Engineering PapersSearch

SEARCH · Engineering Papers

Results for “spectral element method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

34 records · Page 2

ML-Based Pebble Power Reconstruction for Pebble Bed Reactor Analysis

Pebble power reconstruction has been explored to complement the conventional homogenized modeling approach in pebble bed reactor (PBR) analysis, as detailed heterogeneous geometry calculations are computationally expensive. The random distribution of pebble fuels within the core challenges the application of conventional pin power reconstruction methods. To address this, we introduce a machine learning approach based on the transformer model, composed of encoder and decoder layers, to estimate the flux and power form functions for reconstructing individual pebble neutron fluxes and powers. The homogeneous neutron flux distribution within each spectral zone (SZ) is obtained from finite element solutions of global diffusion or transport calculations. Verification tests demonstrate that the trained transformer model accurately predicts power form functions over a range of conditions, including variations in pebble enrichment, location, type, SZ size, and burnup. In particular, verification using a three-dimensional PBR benchmark with burned pebbles shows good agreement in heterogeneous pebble power distributions between Griffin and Serpent. These results highlight the potential of applying conventional pin power reconstruction approaches to PBR cores with randomly distributed pebbles.

22 GENERAL STUDIES OF NUCLEAR REACTORS

Demonstration of an AI-driven workflow for dynamic x-ray spectroscopy

X-ray absorption near edge structure (XANES) spectroscopy is a powerful technique for characterizing the chemical state and symmetry of individual elements within materials, but requires collecting data at many energy points which can be time-consuming. While adaptive sampling methods exist for efficiently collecting spectroscopic data, they often lack domain-specific knowledge about the structure of XANES spectra. Here we demonstrate a knowledge-injected Bayesian optimization approach for adaptive XANES data collection that incorporates understanding of spectral features like absorption edges and pre-edge peaks. We show this method accurately reconstructs the absorption edge of XANES spectra using only 15–20% of the measurement points typically needed for conventional sampling, while maintaining the ability to determine the x-ray energy of the sharp peak after the absorption edge with errors less than 0.03 eV, the absorption edge with errors less than 0.1 eV; and overall root-mean-square errors less than 0.005 compared to traditionally sampled spectra. Our experiments on battery materials and catalysts demonstrate the method’s effectiveness for both static and dynamic XANES measurements, improving data collection efficiency and enabling better time resolution for tracking chemical changes. This approach advances the degree of automation in XANES experiments, reducing the common errors of under- or over-sampling points near the absorption edge and enabling dynamic experiments that require high temporal resolution or limited measurement time.

Bayesian optimization

Determining Stellar Elemental Abundances from DESI Spectra with the Data-driven Payne

Abstract Stellar abundances for a large number of stars provide key information for the study of Galactic formation history. Large spectroscopic surveys such as the Dark Energy Spectroscopic Instrument (DESI) and LAMOST take median-to-low-resolution (R≲ 5000) spectra in the full optical wavelength range for millions of stars. However, the line-blending effect in these spectra causes great challenges for elemental abundance determination. Here we employDD-Payne, a data-driven method regularized by differential spectra from stellar physical models, to the DESI early data release spectra for stellar abundance determination. Our implementation delivers 15 labels, including effective temperatureT eff , surface gravity log g , microturbulence velocityv mic , and the abundances for 12 individual elements, namely C, N, O, Mg, Al, Si, Ca, Ti, Cr, Mn, Fe, and Ni. Given a spectral signal-to-noise ratio of 100 per pixel, the internal precisions of the label estimates are about 20 K forT eff , 0.05 dex for log g , and 0.05 dex for most elemental abundances. These results agree with the theoretical limits from the Crámer–Rao bound calculation within a factor of 2. The majority of the accreted halo stars contributed by the Gaia–Enceladus–Sausage are discernible from the disk and in situ halo populations in the resultant [Mg/Fe]–[Fe/H] and [Al/Fe]–[Fe/H] abundance spaces. We also provide distance and orbital parameters for the sample stars, which spread over a distance out to ∼100 kpc. The DESI sample has a significantly higher fraction of distant (or metal-poor) stars than the other existing spectroscopic surveys, making it a powerful data set for studying the Galactic outskirts. The catalog is publicly available.

