Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spectral measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Performance of plane wavefront Fizeau interferometers in power spectral density measurements with tilted plane optics

Binary pseudo-random array (BPRA) test samples are useful devices for calibrating the instrument transfer function (ITF) of Fizeau interferometers, interferometric microscopes, and other optical and non-optical surface and wavefront metrology instruments. The intrinsic white noise character of the power spectral density (PSD) function of the BPRA pattern simplifies the extraction of the ITF from the measured PSD. The ITF determined in a dedicated calibration experiment can be used to reconstruct the surface height profile from the measured data, effectively enhancing the instrument’s spatial resolution. For a high confidence reconstruction procedure, a reliable analytical model of the IFT is desirable. Usually, the model accounts for the contributions to the ITF related the imperfections of the instrument’s optical and detector systems. Here, we experimentally demonstrate that in the case of surface height metrology with Fizeau interferometers, the PSD measurements and, therefore, the efficacy of the ITF calibration of the tool, are strongly affected by the instrument data acquisition and processing procedures, as well as by the shape of the optic under test and its alignment with respect to the interferometer.

Yashchuk, V V↗

Estimating snow cover from high-resolution satellite imagery by thresholding blue wavelengths

We report the extent and duration of snow cover, a critical component of the hydrologic cycle and the global climate system, is expected to shift dramatically under climate change. Therefore, developing high-resolution assessments of snow cover change is crucial for estimating the impact of changing snow cover on watershed and ecosystems processes in cold regions. Remote sensing tools provide a powerful method for mapping snow-covered area (SCA) across a landscape. The most common method for estimating SCA utilizes the normalized difference snow index (NDSI), which relies on spectral measurements in the shortwave-infrared wavelengths (SWIR). NDSI can effectively estimate catchment- to regional-scale SCA, but it cannot be used to assess fine-scale SCA because of current limitations on the spatial resolution of satellite-derived SWIR measurements. Here, we map SCA using a threshold of blue wavelengths and high-resolution satellite imagery. The thresholding method, which we call the Blue Snow Threshold algorithm (BST), has previously been used with digital camera imagery. We refine and automate the algorithm for use with cloud-free high-resolution satellite imagery and find that the BST can be used to assess fine-scale SCA. For validation, we compared BST-derived estimates of SCA to a) airborne lidar surveys, b) Landsat fractional SCA, and c) snow disappearance dates from Snow Telemetry (SNOTEL) stations. When compared to airborne lidar surveys of SCA, the BST predicted SCA had a range of F-scores between 0.81 and 0.94 in four study areas in California and Colorado. We also found general agreement between SCA and snow disappearance at multiple SNOTEL sites across the western United States. Given the relatively recent availability of high-resolution satellite imagery with spectral measurements in the visible wavelengths but lacking in SWIR, the BST offers a reliable and easy-to-apply tool for examining fine-scale snow-related processes.

54 ENVIRONMENTAL SCIENCES↗

SPECTER: an instrument concept for CMB spectral distortion measurements with enhanced sensitivity

Deviations of the cosmic microwave background (CMB) energy spectrum from a perfect blackbody uniquely probe a wide range of physics, ranging from fundamental physics in the primordial Universe (μ-distortion) to late-time baryonic feedback processes (y-distortion). While the y-distortion can be detected with a moderate increase in sensitivity over that of COBE/FIRAS, the ΛCDM-predicted μ-distortion is roughly two orders of magnitude smaller and requires substantial improvements, with foregrounds presenting a serious obstacle. Within the standard model, the dominant contribution to μ arises from energy injected via Silk damping, yielding sensitivity to the primordial power spectrum at wavenumbers k ≈ 1-10 4 Mpc -1 . Here, we present a new instrument concept, SPECTER, with the goal of robustly detecting μ. The instrument technology is similar to that of LiteBIRD, but with an absolute temperature calibration system. Using a Fisher approach, we optimize the instrument's configuration to target μ while marginalizing over foreground contaminants. Unlike Fourier-transform-spectrometer-based designs, the specific bands and their individual sensitivities can be independently set in this instrument, allowing significant flexibility. We forecast SPECTER to observe the ΛCDM-predicted μ-distortion at ≈ 5σ (10σ) assuming an observation time of 1 (4) year(s) (corresponding to mission duration of 2 (8) years), after foreground marginalization. Our optimized configuration includes 16 bands spanning 1–2000 GHz with ∼degree-scale angular resolution at ∼ 150 GHz and 1100 total detectors. SPECTER will additionally measure the y-distortion at sub-percent precision and its relativistic correction at percent-level precision, yielding tight constraints on the total thermal energy and mean temperature of ionized gas.

