Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spectral emissivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Multi-delay coherence imaging spectroscopy optimized for ion temperature measurements in the divertor plasma of the Wendelstein 7-X stellarator

A new coherence imaging spectroscopy (CIS) diagnostic optimized to measure the C 2+ impurity ion temperature T i spatial distribution in the divertor plasma of the W7-X stellarator is designed, tested, and validated. Using CIS to obtain T i in the edge of magnetically confined plasmas has historically been challenging because Doppler broadening and Zeeman splitting have comparable effects on the shape of spectral emission lines. To distinguish between these two mechanisms, a novel approach to birefringent crystal design is employed to minimize the diagnostic’s sensitivity to Zeeman splitting. The recently developed pixelated multi-delay CIS approach is also used to obtain four times as much spectral information as traditional CIS approaches. The T i -optimized CIS diagnostic is validated in a long-pulse W7-X plasma by comparison with a high-resolution spectrometer whose sightlines overlap with the CIS field of view. The CIS and spectrometer T i profiles have the same shape and agree to within 10% on average and 25% in the worst case. Images of the T i distribution near the divertor show toroidally elongated bands aligned with the magnetic field, with T i ranging between 10 and 40 eV.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Franck-Condon electron emission from polar semiconductor photocathodes

An analytical formulation of (optical-)phonon-mediated and momentum-resonant Franck-Condon emission of photoexcited electrons from polar semiconductors is shown to be very consistent with (i) the observed emission properties of a cesiated Ga⁢As⁢(001) photocathode at 808 nm [J. Phys. D: Appl. Phys. 54, 205301 (2021)] and (ii) the measured spectral emission properties of a Ga⁢N(0001) photocathode from just below its bandgap energy to 5 eV. The theoretical analysis in the parabolic band approximation predicts the form of both the quantum efficiency and mean transverse energy of photoemission as a function of the photocathode’s electron affinity and the electron temperature in the vicinity of its emission face. The good agreement between theory and experimental data also suggests that sub-10-nm rms surface roughness effects are not significant for polar semiconductor photocathodes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Filterscope Techniques for Parasitic Signal Screening

Here, the filterscope diagnostic uses bandpass filters and photomultiplier tubes (PMTs) to detect specific spectral emission lines. A filterscope was used to measure the W I 400.88 nm line emission as a function of ion energy on the Radio Frequency Plasma Interaction Experiment (RF PIE) for the purpose of assessing W erosion on plasma-facing components (PFCs). Different filter techniques are being explored and compared in order to effectively screen out nearby impurity lines, like the Ar II 401.39 nm line. The effectiveness of these techniques is determined by comparing the measurements to a high-resolution 1.0 m Czerny–Turner spectrometer with 0.012 nm spectral resolution. The ability to filter out nearby impurity emissions is useful when imaging PFCs in fusion devices including divertor and antenna guard limiters. Initial results with a helium plasma show little difference between the two techniques at higher bias voltages. In a helium plasma at lower dc bias voltages, a two-filter technique with filters at two separate wavelengths was shown to be more effective at screening out background signals. Data collected with an argon plasma however show the technique with overlapping filters on the line of interest is a closer match to spectrometer data at lower dc bias voltages.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The influence of laser energy on deuterium emission characteristics from a Zircaloy-4 plasma

Laser-produced plasma coupled with optical emission spectroscopy (OES) is a promising technique for detecting certain isotopes, with unique capabilities such as standoff and rapid detection and minimal to no sample preparation requirements. The key figure-of-merit for isotopic analysis using optical spectroscopy tools is the linewidth relative to the isotope shift. Although the isotopes of hydrogen (1H, 2H, and 3H) possess large isotopic shifts (1H–2H ≈ 180 pm, 1H–3H ≈ 240 pm), being a light element, the H transitions are susceptible to various broadening mechanisms in the plasma environment. One of the critical parameters that influence the linewidth of a transition in an LPP is the incident laser energy. In the present study, we evaluated the role of laser energy on plume expansion dynamics, deuterium emission intensity, and linewidth in a nanosecond laser-produced Zircaloy-4 plasma. The changes in 2Hα emission intensity and linewidth were investigated for varying laser fluence and time after plasma onset. Spatially resolved and spatially integrated OES were performed and compared to investigate the emission spectral features and linewidth of 2Hα. Monochromatic two-dimensional time-resolved imaging was also performed to understand the morphology of the deuterium and protium emission relative to all species in the plume. Our results showed that 1Hα and 2Hα emissions predominantly occur closer to the target. Measurements of 2Hα linewidth approached similar values at later times of plasma evolution regardless of the laser energy. The linewidths of the 2Hα transition showed insignificant differences between spatially resolved and spatially integrated measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The motional Stark effect diagnostic for ITER