Astronomy & Astrophysics

Tabletop soft x-ray absorption spectroscopy for molecular fingerprinting

For applications related to nuclear security, safeguards, and nonproliferation, it is often critical to know the molecular compositions of lanthanide- and actinide-containing samples. Spectroscopy is a widely used tool that looks at the interaction between light and matter: Different species absorb or emit light at unique wavelengths which act as signatures. However, there is a limited number of tools that can achieve high-sensitivity, accurate measurements of lanthanide and actinide molecular compositions. Candidate methods include mass spectrometry, which usually destroys at least part of the sample and requires complicated stoichiometry to guess the original sample’s molecular compositions; optical spectroscopies, which have great atomic but limited molecular sensitivities or other drawbacks which make sensing molecules difficult like limited light sources or strong absorption in the atmosphere; and nuclear spectroscopies (gamma, neutron) which also have limited sources and long (>minute) collection times. As such, the purpose of our research is to develop a new tool to better distinguish between subtle differences in molecules containing lanthanides and actinides. Soft x-ray spectroscopy is sensitive to molecular form and is minimally intrusive/nondestructive to the sample. However, soft x-ray light with sufficient brightness for spectroscopy is typically limited to user-facilities like synchrotrons or free electron lasers, where beamtimes are competitive, and work with radiological materials may be difficult or entirely prohibited. To overcome this issue, our Team has developed a custom tabletop laser-driven, soft x-ray light source which employs high harmonic generation (HHG). Soft x-ray spectroscopy can distinguish between subtly different molecules, in the spectral range which we need to study these heavy elements. A tabletop system provides an effective and affordable tool to find both the elemental and chemical specificity of lanthanide and samples. Creating a light source in the soft x-ray spectrum is difficult because these wavelengths in the range 5-20 nm (20-350 eV photon energies) only penetrate several 100s of nm in most solid materials and only reflect well in shallow, grazing incident angles. The results are applicable to nuclear forensics, because molecular fingerprinting of lanthanide and actinide samples can be used to back out the origin and processing method of nuclear materials (Skrodzki, et al.).

36 MATERIALS SCIENCE

Designing for cooperative grain boundary segregation in multicomponent alloys

Tailoring the nanoscale distribution of chemical species at grain boundaries is a powerful method to dramatically influence the properties of polycrystalline materials. However, classical approaches to the problem have tacitly assumed that only competition is possible between solute species. In this paper, we show that solute elements can cooperate in the way they segregate to grain boundaries: In properly targeted alloys, the different chemical species cooperate to each fill complementary grain boundary sites disfavored by the other. By developing a theoretical “spectral” approach to this problem based on quantum-accurate grain boundary site distributions, we show how grain boundaries can be cooperatively alloyed, whether by depletion or enrichment. We provide machine-learned cosegregation information for over 700 ternary aluminum-based alloys and experimentally validate the concept in one ternary alloy where cosegregation is not expected by prior models but is expected based on the cooperative model.

grain boundaries

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER

Pulsed contact glow discharge electrification for online material quantification

Real-time elemental analysis of liquids in extreme environments remains a significant challenge for sensor development, particularly in applications such as advanced nuclear reactors. Plasma-based optical emission spectroscopy offers a promising solution. In this study, we investigate pulsed contact glow discharge electrolysis (CGDE) as an alternative plasma generation method for emission-based material quantification. Using aqueous NaCl solutions, we examine the role of discharge polarity on plasma behavior, emission characteristics, and spectral output. Our results demonstrate that cathodic discharges generate more energetic plasmas, enabling the detection of ionic species such as cerium, while anodic discharges favor atomic emission. These findings reveal a potential dual-mode sensing capability controlled by circuit configuration rather than hardware changes. Through synchronized measurements of emission, current, bubble, and spectral dynamics, we present a model in which electron emission and ohmic heating drive plasma formation. This model enhances our understanding of pulsed-CGDE and supports its potential as a versatile, adaptable platform for future deployment in high-temperature liquids such as molten salts.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL

Laser-spectroscopy testbed for impurity monitoring in liquid metal-cooled fast reactors

