Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “standards gap analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Liquid hydrogen storage system for heavy duty trucks: Configuration, performance, cost, and safety

In this work, we investigate the potential of liquid hydrogen storage (LH 2 ) on-board Class-8 heavy duty trucks to resolve many of the range, weight, volume, refueling time and cost issues associated with 350 or 700-bar compressed H 2 storage in Type-3 or Type-4 composite tanks. We present and discuss conceptual storage system configurations capable of supplying H 2 to fuel cells at 5-bar with or without on-board LH 2 pumps. Structural aspects of storing LH 2 in double walled, vacuum insulated, and low-pressure Type-1 tanks are investigated. Structural materials and insulation methods are discussed for service at cryogenic temperatures and mitigation of heat leak to prevent LH 2 boiloff. Failure modes of the liner and shell are identified and analyzed using the regulatory codes and detailed finite element (FE) methods. The conceptual systems are subjected to a Failure modes and effects analysis (FMEA) and a safety, codes, and standards (SCS) review to rank failures and identify safety gaps. The results indicate that the conceptual systems can reach 19.6% usable gravimetric capacity, 40.9 g-H 2 /L usable volumetric capacity and $174-183/kg-H 2 cost (2016 USD) when manufactured 100,000 systems annually.

08 HYDROGEN↗

A Review and Outlook on Experimental Advances and Innovations in Geological CO 2 Storage: Insights from Depleted Gas Reservoirs and Saline Aquifers

Geological storage of carbon dioxide (CO 2 ) in depleted gas reservoirs and deep saline aquifers is a key part of global decarbonization efforts. As carbon capture and storage advances toward commercial-scale deployment, the credibility and scalability of laboratory experiments are increasingly vital for guiding safe and effective field implementation. This review offers a comprehensive, cross-scale evaluation of experimental methodologies, including core flooding, high-pressure, high-temperature systems, microfluidic visualization, and emerging systems such as multilayer commingled/compartmentalized core flooding, 3D-printed micromodels, and AI-powered digital twins. These innovations are demonstrated to enhance representativeness, reproducibility, and real-time insight, thereby addressing the limitations of conventional workflows. A critical analysis of methodological gaps, such as inconsistent pressure–temperature conditions, oversimplified brine chemistry, and a lack of standardization, reveals experimental sources of scale translation errors and performance uncertainty. By comparing the unique challenges of depleted gas reservoirs (such as low water saturation and legacy well leakage) to those of saline aquifers (including pressure buildup and caprock integrity), this review identifies formation-specific priorities for experimental design. Novel contributions include a synthesis of best practices, integration strategies for model calibration, and recommendations for standardizing core handling, saturation procedures, and reporting protocols. Furthermore, this work serves as a guide for developing robust, field-relevant experimental strategies that can increase the deployment and regulatory acceptance of CO 2 storage technologies at scale.

58 GEOSCIENCES↗

Bridging the Gap on Data and Analysis for Distribution System Planning: Information That Utilities Can Provide Regulators, State Energy Offices and Other Stakeholders

Electric utilities conduct planning annually to ensure their distribution system meets technical standards, policies, and regulations; addresses forecasted grid conditions; satisfies customer needs; and advances utility priorities. The plan identifies grid deficiencies, analyzes potential solutions, and prioritizes capital investments and other expenditures. About 20 U.S. states and jurisdictions require regulated utilities to file some type of distribution system plan with the public utility commission for review. Requirements for sharing distribution system data and analyses vary widely, from few specific requirements to a detailed list of information that must be provided. While utilities conduct extensive analysis to develop distribution system plans, in most jurisdictions regulators and stakeholders do not know what data are available and how the utility uses the data in planning and investing. This report aims to bridge the gap by increasing understanding of the types of data and analyses utilities employ to develop distribution system plans and how the information affects their decision-making. The report describes information that states and stakeholders can ask for related to 11 data categories: -Forecasting loads and distributed energy resources (DERs) -Scenario analysis -Worst-performing circuits -Asset management strategy -Hosting capacity analysis -Value of DERs -Grid needs assessment -Cost-effectiveness framework for investments -Distribution system investment strategy and implementation -Geotargeted programs -Non-wires alternatives procurements.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Stability, electronic quantum states, and magnetic interactions of Er 3+ ions in Ga 2 ⁢O 3