An overview of the plans for the motional Stark effect (MSE) diagnostic installation on the International Thermonuclear Experimental Reactor (ITER) is presented. The MSE diagnostic uniquely provides spatially localized magnetic field measurements inside the plasma. These are used to constrain equilibrium reconstructions to determine q(r), the safety factor as a function of minor radius. Meeting the system requirements to deliver q-profiles and related quantities with the specified radial resolution of 20 points over the minor radius, 10 ms time resolution, and better than 10% accuracy is challenging. MSE systems observe the D/H-α emission near 656.3 nm from neutral beams. As the beam atoms traverse the magnetic field, B⃗, at high velocity, v⃗, they experience a Lorentz electric field, v⃗×B⃗, which causes the spectral emission to be split and polarized due to the Stark effect. Traditional MSE-LP (line polarization) measurements determine the direction of the magnetic field in the observation volume using polarimetric analysis of the detected light. The harsh conditions of ITER are expected to deposit thin films of contaminants on the first mirror, which would alter the polarization state of reflected light significantly. On ITER, the combination of high magnetic field strength and high energy beams makes the Stark spectrum resolution suitable for the determination of the magnetic field magnitude from the line shift, so this approach has been selected. Every aspect of the measurement system must be planned for the burning plasma environment and carefully analyzed ahead of time. Current status and plans for the system are presented.

Instruments & Instrumentation↗

High-emissivity, thermally robust emitters for high power density thermophotovoltaics

Thermal radiative energy transport is essential for high-temperature energy harvesting technologies, including thermophotovoltaics (TPVs) and grid-scale thermal energy storage. However, the inherently low emissivity of conventional high-temperature materials constrains radiative energy transfer, thereby limiting system performance and technoeconomic viability. Here, in this study, we demonstrate ultrafast femtosecond laser-material interactions to transform diverse materials into near-blackbody surfaces with broadband spectral emissivity above 0.96. This enhancement arises from hierarchically engineered light-trapping microstructures enriched with nanoscale features, effectively decoupling surface optical properties from bulk thermomechanical properties. These laser-blackened surfaces (LaBS) exhibit exceptional thermal stability, retaining high emissivity for over 100 h at temperatures exceeding 1,000°C, even in oxidizing environments. When applied as TPV thermal emitters, Ta LaBS double electrical power output from 2.19 to 4.10 W cm −2 at 2,200°C while sustaining TPV conversion efficiencies above 30%. This versatile, largely material-independent technique offers a scalable and economically viable pathway to enhance emissivity for advanced thermal energy applications.

laser-blackened surfaces↗

The Motional Stark Effect Diagnostic for NSTX-U

This report describes the development of the motional Stark Effect diagnostic for NSTX. The MSE concept relies upon observation of the Balmer-alpha (n=3 to n=2) emission from a neutral hydrogen beam traversing a plasma. As a beam at high velocity, $\vec{ν}$, passes through the magnetic field in the plasma, $\vec{B}$, it experiences in its reference frame a Lorentz electric field, $\vec{E}$ = $\vec{ν}$ x $\vec{B}$. This electric field causes the spectral emission to be split and polarized as described by the Stark effect. The transition is separated into a set of lines in which the line spacing is linearly proportional to the electric field magnitude, and the line polarization is dependent on the electric field direction. Traditionally, MSE has used polarimetry to determine the polarization angle of the light, and related that to the magnetic field pitch angle in the plasma. The MSE diagnostic was developed under high magnetic field ($>$ 1~T) conditions, and the lower fields of recent high-beta experiments such as NSTX posed challenges to the technique. At low magnetic fields Doppler broadening effects mask the Stark effect. With the use of a narrow bandwidth filter MSE measurements at very low magnetic fields have been obtained.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laser induced breakdown spectroscopy of liquid

Chemical composition of liquid phase samples is determined based on laser induced ablation spectroscopy of droplets. An aerosol jet comprising a carrier gas and liquid phase sample droplets, less than about 10 microns in diameter, is formed. An emissive plasma plume is generated from the sample droplets using a pulsed laser to deposit energy at a focal point in the aerosol jet. Light from the plasma plume is gathered with a concave mirror and focused into one end of a fiber optic lightguide. The lightguide can transmit spectral emissions from the plume to a spectrometer/detector which can send wavelength and intensity values to a computer. The computer is operable to determine a liquid sample composition based on the wavelength and intensity values.