A significant challenge in sodium-cooled fast reactors is controlling impurities, in particular oxygen impurities, within the sodium coolant, as they can accelerate corrosion and indicate leaks. Optical methods offer the potential to rapidly detect small concentrations of both gaseous and metal impurities that accelerate corrosion, plug coolant channels, and lead to increased activation of isotopes in the coolant. We present the design and performance of an apparatus designed to enable the application of multiple optical analytical techniques, such as laser-induced breakdown spectroscopy, to detect elemental impurities in the sodium melt with high sensitivity. Here, we experimentally demonstrate the detection of characteristic sodium and oxygen spectral lines in liquid sodium, which sets the stage for the optimization of its analytical sensitivity. A robust sensor of this type integrated with the sodium cooling loop has the potential to significantly improve the safety and operational efficiency of generation IV nuclear reactors.

47 OTHER INSTRUMENTATION

A Comparison of Three Neodymium Atomic Data Sets for Kilonova Modeling

We examine the impact of input neodymium (Nd) atomic data on the light curves and spectra of kilonovae (KNe), probing the sensitivity of kilonova observables to the atomic physics of this important lanthanide element. We use the SuperNu Monte Carlo radiative transfer code, simulating a simple semianalytic 1D kilonova (KN) with a pure Nd atmosphere, fixing the radiative transfer method while using input atomic data generated by three different codes: the LANL suite of atomic physics codes, HULLAC, and Autostructure. We see that the choice of atomic data significantly shapes the resulting light curves and spectra. Peak bolometric luminosities differ by a ratio of nearly 1.5 between HULLAC/Autostructure and LANL data sets. Moreover, we observe significant near- to mid-IR differences in the structure of the spectra. We specifically attribute these differences to the choice of atomic data for neutral Nd I. Many of the results here have been adapted from a presentation at “Radiative Transfer and Atomic Physics of Kilonovae” in Stockholm, 2023. We additionally present a LANL data set with energies calibrated to available values in the NIST Atomic Spectra Database, and demonstrate that this calibration also significantly affects IR spectral structure at late time. The substantial differences in KN observables that arise from tuning the atomic data of just one lanthanide element highlight the special attention that must be paid to atomic physics uncertainties when modeling KNe, from AT2017gfo to beyond.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC

Absorber Clamp for Microcalorimeter Decay Energy Spectrometry

Microcalorimeter Decay Energy Spectrometry (DES) is of interest to nuclear safeguards due to its ability to provide high precision isotopic compositions of nanogram-to microgram-scale samples of Pu and U and related daughter products. The DES method is able to record decay energy of each alpha-decay event in a sample that is embedded in a metal matrix (absorber) and thermally linked to a microcalorimeter detector. This work optimizes the DES technique used to thermally link the absorber and microcalorimeter detector element to allow for more rapid assembly and to increase detector performance and operating life. Optimized attachment methods are crucial for enhancing the viability of DES in high-sample-throughput facilities, such as those that support international nuclear safeguards measurements. Here, in this study, we designed and implemented a pressure-based absorber clamp and evaluated the performance of this new attachment method relative to pressed indium bond attachment. Results using the absorber clamp demonstrate a streamlined detector assembly procedure that minimizes accidental damage to detectors, as well as increasing detector pulse speeds by 57%. Spectral comparison shows the clamp preserves detector performance relative to indium attachment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Understanding the structural and morphological effects of synthesis route on NpO 2

The availability of actinide standard materials for use in nuclear safeguard applications is critical, as is thorough characterization thereof. Although accurate trace element compositions and isotopic considerations are paramount for deployment of reference standards, structural characterization is also essential towards accurately describing the chemical form and potential matrix effects in candidate materials. Here, to this end, samples of NpO 2 were synthesized via a direct denitration (DD) method and probed with powder X-ray diffraction (PXRD), Raman spectroscopy, and scanning electron microscopy (SEM) for structural and morphological characterization and comparison with NpO 2 materials produced via modified direct denitration (MDD). PXRD confirmed the bulk identity of NpO 2 , and no additional phases were identified using this method. Analysis of Raman data collected using a 532 nm excitation wavelength indicates that samples are mostly phase pure; however, some variability in spectral features is observed. Analysis of additional spectroscopic data collected with a 785 nm excitation wavelength revealed variability in the relative intensity of spectral features. Raman spectroscopy indicates that the sample is primarily NpO 2 ; however, additional signals indicate possible structural disorder, oxidized species, or potential contributions from other Np phases. To further investigate the possibility of additional phase contributions within the sample of NpO 2 , Raman spectroscopic mapping was employed to examine the homogeneity of the sample produced via DD. From this analysis, we determined that despite variability in the intensity of Raman-active vibrational modes, consistent spectra are obtained throughout the area of the sample investigated. SEM images show aggregates with variable sizes and shapes, with rounded, primary particles possessing an average diameter of approximately 100 nm. Comparison of the results of these multimodal analyses to the literature indicates that the crystal chemical, spectroscopic, and microstructural properties of NpO 2 vary based on synthesis method, even if X-ray diffraction data indicate that the bulk phase is NpO 2 .