CMBR experiments↗

Study of shortwave spectra in fully 3D environment: synergy between scanning radars and spectral radiation measurements (final Report)

Overview of 3D atmospheric radiative transfer in cloudy atmosphere for Reports on Progress in Physics. We surveyed the 3D atmospheric radiative transfer literature over the past 50 years and identify three concurrent and intertwining themes: first, how to assess the damage (bias) caused by 3D effects in the operational 1D radiative transfer models? Second, how to mitigate this damage? Third, can we exploit 3D radiative transfer phenomena to invent new observation methods and technologies? Two equally important application areas for atmospheric radiative transfer in general, and 3D in particular, were identified: broadband radiative energy budget estimation and wavelength-specific optical remote sensing signal modeling. As illustrations, both satellite and ARM observations were highly used.

54 ENVIRONMENTAL SCIENCES↗

Spectral Flux Measurements on SNS Direct Geometry Spectrometers at IRP-2 End-of-Life

The Inner Reflector Plug (IRP) of the Spallation Neutron Source (SNS) was replaced during the SNS shutdown period beginning 25 November 2025. This IRP, IRP-2, was first placed in service in May 2018, and was in use for 42.5 GW-hrs of operation, somewhat longer than its original design life of 30 GW-hrs, or even a refined estimate of 33 GW-hrs for the water moderator poison plate and 39 GW-hrs on the decoupled-poisoned hydrogen moderator decoupler (Gallmeier, Lu, and Iverson 2018). The time-integrated power history for IRP-2 is tracked in Figure 1.

43 PARTICLE ACCELERATORS↗

Identification of Distorted Gamma-Ray Signature Patterns Using Digital Filtering and Auto-Associative Memory Implemented with a Hopfield Neural Network

The detection and identification of radioactive sources in search applications involve analyzing passive gamma-ray emissions from high-level radioactive materials. This process uses a mobile detector-spectrometer in a complex field test environment. Recently, the use of artificial intelligence for gamma-ray spectrum analysis has shown promising results. However, challenges persist in identifying isotopic signatures from spectral measurements that may be distorted due to source shielding, random variations in natural radioactive background, or insufficient measurement time to obtain clear spectral lines. Here, this paper presents a novel intelligent signature recognition method that combines digital filtering techniques with an artificial Hopfield Neural Network (HNN). The HNN leverages auto-associative memory to store training sample patterns and match them with incoming gamma spectra from distorted sources. It restores the testing sources’ measurements by finding the closest matching signature patterns in the spectral library. Before HNN recognition, the measured spectrum undergoes preprocessing with a digital image filter to reduce fluctuations. Performance of the proposed method is evaluated using a set of gamma-ray spectra measured with a sodium iodide detector. The data collected include measurements from six pure samples: 241 Am, 60 Co, 137 Cs, 192 Ir, 239 Pu, and 235 U, which are used for training and validation (i.e. six cases). Additionally, the data set contains 24 distorted synthesized sources with various fluctuating backgrounds. Test results demonstrate the potential of the proposed method to accurately recognize the correct isotope with high precision, achieving an accuracy rate exceeding 85%. Furthermore, the proposed method exhibits superior performance compared to the conventional multiple regression fitting and simple feedforward neural network methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of L-shell emission from mid-Z targets under non-LTE conditions using Transmission Grating Spectrometer and DANTE power diagnostics

In this work, we present the measurement of L-band emission from buried Sc/V targets in experiments performed at the OMEGA laser facility. The goal of these experiments was to study non-local thermodynamic equilibrium plasmas and benchmark atomic physics codes. The L-band emission was measured simultaneously by the time resolved DANTE power diagnostic and the recently fielded time integrated Soreq-Transmission Grating Spectrometer (TGS) diagnostic. The TGS measurement was used to support the spectral reconstruction process needed for the unfolding of the DANTE data. The Soreq-TGS diagnostic allows for broadband spectral measurement in the 120 eV–2000 eV spectral band, covering L- and M-shell emission of mid- and high-Z elements, with spectral resolution λ/Δλ = 8–30 and accuracy better than 25%. The Soreq-TGS diagnostic is compatible with ten-inch-manipulator platforms and can be used for a wide variety of high energy density physics, laboratory astrophysics, and inertial confinement fusion experiments.

