Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “split cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures: January 2012 - September 2016

This is the complete set of Uniform Methods Project protocols for determining energy efficiency savings for specific measures, all within one report. The report includes the following chapters: Chapter 1: Introduction. Chapter 2: Commercial and Industrial Lighting Evaluation Protocol. Chapter 3: Commercial and Industrial Lighting Controls Evaluation Protocol. Chapter 4: Small Commercial and Residential Unitary and Split System HVAC Cooling Equipment-Efficiency Upgrade Evaluation Protocol. Chapter 5: Residential Furnaces and Boilers Evaluation Protocol. Chapter 6: Residential Lighting Evaluation Protocol. Chapter 7: Refrigerator Recycling Evaluation Protocol. Chapter 8: Whole-Building Retrofit with Consumption Data Analysis Evaluation Protocol. Chapter 9: Metering Cross-Cutting Protocol. Chapter 10: Peak Demand and Time-Differentiated Energy Savings Cross-Cutting Protocol. Chapter 11: Sample Design Cross-Cutting Protocol. Chapter 12: Survey Design and Implementation for Estimating Gross Savings Cross-Cutting Protocol. Chapter 13: Assessing Persistence and Other Evaluation Issues Cross-Cutting Protocol. Chapter 14: Chiller Evaluation Protocol. Chapter 15: Commercial New Construction Evaluation Protocol. Chapter 16: Retrocommissioning Evaluation Protocol. Chapter 17: Residential Behavior Evaluation Protocol. Chapter 18: Variable Frequency Drive Evaluation Protocol. Chapter 19: HVAC Controls (DDC/EMS/BAS) Evaluation Protocol. Chapter 20: Data. Center IT Efficiency Measures Evaluation Protocol. Chapter 21: Estimating Net Savings - Common Practices. Chapter 22: Compressed Air Evaluation Protocol. Chapter 23: Combined Heat and Power Evaluation Protocol. Chapter 24: Strategic Energy Management (SEM) Evaluation Protocol

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Process for retrofitting an industrial gas turbine engine for increased power and efficiency

A process for retrofitting an industrial gas turbine engine of a power plant where an old industrial engine with a high spool has a new low spool with a low pressure turbine that drives a low pressure compressor using exhaust gas from the high pressure turbine, and where the new low pressure compressor delivers compressed air through a new compressed air line to the high pressure compressor through a new inlet added to the high pressure compressor. The old electric generator is replaced with a new generator having around twice the electrical power production. One or more stages of vanes and blades are removed from the high pressure compressor to optimally match a pressure ratio split. Closed loop cooling of one or more new stages of vanes and blades in the high pressure turbine is added and the spent cooling air is discharged into the combustor.

Jones, Russell B.↗

Sub-Doppler laser cooling of potassium atoms

We investigate the sub-Doppler laser cooling of bosonic potassium isotopes, whose small hyperfine splitting has so far prevented cooling below the Doppler temperature. We find instead that the combination of a dark optical molasses scheme that naturally arises in this kind of system and an adiabatic ramping of the laser parameters allows us to reach sub-Doppler temperatures for small laser detunings. We demonstrate temperatures as low as 25{+-}3 {mu}K and 47{+-}5 {mu}K in high-density samples of the two isotopes {sup 39}K and {sup 41}K, respectively. Our findings should find application to other atomic systems.

74 ATOMIC AND MOLECULAR PHYSICS↗

Direct Evaporative Precooling Model and Analysis: Development and Simulations of an Improved Algorithm for Import into EnergyPlus and Applications to Commercial Buildings in the United States

Evaporative condenser pre-cooling expands the availability of energy saving, cost effective technology options (market engagement) and serves to broaden the range of options in upcoming codes and equipment standards (impacting regulation). Commercially available evaporative pre-coolers provide a low cost retrofit for existing packaged rooftop units, commercial unitary split systems, and air cooled chillers. We map the impact on energy savings and peak energy reduction in three building types (medium office, secondary school, and supermarket) in 16 locations with four levels of pad effectiveness and show the effect for HVAC systems using either refrigerants R22 or R410A (See Section 5.4). EnergyPlus simulations are conducted with an improved algorithm for estimating the condenser pre-cooling wet bulb efficiency. EnergyPlus version 5.0.0 provides an option for a curve-fit form of calculating evaporative cooling efficiency (currently available only for evaporative pads used for space cooling, not condenser precooling). This option requires a large body of empirical data to obtain the 11 parameters required in the polynomial equation and, being a general curve fit, it is also not physically meaningful. Our study departs from this approach by presenting an alternative mathematical model that is physically intuitive, simpler in form, and provides better agreement with manufacturer’s data. In this report, we describe the simpler algorithm and provide the metrics that show how it is an improvement over the algorithm used in EnergyPlus version 5.0.0. We then generate performance values that can be directly input into EnergyPlus for simulations. By this process, we examine the annual and peak energy reductions of three building types (medium office, secondary school and supermarket) in 16 locations within the U.S. These three building types were chosen because they have distinctive loads, zones, and equipment. In addition to performing the requisite calculations, computer algorithms were developed for use with EnergyPlus to simulate the performance of commercial units under a variety of operating parameters. Performance maps were generated and estimated energy savings and peak demand reductions were calculated. Performance curves that were used in these EnergyPlus simulations were shared with the National Renewable Energy Laboratory (NREL) and with the Florida Solar Energy Center (FSEC) for possible inclusion in the next update to EnergyPlus.