Here, we report an ab initio study of phase stability, defect formation, electronic structure, and multiple magnetic, Dzyaloshinskii-Moriya, optical, hyperfine, and crystal field interactions in erbium (Er)-doped wide band gap 𝛼- and 𝛽-gallium oxides (Ga 2 ⁢O 3 ), critically important to make a foundation for both optoelectronic and quantum information applications. The chemical, structural, mechanical, and dynamical stabilities of the pristine phases are confirmed from respective negative formation energies, negative cohesive energies, favorable elastic constants, and positive phonon frequencies. The phonon dispersions indicate that the Ga-O bonds are uniform in the 𝛼-phase, while they vary in the 𝛽-phase due to the anisotropic polyhedral movement. The defect formation energy analysis confirms that both Er-doped 𝛼- and 𝛽−Ga 2 ⁢O 3 prefer Er 3+ (neutral) state. The underestimated band gaps of the pristine phases from standard density functional theory (DFT) calculations as compared to experimental values are corrected by employing the hybrid functional calculations, resulting in the indirect band gaps of 5.21 eV in 𝛼−Ga 2 ⁢O 3 and 4.94 eV in 𝛽−Ga 2 ⁢O 3 . The site preference energy analysis indicates partial occupation of Er in the octahedral site of Ga. The anisotropic nature of hyperfine tensor coefficients of Er is similar in both phases, which may be due to the occupation of Er in the same octahedral Ga site. On the other hand, the calculated magnetic exchange interaction between two Er dopants is negative for 𝛼 and positive for 𝛽, indicating an antiferromagnetic (AFM) ground state in the former and a ferromagnetic (FM) ground state in the latter. Large values of Dzyaloshinskii-Moriya interactions (DMIs) are obtained along the 𝑥 direction in the 𝛼 and along the 𝑦 direction in the 𝛽. The large DMI may support exotic magnetic textures, a promising direction for spintronic applications. The analysis of dielectric constants and refractive indices of both pristine and Er-doped phases shows a good agreement with available experimental values. The calculated optical anisotropy is slightly higher in 𝛽 than those in 𝛼, which is due to the involvement of lower symmetry in 𝛽. The crystal field coefficients (CFCs) calculated from DFT are used to analyze 4⁢𝑓 multiplets and 4⁢𝑓 −4⁢𝑓 transitions. Thus calculated lowest energy level of the first excited state to the lowest energy level of the ground state is about 1.53 µ⁢m, which is in a good agreement with available experiments, and it falls within the quantum telecommunication wavelength range.

3-dimensional systems↗

Understanding EV Charging Pain Points Through Deep Learning Analysis

Current and potential electric vehicle (EV) owners express concerns about the charging infrastructure, mentioning non-functional chargers, prolonged charging times, inconvenient charger locations, long wait times, and high costs as major barriers. Addressing these issues often requires analyzing actual vehicle charging data, which is typically proprietary and inconsistent due to diverse standards and protocols. To understand and improve the EV charging experience, customer reviews are typically used to identify common customer pain points (CPPs). However, there is not a comprehensive method to map customer reviews to a standardized set of CPPs. In collaboration with the National Charging Experience (ChargeX) Consortium, this study bridges these gaps by proposing a Systematic Categorization and Analysis of Large-scale EV-charging Reviews (SCALER) framework. SCALER is an integrated, deep learning framework that segments, actively labels, analyzes, and classifies EV charging customer reviews into six CPP categories. To test its effectiveness, we used SCALER to analyze over 72,000 reviews from customers charging various EV models on different networks across the United States. SCALER achieves a classification accuracy of 92.5%, with an F1 score exceeding 85.7%. By demonstrating real-world applications of SCALER, we enhance the industry’s ability to understand and address CPPs to improve the EV charging experience.