Bol'shakov, Alexander A.↗

Biologically Cooling the Planet: A BRISK Approach that Directly Connects the Ground to Deep Space

Climate change is a grave threat to our ability to thrive and prosper on Earth. Accumulation of greenhouse gases in the atmosphere stifle the Earth’s ability to cool itself, which leads to a rise of the average temperature – Global warming. The planetary cooling is exclusively radiative – thermal radiation escapes into cold outer space via a flux of photons at the low-infrared range. The penetration of these photons through Earth’s atmosphere is dictated by atmospheric transparency, which, serendipitously possesses a window centered around the peak of the Plank spectrum for a black body at about room temperature – the average temperature of Earth. This window spanning about 8 --13 μm wavelengths allows most of the photons in this range to escape into the Cosmos carrying our planet’s heat away. The efficiency of this outer heat flux – and thus planet’s cooling ability – can be controlled via emissivity – a function of wavelength which multiplies the fundamental Plank spectrum of a black body at a given temperature. In the presence of non-trivial atmospheric transparency it can be shown that radiative cooling can be enhanced with properly “designed” emissivity function. For the last 100 years, or so, people have been looking into ways to engineer materials to take advantage of such enhancement for various cooling applications, from making ice to cool clothes, and substantial progress has been achieved, including cooling in direct sunlight. The beauty if this approach is that it is entirely passive – no energy input is required. The objective of this project was to investigate whether biological systems possess such advanced cooling capacity, developed via millennia of evolution, to enhance plant’s adaptation to a hot environment, to increase cooling capability, and possibly modulate spectral emissivities on short or long time scales. We wanted to know if BRISK (Biological Radiative Sky Cooling) occurs and to what extent. It is unknown whether biological systems can perform this "spectral redistribution." It is reasonable to expect, however, that they might: in particular, desert plants under high heat stress and arid conditions might evolve this mechanism in order to maintain a tolerable internal temperature. Our intended approach was twofold: extensive literature search and supporting experimental investigations on select plants. We obtained the answers from the former, while the latter proved to be more complicated to perform with required accuracy in the timespan/budget of a small seedling project. After one year of research, we concluded that among the plant species studied there seem to be no evidence of BRISK, but it’s not the end of the story. Our planet’s biosphere is immense, and the evolution is continuing. With our preliminary results and a better understanding of what to look for further discoveries await, considering the accelerated pace of infrared imaging and spectroscopy technology development, from microscopic to satellite-based studies of plants and canopies. In the end, Earth’s energy balance is ultimately tied to radiative cooling so that further investigation into this problem is directly tied to solving the Climate Change challenge.

54 ENVIRONMENTAL SCIENCES↗

Impact of Solid State Roadway Lighting on Melatonin in Humans

Introduction: In 2009, the World Health Organization identified vehicle crashes, both injury-related and fatal, as a public health hazard. Roadway lighting has long been used to reduce crashes and improve the safety of all road users. Ocular light exposure at night can suppress melatonin levels in humans. At sufficient light levels, all visible light wavelengths can elicit this response, but melatonin suppression is maximally sensitive to visible short wavelength light. With the conversion of roadway lighting to solid state sources that have a greater short wavelength spectrum than traditional sources, there is a potential negative health impact through suppressed melatonin levels to roadway users and those living close to the roadway. This paper presents data on the impact of outdoor roadway lighting on salivary melatonin in three cohorts of participants: drivers, pedestrians, and those experiencing light trespass in their homes. Methods: In an outdoor naturalistic roadway environment, healthy participants (N = 29) each being assigned to a cohort of either pedestrian, driver, or light trespass experiment, were exposed to five different solid state light sources with differing spectral emissions and one no lighting condition. Salivary melatonin measurements were made under an average roadway luminance of 1.0 cd/m2 (IES RP-18 Roadway Lighting Requirements for expressway roads) with a corneal melanopic Equivalent Daylight Illuminances (EDI) ranging from 0.22 to 0.86 lux. Results: The results indicate that compared to the no roadway lighting condition, the roadway light source spectral content did not significantly impact salivary melatonin levels in the participants in any of the cohorts. Conclusions: These data show that recommended levels of street lighting for expressway roads do not elicit an acute suppression of salivary melatonin and suggest that the health benefit of roadway lighting for traffic safety is not compromised by an acute effect on salivary melatonin.

