from 10 9 to 10 12 . Additionally, we performed large X2C-CASCI calculations on a single laptop and examined how the STP-DAS partitioning affects performance.

Complete-active space self-consistent field↗