Fraenkel, M. (ORCID:0000000291939544)↗

Modeling Reference Cell Performance Using Measured and Modeled Spectral Data

The performance of several silicon-based reference cells is examined under clear skies on a horizontal and two-axis tracking surface during the winter of 2022. The ratio of the calculated reference cell output to the measured reference cell output is examined. For each reference cell, when using the measured spectral data, the ratio of the estimated to measured output varies by less than +/-0.6% at the P95 level. The analysis was also done using modeled spectral values obtained from the Bird spectrl2 model. The ratio between the estimated reference cell output using the modeled spectral values to the measured reference cell output varies by +/-1.1% at the P95 level.

angle of incidence↗

Methods for estimating X-ray machine output through measurement and simulation

We report ball grid arrays are increasingly being applied in the electronics industry and may require X-ray inspection to ensure the integrity and correct placement of solder pins. However, as the architecture of integrated circuits continues to narrow while simultaneously growing more complex, the risk of electronic failure due to radiation damage increases. While medical X-ray devices have been held to high standards and are repeatedly shown to be well characterized, devices used for electronic inspection are often lacking detailed characterization. This study presents unique methods to solve for important properties in X-ray inspection devices such as source to object distance and energy spectrum. This information can then be applied to Monte Carlo models to achieve better overall dose estimates to electronics, which will lead to superior manufactured products. Since X-ray devices can vary greatly in source characteristics, this work investigates spectral measurement and Monte Carlo representation of three X-ray devices. For a Philips SRO 33 100 medical diagnostic device, the spectral output followed expected trends given by the prediction software SpekCalc and Spektr. For the Dage XD7500NT, direct measurement showed a spectral artifact that through the use of Gafchromic films, was shown to be a contributing effect in the dose output. For the Rad Source RS1800, a high powered irradiation device, direct spectral measurement was not achieved. However, a Monte Carlo model using an assumed spectra was found to match ion chamber measurements to a high degree.

47 OTHER INSTRUMENTATION↗

Ultrabroadband flying-focus using an axiparabola-echelon pair

Flying-focus pulses promise to revolutionize laser-driven secondary sources by decoupling the trajectory of the peak intensity from the native group velocity of the medium over distances much longer than a Rayleigh range. Previous demonstrations of the flying focus have either produced an uncontrolled trajectory or a trajectory that is engineered using chromatic methods that limit the duration of the peak intensity to picosecond scales. Here we demonstrate a controllable ultrabroadband flying focus using a nearly achromatic axiparabola-echelon pair. Spectral interferometry using an ultrabroadband superluminescent diode was used to measure designed super- and subluminal flying-focus trajectories and the effective temporal pulse duration as inferred from the measured spectral phase. The measurements demonstrate that a nearly transform- and diffraction-limited moving focus can be created over a centimeter-scale—an extended focal region more than 50 Rayleigh ranges in length. This ultrabroadband flying-focus and the novel axiparabola-echelon configuration used to produce it are ideally suited for applications and scalable to >100 TW peak powers.

47 OTHER INSTRUMENTATION↗

Leaf reflectance, leaf transmittance and sky irradiance, at four sites in Panama, 2022

Paired leaf reflectance and transmittance data measured in Panama, at the Parque Natural Metropolitano (PNM), on Barro Colorado Island (BCI), at the San Lorenzo canopy crane site (SLZ), and in Gamboa, Panama from January to April 2022. Measurements were made on leaves from 57 different tree, shrub and liana species, from sunlit canopy and understory locations. Bark reflectance was also measured on the trunks of common tree species at the PNM and SLZ sites. Also included are irradiance measurements and leaf area index (LAI) from eight vertical profiles at PNM. The aim of these data was to refine our understanding of vertical trait and environmental variation in tropical forests, and to improve models which can predict leaf traits from leaf contact spectral measurements. All spectral data and metadata are presented in .csv files and complete instrument output are included in .zip folders. Protocol details are provided as pdf documents. In addition to spectral data described here, some of these samples were also used for measurement of leaf gas exchange, carbon and nitrogen content, and leaf mass per unit leaf area (LMA) these data can be cross linked using the unique sample ID and are provided in separate related data packages.