60 APPLIED LIFE SCIENCES↗

Multicolor Inks of Black Phosphorus for Midwave‐Infrared Optoelectronics

Abstract Black phosphorus (bP) based ink with a bulk bandgap of 0.33 eV ( λ = 3.7 µm) has recently been shown to be promising for large‐area, high performance mid‐wave infrared (MWIR) optoelectronics. However, the development of multicolor bP inks expanding across the MWIR wavelength range has been challenging. Here a multicolor ink process based on bP with spectral emission tuned from 0.28 eV ( λ = 4.4 µm) to 0.8 eV ( λ = 1.5 µm) is demonstrated. Specifically, through the reduction of bP particle size distribution (i.e., lateral dimension and thickness), the optical bandgap systematically blueshifts, reaching up to 0.8 eV. Conversely, alloying bP with arsenic (bP 1− x As x ) induces a redshift in the bandgap to 0.28 eV. The ink processed films are passivated with an infrared‐transparent epoxy for stable infrared emission in ambient air. Utilizing these multicolor bP‐based inks as an infrared light source, a gas sensing system is demonstrated that selectively detects gases, such as CO 2 and CH 4 whose absorption band varies around 4.3 and 3.3 µm, respectively. The presented ink formulation sets the stage for the advancement of multiplex MWIR optoelectronics, including spectrometers and spectral imaging using a low‐cost material processing platform.

Kim, Jae Ik↗

Electron-Nanobunch-Width-Dominated Spectral Power Law for Relativistic Harmonic Generation from Ultrathin Foils

Relativistic high-order harmonic generation from solid-density plasma offers a compact source of coherent ultraviolet and x-ray light. For solid targets much thinner than the laser wavelength, the plasma thickness can be tuned to increase conversion efficiency; a reduction in total charge allows for balancing the laser and plasma driving forces, producing the most effective interaction. Unlike for semi-infinite plasma surfaces, in this study we find that for ultrathin foil targets the dominant factor in the emission spectral shape is the finite width of the electron nanobunches, leading to a power-law exponent of approximately 10/3. Ultrathin foils produce higher-efficiency frequency conversion than solid targets for moderately relativistic (1 0 <40) interactions and also provide unique insight into how the trajectories of individual electrons combine and interfere to generate reflected attosecond pulses.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Melt pool instability detection using coaxial photodiode system validated by in-situ X-ray imaging

A co-axial photodiode monitoring system with high temporal resolution has been integrated into a proven test bench enabling synchronized side-view high speed X-ray imaging of melt pool dynamics and top-view spectral emission characterization of the melt pool. Here, this setup enables direct observation of melt pool phenomena and correlation between the two monitoring systems which can be directly scaled to commercial systems. The work demonstrates a 92% detection rate in keyhole collapse phenomena related to defect generation in SLM. Furthermore, the impact of gas flow on monitoring signals is studied to understand the fundamental importance of gas flow in commercial systems.

36 MATERIALS SCIENCE↗

Strategy for Ultranarrow Light Down-Conversion for Displays Based on Bicolor-Emitting 2D Colloidal Heterostructures

The demand for ultranarrow spectral emission below 10 nm is critical for next-generation displays. Although current colloidal nanocrystals are successful in light down-conversion applications, they fall short in matching the stringent color purity requirements set by standards like Rec. 2020. Achieving such narrow linewidths through material engineering alone remains elusive, necessitating innovative light management strategies that avoid optical losses and maintain device efficiency. Here, in this work, we present a novel 2D colloidal heterostructure design, combining a CdSe core nanoplatelet, a CdS crown, and a CdZnS shell, to achieve bright bicolor emission in the solid state (green/red) emission with tunable intensity ratios controlled by excitation power (either optical or electrical). Integration of these nanoplatelets into a dielectric cavity further narrows the emission linewidth to sub-2 nm while enhancing the photoluminescence intensity by up to 200 times, meeting the Rec. 2020 color purity targets. This approach paves the way for a strategy avoiding complex laser-based solutions.