29 - ENERGY PLANNING, POLICY AND ECONOMY↗

Numerical analysis of gas exhaust in Wendelstein 7-X using the direct simulation Monte Carlo method

The present work is focused on a 3D numerical assessment of the Wendelstein 7-X (W7-X) particle exhaust. For all the numerical simulations the direct simulation Monte Carlo solver of the DIVGAS workflow, has been employed. The complex 3D geometry of the sub-divertor region includes the pumping gap panel, supporting structures, cooling pipes as well as the cryo-vacuum pump. All the considered flow simulations correspond to the Standard magnetic configuration of W7-X. The main conclusions, which can be extracted from the present numerical analysis could be summarized as follows; The coupling between EMC3-EIRENE and DIVGAS, which considers the fact that the incoming neutral particle flux at the sub-divertor is based on realistic plasma background, has been demonstrated. Three plasma scenarios have been considered, for which is clearly seen that by increasing the heating power, the neutral pressure as well as the resulting pumping efficiency is increased. The obtained numerical results of the neutral pressure in the sub-divertor lie within a more general scan matrix, which assumes a wider range of incoming particle flux, namely 10 19 –10 24 (s −1 ). It has been observed that, the sub-divertor neutral pressure is proportional to the incoming neutral particle flux, with the effective pumping speed to be a constant of proportionality. The influence of switching off the cryo-vacuum pump on the sub-divertor pressure is rather modest and a weak increase of the neutral pressure in the sub-divertor is expected. Correlations of the sub-divertor pressure with the total incoming particle flux as well as the individual pumped flux at each of the AEH and AEP sections have been deduced. Moreover, it has been demonstrated that the influence of the incoming neutral particle flux on the albedo coefficient at the AEH and AEP pumping gaps is rather weak. All the above numerical findings will actively support the optimization of the W7-X particle exhaust, in view of future experimental campaigns.

DSMC method↗

Development and Preliminary Analysis of a U.S. Geothermal Heat Pump Installation Database

This paper seeks to addresses the significant gap in the literature regarding the installation and adoption of geothermal heat pump (GHP) systems in the United States. While the "2021 U.S. Geothermal Power Production and District Heating Market Report" published by the National Renewable Energy Laboratory (NREL) focused on direct-use geothermal district heating systems, it did not include an analysis of GHP installations (Robins et al. 2021). To bridge this gap, NREL has compiled a novel database currently containing 70,470 records of GHP installations, primarily sourced from state well permits and small-scale studies. Our methodology emphasizes the collection, cleaning, and standardization of data, addressing challenges such as inconsistent reporting formats and privacy concerns. Despite limitations in data on capacity, costs, and performance, our preliminary geospatial analysis reveals insights into the distribution of GHP systems across urban and rural areas and climate zones. The paper highlights the importance of publicly accessible data for advancing GHP technology adoption with a discussion of existing data sources and their limitations, advocating for improved collaboration between NREL and industry stakeholders.

data collection↗

Operation and Maintenance of PV Systems: Data Science, Analysis, and Standards

This effort improves the effectiveness and reduce uncertainty in O&M cost through four primary objectives/tasks: 1) institutionalize standards for reliability and availability reporting for large PV power plants; 2) bridge systemic O&M knowledge gaps around important topics affecting O&M; 3) characterize systemic failure modes and patterns and accelerate O&M experiential learning cycles using field data; and 4) establish a baseline understanding of UPVS O&M cost drivers. Key results of this effort include publication of IEC standards, published topical papers on O&M topics, training, and characterize field data for climate- and service-related patterns (additional details below). Integrating these results serves to reduce performance risk and facilitate improvement in the way solar projects are operated and maintained. Results are well received and two publications are among the most successful SETO publications at NREL ("Model of Operation and Maintenance Costs for Photovoltaic Systems with over 40,000 downloads and "Best Practices in Operation and Maintenance of PV Systems, 3rd Ed." with over 90,000 downloads).

14 SOLAR ENERGY↗

Statistically-driven Experimental Design to Improve Reference-free Quantification of Small Molecules by Liquid Chromatography-Mass Spectrometry