air conditioner↗

A Possible Liquid–Liquid Transition in a Ga–In Melt Introduced into an Opal Matrix

The temperature evolution of the Ga{sub 94}In{sub 6} liquid alloy introduced into an opal matrix has been studied by the NMR method in the temperature range 300–155 K. The temperature dependences of the position and the intensity of the NMR signals from {sup 71}Ga, {sup 69}Ga, and {sup 115}In isotopes have been measured upon cooling and heating of the nanocomposite. The {sup 71}Ga NMR line has been observed to be split into two components on cooling below 176 K with a transfer of the intensity to the high-frequency component. The results demonstrate an induced by nanoconfinement shift of the eutectic point in the alloy and the liquid–liquid phase transition in the indium depleted part of the melt.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Split radiator design for heat rejection optimization for a waste heat recovery system

A cooling system provides improved heat recovery by providing a split core radiator for both engine cooling and condenser cooling for a Rankine cycle (RC). The cooling system includes a radiator having a first cooling core portion and a second cooling core portion. An engine cooling loop is fluidly connected the second cooling core portion. A condenser of an RC has a cooling loop fluidly connected to the first cooling core portion. A valve is provided between the engine cooling loop and the condenser cooling loop adjustably control the flow of coolant in the condenser cooling loop into the engine cooling loop. The cooling system includes a controller communicatively coupled to the valve and adapted to determine a load requirement for the internal combustion engine and adjust the valve in accordance with the engine load requirement.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Magnetic remanence in Yb{sub 14−x}RE{sub x}MnSb{sub 11} (RE=Tb, Dy, Ho) single crystals

Single crystals of Yb{sub 14−x}RE{sub x}MnSb{sub 11} (x~0.1, 0.4; RE = Tb, Dy, Ho) have been prepared as a solid solution by Sn flux reactions of the elements. They crystallize in the Ca{sub 14}AlSb{sub 11} structure type in the I4{sub 1}/acd space group. The RE{sup 3+}preferentially substitutes on the Yb(1) site which is the smallest volume Yb containing polyhedron. In the case of Ho{sup 3+}, a small amount of Ho{sup 3+} also substitutes on the Yb(4) site. The ferromagnetic ordering temperature of Yb{sub 14}MnSb{sub 11} is reduced from 53 K to 41 K as x increases and dependent on the identity of the RE. This is attributed to the reduction in carriers and reduced screening of the Mn{sup 2+} local moment. The effective moments, μ{sub eff,} agree well with the calculated moments assuming the RE substitutes as a trivalent cation. The largest coercive field is observed for RE = Dy (1000 Oe). For the maximum x of Yb{sub 14−x}RE{sub x}MnSb{sub 11} there are enough carriers for the Ruderman-Kittel-Kasuya-Yosida (RKKY) mechanism of magnetic coupling via conduction electrons to still be valid in describing the ferromagnetic ordering. - Graphical abstract: Field dependent susceptibility loops revealed magnetic remanence in these materials, which has not been previously observed in Yb{sub 14}MnSb{sub 11} compounds. The coercive field increases with the strength of the paramagnetic moment for the substituting rare earth and the amount of the rare earth that is substituted. Display Omitted - Highlights: • Yb{sub 14−x}RE{sub x}MnSb{sub 11} (RE=Tb, Dy, & Ho) were synthesized with x~0.2 and x~0.4. • Tb, Dy, & Ho preferentially substitute on the Yb(1) site. • Samples with the largest x and largest RE moment have the largest coercive field. • There is a split between zero field cooled and field cooled susceptibility.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Performance of 3 cm 3 ion trap vacuum package sealed for 10 years

Miniature atomic clocks based on the interrogation of the ground state hyperfine splitting of buffer gas cooled ions confined in radio frequency Paul traps have shown great promise as high precision prototype clocks. We report on the performance of two miniature ion trap vacuum packages after being sealed for as much as 10 years. We find the lifetime of the ions within the trap has increased over time for both traps and can be as long as 50 days. We form two clocks using the two traps and compare their relative frequency instability one with another to demonstrate a short-term instability of 5×10 -13 $τ$ -1/2 integrating down to 1×10 -14 after 2 ks of integration. The trapped ion lifetime and clock instability demonstrated by these miniature devices despite only being passively pumped for many years represents a critical advance toward their proliferation in the clock community.