54 ENVIRONMENTAL SCIENCES↗

On the Accuracy of the ALMA Flux Calibration in the Time Domain and across Spectral Windows

A diverse array of science goals requires accurate flux calibration of observations with the Atacama Large Millimeter/submillimeter array (ALMA); however, this goal remains challenging due to the stochastic time-variability of the “grid” quasars ALMA uses for calibration. In this work, we use 343.5 GHz (Band 7) ALMA Atacama Compact Array observations of four bright and stable young stellar objects over seven epochs to independently assess the accuracy of the ALMA flux calibration and to refine the relative calibration across epochs. The use of these four extra calibrators allows us to achieve an unprecedented relative ALMA calibration accuracy of ~3%. On the other hand, when the observatory calibrator catalog is not up to date, the Band 7 data calibrated by the ALMA pipeline may have a flux calibration poorer than the nominal 10%, which can be exacerbated by weather-related phase decorrelation when self-calibration of the science target is either not possible or not attempted. We also uncover a relative flux calibration uncertainty between spectral windows of 0.8%, implying that measuring spectral indices within a single ALMA band is likely highly uncertain. We thus recommend various methods for science goals requiring high flux accuracy and robust calibration, in particular, the observation of additional calibrators combined with a relative calibration strategy, and observation of solar system objects for high absolute accuracy.

79 ASTRONOMY AND ASTROPHYSICS↗

SCEC/USGS Community Stress-Drop Validation Study: How Spectral Fitting Approaches Influence Measured Source Parameters

Spectral source parameters used to estimate an earthquake’s stress drop (⁠Δσ⁠) can vary significantly across measurement approaches. The Statewide California Earthquake Center/U.S. Geological Survey Community Stress‐Drop Validation Study was initiated to compare source parameter estimates, focusing initially on a dataset from the 2019 Ridgecrest earthquake sequence. As part of that validation effort, here we focus on one potential source of uncertainty: whether spectral fitting approaches alone, applied to a common set of spectra from the 2019 Ridgecrest sequence result in different source parameter estimates. By using a common set of benchmark spectra analyzed across a consistent frequency band of 1–40 Hz, we eliminate many sources of variability. A subgroup of validation study participants volunteered to estimate the low‐frequency displacement (⁠Ω 0 ⁠) and corner frequency (⁠ƒ c ⁠) by fitting a smooth function to benchmark displacement spectra. Participants used linear‐ or log‐sampled spectra, assumed a Brune or Boatwright spectral model, and applied different misfit criteria. We compare 17 approaches used to estimate ⁠Ω 0 ⁠, ƒ c ⁠, and Δσ for 54 earthquake spectra. Our results reveal that 35% of events have Δσ estimates within a factor of two, whereas others exhibit variations exceeding an order of magnitude. The variability in and can largely be attributed to whether a spectrum is consistent with the smooth function of an idealized simple crack model. The trade‐off between Ω 0 and ƒ c may be more pronounced when using linearly sampled spectra, as higher frequency spectral bumps control the fits. As expected, methods that assumed a Boatwright model tended to have lower Ω 0 and somewhat higher ƒ c compared to those assuming a Brune model, although resulting Δσ estimates are similar. Finally, when compared to the overall validation study results, the fitting approach alone may account for between 5% and 90% (25% on average) of the total variability in spectral Δσ⁠.

58 GEOSCIENCES↗

Edge fluctuation measurements in EDA H-mode and QCE plasmas in ASDEX Upgrade using the correlation electron cyclotron emission diagnostic

The requirement of a plasma solution without large edge-localized modes (ELMs) for future fusion devices motivates the study of plasmas without Type I ELMs. The enhanced D–α (EDA) and quasi-continuous exhaust (QCE) scenarios are two such Type I ELM free plasmas, but their underlying physics principles are not fully understood. A database of EDA and QCE plasmas from ASDEX Upgrade was compiled and analyzed using the correlation electron cyclotron emission diagnostic in order to study differences between properties of the quasi-coherent mode (QCM) between these two regimes. Investigations into measured spectral properties of the QCM, radiated temperature fluctuations δT rad /T rad , and radial correlation lengths L c showed no differences between the two regimes. Spectral properties using the cross-power spectral density, G xy were similar between regimes, with the values measured to be a central frequency, $f$ $QCM$ ≈ 20 - 50 kHz; spectral width, Δ $f$ ≈ 5 - 40 kHz; δT rad /T rad ≈ 4-6%; and L c ≈ 1-2 cm. Investigations into a quantity representing the relative bandwidth Δ$f$/$f$ $QCM$ revealed differences between EDA and QCE plasmas when plotted radially, suggesting some type of interaction between the QCM in QCE plasmas with the surrounding broadband turbulence that is not present in EDA phases. Additionally, investigations into various drive terms for hypothesized instability drivers for the QCM are performed showing no difference in the parameter spaces of collisionality and the ion temperature, electron temperature, or electron pressure scale lengths between each regime indicating that there is no observable difference between the drive behind the QCM in each regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First Measurement of Z Opacity Sample Evolution near Solar Interior Conditions Using Time-Resolved Spectroscopy