Non-targeted analysis of small molecules and metabolites in unknown, complex samples using liquid chromatography-tandem mass spectrometry remains challenging. One of the main bottlenecks is the extensive unannotated regions of metabolomics mass spectrometry data, resulting in knowledge gaps. Small molecule annotation in mass spectrometry data has conventionally relied on reference standards and libraries for compound identification and confirmation, which can constrain compound identification to those molecules already known, thus limiting the ability to discover new knowledge and new markers. Retention time prediction can facilitate and expedite unknown compound identification in non-targeted analysis of complex metabolomics samples. Additionally, accurate retention time predictions can also inform sample mixture design for LC-MS/MS analyses. However, current machine learning-based methods for retention time prediction are typically developed for specific chromatographic platforms and are not generalizable across scales. And while technologies and methods to improve reference-free metabolite identification for more comprehensive annotation of unknowns has received much attention, development of the same for quantitation without reference standards has been much more limited, despite its importance in toxicological, environmental, food safety, forensics, and clinical applications. We believe that a reference-free quantitation strategy that exploits mass spectrometry data already collected for reference-free identification can provide much more insight on unknowns, and move the metabolomics field for more complete unknowns characterization. As such, we pursue two efforts to improve upon current state-of-the-art methods in non-targeted analysis: (1) machine learning-based retention time prediction and (2) statistical design of experiments framework for reference-free quantitation. In this work, we develop and demonstrate (1) a generalizable retention time prediction capability across chromatographic conditions and scales, and (2) a statistical design-based framework for response factor contribution elucidation and reference-free quantitation. Evaluation of our retention time prediction model, PrediToR, showed approximately 24% improvement over current models, and we observed approximately 10X improvement in concentration estimation accuracy from our statistical design-based response factor model over a primarily ionization efficiency-based model. We expect that future efforts to improve upon these new capabilities will further advance non-targeted analysis of small molecules towards truly reference-free metabolomics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design and performance of a variable gap system for thermal conductivity measurements of high temperature, corrosive, and reactive fluids

We report high-temperature fluids such as molten salts, liquid metals, and gasses are being proposed for many advanced energy systems including thermal energy storage devices, concentrating solar plants, and advanced nuclear reactor designs. However, the chemical behavior and thermophysical properties of many of these fluids have not been well characterized, which hinders the design, modeling, safety analysis, and deployment of these systems. Thermal conductivity is a property that is especially limited by existing measurement capabilities, which are subject to errors caused by convection, material interaction, radiative heat transfer, and instrument degradation. Therefore, there is a lack of standard, systematic measurement techniques for high-temperature, reactive, and corrosive fluids. In this work, the development of a variable gap thermal conductivity measurement system is detailed. The system is designed to measure the thermal conductivity of highly corrosive and reactive fluids, and survive operation between 100 °C and 800 °C. The effects of convection are minimized by limiting the thickness of the specimen to thin sizes (<0.3 mm). Corrections for radiative heat transfer were included in the working equations to consider specimens with varying optical properties. The design, construction, instrumentation, operating principles, and data analysis techniques are discussed in detail. The system was tested up to 500 °C using helium gas and molten KNO 3 -NaNO 3 to verify the measurement technique and determine the sources of error. At 300 and 400 °C KNO 3 -NaNO 3 , results showed maximum relative error of 6% when compared to results in the literature. The helium results were within 13% of those in the literature at 300 and 400 °C. Higher errors were observed at 500 °C for both fluids, and the sources of these errors are discussed.

42 ENGINEERING↗

Enhancing Electron Microscopy Image Classification Using Data Augmentation

Manual labeling for machine learning tasks such as image classification is tedious and labor-intensive; as a result, scientific datasets suitable for deep learning applications are scarce and limited. While data augmentation techniques have shown promise for extending image datasets, very little work has been done to understand the impact of combining multiple augmentation methods sequentially or the limits of their effectiveness when combined. Our work addresses this gap by examining how standard and combinatorial data augmentation affects the performance of machine learning models when trained on small datasets for label classification tasks. For our analysis, we generate single, double and quadruple-augmented datasets for a microscopy image classification task using six standard augmentation methods, and compare the resultant improvements observed in binary classification accuracy with three standard image classification models (DenseNet169, MobileNetV2, ResNet101V2). Our experiments show a non-monotonic relationship between the number of simultaneous augmentation methods and classification accuracy, indicating that there is a trade-off between the degree of augmentation and the model performance. These findings suggest that the optimal number of augmentation methods will vary by domain and use case. We also find that the order in which augmentation methods are applied to a limited dataset matters when combining augmentation schemes, with our use case showing performance differences up to 2.6% when the augmentation order is reversed for double-augmented datasets. Our work offers insights to the limits of data augmentation when working on image classification tasks with limited datasets.