2D nanocrystals↗

Detection and quantification of trace technetium in the presence of molybdenum using laser-induced breakdown spectroscopy

Technetium (Tc) is a very important element that is encountered in many aspects, from its presence in radioactive waste and its potential environmental impact to its use as a medical radioisotope. Its detection and quantification in liquid samples is traditionally cumbersome, involving detailed sample preparation and analysis by mass spectrometry or scintillation. This article demonstrates the first comprehensive emission spectral analysis of Tc from a liquid sample by immobilization in a polymer and analysis by laser-induced breakdown spectroscopy (LIBS). A survey of LIBS spectra was completed to identify the strongest analytical lines for quantification of trace Tc in the presence of Mo. The quantification of Tc in a Mo-containing matrix was selected because Tc radioisotopes are the daughter products of Mo isotope decay. The first reported calibration curves by LIBS are provided with limits of detection and quantification down to 0.710 µg mL −1 and 1.39 µg mL −1 , respectively. Ultimately, this study demonstrated the feasibility of trace Tc quantification using LIBS and will serve as a reference for future research related to monitoring this radioactive species.

Andrews, Hunter B. [Oak Ridge National Laboratory ↗

Heralded Generation of Correlated Photon Pairs from CdS/CdSe/CdS Quantum Shells

Quantum information processing demands efficient quantum light sources (QLS) capable of producing high-fidelity single photons or entangled photon pairs. Single epitaxial quantum dots (QDs) have long been proven to be efficient sources of deterministic single photons; however, their production via molecular-beam epitaxy presents scalability challenges. Conversely, colloidal semiconductor QDs offer scalable solution processing and tunable photoluminescence, but suffer from broader linewidths and unstable emissions. This leads to spectrally inseparable emission from exciton (X) and biexciton (XX) states, complicating the production of single photons and triggered photon pairs. Here, in this work, we demonstrate that colloidal semiconductor quantum shells (QSs) achieve significant spectral separation (∼75–80 meV) and long temporal stability of X and XX emissive states, enabling the observation of exciton-biexciton bunching in colloidal QDs. Our low-temperature single-particle measurements show cascaded XX-X emission of single photon pairs for over 200 s, with minimal overlap between X and XX features. The X-XX distinguishability allows for an in-depth theoretical characterization of cross-correlation strength, placing it in perspective with photon pairs of epitaxial counterparts. These findings highlight a strong potential of semiconductor quantum shells for applications in quantum information processing.

biexciton↗

X-ray self-emission imaging with spherically bent Bragg crystals on the Z-machine

Here, an x-ray imaging scheme using spherically bent crystals was implemented on the Z-machine to image x rays emitted by the hot, dense plasma generated by a Magnetized Liner Inertial Fusion (MagLIF) target. This diagnostic relies on a spherically bent crystal to capture x-ray emission over a narrow spectral range (<15 eV), which is established by a limiting aperture placed on the Rowland circle. The spherical crystal optic provides the necessary high-throughput and large field-of-view required to produce a bright image over the entire, one-cm length of the emitting column of a plasma. The average spatial resolution was measured and determined to be 18 µm for the highest resolution configuration. With this resolution, the radial size of the stagnation column can be accurately determined and radial structures, such as bifurcations in the column, are clearly resolved. The success of the spherical-crystal imager has motivated the implementation of a new, two-crystal configuration for identifying sources of spectral line emission using a differential imaging technique.

47 OTHER INSTRUMENTATION↗

The interplay between laser focusing conditions, expansion dynamics, ablation mechanisms, and emission intensity in ultrafast laser-produced plasmas

The interplay between ultrafast laser focusing conditions, emission intensity, expansion dynamics, and ablation mechanisms is critical to the detection of light isotopes relevant to nuclear energy, forensics, and geochemistry applications. Here, we study deuterium (2Hα) emission in plasmas generated from femtosecond laser ablation of a Zircaloy-4 target with a deuterium concentration of ≈37 at. %. Changes in emission intensity, plume morphology, crater dimensions, and surface modifications were investigated for varying focusing lens positions, where the laser was focused behind, at, and in front of the target. Spatially resolved optical emission spectroscopy and spectrally integrated plasma imaging were performed to investigate emission spectral features and plume morphology. Laser ablation crater dimensions and morphology were analyzed via optical profilometry and scanning electron microscopy. The 2Hα emission intensity showed significant reduction at the geometrical focal point or when the focal point is in front of the target. For all laser spot sizes, a two-component plume was observed but with different temporal histories. At the best focal point, the plume was spherical. When the laser was focused behind the target, the plume was elongated and propagated to farther distances than for the best focal position. In contrast, when the laser was focused in front of the target, filaments were generated in the beam path, and filament-plasma coupling occurred. By focusing the laser behind the target, the amount of material removal in the laser ablation process can be significantly reduced while still generating a plasma with a sufficient 2Hα emission signal for analysis.

Kautz, Elizabeth J. (ORCID:0000000263389223)↗