74 ATOMIC AND MOLECULAR PHYSICS↗

Modelling Nuclear Thermal Propulsion Reactor Expander Cycle Startup Transients

As the interest in nuclear thermal propulsion grows, the need for high fidelity and comprehensive models of the system increases. An expander cycle model was developed using RELAP-7 for the thermal-hydraulic performance and Griffin to provide the power level using a point kinetics approximation, for a reference NTP system. The tank and pump are approximated using boundary conditions. Flow is split between the moderator cooling channels flow path and the regenerative cooling/reflector cooling channels flow path. The flow recombines before entering the turbine and the fuel cooling channels. The turbine pressure ratio is maintained at 1.44 using a PID controller. A startup transient was simulated and shows the capability of the model to run from low temperature and pressures to nominal conditions.

33 ADVANCED PROPULSION SYSTEMS↗

Modelling Nuclear Thermal Propulsion Reactor Expander Cycle Startup Transients

As the interest in nuclear thermal propulsion grows, the need for high fidelity and comprehensive models of the system increases. An expander cycle model was developed using RELAP-7 for the thermal-hydraulic performance and Griffin to provide the power level using a point kinetics approximation, for a reference NTP system. The tank and pump are approximated using boundary conditions. Flow is split between the moderator cooling channels flow path and the regenerative cooling/reflector cooling channels flow path. The flow recombines before entering the turbine and the fuel cooling channels. The turbine pressure ratio is maintained at 1.44 using a PID controller. A startup transient was simulated and shows the capability of the model to run from low temperature and pressures to nominal conditions.

33 ADVANCED PROPULSION SYSTEMS↗

Analysis of operator splitting errors for near-limit flame simulations

High-fidelity simulations of ignition, extinction and oscillatory combustion processes are of practical interest in a broad range of combustion applications. Splitting schemes, widely employed in reactive flow simulations, could fail for stiff reaction–diffusion systems exhibiting near-limit flame phenomena. The present work first employs a model perfectly stirred reactor (PSR) problem with an Arrhenius reaction term and a linear mixing term to study the effects of splitting errors on the near-limit combustion phenomena. Analysis shows that the errors induced by decoupling of the fractional steps may result in unphysical extinction or ignition. The analysis is then extended to the prediction of ignition, extinction and oscillatory combustion in unsteady PSRs of various fuel/air mixtures with a 9-species detailed mechanism for hydrogen oxidation and an 88-species skeletal mechanism for n-heptane oxidation, together with a Jacobian-based analysis for the time scales. The tested schemes include the Strang splitting, the balanced splitting, and a newly developed semi-implicit midpoint method. Results show that the semi-implicit midpoint method can accurately reproduce the dynamics of the near-limit flame phenomena and it is second-order accurate over a wide range of time step size. For the extinction and ignition processes, both the balanced splitting and midpoint method can yield accurate predictions, whereas the Strang splitting can lead to significant shifts on the ignition/extinction processes or even unphysical results. With an enriched H radical source in the inflow stream, a delay of the ignition process and the deviation on the equilibrium temperature are observed for the Strang splitting. On the contrary, the midpoint method that solves reaction and diffusion together matches the fully implicit accurate solution. The balanced splitting predicts the temperature rise correctly but with an over-predicted peak. For the sustainable and decaying oscillatory combustion from cool flames, both the Strang splitting and the midpoint method can successfully capture the dynamic behavior, whereas the balanced splitting scheme results in significant errors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Complex transport and magnetism in inhomogeneous mixed valence Ce 3 Ir 4 Ge 13