Welsman, Jordan A↗

Machine learning BPS spectra and the gap conjecture

We explore statistical properties of Bogomol’nyi-Prasad-Sommerfield q-series for strongly coupled supersymmetric theories that correspond to a particular family of three-manifolds. We discover that gaps between exponents in the -series are statistically more significant at the beginning of the -series compared to gaps that appear in higher powers of. Our observations are obtained by calculating saliencies of -series features used as input data for principal component analysis, which is a standard example of an explainable machine learning technique that allows for a direct calculation and a better analysis of feature saliencies.

97 MATHEMATICS AND COMPUTING↗

Heliostat Consortium: Gap Analysis on Wind Load for Achieving a Fully Competitive Heliostat Industry

The Heliostat Consortium (HelioCon) Wind Load Subtask was initiated with the aim of bringing research work pertaining to wind load measurement, characterization, and prediction taking place across several tasks, including Advanced Manufacturing, Components and Controls, and Field Deployment. The cross-cutting wind load subtopic in the HelioCon roadmap report [1] highlighted standardized methods and tools that are needed for a more detailed understanding of the static and dynamic loads on a heliostat. This will enable cost reduction of wind-dependent heliostat components to avoid unnecessarily conservative, overly constrained designs and increase field efficiency/reliability, to reduce the risk of component failures due to high-wind events (>15 m/s). Gaps related to heliostat wind load include site characterization for wind measurements, critical load cases for heliostat design, turbulence impacts on heliostat tracking error, testing of heliostat array configurations, understanding spatial variation of maximum loads across the solar field, and heliostat field layout and operating strategies. The recommended highest-priority pathway as first steps taken by HelioCon to address these gaps are to develop site characterization guidelines for heliostat design and field load measurements.

Emes, Matthew (ORCID:0000000341474387)↗

Metagenomic Methods for Addressing NASA's Planetary Protection Policy Requirements on Future Missions: A Workshop Report

Molecular biology methods and technologies have advanced substantially over the past decade. These new molecular methods should be incorporated among the standard tools of planetary protection (PP) and could be validated for incorporation by 2026. To address the feasibility of applying modern molecular techniques to such an application, NASA conducted a technology workshop with private industry partners, academics, and government agency stakeholders, along with NASA staff and contractors. The technical discussions and presentations of the Multi-Mission Metagenomics Technology Development Workshop focused on modernizing and supplementing the current PP assays. The goals of the workshop were to assess the state of metagenomics and other advanced molecular techniques in the context of providing a validated framework to supplement the bacterial endospore-based NASA Standard Assay and to identify knowledge and technology gaps. In particular, workshop participants were tasked with discussing metagenomics as a stand-alone technology to provide rapid and comprehensive analysis of total nucleic acids and viable microorganisms on spacecraft surfaces, thereby allowing for the development of tailored and cost-effective microbial reduction plans for each hardware item on a spacecraft. Workshop participants recommended metagenomics approaches as the only data source that can adequately feed into quantitative microbial risk assessment models for evaluating the risk of forward (exploring extraterrestrial planet) and back (Earth harmful biological) contamination. Participants were unanimous that a metagenomics workflow, in tandem with rapid targeted quantitative (digital) PCR, represents a revolutionary advance over existing methods for the assessment of microbial bioburden on spacecraft surfaces. The workshop highlighted low biomass sampling, reagent contamination, and inconsistent bioinformatics data analysis as key areas for technology development. Finally, it was concluded that implementing metagenomics as an additional workflow for addressing concerns of NASA's robotic mission will represent a dramatic improvement in technology advancement for PP and will benefit future missions where mission success is affected by backward and forward contamination.

59 BASIC BIOLOGICAL SCIENCES↗

Facilitating Data Collection of Maintenance Events to Populate the Hydrogen Component Reliability Database (HyCReD)