Opacity model differences with Fe opacity measurements at high temperature (T>1⁢8⁢0 eV ) and high electron density (𝑛 𝑒 >3×10 22 cm −3 ) at nearly solar interior conditions have remained unresolved [Bailey et al., Nature 517, 56 (2015) and Nagayama et al., Phys. Rev. Lett. 122, 235001 (2019)]. Systematic errors from temporal gradients are one hypothesis for the discrepancy. Past data recorded on x-ray film provided spectral measurements over a time determined by the 2.8-ns backlighter duration. Here, we present the first measurements of opacity sample temporal evolution using novel hCMOS ultrafast x-ray camera technology. The measured conditions, measured backlighter time history, and modeled opacities are used to show that temporal gradients do not resolve the model-data discrepancy. The methods demonstrated provide potential advantages, including opacities at more extreme conditions, spectral line shift measurements, and improved measurements at other facilities.

atomic spectra↗

Ocean surface radiation measurement best practices

Ocean surface radiation measurement best practices have been developed as a first step to support the interoperability of radiation measurements across multiple ocean platforms and between land and ocean networks. This document describes the consensus by a working group of radiation measurement experts from land, ocean, and aircraft communities. The scope was limited to broadband shortwave (solar) and longwave (terrestrial infrared) surface irradiance measurements for quantification of the surface radiation budget. Best practices for spectral measurements for biological purposes like photosynthetically active radiation and ocean color are only mentioned briefly to motivate future interactions between the physical surface flux and biological radiation measurement communities. Topics discussed in these best practices include instrument selection, handling of sensors and installation, data quality monitoring, data processing, and calibration. It is recognized that platform and resource limitations may prohibit incorporating all best practices into all measurements and that spatial coverage is also an important motivator for expanding current networks. Thus, one of the key recommendations is to perform interoperability experiments that can help quantify the uncertainty of different practices and lay the groundwork for a multi-tiered global network with a mix of high-accuracy reference stations and lower-cost platforms and practices that can fill in spatial gaps.

54 ENVIRONMENTAL SCIENCES↗

High-speed fiber-based spectrometer for plasma Thomson scattering

Here we present a novel concept for a Thomson scattering diagnostic, based on a high-speed fiber optic spectrometer. The high-speed fiber optic spectrometer presented here translates a spectral measurement from the frequency domain into the time domain, thus requiring the use of only a single photodetector for spectral acquisition. The high temporal precision offered by the instrument gives rise to a number of advantages over traditional spectrometers, such as nearly background-free measurements and multiple uses of the same injected beam. Multiple uses of the same beam would enable greatly increased measurement rates, in the range of 10–100 MHz. The spectral range and resolution of the fiber spectrometer can be easily tailored to be optimized for the light source and experimental conditions by selecting different lengths of fiber, thus allowing for the proposed technique to exhibit high dynamic range when measuring many points simultaneously. Finally, due to the temporal separation of the background from the signal, these improvements are possible without the need for increased average input laser power.

47 OTHER INSTRUMENTATION↗

Spectral characterization of an SPDC source with a fast broadband spectrometer

Knowing the properties of single photons produced in a Spontaneous Parametric Down-Conversion (SPDC) source can be crucial for specific applications and uses. In particular, the spectral properties are of key relevance. Here, we investigate a commercial SPDC source using our fast broadband spectrometer. Our analysis is a valid method for other SPDC sources, as well as other single-photon generation techniques, thus providing a good example of how to use this spectrometer design. We calibrate the spectrometer using known lines of the argon emission spectrum. We show that the two down-converted photons from the SPDC source have different spectral properties depending on the pump power, and under which condition we measured spectrally similar down-converted photons. Finally, we were able to reconstruct and investigate the spectral information for the pump photon.

79 ASTRONOMY AND ASTROPHYSICS↗