We report the discovery of Ce 3 Ir 4 Ge 13 , a Remeika phase with a complex array of structural, electronic, and magnetic properties. In this work, our single crystal x-ray diffraction measurements show that Ce 3 Ir 4 Ge 13 forms in the tetragonally distorted $I4_1/amd$ space group, which has three distinct rare earth sites. The electrical resistivity is almost temperature independent over three decades in temperature, from 0.4 K to 400 K, while the Hall coefficient measurements are consistent with a low-carrier semimetal. Magnetic susceptibility measurements reveal an effective moment, $μ^\text{exp}_\text{eff} = 1.87μ_B/$Ce, that falls significantly short of the expected value for Ce 3+ , suggesting that two of the rare earth sites are occupied by magnetic Ce 3+ while the third is occupied by nonmagnetic Ce 4+ . Upon cooling, Ce 3 Ir 4 Ge 13 first enters a short range magnetically ordered state below $T_\text{SRO}$ = 10 K, marked by a deviation from Curie-Weiss behavior in susceptibility and a broad field-independent heat capacity anomaly. At lower temperatures, we observe a second, sharper peak in the heat capacity at $T^\ast$ = 1.7 K, concurrent with a splitting of the field-cooled and zero-field-cooled susceptibilities. A small resistivity drop at $T^\ast$ suggests a loss of spin disorder scattering consistent with a magnetic ordering or spin freezing transition. Ce 3 Ir 4 Ge 13 is therefore a rare example of an inhomogeneous mixed valence compound with a complex array of thermodynamic and transport properties.

36 MATERIALS SCIENCE↗

Increasing the Number of Installed Residential Heat Pump Water Heaters in the USA Through Improved Technology and Utility Programs

Heat pump water heaters (HPWHs) offer an efficient alternative to electric resistance water heaters, but they suffer from limited market penetration. This paper reviews the current state of HPWHs in the USA, focusing on technology developments and programs to increase adoption. What technological improvements are needed to make HPWHs a good fit in more homes? Additionally, what are the best ways of promoting HPWHs to consumers? Improved communication and controls will allow HPWHs to provide demand response and follow dynamic utility rates. To enable fuel-switching, HPWHs are being developed that only need a standard 120V outlet. Split HPWHs can alleviate the cooling and noise that limit the use of HPWHs in small homes, multifamily buildings, and cold climates. Additionally, new utility programs aim to train installers and provide incentives to distributors to increase the number of HPWHs installed. Some utilities offer novel incentive programs that have led to increased customer uptake. Those advances, coupled with improved controls for load shifting and new products such as split HPWHs and HPWHs that can run on 120V power, may finally move the market forward.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Replacing Resistance Heating with Mini-Split Heat Pumps: Sharon, Connecticut (Fact Sheet)

Mini-split heat pumps can provide space heating and cooling in many climates and are relatively affordable. These and other features make them potentially suitable for retrofitting into multifamily buildings in cold climates to replace electric resistance heating or other outmoded heating systems. This report investigates the suitability of mini-split heat pumps for multifamily retrofits. Various technical and regulatory barriers are discussed and modeling was performed to compare long-term costs of substituting mini-splits for a variety of other heating and cooling options. A number of utility programs have retrofit mini-splits in both single family and multifamily residences. Two such multifamily programs are discussed in detail.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mini-Split Heat Pumps Multifamily Retrofit Feasibility Study

Mini-split heat pumps can provide space heating and cooling in many climates and are relatively affordable. These and other features make them potentially suitable for retrofitting into multifamily buildings in cold climates to replace electric resistance heating or other outmoded heating systems. This report investigates the suitability of mini-split heat pumps for multifamily retrofits. Various technical and regulatory barriers are discussed and modeling was performed to compare long-term costs of substituting mini-splits for a variety of other heating and cooling options. A number of utility programs have retrofit mini-splits in both single family and multifamily residences. Two such multifamily programs are discussed in detail.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mini-Split Heat Pumps Multifamily Retrofit Feasibility Study

Mini-split heat pumps can provide space heating and cooling in many climates and are relatively affordable. These and other features make them potentially suitable for retrofitting into multifamily buildings in cold climates to replace electric resistance heating or other outmoded heating systems. This report investigates the suitability of mini-split heat pumps for multifamily retrofits. Various technical and regulatory barriers are discussed and modeling was performed to compare long-term costs of substituting mini-splits for a variety of other heating and cooling options. A number of utility programs have retrofit mini-splits in both single family and multifamily residences. Two such multifamily programs are discussed in detail.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dielectric and magnetic investigations of GaFeO{sub 3} single crystals

Structural, dielectric and magnetic properties have been investigated for the polar ferrimagnet, GaFeO{sub 3} single crystals grown by optical floating zone technique. Phase formation was confirmed from X-ray diffraction. Hopping conduction mechanism of Fe{sup 2+} ions and oxygen vacancies contribute to the electric polarization and dielectric constant of the material. Disorderness in the cation site gives rise to the magnetic ordering and the splitting in the zero field cooled (ZFC) and field cooled (FC) magnetization curves reveals the movement of the domain walls.

36 MATERIALS SCIENCE↗