The Hydrogen Component Reliability Database (HyCReD) is a collaborative project between the National Renewable Energy Laboratory, the University of Maryland, and hydrogen stakeholders to improve safety and reliability for hydrogen facilities by implementing component reliability data taxonomies that support hydrogen infrastructure failure rate analysis. The project aims to quantify failure rates of hydrogen components through high-quality data collection and analysis on root causes and maintenance needed. HyCReD provides a common database for cataloging hydrogen component failures which exists for reliability research in many other mature industries [2]. The database fills a gap for the hydrogen community by providing a scientifically rigorous approach to quantitative risk assessment (QRA), prognostic health management (PHM), and reliability-centered maintenance (RCM) analysis. High level results will be aggregated and anonymized to protect company sensitive information; detailed results will be used to help address issues of hydrogen components. These advanced analytics will support accelerated deployment of hydrogen infrastructure by enabling better: design and safety of projects (safety codes and standards development), infrastructure reliability and cost (component failure rates, maintenance protocols), and component R&D needs (robust supply chain). A key to a successful HyCReD implementation is facilitating the ease of reporting and data quality in the database that can be used for analysis. Maintenance data was a previously identified gap in initial efforts to populate and validate the database taxonomies [3]. Collection of maintenance data will be instrumental in identifying failure modes and rates, identifying incipient component failures or reduced performance, cataloging best practices for maintenance routines and methods for prognostic health management, and quantifying the risk and effect of different failure modes. Several key priorities are identified for streamlined data collection to achieve quality and detailed failure data: Applicability, Ease of Use, Accessibility, and Information Security. The HyCReD team has now begun deployment of the database to several companies and groups that have signed non-disclosure agreements to facilitate the data collection of failures in industry hydrogen refueling station infrastructure. This paper will provide an update into the process of HyCReD deployment including the development of a coding guide for facility personnel to reference and ensure data quality and consistency from one station to another as well as implementation of contextually dependent data fields of system taxonomy and formatted entries to provide ease of use. The goal is to communicate the lessons learned from the roll-out to technicians and engineers in the field, and the addition of need for high level of security to protect all stakeholders.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Floods and Heavy Precipitation at the Global Scale: 100‐Year Analysis and 180‐Year Reconstruction

Floods and heavy precipitation have disruptive impacts worldwide, but their historical variability remains only partially understood at the global scale. This article aims at reducing this knowledge gap by jointly analyzing seasonal maxima of streamflow and precipitation at more than 3,000 stations over a 100‐year period. The analysis is based on Hidden Climate Indices (HCIs). Like standard climate indices (e.g., Nino 3.4, NAO), HCIs are used as covariates explaining the temporal variability of data, but unlike them, HCIs are estimated from the data. In this work, a distinction is made between common HCIs, that affect both heavy precipitation and floods, and specific HCIs, that exclusively affect one or the other. Overall, HCIs do not show noticeable autocorrelation, but some are affected by noticeable trends. In particular, strong and wide‐ranging trends are identified in precipitation‐specific HCIs, while trends affecting flood‐specific HCIs are weaker and have more localized effects. A probabilistic model is then derived to link HCIs and large‐scale atmospheric variables (pressure, wind, temperature) and to reconstruct HCIs since 1836 using the 20CRv3 reanalysis. In turn this allows estimating the probability of occurrence of floods and heavy precipitation at the global scale. This 180‐year reconstruction highlights flood hot‐spots and hot‐moments in the distant past, well before the establishment of perennial monitoring networks. Finally, the approach presented in this study is generic and paves the way for an improved characterization of historical variability by making a better use of long but highly irregular station data sets.

54 ENVIRONMENTAL SCIENCES↗

Hidden vibronic and excitonic structure and vibronic coherence transfer in the bacterial reaction center

We report two-dimensional electronic spectroscopy (2DES) experiments on the bacterial reaction center (BRC) from purple bacteria, revealing hidden vibronic and excitonic structure. Through analysis of the coherent dynamics of the BRC, we identify multiple quasi-resonances between pigment vibrations and excitonic energy gaps, and vibronic coherence transfer processes that are typically neglected in standard models of photosynthetic energy transfer and charge separation. We support our assignment with control experiments on bacteriochlorophyll and simulations of the coherent dynamics using a reduced excitonic model of the BRC. We find that specific vibronic coherence processes can readily reveal weak exciton transitions. While the functional relevance of such processes is unclear, they provide a spectroscopic tool that uses vibrations as a window for observing excited state structure and dynamics elsewhere in the BRC via vibronic coupling. Vibronic coherence transfer reveals the upper exciton of the “special pair” that was weakly visible in previous 2DES experiments.

59 BASIC BIOLOGICAL SCIENCES↗