Direct denitration

Hyperspectral x-ray imaging mapping capabilities for nuclear forensics

Nuclear forensics relies on the integration of complementary signatures to constrain the origins and history of materials. Outcomes benefit from the timeliness and precision of the disparate methods that form typical analysis chains. Sample forms are often either minute in quantity or contain signatures like morphology or composition heterogeneity encoded on a microscale, so many analysis techniques focus on resolving signatures on ever-smaller length scales. The new hyperspectral x-ray imaging (HXI) instrument developed at Los Alamos National Laboratory seeks to improve the information available from scanning electron microscopy (SEM) x-ray spectrum analysis through superior spectral energy resolution vs. typical energy dispersive spectroscopy (EDS) systems in common use in nuclear forensics and other microanalysis fields. Based on arrays of transition-edge sensor (TES) microcalorimeter detectors, this instrument achieves a typical energy resolution of 7 eV full-width at half-maximum (FWHM) at 2 keV, opening new possibilities in trace element detection/analysis and chemical state determination through spectral shape shifts. We present here some of the first applications of the HXI instrument to actinide samples and discuss potential maturation of this nascent technology for future analysis pipelines.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Advancing AI-Driven Analysis in X-ray Absorption Spectroscopy: Spectral Domain Mapping and Universal Models

In recent years, rapid progress has been made in developing artificial intelligence (AI) and machine learning (ML) methods for X-ray absorption spectroscopy (XAS) analysis. Compared to traditional XAS analysis methods, AI/ML approaches offer dramatic improvements in efficiency and help eliminate human bias. To advance this field, we advocate an AI-driven XAS analysis pipeline that features several interconnected key building blocks: benchmarks, workflows, databases, and AI/ML models. Specifically, we present two case studies for XAS ML. In the first study, we demonstrate the importance of reconciling the discrepancies between simulation and experiment using spectral domain mapping (SDM). Our ML model, which is trained solely on simulated spectra, predicts an incorrect oxidation state trend for Ti atoms in a combinatorial zinc titanate film. After transforming the experimental spectra into a simulation-like representation using SDM, the same model successfully recovers the correct oxidation state trend. In the second study, we explore the development of universal XAS ML models that are trained on the entire periodic table, which enables them to leverage common trends across elements. Looking ahead, we envision that an AI-driven pipeline can unlock the potential of real-time XAS analysis to accelerate scientific discovery.

36 MATERIALS SCIENCE

A structured framework for predicting sustainable aviation fuel properties using liquid-phase FTIR and machine learning

Sustainable aviation fuels have the potential to improve efficiency, reduce emissions, and enhance energy security. To help identify viable sustainable aviation fuels and accelerate research, machine learning models have been developed to predict relevant physicochemical properties. However, many models have limited applicability, leverage data from complex analytical techniques with confined spectral ranges, or use feature decomposition methods that offer limited interpretability. Using liquid-phase Fourier Transform Infrared (FTIR) spectra, this study presents a structured method for creating accurate and interpretable property prediction models for neat molecules, aviation fuels, and blends. Liquid FTIR spectra can be collected quickly and consistently, offering high reliability, sensitivity, and component specificity using less than 2 ml of sample. The method first decomposes FTIR spectra into fundamental building blocks using non-negative matrix factorization (NMF) to enable scientific analysis of FTIR spectra attributes and fuel properties. The NMF features are then used to create five ensemble models for predicting final boiling point, flash point, freezing point, density at 15°C, and kinematic viscosity at -20°C. All models were trained using experimental property data from neat molecules, aviation fuels, and blends. The models accurately predict key properties across a broad range of neat molecules and representative fuels and blends, while enabling interpretation of relationships between compositional elements, such as functional groups or chemical classes, and their resulting properties. This demonstrates strong potential to support sustainable aviation fuel research and development. The models and data are available on an interactive web tool.

Fourier transform infrared spectroscopy

Computational Optimization of 133m Xe Production via Neutron Irradiation in a TRIGA Reactor

Here, the Comprehensive Nuclear-Test-Ban Treaty bans all nuclear tests worldwide. As part of treaty compliance, the concentration of radioactive nuclides in the atmosphere is monitored to detect nuclear weapons tests. Radioactive noble gas fission products, specifically radioxenon, can vent into the atmosphere after a nuclear weapons test, even if the test is well contained underground or underwater. Radioxenon thus serves as a signal for nuclear weapons tests. All atmospheric monitoring systems require samples of radioxenon isotopes for detector calibration, quality control, and certification. Here, we present a novel, improved method for creating samples of 133m Xe via neutron irradiation of 132 Xe in the Washington State University TRIGA reactor. 132 Xe neutron absorption results in either 133 Xe or 133m Xe—thermal neutron absorption results in 133m Xe 12% of the time, while fast neutron absorption (above ~1 MeV) results in 133m Xe ~50% of the time. To optimize the production of 133m Xe via neutron absorption in 132 Xe in the thermal TRIGA reactor, spectral tuning using an irradiation chamber is required to maximize the fraction of fast neutrons being absorbed and minimize the number of thermal neutrons interacting with the 132 Xe. We used MCNP to tally 132 Xe absorptions with the isotopic tally function, flux tallies and neutron attenuation to estimate the number of neutrons reaching the 132 Xe through the irradiation chamber, and the adjoint importance function to improve the source strength estimate. Additionally, we performed a heat transfer analysis for safety considerations. It was determined that the use of a 96% enriched 10 B boron carbide chamber, placed next to the fuel elements in reactor position D8, increases the 133m Xe/ 133 Xe activity ratio from a baseline value of 0.3 to 1.0, a 233% increase. Additionally, it was determined that the alpha heating produced in the boron does not become an unmanageable problem in the Washington State University reactor.

37 - INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL C

A Scalable Interior‐Point Gauss–Newton Method for PDE‐Constrained Optimization With Bound Constraints

Here, we present a scalable approach to solve a class of partial differential equation (PDE)‐constrained optimization problems with bound constraints. This approach utilizes a robust full‐space interior‐point (IP)‐Gauss–Newton optimization method. To cope with the poorly‐conditioned IP‐Gauss–Newton saddle‐point linear systems that need to be solved approximately, once per optimization step, we propose two spectrally related preconditioners. These preconditioners leverage the limited informativeness of data in regularized PDE‐constrained optimization problems. A block Gauss–Seidel preconditioner is proposed for the GMRES‐based solution of the IP‐Gauss–Newton linear systems. It is shown, for a large‐class of PDE‐ and bound‐constrained optimization problems, that the spectrum of the block Gauss–Seidel preconditioned IP‐Gauss–Newton matrix is asymptotically independent of discretization and is not impacted by the ill‐conditioning that notoriously plagues interior‐point methods. We exploit symmetry of the IP‐Gauss–Newton linear systems and propose a regularization and log‐barrier Hessian preconditioner for the preconditioned conjugate gradient (PCG)‐based solution of the equivalent IP‐Gauss–Newton–Schur complement linear systems. The eigenvalues of the block Gauss–Seidel preconditioned IP‐Gauss–Newton matrix, that are not equal to one, are identical to the eigenvalues of the regularization and log‐barrier Hessian preconditioned Schur complement matrix. The scalability of the approach is demonstrated on two example problems. The numerical solution of these optimization problems is shown to require a discretization independent number of IP‐Gauss–Newton linear solves. Furthermore, the linear systems are solved in a discretization and IP ill‐conditioning independent number of preconditioned Krylov subspace iterations. The parallel scalability of the preconditioner, achieved via algebraic multigrid component solvers when applicable, and the aforementioned algorithmic scalability permits a parallel scalable means to compute solutions of a large class of PDE‐ and bound‐constrained problems.

PDE-constrained optimization